Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
J Craniomaxillofac Surg ; 52(7): 829-834, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38637251

ABSTRACT

This study was aimed to assess whether facial asymmetry increases with age and to examine potential gender differences using 3D stereophotogrammetry. A prospective cross-sectional study was performed. 3D photographs were acquired from 600 control subjects, 300 male, 300 female, and were stratified into 15 different age groups ranging from 0 to 70+. The 3D photographs were postprocessed and mirrored. The original and mirrored faces were surface-based matched using an iterative closest point algorithm. The primary outcome variable, facial asymmetry, was evaluated by calculating the absolute mean distance between the original and mirrored images. The primary predictor was age. Pearson's correlation was used to assess the correlation between facial asymmetry and age. The average overall facial asymmetry was 0.72 mm (SD 0.72 mm; range 0.25 - 3.04 mm). Mean facial asymmetry increased significantly with age, from 0.45 mm in the age group of 0-4 years to 0.98 mm in the age group of 70+ (p<0.001). Facial asymmetry was positively correlated with age (Pearson's r = 0.55; p<0.001). Male subjects were significantly more asymmetric compared to females, 0.77 mm and 0.67 mm, respectively (p<0.001). This study indicates that facial asymmetry significantly increases with age and is significantly larger in males than in females.


Subject(s)
Facial Asymmetry , Imaging, Three-Dimensional , Photogrammetry , Humans , Male , Facial Asymmetry/diagnostic imaging , Facial Asymmetry/pathology , Female , Photogrammetry/methods , Adult , Imaging, Three-Dimensional/methods , Adolescent , Prospective Studies , Cross-Sectional Studies , Young Adult , Child , Middle Aged , Child, Preschool , Age Factors , Aged , Infant , Sex Factors , Infant, Newborn
2.
Ned Tijdschr Tandheelkd ; 129(7-8): 340-345, 2022 Jul.
Article in Dutch | MEDLINE | ID: mdl-35833283

ABSTRACT

Genioplasty is a seemingly simple procedure performed to correct the bony chin. The results of the procedure are, however, strongly correlated with the experience of the surgeon. 3D-printed surgical guides could act as a transfer modality to translate the preoperative planning directly into the achieved result. Prospective studies evaluating the usefulness of the 3D-printed surgical guides have not yet been carried out and consensus regarding the best design is lacking. In order to become more familiar with working with surgical guides, a genioplasty using 3D-printed surgical guides was performed. The postoperative analysis of the achieved result showed minor differences compared to preoperative planning. Surgical guides have the potential to improve the accuracy and predictability of genioplasty. The design should be further refined and the added value of the guides should be confirmed by means of prospective research.


Subject(s)
Genioplasty , Surgery, Computer-Assisted , Chin , Genioplasty/methods , Humans , Printing, Three-Dimensional , Prospective Studies , Surgery, Computer-Assisted/methods
3.
Int J Oral Maxillofac Surg ; 51(2): 263-268, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33933335

ABSTRACT

The aim of this study was to evaluate a novel soft tissue-based method to register an intraoral scan (IOS) with a cone beam computed tomography (CBCT) scan. IOS and CBCT data were obtained from eight dentate patients (mean age 21±2 years; three male, five female) and 14 fully edentulous patients (mean age 56±9 years; eight male, six female). An algorithm was developed to create a soft tissue model of the CBCT scan, which allowed a soft tissue-based registration to be performed with the IOS. First, validation was performed on dentate jaws with registration of the palatal mucosal surface and accuracy evaluation at the level of the teeth. Second, fully edentulous jaws were registered using both the palatal and alveolar crest mucosal surfaces. Distance maps were created to measure the method accuracy. The mean registration error was 0.49±0.26mm for the dentate jaws. Registration of the fully edentulous jaws had a mean error of 0.16±0.08mm at the palate and 0.16±0.05mm at the alveolar crest. In conclusion, the high accuracy of this registration method may allow the digital workflow to be optimized when no teeth are available to perform a regular registration procedure.


