Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 82
Filter
1.
Healthcare (Basel) ; 12(13)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38998857

ABSTRACT

This study provides a statistical forecast for the development of total elbow arthroplasties (TEAs) in Germany until 2045. The authors used an autoregressive integrated moving average (ARIMA), Error-Trend-Seasonality (ETS), and Poisson model to forecast trends in total elbow arthroplasty based on demographic information and official procedure statistics. They predict a significant increase in total elbow joint replacements, with a higher prevalence among women than men. Comprehensive national data provided by the Federal Statistical Office of Germany (Statistisches Bundesamt) were used to quantify TEA's total number and incidence rates. Poisson regression, exponential smoothing with Error-Trend-Seasonality, and autoregressive integrated moving average models (ARIMA) were used to predict developments in the total number of surgeries until 2045. Overall, the number of TEAs is projected to increase continuously from 2021 to 2045. This will result in a total number of 982 (TEAs) in 2045 of mostly elderly patients above 80 years. Notably, female patients will receive TEAs 7.5 times more often than men. This is likely influenced by demographic and societal factors such as an ageing population, changes in healthcare access and utilization, and advancements in medical technology. Our projection emphasises the necessity for continuous improvements in surgical training, implant development, and rehabilitation protocols.

2.
Article in English | MEDLINE | ID: mdl-38942223

ABSTRACT

OBJECTIVE: Coronal shear fractures of the capitellum are rare injuries which can be challenging to treat. The aim of this study was to compare the biomechanical properties of different internal screw fixation techniques for Dubberley type IA fractures of the capitellum. METHODS: In this biomechanical study, Dubberley type IA fractures of the capitellum were created in 30 human fresh-frozen humeri. The specimens were then divided into three groups: fixation was either performed with 3 x 3.0 mm headless cannulated compression screws (HCCSs) in anteroposterior (AP) orientation (AP group), 3 x 3.0 mm HCCSs in posteroanterior (PA) orientation (PA group) or with 2 x 3.0 mm HCCSs in PA orientation and 1 x 3.0 mm HCCS in lateral orientation (LAT group). Displacement under cyclic loading and ultimate load-to-failure were evaluated in all specimens. RESULTS: There was no significant difference in fragment displacement after 2000 cycles between AP and PA groups (0.8 ± 0.5 mm vs. 0.8 ± 0.6 mm; p = 0.987) or PA and LAT groups (0.8 ± 0.6 mm vs. 0.8 ± 0.3 mm; p = 0.966). LAT group showed the highest load-to-failure (548 ± 250 N) without reaching statistically significant difference to AP group (388 ± 173 N; p = 0.101). There was also no significant difference between AP and PA groups (388 ± 173 N vs. 422 ± 114 N; p = 0.649). CONCLUSIONS: Variations in screw placement had no statistically significant influence on cyclic displacement or load-to-failure in Dubberley Type IA fractures. However, fracture fixation in two planes - both the coronal and the sagittal plane - by adding a screw in a lateral to medial direction may be beneficial to increase primary stability.

3.
J Clin Med ; 13(8)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38673588

ABSTRACT

Background: The anatomical reconstruction of the wrist is the aim when treating distal radius fractures. Current literature on the importance of preoperative reduction in fractures that are treated operatively is limited. Methods: This study investigated the effect of the preoperative closed reduction of distal radius fractures on the day of trauma and the time to surgery on postoperative palmar inclination. A total of eighty patients (48 females and 32 males, mean age 55.6 years) were studied retrospectively. All patients were treated with an open reduction and internal fixation. The palmar inclination angle was measured using X-rays by two investigators, and the interobservers and pre- and post-reduction parameters were compared. Results: When the surgical management of closed distal radius fractures is required, neither initial repositioning nor a delay of up to 14 days to the surgical treatment influences postoperative palmar inclination. Conclusions: The significance of preoperative reduction of distal radius fractures without neurovascular or extensive soft tissue damage is limited and is not leading to improved outcomes. When surgery is about to be performed, surgeons should carefully consider if reduction is really vital preoperatively. Level of evidence: III.

