Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Eur Radiol ; 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38907886

ABSTRACT

OBJECTIVES: To assess 3-Tesla (3-T) ultra-small superparamagnetic iron oxide (USPIO)-enhanced MRI in detecting lymph node (LN) metastases for resectable adenocarcinomas of the pancreas, duodenum, or periampullary region in a node-to-node validation against histopathology. METHODS: Twenty-seven consecutive patients with a resectable pancreatic, duodenal, or periampullary adenocarcinoma were enrolled in this prospective single expert centre study. Ferumoxtran-10-enhanced 3-T MRI was performed pre-surgery. LNs found on MRI were scored for suspicion of metastasis by two expert radiologists using a dedicated scoring system. Node-to-node matching from in vivo MRI to histopathology was performed using a post-operative ex vivo 7-T MRI of the resection specimen. Sensitivity and specificity were calculated using crosstabs. RESULTS: Eighteen out of 27 patients (median age 65 years, 11 men) were included in the final analysis (pre-surgery withdrawal n = 4, not resected because of unexpected metastases peroperatively n = 2, and excluded because of inadequate contrast-agent uptake n = 3). On MRI 453 LNs with a median size of 4.0 mm were detected, of which 58 (13%) were classified as suspicious. At histopathology 385 LNs with a median size of 5.0 mm were found, of which 45 (12%) were metastatic. For 55 LNs node-to-node matching was possible. Analysis of these 55 matched LNs, resulted in a sensitivity and specificity of 83% (95% CI: 36-100%) and 92% (95% CI: 80-98%), respectively. CONCLUSION: USPIO-enhanced MRI is a promising technique to preoperatively detect and localise LN metastases in patients with pancreatic, duodenal, or periampullary adenocarcinoma. CLINICAL RELEVANCE STATEMENT: Detection of (distant) LN metastases with USPIO-enhanced MRI could be used to determine a personalised treatment strategy that could involve neoadjuvant or palliative chemotherapy, guided resection of distant LNs, or targeted radiotherapy. REGISTRATION: The study was registered on clinicaltrials.gov NCT04311047. https://clinicaltrials.gov/ct2/show/NCT04311047?term=lymph+node&cond=Pancreatic+Cancer&cntry=NL&draw=2&rank=1 . KEY POINTS: LN metastases of pancreatic, duodenal, or periampullary adenocarcinoma cannot be reliably detected with current imaging. This technique detected LN metastases with a sensitivity and specificity of 83% and 92%, respectively. MRI with ferumoxtran-10 is a promising technique to improve preoperative staging in these cancers.

2.
NMR Biomed ; : e5180, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38775032

ABSTRACT

Ultrahigh field magnetic resonance imaging (MRI) (≥ 7 T) has the potential to provide superior spatial resolution and unique image contrast. Apart from radiofrequency transmit inhomogeneities in the body at this field strength, imaging of the upper abdomen faces additional challenges associated with motion-induced ghosting artifacts. To address these challenges, the goal of this work was to develop a technique for high-resolution free-breathing upper abdominal MRI at 7 T with a large field of view. Free-breathing 3D gradient-recalled echo (GRE) water-excited radial stack-of-stars data were acquired in seven healthy volunteers (five males/two females, body mass index: 19.6-24.8 kg/m2) at 7 T using an eight-channel transceive array coil. Two volunteers were also examined at 3 T. In each volunteer, the liver and kidney regions were scanned in two separate acquisitions. To homogenize signal excitation, the time-interleaved acquisition of modes (TIAMO) method was used with personalized pairs of B1 shims, based on a 23-s Cartesian fast low angle shot (FLASH) acquisition. Utilizing free-induction decay navigator signals, respiratory-gated images were reconstructed at a spatial resolution of 0.8 × 0.8 × 1.0 mm3. Two experienced radiologists rated the image quality and the impact of B1 inhomogeneity and motion-related artifacts on multipoint scales. The images of all volunteers showcased effective water excitation and were accurately corrected for respiratory motion. The impact of B1 inhomogeneity on image quality was minimal, underscoring the efficacy of the multitransmit TIAMO shim. The high spatial resolution allowed excellent depiction of small structures such as the adrenal glands, the proximal ureter, the diaphragm, and small blood vessels, although some streaking artifacts persisted in liver image data. In direct comparisons with 3 T performed for two volunteers, 7-T acquisitions demonstrated increases in signal-to-noise ratio of 77% and 58%. Overall, this work demonstrates the feasibility of free-breathing MRI in the upper abdomen at submillimeter spatial resolution at a magnetic field strength of 7 T.