Subject(s)
Jaw, Edentulous , Mouth, Edentulous , Adult , Aged , Algorithms , Cone-Beam Computed Tomography , Female , Humans , Imaging, Three-Dimensional , Jaw, Edentulous/diagnostic imaging , Male , Middle Aged , Young Adult
4.
Int J Oral Maxillofac Surg ; 51(6): 790-798, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34763984

ABSTRACT

In orbital reconstruction, a patient-specific implant (PSI) may provide accurate reconstruction in complex cases, since the design can be tailored to the anatomy. Several design options may be embedded, for ease of positioning and precision of reconstruction. This study describes a cohort of 22 patients treated for secondary orbital reconstruction with a PSI; one patient received two PSI. The preoperative clinical characteristics and implant design options used are presented. When compared to preoperative characteristics, the postoperative clinical outcomes showed significant improvements in terms of enophthalmos (P < 0.001), diplopia (P < 0.001), and hypoglobus (P = 0.002). The implant position in all previous reconstructions was considered inadequate. Quantitative analysis after PSI reconstruction showed accurate positioning of the implant, with small median and 90th percentile deviations (roll: median 1.3°, 90th percentile 4.6°; pitch: median 1.4°, 90th percentile 3.9°; yaw: median 1.0°, 90th percentile 4.4°; translation: median 1.4 mm, 90th percentile 2.7 mm). Rim support proved to be a significant predictor of roll and rim extension for yaw. No significant relationship between design options or PSI position and clinical outcomes could be established. The results of this study show the benefits of PSI for the clinical outcomes in a large cohort of secondary post-traumatic orbital reconstructions.


Subject(s)
Dental Implants , Enophthalmos , Orbital Fractures , Orbital Implants , Plastic Surgery Procedures , Diplopia/etiology , Diplopia/surgery , Enophthalmos/etiology , Enophthalmos/surgery , Humans , Orbit/surgery , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Plastic Surgery Procedures/methods
5.
Int J Oral Maxillofac Surg ; 51(7): 922-928, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34952772

ABSTRACT

The aim of this study was to assess whether the use of intraoral scans (IOS) is an eligible alternative to conventional plaster casts in terms of surgical accuracy of three-dimensionally planned bimaxillary osteotomies. This retrospective cohort study included patients who underwent bimaxillary surgery between 2016 and 2020 in the Department of Oral and Maxillofacial Surgery at Radboud University Medical Center, Nijmegen. Three-dimensional virtual planning was performed with the use of plaster casts in one group and IOS in the other group. Cone beam computed tomography scans were acquired preoperatively and at 1 week following surgery. By using voxel-based matching, the maxillary movements were quantified in six degrees of freedom. The primary outcome variable, surgical accuracy, was defined as the difference between the planned maxillary movements and those achieved. Of 152 patients, 113 were documented with plaster casts and 39 with IOS. The surgical accuracy was comparable in terms of maxillary vertical, sagittal, and transverse translations, as well as roll and yaw. Maxillary pitch (difference 0.55 ± 0.26°; P = 0.001) was in favour of the IOS group. This study demonstrated that IOS can be used as an alternative to conventional plaster casts in the three-dimensional planning of bimaxillary osteotomies.


Subject(s)
Orthognathic Surgical Procedures , Casts, Surgical , Cone-Beam Computed Tomography , Dentition , Humans , Imaging, Three-Dimensional , Maxilla/diagnostic imaging , Maxilla/surgery , Retrospective Studies
6.
Sci Rep ; 11(1): 18080, 2021 09 10.
Article in English | MEDLINE | ID: mdl-34508161

ABSTRACT

The accuracy of intra-operative navigation is largely dependent on the intra-operative registration procedure. Next to accuracy, important factors to consider for the registration procedure are invasiveness, time consumption, logistical demands, user-dependency, compatibility and radiation exposure. In this study, a workflow is presented that eliminates the need for a registration procedure altogether: registration-free navigation. In the workflow, the maxillary dental model is fused to the pre-operative imaging data using commercially available virtual planning software. A virtual Dynamic Reference Frame on a splint is designed on the patient's fused maxillary dentition: during surgery, the splint containing the reference frame is positioned on the patient's dentition. This alleviates the need for any registration procedure, since the position of the reference frame is known from the design. The accuracy of the workflow was evaluated in a cadaver set-up, and compared to bone-anchored fiducial, virtual splint and surface-based registration. The results showed that accuracy of the workflow was greatly dependent on tracking technique used: the workflow was the most accurate with electromagnetic tracking, but the least accurate with optical tracking. Although this method offers a time-efficient, non-invasive, radiation-free automatic alternative for registration, clinical implementation is hampered by the unexplained differences in accuracy between tracking techniques.