4.
Injury ; 55(4): 111486, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38447478

ABSTRACT

OBJECTIVE: The trochlea is of great importance for the stability of the elbow and its fixation in low transcondylar fractures of the distal humerus is especially challenging. The aim of this study was to determine the optimal trochlea fixation in double plate osteosynthesis of intraarticular distal humerus fractures. METHODS: A low transcondylar, C3-type distal humerus fracture was created in 20 fresh-frozen human cadaveric humeri. The samples were then randomly divided into two groups of 10 specimens each. Double plate osteosynthesis was performed in both groups. In group A, the two most distal screws of the lateral plate were inserted into the trochlea fragment. In group B, these screws did not extend into the trochlea. Displacement under cyclic loading and ultimate failure loads were determined for all specimens. RESULTS: Group A showed significantly less displacement under cyclic loading in each measurement interval (0.92 mm vs. 1.53 mm after 100 cycles, p = 0 0.006; 1.10 mm vs. 1.84 mm after 1000 cycles, p = 0.007; 1.18 mm vs. 1.98 mm after 2000 cycles, p = 0.008). The ultimate failure load was significantly higher in group A than in group B (345.61 ± 120.389 N vs. 238.42 ± 131.61 N, p = 0.037). CONCLUSIONS: Fixation of the trochlea with interdigitating screws in double plate osteosynthesis of low-condylar type C distal humerus fractures results in superior construct stability. LEVEL OF EVIDENCE: not applicable (biomechanical).


Subject(s)
Humeral Fractures, Distal , Humeral Fractures , Humans , Humeral Fractures/surgery , Biomechanical Phenomena , Fracture Fixation, Internal/methods , Humerus/surgery , Bone Plates , Bone Screws , Cadaver
5.
Surg Radiol Anat ; 46(4): 473-482, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38329521

ABSTRACT

PURPOSE: Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS: 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS: RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION: This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.


Subject(s)
Elbow Joint , Ulnar Nerve , Male , Adult , Humans , Female , Ulnar Nerve/anatomy & histology , Elbow Joint/anatomy & histology , Elbow/innervation , Tomography, X-Ray Computed
6.
Arthrosc Tech ; 13(1): 102834, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38312892

ABSTRACT

Stiffness and pain secondary to end-stage dysfunctional osteoarthritis of the elbow can pose a therapeutic dilemma. Although total elbow arthroplasty is successful in older patients with low functional demand, alternatives to joint replacement must be found in the younger, more active individual. Interposition arthroplasty provides a salvage option for young, high-demand patients who hope to minimize functional restrictions of the affected extremity. The procedure traditionally involves release of both collateral ligaments and the joint capsule, resulting in a higher risk for postoperative instability and complications. The present unilateral technique demonstrates an approach maintaining the integrity of the medial or lateral collateral ligament while still allowing secure graft fixation. Stability can usually be preserved without ligament reconstruction or hinged external fixation if the elbow was stable before surgery.

7.
J Hand Surg Am ; 49(1): 8-14, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37978963

ABSTRACT

PURPOSE: The purpose of the study was to determine if the sphericity of the thumb metacarpophalangeal (MCP) joint influences the joint's rotational axis (RA) and elongation patterns of the ulnar collateral ligament (UCL). METHODS: Ulnar collateral ligament origins and attachments of 28 fresh-frozen cadaveric thumbs were marked with a radiopaque marker. Lateral radiographs were obtained in neutral and 20°, 40°, and 60° of flexion. The dorsal and palmar joint gap and the length of four different UCL portions were digitally measured in all flexion states. The RA was determined by the intersection of the midshaft axis of the proximal phalanx in neutral and flexion states. Sphericity of the MCP joint was assessed using morphometric parameters. Joints were grouped as round or flat. Differences in all measured parameters between groups were analyzed. RESULTS: During flexion, the dorsal joint gap increased by 322% in flat joints and 163% in round joints. The palmar joint gap decreased to 45% in flat joints and to 87% in round joints. The RA was at 29% of metacarpal height and 96% of metacarpal length in flat joints and at 40% of height and 86% of length in round joints. Maximum UCL elongation (111%) was noted at 40° flexion in the dorsal proper UCL in flat joints and at 60° flexion in the accessory UCL (117%) in round joints. CONCLUSIONS: In flat MCP joints, the RA is more dorsal and distal in the metacarpal head compared to round joints, resulting in a hinged flexion motion. Elongation of the UCL is highest at end flexion in round joints and highest at midflexion in flat joints. CLINICAL RELEVANCE: The different kinematics of flat and round MCP joints may contribute to the understanding of the pathophysiology of UCL ruptures. The propensity of this injury and the position in which they occur may be affected by the MCP joint morphology.


