Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Acta Orthop ; 95: 152-156, 2024 03 21.
Article in English | MEDLINE | ID: mdl-38597205

ABSTRACT

BACKGROUND AND PURPOSE: Large language models like ChatGPT-4 have emerged. They hold the potential to reduce the administrative burden by generating everyday clinical documents, thus allowing the physician to spend more time with the patient. We aimed to assess both the quality and efficiency of discharge documents generated by ChatGPT-4 in comparison with those produced by physicians. PATIENTS AND METHODS: To emulate real-world situations, the health records of 6 fictional orthopedic cases were created. Discharge documents for each case were generated by a junior attending orthopedic surgeon and an advanced orthopedic resident. ChatGPT-4 was then prompted to generate the discharge documents using the same health record information. The quality assessment was performed by an expert panel (n = 15) blinded to the source of the documents. As secondary outcome, the time required to generate the documents was compared, logging the duration of the creation of the discharge documents by the physician and by ChatGPT-4. RESULTS: Overall, both ChatGPT-4 and physician-generated notes were comparable in quality. Notably, ChatGPT-4 generated discharge documents 10 times faster than the traditional method. 4 events of hallucinations were found in the ChatGPT-4-generated content, compared with 6 events in the human/physician produced notes. CONCLUSION: ChatGPT-4 creates orthopedic discharge notes faster than physicians, with comparable quality. This shows it has great potential for making these documents more efficient in orthopedic care. ChatGPT-4 has the potential to significantly reduce the administrative burden on healthcare professionals.


Subject(s)
Orthopedic Surgeons , Orthopedics , Humans , Pilot Projects , Patient Discharge , Health Personnel
2.
Eur Radiol ; 34(1): 270-278, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37566272

ABSTRACT

OBJECTIVE: Patients with rotator cuff tears present often with glenohumeral joint instability. Assessing anatomic angles and shoulder kinematics from fluoroscopy requires labelling of specific landmarks in each image. This study aimed to develop an artificial intelligence model for automatic landmark detection from fluoroscopic images for motion tracking of the scapula and humeral head. MATERIALS AND METHODS: Fluoroscopic images were acquired for both shoulders of 25 participants (N = 12 patients with unilateral rotator cuff tear, 6 men, mean (standard deviation) age: 63.7 ± 9.7 years; 13 asymptomatic subjects, 7 men, 58.2 ± 8.9 years) during a 30° arm abduction and adduction movement in the scapular plane with and without handheld weights of 2 and 4 kg. A 3D full-resolution convolutional neural network (nnU-Net) was trained to automatically locate five landmarks (glenohumeral joint centre, humeral shaft, inferior and superior edges of the glenoid and most lateral point of the acromion) and a calibration sphere. RESULTS: The nnU-Net was trained with ground-truth data from 6021 fluoroscopic images of 40 shoulders and tested with 1925 fluoroscopic images of 10 shoulders. The automatic landmark detection algorithm achieved an accuracy above inter-rater variability and slightly below intra-rater variability. All landmarks and the calibration sphere were located within 1.5 mm, except the humeral landmark within 9.6 mm, but differences in abduction angles were within 1°. CONCLUSION: The proposed algorithm detects the desired landmarks on fluoroscopic images with sufficient accuracy and can therefore be applied to automatically assess shoulder motion, scapular rotation or glenohumeral translation in the scapular plane. CLINICAL RELEVANCE STATEMENT: This nnU-net algorithm facilitates efficient and objective identification and tracking of anatomical landmarks on fluoroscopic images necessary for measuring clinically relevant anatomical configuration (e.g. critical shoulder angle) and enables investigation of dynamic glenohumeral joint stability in pathological shoulders. KEY POINTS: • Anatomical configuration and glenohumeral joint stability are often a concern after rotator cuff tears. • Artificial intelligence applied to fluoroscopic images helps to identify and track anatomical landmarks during dynamic movements. • The developed automatic landmark detection algorithm optimised the labelling procedures and is suitable for clinical application.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Male , Humans , Middle Aged , Aged , Rotator Cuff , Artificial Intelligence , Range of Motion, Articular , Fluoroscopy , Algorithms , Shoulder Joint/diagnostic imaging , Biomechanical Phenomena
3.
Diagn Progn Res ; 7(1): 21, 2023 Nov 07.
Article in English | MEDLINE | ID: mdl-37932868