Subject(s)
Head/diagnostic imaging , Head/surgery , Ophthalmologic Surgical Procedures/methods , Surgery, Computer-Assisted/methods , Cadaver , Humans , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Workflow
7.
Br J Oral Maxillofac Surg ; 59(7): 826-830, 2021 09.
Article in English | MEDLINE | ID: mdl-34256960

ABSTRACT

Adequate positioning of an orbital implant during orbital reconstruction surgery is essential for restoration of the pre-traumatised anatomy, but visual appraisal of its position is limited by the keyhole access and protruding soft tissues. A positioning instrument that attaches to the implant was designed to provide feedback outside the orbit. The goal of this study was to evaluate the accuracy of placement with the instrument and compare it with the accuracy of placement by visual appraisal. Ten orbits in five human cadaver heads were reconstructed twice: once using visual appraisal and once using the instrument workflow. No significant improvement was found for the roll (5.8° vs 3.4°, respectively, p=0.16), pitch (2.1° vs 1.5°, p=0.56), or translation (2.9 mm vs 3.3 mm, p=0.77), but the yaw was significantly reduced if the instrument workflow was used (15.3° vs 2.9°, p=0.02). The workflow is associated with low costs and low logistical demands, and may prevent outliers in implant positioning in a clinical setting when intraoperative navigation or patient-specific implants are not available.


Subject(s)
Dental Implants , Orbital Fractures , Plastic Surgery Procedures , Surgery, Computer-Assisted , Feasibility Studies , Humans , Orbit/surgery , Orbital Fractures/surgery , Surgical Instruments
8.
Heliyon ; 7(7): e07447, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34286125

ABSTRACT

INTRODUCTION: In Sierra Leone, access to prostheses is limited due to absence of practical knowledge, materials, trained staff, and high cost. This paper investigates the impact of a 3D printed prosthesis on the health-related quality of life (HRQoL) in prosthesis recipients. METHODS: Patients with upper extremity amputations were included in this case study from December 2018 until July 2019. Data on the HRQoL was gathered until April 2020 in Masanga Hospital, central rural Sierra Leone. At two follow-up moments the HRQoL was assessed by applying the standard EQ-5D-5L questionnaire. These two follow-up moments varied between one week and just over a year after receiving the prosthesis. A second patient questionnaire was used to assess prosthesis satisfaction. RESULTS: Seven patients were included. The results of the EQ-5D-5L questionnaire show no deterioration of the HRQoL in any patient and the overall HRQoL increased by almost 20% compared to the null measurement. One patient was lost to follow up after the first re-visit. The responses to the second questionnaire indicated that patients are satisfied with the prosthesis and use it in various situations. Patients often mentioned they feel more included in society when wearing the prosthesis. One patient says wearing the prosthesis helped in accepting the amputation. As a result, enough self-confidence was experienced without the prosthesis and the patients stopped wearing the prosthesis. DISCUSSION: The overall HRQoL in patients wearing a 3D-printed prosthesis increases compared to not wearing one. Assessing the HRQoL at regular intervals is important for the long-term follow-up and to safeguard sustainability and long-term success of this project. Nevertheless, defining the HRQoL is challenging due to cultural differences and misunderstandings. Therefore, the use of alternative questionnaires to define the HRQoL should be investigated. To improve and warrant long-term success, identifying long-term problems is important, and the second questionnaire accounts for this need.

9.
Sci Rep ; 11(1): 10406, 2021 05 17.
Article in English | MEDLINE | ID: mdl-34001966

ABSTRACT

In intra-operative navigation, a registration procedure is performed to register the patient's position to the pre-operative imaging data. The registration process is the main factor that determines accuracy of the navigation feedback. In this study, a novel registration protocol for craniofacial surgery is presented, that utilizes a virtual splint with marker points. The accuracy of the proposed method was evaluated by two observers in five human cadaver heads, for optical and electromagnetic navigation, and compared to maxillary bone-anchored fiducial registration (optical and electromagnetic) and surface-based registration (electromagnetic). The results showed minimal differences in accuracy compared to bone-anchored fiducials at the level of the infra-orbital rim. Both point-based techniques had lower error estimates at the infraorbital rim than surface-based registration, but surface-based registration had the lowest loss of accuracy over target distance. An advantage over existing point-based registration methods (bone-anchored fiducials, existing splint techniques) is that radiological imaging does not need to be repeated, since the need for physical fiducials to be present in the image volume is eradicated. Other advantages include reduction of invasiveness compared to bone-achnored fiducials and a possible reduction of human error in the registration process.