Subject(s)
Collateral Ligament, Ulnar , Collateral Ligaments , Humans , Thumb , Collateral Ligament, Ulnar/diagnostic imaging , Collateral Ligament, Ulnar/injuries , Collateral Ligaments/injuries , Biomechanical Phenomena , Metacarpophalangeal Joint
8.
Surg Radiol Anat ; 45(12): 1587-1592, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37837464

ABSTRACT

PURPOSE: A comprehensive analysis of the morphology of fractures of the coronoid process (CP) can aid diagnosis and guide treatment. The involvement of the radial notch of the ulna (RN)-e.g., in anterolateral facet fractures and transverse fractures of the CP-may influence the biomechanical conditions of the proximal radioulnar joint. However, the morphometric relation between the CP and the RN and the extent to what the proximal radioulnar joint can be affected in these types of fractures is unknown. METHODS: A total of 113 embalmed, cadaveric ulnae were dissected. All soft tissue was removed. Strictly lateral, high-resolution photographs were taken and digitally analyzed. The height of the CP and its relation to the RN was measured. Sex differences and correlations between measured parameters were calculated. RESULTS: Mean height of the CP was 16 mm (range: 12-23 mm; SD: 2). Mean height of the RN was 16 mm (11-25 mm; 2.2). The 50% mark of the CP corresponded to 18% (0-56%; 11.2) of the height of the RN. No significant differences were found between male and female specimens. CONCLUSION: The RN of the ulna extends only to a small part to the CP. Transverse or anterolateral fractures of less than 50% of the coronoid process may involve only a small portion of the proximal radioulnar joint.


Subject(s)
Elbow Joint , Radius Fractures , Ulna Fractures , Humans , Male , Female , Ulna/anatomy & histology , Elbow Joint/anatomy & histology , Upper Extremity
10.
J Biomech ; 158: 111766, 2023 09.
Article in English | MEDLINE | ID: mdl-37633217

ABSTRACT

Elbow trauma is often accompanied by a loss of independence in daily self-care activities, negatively affecting patients' quality of life. Finite element models can help gaining profound knowledge about native human joint mechanics, which is crucial to adequately restore joint functionality after severe injuries. Therefore, a finite element model of the elbow is required that includes both the radio-capitellar and ulno-trochlear joint and is subjected to loads realistic for activities of daily living. Since no such model has been published, we aim to fill this gap. For comparison, 8 intact cadaveric elbows were subjected to loads of up to 1000 N, after they were placed in an extended position. At each load step, the displacement of the proximal humerus relative to the distal base plate was measured with optical tracking markers and the joint pressure was measured with a pressure mapping sensor. Analogously, eight finite element models were created based on subject-specific CT scans of the corresponding elbow specimens. The CT scans were registered to the positions of tantalum beads in the experiment. The optically measured displacements were applied as boundary conditions. We demonstrated that the workflow can predict the experimental contact pressure distribution with a moderate correlation, the experimental peak pressures in the correct joints and the experimental stiffness with moderate to excellent correlation. The predictions of peak pressure magnitude, contact area and load share on the radius require improvement by precise representation of the cartilage geometry and soft tissues in the model, and proper initial contact in the experiment.