3.
Diagnostics (Basel) ; 14(6)2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38534994

ABSTRACT

This study evaluated the relationship between apparent diffusion coefficient (ADC) values in pancreatic ductal adenocarcinoma (PDAC) and tumor grades based on WHO, Adsay, and Kalimuthu classifications, using whole-mount pancreatectomy specimens. If glandular formation plays a key role in the degree of diffusion restriction, diffusion-weighted imaging could facilitate non-invasive grading of PDAC. A freehand region of interest (ROI) was drawn along tumor borders on the preoperative ADC map in each tumor-containing slice. Resection specimens were retrospectively graded according to WHO, Adsay, and Kalimuthu classifications and correlated with overall survival and the 10th percentile of whole-volume ADC values. Findings from 40 patients (23 male, median age 67) showed no correlation between ADC p10 values and WHO differentiation (p = 0.050), Adsay grade (p = 0.955), or Kalimuthu patterns (p = 0.117). There was no association between ADC p10 and overall survival (p = 0.082) and other clinicopathological variables. Survival was significantly lower for poor tumor differentiation (p = 0.046) and non-glandular Kalimuthu patterns (p = 0.016) and there was a trend towards inferior survival for Adsay G3 (p = 0.090) after correction for age, tumor location, and stage. Preoperative ADC measurements for determining PDAC aggressiveness had limited clinical utility, as there was no correlation with histological parameters or overall survival in resectable PDAC.

4.
BMJ Open ; 14(2): e084303, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38413153

ABSTRACT

INTRODUCTION: The INflammation and Small Vessel Disease (INSVD) study aims to investigate whether peripheral inflammation, immune (dys)regulation and blood-brain barrier (BBB) permeability relate to disease progression in cerebral small vessel disease (SVD). This research aims to pinpoint specific components of the immune response in SVD relating to disease progression. This could identify biomarkers of SVD progression, as well as potential therapeutic targets to inform the development and repurposing of drugs to reduce or prevent SVD, cognitive decline and vascular dementia. METHODS AND ANALYSIS: INSVD is a prospective observational multicentre cohort study in individuals with symptomatic SVD. This longitudinal study combines comprehensive immunophenotyping of the peripheral blood immune compartment with advanced neuroimaging markers of SVD and BBB permeability. The main SVD marker of interest is white matter microstructure as determined by diffusion tensor imaging, a valuable marker of disease progression owing to its sensitivity to early alterations to white matter integrity. The research is being conducted in two sites-in the UK (Cambridge) and the Netherlands (Nijmegen)-with each site recruiting 100 participants (total n=200). Participants undergo clinical and cognitive assessments, blood draws, and brain MRI at baseline and 2-year follow-up. ETHICS AND DISSEMINATION: This study received ethical approval from the local ethics boards (UK: East of England-Cambridge Central Research Ethics Committee (REC) ref: 22/EE/00141, Integrated Research Application System (IRAS) ID: 312 747. Netherlands: Medical Research Ethics Committee (MREC) Oost-Nederland, ref: 2022-13623, NL-number: NL80258.091.22). Written informed consent was obtained from all subjects before the study. Any participant-derived benefits resulting from this research, such as new insights into disease mechanisms or possible novel therapies, will be disseminated to study participants, patient groups and members of the public. TRIAL REGISTRATION NUMBER: NCT05746221.