Subject(s)
Fiducial Markers , Imaging, Three-Dimensional/instrumentation , Patient Positioning/methods , Splints , Surgery, Computer-Assisted/methods , Anatomic Landmarks , Cadaver , Electromagnetic Phenomena , Humans , Imaging, Three-Dimensional/methods , Maxilla/anatomy & histology , Maxilla/diagnostic imaging , Maxilla/surgery , Orbit/anatomy & histology , Orbit/diagnostic imaging , Orbit/surgery , Tomography, X-Ray Computed/methods
10.
Clin Oral Investig ; 25(1): 77-85, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32495223

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the clinical accuracy of the fusion of intra-oral scans in cone-beam computed tomography (CBCT) scans using two commercially available software packages. MATERIALS AND METHODS: Ten dry human skulls were subjected to structured light scanning, CBCT scanning, and intra-oral scanning. Two commercially available software packages were used to perform fusion of the intra-oral scans in the CBCT scan to create an accurate virtual head model: IPS CaseDesigner® and OrthoAnalyzer™. The structured light scanner was used as a gold standard and was superimposed on the virtual head models, created by IPS CaseDesigner® and OrthoAnalyzer™, using an Iterative Closest Point algorithm. Differences between the positions of the intra-oral scans obtained with the software packages were recorded and expressed in six degrees of freedom as well as the inter- and intra-observer intra-class correlation coefficient. RESULTS: The tested software packages, IPS CaseDesigner® and OrthoAnalyzer™, showed a high level of accuracy compared to the gold standard. The accuracy was calculated for all six degrees of freedom. It was noticeable that the accuracy in the cranial/caudal direction was the lowest for IPS CaseDesigner® and OrthoAnalyzer™ in both the maxilla and mandible. The inter- and intra-observer intra-class correlation coefficient showed a high level of agreement between the observers. CLINICAL RELEVANCE: IPS CaseDesigner® and OrthoAnalyzer™ are reliable software packages providing an accurate fusion of the intra-oral scan in the CBCT. Both software packages can be used as an accurate fusion tool of the intra-oral scan in the CBCT which provides an accurate basis for 3D virtual planning.


Subject(s)
Cone-Beam Computed Tomography , Imaging, Three-Dimensional , Humans , Mandible/diagnostic imaging , Maxilla , Software
11.
Int J Oral Maxillofac Surg ; 50(9): 1219-1225, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33358521

ABSTRACT

The aim of this retrospective study was to determine whether a virtually created occlusion is as accurate as a conventionally created occlusion. Seventeen orthognathic patients were included in the study, which was conducted in a university clinic. Plaster cast models were obtained and digitized. Two experienced observers created the conventional (gold standard) and virtual occlusion to assess inter-observer variability. One observer created the conventional and virtual occlusion a second time to assess the intra-observer variability. The criterion for accepting the virtual occlusion was that the difference between the gold standard and the virtual occlusion was not larger than the intra-observer variability for the gold standard. A non-parametric Kruskal-Wallis H test was performed to detect statistically significant differences between the intra- and inter-observer groups for both the conventional and virtual occlusion. No statistically significant differences were found between the different groups. The difference between the conventional and virtual occlusion group was 0.20mm larger than the intra-observer variability of the gold standard. The virtual occlusion tool presented here can be utilized in daily clinical practice and makes the use of physical dental models redundant.