Subject(s)
Activities of Daily Living , Elbow , Humans , Finite Element Analysis , Quality of Life , Biomechanical Phenomena
11.
Arch Orthop Trauma Surg ; 143(10): 6201-6208, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37341804

ABSTRACT

INTRODUCTION: The SARS-CoV-2 pandemic and its associated lockdowns had a profound effect on orthopedic trauma emergencies. This study aimed to investigate the patient volume and injury patterns at a level-one trauma center during the SARS-CoV-2 pandemic and compare them to the pre-pandemic conditions. MATERIALS AND METHODS: A retrospective chart review of all patients who presented to the orthopedic trauma emergency department of a level-one trauma center in Cologne, Germany within a 2 year period from March 16th, 2019 to March 15th, 2020 (pre-pandemic control) and from March 16th, 2020 and March 15th, 2021 (pandemic) was performed. The pandemic year was separated into three periods: (1) first lockdown, (2) between lockdowns and (3) second lockdown. The absolute numbers of patient presentations, the Manchester triage score (MTS) and the relative proportion of patients with structural organ injuries, fractures and dislocations, of polytraumatized patients, of hospital admissions, of subsequent emergency or semi-elective surgeries and of work-related accidents were evaluated in comparison to the pre-pandemic control. RESULTS: A total of 21,642 patient presentations were included in this study. Significantly less weekly orthopedic trauma emergency patient presentations were recorded during the pandemic (p < 0.01). The MTS was significantly lower during the first lockdown and between lockdowns (p < 0.01). The proportional incidence of overall structural organ injuries, fractures and dislocations, of upper limb fractures/dislocations, of hospital admissions and of patients requiring surgery was significantly increased during the pandemic (p ≤ 0.03). The proportional incidence of work-related injuries was significantly decreased during the pandemic (p < 0.01). CONCLUSIONS: Orthopedic trauma emergency presentations were reduced during the SARS-CoV-2 pandemic. Due to the reluctancy of patients to visit the emergency department during the pandemic, the proportions of relevant injuries in general and of upper limb injuries in particular as well as of patients requiring hospital admission and trauma-related surgery were significantly increased.


Subject(s)
COVID-19 , Fractures, Bone , Joint Dislocations , Humans , SARS-CoV-2 , Trauma Centers , COVID-19/epidemiology , Pandemics/prevention & control , Retrospective Studies , Emergencies , Communicable Disease Control , Emergency Service, Hospital , Fractures, Bone/epidemiology , Fractures, Bone/surgery , Joint Dislocations/epidemiology
12.
Unfallchirurgie (Heidelb) ; 126(9): 694-699, 2023 Sep.
Article in German | MEDLINE | ID: mdl-37278730

ABSTRACT

So far there are no clear recommendations for postoperative follow-up treatment of elbow injuries and individual concepts are often chosen. Due to the susceptibility for posttraumatic or postoperative impaired movement up to stiffness of the elbow joint, early mobilization plays a crucial role. Therefore, mid-term to long-term immobilization should be avoided. In addition to the necessary cryotherapy and compression therapy for swelling and pain control in the initial period, early actively assisted mobilization now has an important role. Additionally, active flexion and extension in an overhead position, so-called overhead motion, was recently established. After a short initial immobilization in a cast, mostly 3-5 days, the cast is changed to a dynamic movement orthosis, which when possible enables a free range of motion. Care is taken that varus and valgus loading is avoided. In general loading is avoided for the first 6 weeks, followed by a stepwise increase of loading up to maximum loading. In most cases return to sport is possible after 3 months. After implantation of an elbow prosthesis a maximum loading of 5 kg for single loading and 1 kg for repetitive loading are recommended.


