Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Endosc Surg Allied Technol ; 1(3): 137-43, 1993 Jun.
Article in English | MEDLINE | ID: mdl-8055313

ABSTRACT

To evaluate the feasibility of laparoscopic transcystic lithotripsy of common bile duct stones, a phantom model comprising bovine liver and biliary tract tissue integrated within a laparoscopic trainer was built. A 9 French cholangioscope was introduced via the cystic duct into the common bile duct in which a human gall stone of known composition had been introduced. Lithotripsy was performed using either a laser or electrohydraulic probe passed through the working channel of the cholangioscope following which the stone fragments were manipulated into the duodenum through the papilla of Vater using the choledochoscope. A total of 20 lithotripsies with each energy form were performed. Lithotripsy was successful in breaking the stones into fragments smaller than 6 mm. The energy expenditure was comparable with a mean of 49 J for laser lithotripsy (range 9 to 159 J), and 53 J (range 16 to 160 J) for electrohydraulic wave lithotripsy. The lithotripsy time measured from introduction of the cholangioscope until its removal was a mean of 30 minutes for electrohydraulic wave lithotripsy and 41 minutes for dye laser lithotripsy. This difference was statistically significant. Macroscopic tissue damage to the common bile duct wall was not observed following any procedure. An additional experiment was performed to evaluate damage that could be caused to the wall of the common bile duct. Both electrohydraulic shock wave and pulsed dye laser lithotripsy without optical feedback regulation caused severe tissue defects when there was tissue contact or distance less than 2 mm. With optical feedback regulation however, no tissue damage was induced by laser lithotripsy.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Gallstones/surgery , Laparoscopy/methods , Lithotripsy, Laser , Lithotripsy , Animals , Cattle , Combined Modality Therapy , Common Bile Duct/pathology , Common Bile Duct/surgery , Endoscopy, Digestive System/instrumentation , Feasibility Studies , Gallstones/pathology , Gallstones/therapy , Humans , Laparoscopes , Lithotripsy/instrumentation , Lithotripsy, Laser/instrumentation , Liver , Models, Anatomic , Models, Structural , Time Factors
2.
Chirurg ; 62(4): 276-83, 1991 Apr.
Article in German | MEDLINE | ID: mdl-1830543

ABSTRACT

Currently 'Minimally Invasive Surgery' (MIS) is rapidly finding a widening range of applications and increasing numbers of surgical departments start with new MIS techniques. Surgical work under endoscopic control requires an intensive readjustment to operation technique bringing about new problems in training. We believe that intensive training of MIS procedures on suitable training phantoms should be a prerequisite for clinical application of MIS and therefore have established a training center for MIS in Tübingen, FRG, offering weekly hands on training courses for different procedures.


Subject(s)
Education, Medical, Continuing , General Surgery/education , Laparoscopy , Proctoscopy , Curriculum , Germany , Humans , Laparoscopes , Microsurgery/instrumentation , Proctoscopes , Video Recording/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...