ABSTRACT

BACKGROUND: Prediction models for outcomes after orthopedic surgery provide patients with evidence-based postoperative outcome expectations. Our objectives were (1) to identify prognostic factors associated with the postoperative shoulder function outcome (the Oxford Shoulder Score (OSS)) and (2) to develop and validate a prediction model for postoperative OSS. METHODS: Patients undergoing arthroscopic rotator cuff repair (ARCR) were prospectively documented at a Swiss orthopedic tertiary care center. The first primary ARCR in adult patients with a partial or complete rotator cuff tear were included between October 2013 and June 2021. Thirty-two potential prognostic factors were used for prediction model development. Two sets of factors identified using the knowledge from three experienced surgeons (Set 1) and Bayesian projection predictive variable selection (Set 2) were compared in terms of model performance using R squared and root-mean-squared error (RMSE) across 45 multiple imputed data sets using chained equations and complete case data. RESULTS: Multiple imputation using data from 1510 patients was performed. Set 2 retained the following factors: American Society of Anesthesiologists (ASA) classification, baseline level of depression and anxiety, baseline OSS, operation duration, tear severity, and biceps status and treatment. Apparent model performance was R-squared = 0.174 and RMSE = 7.514, dropping to R-squared = 0.156, and RMSE = 7.603 after correction for optimism. CONCLUSION: A prediction model for patients undergoing ARCR was developed using solely baseline and operative data in order to provide patients and surgeons with individualized expectations for postoperative shoulder function outcomes. Yet, model performance should be improved before being used in clinical routine.

4.
J Orthop Traumatol ; 24(1): 41, 2023 Aug 04.
Article in English | MEDLINE | ID: mdl-37542140

ABSTRACT

BACKGROUND: Rotator cuff muscles stabilise the glenohumeral joint and contribute to the initial abduction phase with other shoulder muscles. This study aimed to determine if the load-induced increase in shoulder muscle activity during a 30° abduction test is influenced by asymptomatic or symptomatic rotator cuff pathologies. MATERIALS AND METHODS: Twenty-five patients with unilateral rotator cuff tears (age, 64.3 ± 10.2 years), 25 older control subjects (55.4 ± 8.2 years) and 25 younger control subjects (26.1 ± 2.3 years) participated in this study. Participants performed a bilateral 30° arm abduction and adduction movement in the scapular plane with handheld weights (0-4 kg). Activity of the deltoid, infraspinatus, biceps brachii, pectoralis major, latissimus dorsi and upper trapezius muscles was analysed at maximum abduction angle after normalisation to maximum voluntary contraction. Shoulders were classified into rotator cuff tendinopathy, asymptomatic and symptomatic rotator cuff tears, and healthy based on magnetic resonance images. A linear mixed model (loads, shoulder types) with random effects (shoulder identification) was applied to the log-transformed muscle activities. RESULTS: Muscle activity increased with increasing load in all muscles and shoulder types (P < 0.001), and 1-kg increments in additional weights were significant (P < 0.001). Significant effects of rotator cuff pathologies were found for all muscles analysed (P < 0.05). In all muscles, activity was at least 20% higher in symptomatic rotator cuff tears than in healthy shoulders (P < 0.001). Symptomatic rotator cuff tears showed 20-32% higher posterior deltoid (P < 0.05) and 19-25% higher pectoralis major (P < 0.01) activity when compared with asymptomatic tears. CONCLUSIONS: Rotator cuff pathologies are associated with greater relative activity of shoulder muscles, even with low levels of additional load. Therefore, the inclusion of loaded shoulder tests in the diagnosis and rehabilitation of rotator cuff pathologies can provide important insight into the functional status of shoulders and can be used to guide treatment decisions. LEVEL OF EVIDENCE: Level 2. TRIAL REGISTRATION: Ethical approval was obtained from the regional ethics committee (Ethics Committee Northwest Switzerland EKNZ 2021-00182), and the study was registered at clinicaltrials.gov on 29 March 2021 (trial registration number NCT04819724, https://clinicaltrials.gov/ct2/show/NCT04819724 ).