Subject(s)
Orthognathic Surgery , Orthognathic Surgical Procedures , Humans , Imaging, Three-Dimensional , Models, Dental , Retrospective Studies
12.
Int J Oral Maxillofac Surg ; 50(6): 835-842, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33069517

ABSTRACT

The aim of this study was to evaluate three-dimensional (3D) stereophotogrammetry based methods for measuring craniofacial asymmetry in patients with congenital muscular torticollis (CMT). This study focused on the differences in craniofacial asymmetry in CMT patients compared with a healthy control group using 3D photographs. The difference in facial asymmetry between the CMT group and control group was measured using two methods to analyse facial asymmetry in distinct anatomical regions: (1) mirroring and surface-based registration to analyse the overall facial asymmetry; (2) the 'coherent point drift' based method. Thirty-one patients with CMT and 84 controls were included in the study. A statistically significant difference was found between the CMT patients and a healthy control group. The measured facial asymmetry for the CMT group was 1.71±0.66mm and for the controls 0.46±0.14mm (P<0.05). A significant difference was found in surface ratio for the cheek, nose and the forehead region (P<0.05). With its minimal invasive character, 3D stereophotogrammetry is a useful tool in measuring the facial asymmetry associated with CMT and to quantify the treatment-induced facial changes. In the future 3D facial data could be used to create a ranking-scale to categorize the severity of facial asymmetry.


Subject(s)
Facial Asymmetry , Torticollis , Face/diagnostic imaging , Facial Asymmetry/diagnostic imaging , Humans , Photogrammetry , Torticollis/congenital , Torticollis/diagnostic imaging
13.
Int J Oral Maxillofac Surg ; 50(2): 267-272, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32605823

ABSTRACT

The aim of this study was to determine the amount of deviation in nasolabial shape in patients with a cleft compared with an average non-cleft face, and to assess whether this difference is related to nasolabial aesthetics. Three-dimensional stereophotogrammetric images of 60 patients with a unilateral cleft were used. To quantify shape differences, four average non-cleft faces were constructed from stereophotogrammetric images of 141 girls and 60 boys. Three-dimensional shape differences were calculated between superimposed cleft faces and the average non-cleft face for the same sex and age group. Nasolabial aesthetics were rated with the modified Asher-McDade Aesthetic Index using a visual analogue scale (VAS). Mean VAS scores ranged from 51.44 to 60.21 for clefts, with lower aesthetic ratings associated with increasing cleft severity. Shape differences were found between cleft faces and the average non-cleft face. No relationship was found for the VAS, age, and sex, except that a lower VAS was related to a higher nose and lip distance between the superimposed cleft and average non-cleft faces for nasal profile (P= 0.02), but the explained variance was low (R2=0.066). In conclusion, except for nasal profile, nasolabial aesthetics were not influenced by the extent of shape differences from the average non-cleft face.


Subject(s)
Cleft Lip , Cleft Palate , Esthetics, Dental , Female , Humans , Imaging, Three-Dimensional , Male , Nose
14.
Int J Oral Maxillofac Surg ; 50(1): 38-42, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32593512

ABSTRACT

Monitoring vascular perfusion of transferred tissue is essential in reconstructive surgery to recognize early flap failure. The aim of this study was to evaluate the ability of a digital surface scanner to detect vascular perfusion disorders through the monitoring of skin colour changes. A total of 160 surface scans of the forearm skin were performed with a TRIOS 3D scanner. Vascular compromise was simulated at different time-points by intermittent occlusion of the blood supply to the forearm skin (first the arterial blood supply and then the venous blood supply). Skin colour changes were examined according to the hue, saturation, and value colour scale. Colour differences were analysed with a paired t-test. Significant differences were observed between the colour of the normal skin and that of the vascular compromised skin (P<0.01). The surface scanner could distinguish between arterial occlusion and venous congestion (P<0.01). A digital surface scan is an objective, non-invasive tool to detect early vascular perfusion disorders of the skin.


Subject(s)
Plastic Surgery Procedures , Surgical Flaps , Forearm/surgery , Humans , Perfusion , Veins
15.
Clin Oral Investig ; 25(3): 1069-1076, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32583240