Subject(s)
Cerebral Small Vessel Diseases , Diffusion Tensor Imaging , Humans , Diffusion Tensor Imaging/methods , Blood-Brain Barrier/diagnostic imaging , Longitudinal Studies , Cohort Studies , Prospective Studies , Cerebral Small Vessel Diseases/diagnostic imaging , Magnetic Resonance Imaging/methods , Inflammation , Disease Progression , Observational Studies as Topic , Multicenter Studies as Topic
5.
Invest Radiol ; 59(7): 519-525, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38157433

ABSTRACT

BACKGROUND: Accurate detection of lymph node (LN) metastases in prostate cancer (PCa) is a challenging but crucial step for disease staging. Ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging (MRI) enables distinction between healthy LNs and nodes suspicious for harboring metastases. When combined with MRI at an ultra-high magnetic field, an unprecedented spatial resolution can be exploited to visualize these LNs. PURPOSE: The aim of this study was to explore USPIO-enhanced MRI at 7 T in comparison to 3 T for the detection of small suspicious LNs in the same cohort of patients with PCa. MATERIALS AND METHODS: Twenty PCa patients with high-risk primary or recurrent disease were referred to our hospital for an investigational USPIO-enhanced 3 T MRI examination with ferumoxtran-10. With consent, they underwent a 7 T MRI on the same day. Three-dimensional anatomical and T2*-weighted images of both examinations were evaluated blinded, with an interval, by 2 readers who annotated LNs suspicious for metastases. Number, size, and level of suspicion (LoS) of LNs were paired within patients and compared between field strengths. RESULTS: At 7 T, both readers annotated significantly more LNs compared with 3 T (474 and 284 vs 344 and 162), with 116 suspicious LNs on 7 T (range, 1-34 per patient) and 79 suspicious LNs on 3 T (range, 1-14 per patient) in 17 patients. For suspicious LNs, the median short axis diameter was 2.6 mm on 7 T (1.3-9.5 mm) and 2.8 mm for 3 T (1.7-10.4 mm, P = 0.05), with large overlap in short axis of annotated LNs between LoS groups. At 7 T, significantly more suspicious LNs had a short axis <2.5 mm compared with 3 T (44% vs 27%). Magnetic resonance imaging at 7 T provided better image quality and structure delineation and a higher LoS score for suspicious nodes. CONCLUSIONS: In the same cohort of patients with PCa, more and more small LNs were detected on 7 T USPIO-enhanced MRI compared with 3 T MRI. Suspicious LNs are generally very small, and increased nodal size was not a good indication of suspicion for the presence of metastases. The high spatial resolution of USPIO-enhanced MRI at 7 T improves structure delineation and the visibility of very small suspicious LNs, potentially expanding the in vivo detection limits of pelvic LN metastases in PCa patients.


Subject(s)
Contrast Media , Lymphatic Metastasis , Magnetic Resonance Imaging , Magnetite Nanoparticles , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Magnetic Resonance Imaging/methods , Aged , Lymphatic Metastasis/diagnostic imaging , Middle Aged , Dextrans , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Reproducibility of Results , Sensitivity and Specificity , Ferrosoferric Oxide , Magnetic Iron Oxide Nanoparticles
7.
Magn Reson Med ; 89(5): 1931-1944, 2023 05.
Article in English | MEDLINE | ID: mdl-36594436

ABSTRACT

PURPOSE: To increase the effectiveness of respiratory gating in radial stack-of-stars MRI, particularly when imaging at high spatial resolutions or with multiple echoes. METHODS: Free induction decay (FID) navigators were integrated into a three-dimensional gradient echo radial stack-of-stars pulse sequence. These navigators provided a motion signal with a high temporal resolution, which allowed single-spoke binning (SSB): each spoke at each phase encode step was sorted individually to the corresponding motion state of the respiratory signal. SSB was compared with spoke-angle binning (SAB), in which all phase encode steps of one projection angle were sorted without the use of additional navigator data. To illustrate the benefit of SSB over SAB, images of a motion phantom and of six free-breathing volunteers were reconstructed after motion-gating using either method. Image sharpness was quantitatively compared using image gradient entropies. RESULTS: The proposed method resulted in sharper images of the motion phantom and free-breathing volunteers. Differences in gradient entropy were statistically significant (p = 0.03) in favor of SSB. The increased accuracy of motion-gating led to a decrease of streaking artifacts in motion-gated four-dimensional reconstructions. To consistently estimate respiratory signals from the FID-navigator data, specific types of gradient spoiler waveforms were required. CONCLUSION: SSB allowed high-resolution motion-corrected MR imaging, even when acquiring multiple gradient echo signals or large acquisition matrices, without sacrificing accuracy of motion-gating. SSB thus relieves restrictions on the choice of pulse sequence parameters, enabling the use of motion-gated radial stack-of-stars MRI in a broader domain of clinical applications.