Subject(s)
Arm Injuries , Elbow Injuries , Elbow Joint , Humans , Follow-Up Studies , Elbow Joint/surgery , Movement
13.
Unfallchirurgie (Heidelb) ; 126(9): 687-693, 2023 Sep.
Article in German | MEDLINE | ID: mdl-37278731

ABSTRACT

The term Monteggia-like lesions or Monteggia equivalent injuries includes fractures of the proximal ulna with dislocation and dislocation fractures of the radial head from the proximal radio-ulnar joint. The complexity of the injury requires a dedicated understanding of the anatomical structures and their biomechanical properties. Particularly due to the rarity, the complication and revision rates are high. A conservative treatment is not usually effective. Three-dimensional imaging by computed tomography is part of the surgical preparation. The goal of surgical treatment is osteosynthetic reconstruction of the fractures and restoration of joint congruency. In cases of nonreconstructable radial head fractures, radial head arthroplasty may be necessary. In addition to reconstruction of the bony stabilizers, refixation of the ligamentous structures is essential for treatment success. The combination of complex fracture patterns and possible dislocation positions in the ulnohumeral, radiohumeral and proximal radio-ulnar joints poses a great challenge to the surgeon. The most frequent complications are peri-implant infections, implant failure, loss of reduction, stiffness or instability. Especially the anatomical configuration of the proximal ulna is complex and requires accurate reconstruction. Therefore, reconstruction of the proximal ulna in length and rotation, including the coronoid process, is considered to be a key factor in the surgical treatment of Monteggia-like injuries.


Subject(s)
Elbow Injuries , Elbow Joint , Joint Dislocations , Radius Fractures , Humans , Joint Dislocations/diagnostic imaging , Elbow Joint/surgery , Radius Fractures/surgery , Radius/injuries
14.
Unfallchirurgie (Heidelb) ; 126(9): 700-705, 2023 Sep.
Article in German | MEDLINE | ID: mdl-37270731

ABSTRACT

BACKGROUND: Monteggia-like fractures (MLF) are complex injuries with high complication rates and frequently unsatisfying clinical results. Total elbow arthroplasty (TEA) represents the only option to salvage the functional requirements in some patients with pronounced posttraumatic arthropathy. This case series provides clinical results of TEA following failed treatment of MLF. METHODS: All patients who underwent TEA from 2017 to 2022 for failed treatment of MLF were retrospectively included in this study. Complications and revisions before and after TEA and functional results, measured by the Broberg/Morrey score, were evaluated. RESULTS: In this study 9 patients with a mean age of 68 (±7; 54-79) years were included. The mean follow-up was 12 (±9; 2-27) months. The main reasons leading to posttraumatic arthropathy were chronic infections (44.4%), bony instability due to coronoid deficiency (33.3%) or a combined coronoid and radial head deficiency (22.2%) and non-union of the proximal ulna with radial head necrosis (11.1%). The mean number of surgical revisions between primary fixation and TEA was 2.7 (±1.8; 0-6). The revision rate following TEA was 44%. The mean Broberg/Morrey score at the time of the latest follow-up was 83 (±10; 71-97) points. CONCLUSION: Chronic infection and coronoid deficiency are the main reasons for posttraumatic arthropathy after MLF leading to TEA. While the overall clinical results are satisfying, the indications should be reserved for selected cases due to high revision rates.


Subject(s)
Arthritis , Arthroplasty, Replacement, Elbow , Monteggia's Fracture , Aged , Humans , Arthritis/etiology , Arthroplasty, Replacement, Elbow/adverse effects , Elbow/surgery , Fracture Fixation, Internal/adverse effects , Monteggia's Fracture/diagnostic imaging , Retrospective Studies , Treatment Failure , Treatment Outcome , Middle Aged
15.
J Hand Surg Eur Vol ; 48(8): 768-772, 2023 09.
Article in English | MEDLINE | ID: mdl-37005740

ABSTRACT

Studies on graft reconstruction techniques for ruptured thumb metacarpophalangeal (MCP) ulnar collateral ligaments (UCL) do not consider the variety of MCP joint morphology. Optimal reconstruction method for flat MCP joints is therefore unclear. Twenty-four fresh-frozen, human thumbs were tested for flexion, extension and valgus stability of the MCP joint. After resection of the UCL, four reconstruction methods, differing in the metacarpal origin and phalangeal attachment, were performed on each specimen, which were then tested again in the same way. Specimens were grouped as 'round' or 'flat' depending on morphometric parameters and group differences were analysed. In flat joints, only the non-anatomical Glickel reconstruction and a modified Fairhurst reconstruction maintained normal mobility and stability. In round joints, only the Glickel reconstruction maintained normal mobility and stability. The original Fairhurst method and a modification with the origin palmar in the metacarpus were disadvantageous in both flat and round joints.