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Aged , Humans , Middle Aged , Range of Motion, Articular/physiology , Rotator Cuff , Rotator Cuff Injuries/diagnosis , Shoulder/physiology , Case-Control Studies
5.
J Shoulder Elbow Surg ; 32(10): 2008-2016, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37178965

ABSTRACT

BACKGROUND: The Constant score (CS) is often used clinically to assess shoulder function and includes a muscle strength assessment only for abduction. The aim of this study was to evaluate the test-retest reliability of isometric shoulder muscle strength during various positions of abduction and rotation with the Biodex dynamometer and to determine their correlation with the strength assessment of the CS. METHODS: Ten young healthy subjects participated in this study. Isometric shoulder muscle strength was measured during 3 repetitions for abduction at 10° and 30° abduction in the scapular plane (with extended elbow and hand in neutral position) and for internal and external rotation (with the arm at 15° abduction in the scapular plane and elbow flexed at 90°). Muscle strength tests with the Biodex dynamometer were measured in 2 different sessions. The CS was acquired only in the first session. Intraclass correlation coefficients (ICCs) with 95% confidence interval, limits of agreement, and paired t tests for repeated tests of each abduction and rotation task were calculated. Pearson's correlation between the strength parameter of the CS and isometric muscle strength was investigated. RESULTS: Muscle strength did not differ between tests (P > .05) with good to very good reliabilities for abduction at 10° and 30°, external rotation and internal rotation (ICC >0.7 for all). A moderate correlation of the strength parameter of the CS with all isometric shoulder strength parameters was observed (r > 0.5 for all). CONCLUSION: Shoulder muscle strength for abduction and rotation measured with the Biodex dynamometer are reproducible and correlate with the strength assessment of the CS. Therefore, these isometric muscle strength tests can be further employed to investigate the effect of different shoulder joint pathology on muscle strength. These measurements consider a more comprehensive functionality of the rotator cuff than the single strength evaluation in abduction within the CS as both abduction and rotation are assessed. Potentially, this would allow for a more precise differentiation between the various outcomes of rotator cuff tears.


Subject(s)
Shoulder Joint , Shoulder , Humans , Reproducibility of Results , Isometric Contraction/physiology , Rotator Cuff/physiology , Shoulder Joint/physiology , Muscle Strength/physiology , Muscle Strength Dynamometer
6.
JSES Int ; 7(1): 50-57, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36820428

ABSTRACT

Background: The identification of factors that specify prognostic models for postoperative results should be based on the best scientific evidence and expert assessment. We aimed to identify, map, and evaluate potential prognostic factors for the improvement of shoulder function in patients undergoing arthroscopic rotator cuff repair. Methods: Longitudinal primary studies of arthroscopic rotator cuff repair reporting any multivariable factor analyses for shoulder function improvement with an endpoint assessment of at least 6 months were included. We systematically searched EMBASE, Medline, and Scopus for articles published between January 2014 and June 2021. The risk of bias of included studies and the quality of evidence were assessed using the Quality in Prognosis Studies tool and an adapted Grading of Recommendations, Assessment, Development, and Evaluations framework. Results: Overall, 24 studies including 73 outcome analyses were included. We classified younger age and smaller tear size as probably prognostic for a greater improvement in objective outcomes. Shorter symptom duration, absence of a worker compensation claim, low preoperative level of functional status, and high preoperative pain level were classified as probably prognostic for greater improvement in patient-reported outcome measures. The quality of the synthesized evidence was low. Twenty-one studies had an overall high risk of bias. Conclusion: Six potential prognostic factors for shoulder function after arthroscopic rotator cuff repair were identified. Along with ongoing expert opinion assessments, they will feed into a prognostic model-building process.