Subject(s)
Artifacts , Image Interpretation, Computer-Assisted , Humans , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Abdomen/diagnostic imaging , Motion , Respiration , Imaging, Three-Dimensional/methods
8.
Eur Stroke J ; 7(3): 331-338, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36082259

ABSTRACT

Background: Neuroimaging markers of cerebral small vessel disease (SVD) are common in older individuals, but the pathophysiological mechanisms causing these lesions remain poorly understood. Although hypertension is a major risk factor for SVD, the direct causal effects of increased blood pressure are unknown. The Hyperintense study is designed to examine cerebrovascular and structural abnormalities, possibly preceding SVD, in young adults with hypertension. These patients undergo a diagnostic work-up that requires patients to temporarily discontinue their antihypertensive agents, often leading to an increase in blood pressure followed by a decrease once effective medication is restarted. This allows examination of the effects of blood pressure increase and decrease on the cerebral small vessels. Methods: Hyperintense is a prospective observational cohort study in 50 hypertensive adults (18-55 years) who will temporarily discontinue antihypertensive medication for diagnostic purposes. MRI and clinical data is collected at four timepoints: before medication withdrawal (baseline), once antihypertensives are largely or completely withdrawn (T = 1), when patients have restarted medication (T = 2) and reached target blood pressure and 1 year later (T = 3). The 3T MRI protocol includes conventional structural sequences and advanced techniques to assess various aspects of microvascular integrity, including blood-brain barrier function using Dynamic Contrast Enhanced MRI, white matter integrity, and microperfusion. Clinical assessments include motor and cognitive examinations and blood sampling. Discussion: The Hyperintense study will improve the understanding of the pathophysiological mechanisms following hypertension that may cause SVD. This knowledge can ultimately help to identify new targets for treatment of SVD, aimed at prevention or limiting disease progression.

9.
Acad Radiol ; 29(12): 1802-1807, 2022 12.
Article in English | MEDLINE | ID: mdl-35256274

ABSTRACT

RATIONALE AND OBJECTIVES: To assess the acquisition time and image quality of simultaneous multislice-accelerated diffusion-weighted imaging (SMS-DWI) versus conventional DWI (C-DWI) of the rectum. MATERIALS AND METHODS: In patients scheduled for a magnetic resonance imaging of the rectum, both SMS-DWI and C-DWI were performed on a 3T whole body magnetic resonance scanner. Image quality of the DWI sequences was reviewed by two independent radiologists who were blinded to the method of imaging using a five-point Likert scale: (score ranging from 1 (non-diagnostic) to 5 (excellent). The mean scores of SMS-DWI versus C-DWI were compared for the individual readers using a nonparametric test (Wilcoxon signed ranks). RESULTS: The SMS-DWI protocol acquisition time was 4:08 min vs. 7:24 min per patient, which led to a reduction of 44.1% for the C-DWI protocol, both excluding time for sequence specific adjustments (shimming). No statistical differences between the conventional-, and SMS- diffusion weighted images were seen for both readers. Mean overall image quality of the SMS-DWI TRACE images was 3.5 (SD: 1.3) and 3.3 (SD: 1.0) for reader 1 and reader 2, respectively. Mean overall image quality of the C-DWI TRACE images was 3.4 (SD: 1.3) and 3.2 (SD: 1.1) for reader 1 and reader 2, respectively. CONCLUSION: Optimized SMS-DWI compared to C-DWI in imaging of the rectum showed similar image quality while a significant acquisition time reduction was achieved.