Subject(s)
Collateral Ligament, Ulnar , Collateral Ligaments , Humans , Collateral Ligament, Ulnar/surgery , Thumb/surgery , Collateral Ligaments/surgery , Range of Motion, Articular , Metacarpophalangeal Joint/surgery
16.
Surg Radiol Anat ; 45(5): 571-580, 2023 May.
Article in English | MEDLINE | ID: mdl-36892617

ABSTRACT

The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79-0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately.


Subject(s)
Elbow Joint , Humerus , Adult , Humans , Reproducibility of Results , Humerus/diagnostic imaging , Tomography, X-Ray Computed , Elbow Joint/diagnostic imaging , Radiography
17.
Arch Orthop Trauma Surg ; 143(5): 2485-2491, 2023 May.
Article in English | MEDLINE | ID: mdl-35635575

ABSTRACT

BACKGROUND: Complex proximal humeral fracture ranks among the most common fracture types, especially in elderly patients. In locked plate fixation of proximal humerus fractures, the calcar is deciding for screws providing further medial column support. To date, the biomechanical effect of the length of these calcar screws is not well known. The purpose of this study was to analyze the effect of long calcar screws on fresh frozen prefractured cadaveric specimens. METHODS: In the present biomechanical study, 8 pairs of cadaveric proximal humeri were fractured identically using a custom-made fracture simulator. ORIF was performed using a locking plate (PHILOS; Fa. Synthes). The specimens were tested in a biomechanical setup under increased axial load without any calcar screws installed, with short calcar screws and long calcar screws installed. Strain gages (4-wire-120 Ohm, Fa. Vishay) mounted on the locking plate were used to evaluate the fixation strain and to give an estimate for primary stability.. RESULTS: The measured strain of the locking plate without calcar screws (804,64 µm/m) at maximum load (200 N) was significantly higher than with short (619,07 µm/m; p = 0.02) or long calcar screws (527,31 µm/m; p = 0.007). Additionally, strain with short calcar screws was noticeably higher in comparison to long calcar screws (619,07 µm/m vs. 527,31 µm/m; p = 0.03). CONCLUSION: Use of calcar screws improves the stability of realistically impacted 3-part varus humeral fractures. Long calcar screws that are positioned as close as possible to the joint provide further primary stability compared to short calcar screws. LEVEL OF EVIDENCE: Basic science study.


Subject(s)
Fracture Fixation, Internal , Shoulder Fractures , Humans , Aged , Bone Screws , Shoulder Fractures/surgery , Humerus/surgery , Bone Plates , Cadaver , Biomechanical Phenomena
18.
Arch Orthop Trauma Surg ; 143(5): 2467-2474, 2023 May.
Article in English | MEDLINE | ID: mdl-35579703

ABSTRACT

INTRODUCTION: In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. MATERIALS AND METHODS: Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer's classification was used to analyse the fractures. RESULTS: In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. CONCLUSION: A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education. LEVEL OF EVIDENCE: III.


Subject(s)
Humeral Fractures , Shoulder Fractures , Humans , Rotator Cuff/surgery , Shoulder Fractures/surgery , Shoulder , Humerus , Cadaver
19.
Arch Orthop Trauma Surg ; 143(5): 2519-2527, 2023 May.
Article in English | MEDLINE | ID: mdl-35731264