7.
JMIR Res Protoc ; 11(12): e43769, 2022 Dec 23.
Article in English | MEDLINE | ID: mdl-36563028

ABSTRACT

BACKGROUND: Rotator cuff tears are a common shoulder injury, but they sometimes remain undiagnosed, as symptoms can be limited. Altered shoulder biomechanics can lead to secondary damage and degeneration. In biomechanical analyses, the shoulder (ie, the glenohumeral joint) is normally idealized as a ball-and-socket joint, even though a translation is often observed clinically. To date, no conclusive changes in glenohumeral translation have been reported in patients with rotator cuff tears, and it is unknown how an additional handheld weight that is comparable to those used during daily activities will affect glenohumeral translations in patients with rotator cuff tears. OBJECTIVE: This study aims to assess the load-induced glenohumeral translation (liTr) in patients with rotator cuff tears and its association with the load-induced changes in muscle activation (liMA). METHODS: Patients and asymptomatic controls will be recruited. Participants will fill out health questionnaires and perform 30° arm abduction and adduction trials, during which they will hold different handheld weights of a maximum of 4 kg while motion capture and electromyographic data are collected. In addition, fluoroscopic images of the shoulders will be taken for the same movements. Isometric shoulder muscle strength for abduction and rotation will be assessed with a dynamometer. Finally, shoulder magnetic resonance images will be acquired to assess muscle status and injury presence. The dose-response relationship between additional weight, liTr, and liMA will be evaluated. RESULTS: Recruitment and data collection began in May 2021, and they will last until the recruitment target is achieved. Data collection is expected to be completed by the end of 2022. As of November 2022, data processing and analysis are in progress, and the first results are expected to be submitted for publication in 2023. CONCLUSIONS: This study will aid our understanding of biological variations in liTr, the influence of disease pathology on liTr, the potential compensation of rotator cuff tears by muscle activation and size, and the association between liTr and patient outcomes. The outcomes will be relevant for diagnosis, treatment, and rehabilitation planning in patients with rotator cuff tears. TRIAL REGISTRATION: ClinicalTrials.gov NCT04819724; https://clinicaltrials.gov/ct2/show/NCT04819724. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/43769.

8.
Biomechanics (Basel) ; 2(2): 255-263, 2022 May 19.
Article in English | MEDLINE | ID: mdl-35677586

ABSTRACT

Rotator cuff tears are often linked to superior translational instability, but a thorough understanding of glenohumeral motion is lacking. This study aimed to assess the reliability of fluoroscopically measured glenohumeral translation during a shoulder abduction test. Ten patients with rotator cuff tears participated in this study. Fluoroscopic images were acquired during 30° abduction and adduction in the scapular plane with and without handheld weights of 2 kg and 4 kg. Images were labelled by two raters, and inferior-superior glenohumeral translation was calculated. During abduction, glenohumeral translation (mean (standard deviation)) ranged from 3.3 (2.2) mm for 0 kg to 4.1 (1.8) mm for 4 kg, and from 2.3 (1.5) mm for 0 kg to 3.8 (2.2) mm for 4 kg for the asymptomatic and symptomatic sides, respectively. For the translation range, moderate to good interrater (intra-class correlation coefficient ICC [95% confidence interval (CI)]; abduction: 0.803 [0.691; 0.877]; adduction: 0.705 [0.551; 0.813]) and intrarater reliabilities (ICC [95% CI]; abduction: 0.817 [0.712; 0.887]; adduction: 0.688 [0.529; 0.801]) were found. Differences in the translation range between the repeated measurements were not statistically significant (mean difference, interrater: abduction, -0.1 mm, p = 0.686; adduction, -0.1 mm, p = 0.466; intrarater: abduction 0.0 mm, p = 0.888; adduction, 0.2 mm, p = 0.275). This method is suitable for measuring inferior-superior glenohumeral translation in the scapular plane.

9.
Praxis (Bern 1994) ; 111(3): 113-121, 2022.
Article in German | MEDLINE | ID: mdl-35232261

ABSTRACT

CME Sonography 103: Subacromial Pain Syndrome (SAPS) and Subcoracoid Impingement (SCI) Abstract. Pain in the shoulder can have its origin in different structures of the shoulder joint or in affected periarticular structures. Therefore, it is important to be able to make a specific diagnosis and identify the exact pathology behind it in order to initiate the most appropriate individually precise treatment. In this review, we discuss possible causes of impingement of the shoulder.