Subject(s)
Diffusion Magnetic Resonance Imaging , Rectum , Humans , Rectum/diagnostic imaging , Reproducibility of Results , Diffusion Magnetic Resonance Imaging/methods , Pelvis , Echo-Planar Imaging/methods
10.
Neuroradiology ; 64(6): 1145-1156, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34719725

ABSTRACT

INTRODUCTION: In order to augment the certainty of the radiological interpretation of "possible microbleeds" after traumatic brain injury (TBI), we assessed their longitudinal evolution on 3-T SWI in patients with moderate/severe TBI. METHODS: Standardized 3-T SWI and T1-weighted imaging were obtained 3 and 26 weeks after TBI in 31 patients. Their microbleeds were computer-aided detected and classified by a neuroradiologist as no, possible, or definite at baseline and follow-up, separately (single-scan evaluation). Thereafter, the classifications were re-evaluated after comparison between the time-points (post-comparison evaluation). We selected the possible microbleeds at baseline at single-scan evaluation and recorded their post-comparison classification at follow-up. RESULTS: Of the 1038 microbleeds at baseline, 173 were possible microbleeds. Of these, 53.8% corresponded to no microbleed at follow-up. At follow-up, 30.6% were possible and 15.6% were definite. Of the 120 differences between baseline and follow-up, 10% showed evidence of a pathophysiological change over time. Proximity to extra-axial injury and proximity to definite microbleeds were independently predictive of becoming a definite microbleed at follow-up. The reclassification level differed between anatomical locations. CONCLUSIONS: Our findings support disregarding possible microbleeds in the absence of clinical consequences. In selected cases, however, a follow-up SWI-scan could be considered to exclude evolution into a definite microbleed.


Subject(s)
Brain Injuries, Traumatic , Magnetic Resonance Imaging , Brain Injuries, Traumatic/complications , Brain Injuries, Traumatic/diagnostic imaging , Cerebral Hemorrhage/diagnostic imaging , Humans , Longitudinal Studies , Magnetic Resonance Imaging/methods , Radiography
11.
Sci Rep ; 11(1): 2085, 2021 01 22.
Article in English | MEDLINE | ID: mdl-33483545

ABSTRACT

T2-weighted (T2W) MRI provides high spatial resolution and tissue-specific contrast, but it is predominantly used for qualitative evaluation of prostate anatomy and anomalies. This retrospective multicenter study evaluated the potential of T2W image-derived textural features for quantitative assessment of peripheral zone prostate cancer (PCa) aggressiveness. A standardized preoperative multiparametric MRI was performed on 87 PCa patients across 6 institutions. T2W intensity and apparent diffusion coefficient (ADC) histogram, and T2W textural features were computed from tumor volumes annotated based on whole-mount histology. Spearman correlations were used to evaluate association between textural features and PCa grade groups (i.e. 1-5). Feature utility in differentiating and classifying low-(grade group 1) vs. intermediate/high-(grade group ≥ 2) aggressive cancers was evaluated using Mann-Whitney U-tests, and a support vector machine classifier employing "hold-one-institution-out" cross-validation scheme, respectively. Textural features indicating image homogeneity and disorder/complexity correlated significantly (p < 0.05) with PCa grade groups. In the intermediate/high-aggressive cancers, textural homogeneity and disorder/complexity were significantly lower and higher, respectively, compared to the low-aggressive cancers. The mean classification accuracy across the centers was highest for the combined ADC and T2W intensity-textural features (84%) compared to ADC histogram (75%), T2W histogram (72%), T2W textural (72%) features alone or T2W histogram and texture (77%), T2W and ADC histogram (79%) combined. Texture analysis of T2W images provides quantitative information or features that are associated with peripheral zone PCa aggressiveness and can augment their classification.


Subject(s)
Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Aged , Humans , Male , Middle Aged , Prostatic Neoplasms/pathology , Reproducibility of Results , Retrospective Studies , Support Vector Machine
12.
J Physiol ; 599(5): 1533-1550, 2021 03.
Article in English | MEDLINE | ID: mdl-33369737