ABSTRACT

OBJECTIVES: The purpose of this study was to quantify the symmetry of the alveolar process of the maxilla and palate during the first year of life in healthy infants with the help of a semiautomatic segmentation technique. MATERIALS AND METHODS: Maxillary plaster models of seventy healthy babies at 0, 3, 6, 9, and 12 months were collected and digitized. A semiautomatic segmentation tool was used to extract the alveolus and palate. The resulting model was aligned within a reference frame and mirrored on its medial plane. Distance maps were created and analyzed to compare and quantify the differences between the two hemispheres. Additional hemispherical width and area measurements were performed. An ANOVA test with additional post hoc tests was performed to check if the symmetry changed during development. Finally, the results were tested on intra- and interobserver variability. RESULTS: The absolute mean inter-surface distance between the original and mirrored models in each age group ranged between 0.23 and 0.30 mm. Width and area analysis showed a small but significant larger left palatal hemisphere. ANOVA and post hoc tests showed no significant difference in symmetry between groups. Reliability analysis showed no significant differences between observers. CONCLUSIONS: This study showed that in this infant population, only a small degree of palatal asymmetry was present, which can be considered as normal and clinically irrelevant. CLINICAL RELEVANCE: The data from this study can be used in future comparative studies as reference data. Furthermore, modeling of these data can help in predicting the growth pattern, which may lead to improved treatment protocols for children with craniofacial anomalies.


Subject(s)
Cleft Palate , Dental Arch , Child , Humans , Infant , Maxilla , Reproducibility of Results
16.
J Neurol ; 268(4): 1342-1350, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33113021

ABSTRACT

OBJECTIVE: To evaluate facial weakness in patients with FSHD to better define clinical signs, and pilot a facial weakness severity score. METHODS: 87 FSHD patients and 55 controls were video recorded while performing seven facial tasks. The videos were assessed by three independent examiners to compile an overview of signs of facial weakness. Next, videos were semi-quantitatively assessed using a newly developed 4-point facial weakness score (FWS). This score was evaluated and correlated to other FSHD disease characteristics. RESULTS: Patients had lower scores on the total FWS than controls (mean score 43 ± 28, range 4-118, vs 14 ± 9, range 0-35, p < 0.001) and on all seven individual facial tasks (all p < 0.001). 54% of patients had FWS scores outside the range of controls. Patients had more asymmetry between the left and right side of the face than controls. About 10% of the patients had very mild facial weakness. These were mostly males (89%) with longer D4Z4 repeat sizes of 7-9 units. More severe facial weakness correlated to more severe overall disease severity and shorter D4Z4 repeat size, but not to disease duration. Interobserver agreement for the FWS between three raters was low with a Fleiss Kappa of 0.437. CONCLUSION: This study provides an overview of the clinical spectrum of facial weakness and its relation to other disease characteristics. The 4-point scale we introduced to grade the severity of facial weakness enables correlation of facial weakness to disease characteristics, but is not suited as clinical outcome measure for longitudinal studies.


Subject(s)
Muscular Dystrophy, Facioscapulohumeral , Face , Female , Humans , Longitudinal Studies , Male , Muscular Dystrophy, Facioscapulohumeral/complications , Muscular Dystrophy, Facioscapulohumeral/diagnosis , Severity of Illness Index
17.
Br J Oral Maxillofac Surg ; 58(7): 801-806, 2020 09.
Article in English | MEDLINE | ID: mdl-32381387

ABSTRACT

Intraoperative imaging enables the surgeon to control the position of the implant during orbital reconstruction. Although it might improve surgical outcome and avoid the need for revision surgery, it may also increase the duration of the operation and the exposure to radiation. The goal of this study was to find out whether intraoperative imaging improves the position of the implant in reconstructions of the orbital floor and medial wall. Two surgeons reconstructed complex orbital fractures in 10 cadavers. After the reconstruction a computed tomographic scan was made to confirm the position of the implant and, if required, to make any adjustments. Scans were repeated until the surgeon was satisfied. The ideal position was ascertained by scans that were obtained before and after creation of the fractures. The position of the implant achieved was compared with that of the ideal position of the implant, and improved significantly for yaw (p=0.04) and roll (p=0.03). A mean of 1.6 scans was required for each reconstruction (maximum n=3). The main reason for alteration was the rotation roll. Intraoperative imaging significantly improves the position of the implant in fractures of the orbital floor and medial wall. The surgeon has quality control of its position during the reconstruction to restore the anatomical boundaries.