ABSTRACT

INTRODUCTION: Open reduction and internal fixation (ORIF) of comminuted coronal shear fractures of the distal humerus is challenging. When a concomitant lateral condyle fracture is present, it may be used for a trans-fracture approach to facilitate exposure and fracture reduction. This study aimed to investigate the frequency of lateral condyle fractures in coronal shear fractures of the distal humerus and analyze fracture reduction, fracture union and clinical results following ORIF through a trans-fracture approach. MATERIALS AND METHODS: All adult patients who underwent treatment for an acute distal humerus fracture during a three-year period in our level-one trauma center were identified. All fractures were classified according to the Orthopaedic Trauma Association (OTA/AO) fracture classification system and all B3 fractures were classified according to the Dubberley classification. B3 fractures with a concomitant radial condyle fracture were identified. The clinical and radiological results, (Mayo Elbow Performance Score = MEPS, Visual Analogue Scale = VAS, range of motion), complications and revision surgeries were analyzed. RESULTS: 53 patients (mean age 52 ± 19 years) were identified. 13 fractures (24.5%) were B3 fractures. Four of them (30.8%) had a concomitant radial condyle fracture. All of these patients underwent ORIF with headless cannulated compression screws and a (postero-)lateral locking plate through a trans-fracture approach. At a minimum follow-up of 24 months, the MEPS was 88 ± 12 points, the VAS was 2 ± 1 and the range of motion was 118° ± 12°. All fractures showed anatomic reduction. One patient developed partial avascular necrosis and underwent arthrolysis at 6 months. One patient underwent partial hardware removal and lateral collateral ligament bracing at 6 months. CONCLUSIONS: Lateral condyle fractures are present in about one third of coronal shear fractures of the distal humerus. This injury can be used for a trans-fracture approach to facilitate exposure and to reliably achieve anatomic fracture reduction.


Subject(s)
Elbow Joint , Fractures, Comminuted , Humeral Fractures , Adult , Humans , Middle Aged , Aged , Humeral Fractures/surgery , Fracture Fixation, Internal/methods , Humerus , Open Fracture Reduction/methods , Elbow Joint/surgery , Fractures, Comminuted/surgery , Treatment Outcome , Retrospective Studies , Range of Motion, Articular
20.
Arch Orthop Trauma Surg ; 143(2): 857-863, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35064826

ABSTRACT

BACKGROUND: Lateral collateral ligament (LCL) tears are frequently observed in fractures and dislocations of the elbow. Recent biomechanical evidence suggests that additional ligament augmentation may improve repair stability. The aim of this biomechanical in-vitro study was to compare the resistance of a locking suture repair of the LCL with a ligament augmentation technique. MATERIAL AND METHODS: Eight fresh frozen cadaveric elbows were evaluated for stability against varus/posterolateral rotatory forces (3 Nm). A strain gauge (µm/m; negative values) was placed at the origin and insertion of the lateral ulnar collateral ligament (LUCL) and cyclic loading was performed for 1000 cycles. We analyzed three distinct scenarios: (A) native LCL, (B) locking transosseou suture repair of the LCL, (C) simple LCL repair with additional ligament augmentation of the LUCL. RESULTS: The mean measured strain was - 416.1 µm/m (A), - 618 µm/m (B) and - 288.5 µm/m (C) with the elbow flexion at 90°; the strain was significantly higher in scenario B compared to C (p = .01). During the cyclic load (1000) the mean measured strain was - 523.1 µm/m (B) and - 226.3 µm/m (C) with the elbow flexion at 60°; the strain was significantly higher in scenario B compared to C (p = .01). No significant difference between the first and the last cycles was observed (p = .09; p = .07). One failure of the LCL repair was observed after 1000 cycles; none of the ligament augmentations failed. CONCLUSION: Ligament augmentation (C) provides higher resistance compared to the native LCL (A) and to the locking suture repair technique (B). Both techniques, however, hold up during 1000 cycles. While ligament augmentation might enhance the primary stability of the repair, future clinical studies have to show whether this increase in resistance leads to negative effects like higher rates of posttraumatic elbow stiffness. LEVEL OF EVIDENCE: Basic science study, biomechanics.


Subject(s)
Collateral Ligaments , Elbow Joint , Joint Instability , Lateral Ligament, Ankle , Humans , Elbow , Joint Instability/surgery , Elbow Joint/surgery , Range of Motion, Articular , Biomechanical Phenomena , Cadaver , Sutures , Collateral Ligaments/surgery , Collateral Ligaments/injuries
SELECTION OF CITATIONS
SEARCH DETAIL
...