Subject(s)
Shoulder Impingement Syndrome , Shoulder Joint , Humans , Shoulder , Shoulder Impingement Syndrome/diagnostic imaging , Shoulder Pain/diagnostic imaging , Shoulder Pain/etiology , Ultrasonography
10.
Praxis (Bern 1994) ; 109(16): 1241-1242, 2020.
Article in German | MEDLINE | ID: mdl-33292006

ABSTRACT

CME Sonography 95/Answers: Sonographic Differential Diagnosis of Anterior Shoulder Pain Abstract. Anterior shoulder pain is common, and, compared to high-resolution dynamic sonography, the clinical examination is usually not precise enough for the exact classification of the cause of the pain. In this review we discuss possible causes of anterior shoulder pain with special emphasis on the ultrasound diagnosis of causes of subcoracoidal impingement and of anterior snapping syndrome. We use high-resolution ultrasound images to illustrate various possible underlying pathologies in anterior shoulder pain.


Subject(s)
Shoulder Impingement Syndrome , Shoulder Joint , Diagnosis, Differential , Humans , Physical Examination , Shoulder Impingement Syndrome/diagnosis , Shoulder Pain/diagnostic imaging , Shoulder Pain/etiology , Ultrasonography
11.
Praxis (Bern 1994) ; 109(15): 1165-1176, 2020 Nov.
Article in German | MEDLINE | ID: mdl-33234045

ABSTRACT

CME Sonography 95: Sonographic Differential Diagnosis of Anterior Shoulder Pain Abstract. Anterior shoulder pain is common, and, compared to high-resolution dynamic sonography, the clinical examination is usually not precise enough for the exact classification of the cause of the pain. In this review we discuss possible causes of anterior shoulder pain with special emphasis on the ultrasound diagnosis of causes of subcoracoidal impingement and of anterior snapping syndrome. We use high-resolution ultrasound images to illustrate various possible underlying pathologies in anterior shoulder pain.


Subject(s)
Shoulder Impingement Syndrome , Shoulder Joint , Diagnosis, Differential , Humans , Physical Examination , Shoulder Impingement Syndrome/diagnosis , Shoulder Pain/diagnostic imaging , Shoulder Pain/etiology , Ultrasonography
13.
Praxis (Bern 1994) ; 107(9-10): 495-496, 2018 Apr.
Article in German | MEDLINE | ID: mdl-29690846
14.
Ultrasound Int Open ; 3(3): E107-E116, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28845477

ABSTRACT

Shoulder pathologies of the rotator cuff of the shoulder are common in clinical practice. The focus of this pictorial essay is to discuss the anatomical details of the rotator interval of the shoulder, correlate the anatomy with normal ultrasound images and present selected pathologies. We focus on the imaging of the rotator interval that is actually the anterosuperior aspect of the glenohumeral joint capsule that is reinforced externally by the coracohumeral ligament, internally by the superior glenohumeral ligament and capsular fibers which blend together and insert medially and laterally to the bicipital groove. In this article we demonstrate the capability of high-resolution musculoskeletal ultrasound to visualize the detailed anatomy of the rotator interval. MSUS has a higher spatial resolution than other imaging techniques and the ability to examine these structures dynamically and to utilize the probe for precise anatomic localization of the patient's pain by sono-palpation.