Subject(s)
Dental Implants , Orbital Fractures , Plastic Surgery Procedures , Surgery, Computer-Assisted , Humans , Orbit/surgery , Orbital Fractures/surgery
18.
Ned Tijdschr Tandheelkd ; 127(3): 171-176, 2020 Mar.
Article in Dutch | MEDLINE | ID: mdl-32343277

ABSTRACT

3D virtual planning optimises the predictability of orthognathic surgery. The planning is based on a cone beam computed tomography-scan of the patient as well as a plaster model, and is transferred to the patient by a 3D printed occlusal splint. In 3D printing the build angle influences, among other things, the accuracy (in earlier research, proven in dental crowns), manufacturing time and capacity. In this research, using 10 plaster models, 3 different build angles (0°, 30° and 90°) are compared. The fit of the splints was tested by 2 physicians using plaster models. According to this small sample, the fit does not depend on the build angle. When considering the manufacturing time and capacity, there is a preference for the 90º oriëntation, because it increases the manufacturing capacity and decreases the manufacturing time per splint.


Subject(s)
Occlusal Splints , Orthognathic Surgical Procedures , Computer-Aided Design , Crowns , Humans , Imaging, Three-Dimensional , Printing, Three-Dimensional
19.
Int J Oral Maxillofac Surg ; 49(4): 454-460, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31506186

ABSTRACT

The accuracy of orthognathic surgery has improved with three-dimensional virtual planning. The translation of the planning to the surgical result is reported to vary by >2mm. The aim of this randomized controlled multi-centre trial was to determine whether the use of splintless patient-specific osteosynthesis can improve the accuracy of maxillary translation. Patients requiring a Le Fort I osteotomy were included in the trial. The intervention group was treated using patient-specific osteosynthesis and the control group with conventional osteosynthesis and splint-based positioning. Fifty-eight patients completed the study protocol, 27 in the patient-specific osteosynthesis group and 31 in the control group. The per protocol median anteroposterior deviation was found to be 1.05mm (interquartile range (IQR) 0.45-2.72mm) in the patient-specific osteosynthesis group and 1.74mm (IQR 1.02-3.02mm) in the control group. The cranial-caudal deviation was 0.87mm (IQR 0.49-1.44mm) and 0.98mm (IQR 0.28-2.10mm), respectively, whereas the left-right translation deviation was 0.46mm (IQR 0.19-0.96mm) in the patient-specific osteosynthesis group and 1.07mm (IQR 0.62-1.55mm) in the control group. The splintless patient-specific osteosynthesis method improves the accuracy of maxillary translations in orthognathic surgery and is clinically relevant for planned anteroposterior translations of more than 3.70mm.


Subject(s)
Orthognathic Surgical Procedures , Surgery, Computer-Assisted , Computer-Aided Design , Humans , Imaging, Three-Dimensional , Maxilla , Osteotomy, Le Fort
20.
Clin Oral Investig ; 24(7): 2385-2393, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31720852

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the clinical accuracy of virtual orthodontic setups by using a new CBCT-based approach. MATERIALS AND METHODS: Ten patients who underwent pre-surgical orthodontics were included in this study. Pre-treatment and pre-surgical cone-beam CT (CBCT) scans and digital dental models were available. The pre-treatment digital dental model was used to create an orthodontic virtual setup. The digital dental models were fused with the corresponding CBCT scans, and the two CBCT scans were aligned using voxel-based matching. Moving each individual tooth from the virtual setup to the final outcome allows the calculation of the accuracy of the virtual setup by using an iterative closest point algorithm. Differences between virtual setup and final outcome were recorded as well as the ICC between two observers. RESULTS: The inter-observer variability showed a high level of agreement between the observers. The largest mean difference between observers was found in the cranial/caudal direction (0.36 ± 0.30 mm) and the roll rotation (1.54 ± 0.98°). Differences between the virtual setup and final outcome were small in the translational direction (0.45 ± 0.48 mm). Rotational mean differences were larger with the pitch of the incisors (0.00 ± 7.97°) and molars (0.01 ± 10.26°) as largest difference. Excessive extrusion of all upper teeth and more anterior movement than planned were seen for both upper and lower arch. Lower molars showed less extrusion. CLINICAL RELEVANCE: The data of this study can be used to obtain more insight in the accuracy and achievability of orthodontic virtual setup. Tooth movement can now be studied in more details which can lead to new insights.


Subject(s)
Orthodontics , Tooth Movement Techniques , User-Computer Interface , Cone-Beam Computed Tomography , Humans , Imaging, Three-Dimensional , Incisor , Molar
SELECTION OF CITATIONS
SEARCH DETAIL
...