16.
Knee Surg Sports Traumatol Arthrosc ; 21(6): 1369-77, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23370984

ABSTRACT

PURPOSE: The best treatment for Achilles tendon (AT) ruptures remains controversial. Long-term follow-up with radiological and clinical measurements is needed. METHODS: In this retrospective multicentre cohort study, patients (n = 52) were assessed at a mean of 91 months follow-up after unilateral AT rupture treated by open, percutaneous or conservative (non-surgical) treatment. Demographic parameters, time off work, maximum calf circumference and clinical scores (ATRS, Hannover, AOFAS) were evaluated. Muscle volume and cross-sectional area of the calf and AT length were measured on MR images and were compared between groups and to each patient's healthy contralateral leg. RESULTS: Reduced muscle volume was found across all groups with a higher muscle volume in the conservative (729.9 ± 130.3 cm(3)) compared to the percutaneous group (675.9 ± 207.4 cm(3), p = 0.04). AT length was longer in the affected leg (198.4 ± 24.1 vs. 180.6 ± 25.0 mm, p < 0.0001) without difference in subgroup analysis. Clinically measured ankle dorsiflexion showed poor correlation with AT length (R (2) = 0.07, p = 0.008). Muscle volume strongly correlated with the cross-sectional area (R (2) = 0.6, p < 0.0001) but showed a weak correlation with the Hannover score (R (2) = 0.08, p = 0.048). Maximum calf circumference correlated with muscle volume (R (2) = 0.42, p < 0.0001). CONCLUSIONS: No significant difference between the treatment groups was found in muscle volume, AT length, clinical measures or days off work. Cross-sectional area and maximum calf circumference are cost-effective measurements and a good approximation of muscle volume and can thus be used in a clinical setting while clinical dorsiflexion should not be used.


Subject(s)
Achilles Tendon/injuries , Muscle, Skeletal/pathology , Tendon Injuries/physiopathology , Achilles Tendon/pathology , Achilles Tendon/surgery , Adult , Anatomy, Cross-Sectional , Cohort Studies , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Organ Size , Retrospective Studies , Rupture , Tendon Injuries/surgery , Tendon Injuries/therapy , Treatment Outcome , Young Adult
17.
Arch Orthop Trauma Surg ; 128(6): 613-20, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18297298

ABSTRACT

INTRODUCTION: Bone strength describes the resistance of bone against mechanical failure. Bone strength depends on both the amount of bone and the bone's quality, and the bone strength may be looked upon as a relevant parameter to judge an osteosynthesis' stability. Information about bone strength was barely available intraoperatively in the past. The previous work of our group reported on development and laboratory evaluation of mechanical torque measurement as a method for the intraoperative quantification of bone strength. With the clinical series presented here we intend to verify that the im gesamten Text DensiProbe instrumentation for intraoperative torque measurement and the related measurement method are eligible for intraoperative use based on the following criteria: application of the method may not create complications, the measurement can be performed by the surgeon himself and may only cause a limited increase in the procedure time. PATIENTS AND METHODS: From December 2006 until May 2007 ten patients with a pertrochanteric femoral fracture or a lateral femoral neck fracture eligible for stabilization with DHS were included in the study after having received informed consent. Any medication and comorbidity that might have influenced bone quality or bone mineral density (BMD) in these patients was documented. Bone strength was intraoperatively measured with DensiProbe. Complications that were obviously related with torque measurement were documented as well as any deviation from the suggested procedure; 6 and 12 weeks postoperative follow-up included clinical and radiological examination. The time required for torque measurement, the overall operating time and the number of persons present in the operating room were protocolled. BMD values of the contralateral femoral neck were postoperatively assessed by dual energy X-ray absorptiometry (DEXA) and compared to intraoperative peak torque values measured by DensiProbe. RESULTS: No major complication was observed during intraoperative application of DensiProbe by trained surgeons. The unintended extraction of the guide wire together with the torque measurement probe was reported only once and is looked upon as a minor complication. Fracture healing was uneventful in all patients. The mean time for torque measurement was 2.35 +/- 0.9 min accounting for 2.2 +/- 1.1% of total surgery time. The presence of an additional person was not required to perform torque measurement but to protocol the data. There was a tendency towards correlation between BMD values of the femoral neck and intraoperative peak torque values. DISCUSSION: The data presented clearly indicate that the DensiProbe instrumentation and measurement principle are eligible for routine intraoperative use by trained surgeons. Interpretation of possible correlations between BMD values measured by means of DEXA and the Peak Torque values assessed by DensiProbe has to be considered very carefully, because BMD and Peak Torque analyse bone at a different scale. Only within the framework of a multicenter study it will be possible to include a sufficient number of patients for calculation of the methods' predictive value towards implant failure and to verify acceptance of the method by the surgeons.


Subject(s)
Bone Density/physiology , Femoral Fractures/physiopathology , Femur/physiopathology , Torque , Adult , Aged , Biomechanical Phenomena , Bone Wires , Female , Femoral Fractures/surgery , Follow-Up Studies , Humans , Intraoperative Care , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...