ABSTRACT

KEY POINTS: The post-exercise recovery of phosphocreatine, a measure of the oxidative capacity of muscles, as assessed by 31 P MR spectroscopy, shows a striking increase from distal to proximal along the human tibialis anterior muscle. To investigate why this muscle exhibits a greater oxidative capacity proximally, we tested whether the spatial variation in phosphocreatine recovery rate is related to oxygen supply, muscle fibre type or type of exercise. We revealed that oxygen supply also increases from distal to proximal along the tibialis anterior, and that it strongly correlated with phosphocreatine recovery. Carnosine level, a surrogate measure for muscle fibre type was not different between proximal and distal, and type of exercise did not affect the gradient in phosphocreatine recovery rate. Taken together, the findings of this study suggest that the post-exercise spatial gradients in oxygen supply and phosphocreatine recovery are driven by a higher intrinsic mitochondrial oxidative capacity proximally. ABSTRACT: Phosphorus magnetic resonance spectroscopy (31 P MRS) of human tibialis anterior (TA) revealed a strong proximo-distal gradient in the post-exercise phosphocreatine (PCr) recovery rate constant (kPCr ), a measure of muscle oxidative capacity. The aim of this study was to investigate whether this kPCr gradient is related to O2 supply, resting phosphorylation potential, muscle fibre type, or type of exercise. Fifteen male volunteers performed continuous isometric ankle dorsiflexion at 30% maximum force until exhaustion. At multiple locations along the TA, we measured the oxidative PCr resynthesis rate (VPCr = kPCr × PCr depletion) by 31 P MRS, the oxyhaemoglobin recovery rate constant (kO2Hb ) by near infrared spectroscopy, and muscle perfusion with MR intravoxel incoherent motion imaging. The kO2Hb , kPCr , VPCr and muscle perfusion depended on measurement location (P < 0.001, P < 0.001, P = 0.032 and P = 0.003, respectively), all being greater proximally. The kO2Hb and muscle perfusion correlated with kPCr (r = 0.956 and r = 0.852, respectively) and VPCr (r = 0.932 and r = 0.985, respectively), the latter reflecting metabolic O2 consumption. Resting phosphorylation potential (PCr/inorganic phosphate) was also higher proximally (P < 0.001). The surrogate for fibre type, carnosine content measured by 1 H MRS, did not differ between distal and proximal TA (P = 0.884). Performing intermittent exercise to avoid exercise ischaemia, still led to larger kPCr proximally than distally (P = 0.013). In conclusion, the spatial kPCr gradient is strongly associated with the spatial variation in O2 supply. It cannot be explained by exercise-induced ischaemia nor by fibre type. Our findings suggest it is driven by a higher proximal intrinsic mitochondrial oxidative capacity, apparently to support contractile performance of the TA.


Subject(s)
Exercise , Muscle, Skeletal , Adenosine Triphosphate , Humans , Male , Muscle Contraction , Phosphocreatine
13.
PLoS One ; 15(7): e0236884, 2020.
Article in English | MEDLINE | ID: mdl-32735614

ABSTRACT

OBJECTIVE: The definition of an in vivo nodal anatomical baseline is crucial for validation of representative lymph node dissections and accompanying pathology reports of pelvic cancers, as well as for assessing a potential therapeutic effect of extended lymph node dissections. Therefore the number, size and distribution of lymph nodes in the pelvis were assessed with high-resolution, large field-of-view, 7 Tesla (T) magnetic resonance imaging (MRI) with frequency-selective excitation. MATERIALS AND METHODS: We used 7 T MRI for homogeneous pelvic imaging in 11 young healthy volunteers. Frequency-selective imaging of water and lipids was performed to detect nodal structures in the pelvis. Number and size of detected nodes was measured and size distribution per region was assessed. An average volunteer-normalized nodal size distribution was determined. RESULTS: In total, 564 lymph nodes were detected in six pelvic regions. Mean number was 51.3 with a wide range of 19-91 lymph nodes per volunteer. Mean diameter was 2.3 mm with a range of 1 to 7 mm. 69% Was 2 mm or smaller. The overall size distribution was very similar to the average volunteer-normalized nodal size distribution. CONCLUSIONS: The amount of in vivo visible lymph nodes varies largely between subjects, whereas the normalized size distribution of nodes does not. The presence of many small lymph nodes (≤2mm) renders representative or complete removal of pelvic lymph nodes to be very difficult. 7T MRI may shift the in vivo detection limits of lymph node metastases in the future.


Subject(s)
Lymph Nodes , Magnetic Resonance Imaging/methods , Adult , Female , Humans , Lymph Nodes/anatomy & histology , Lymph Nodes/diagnostic imaging , Magnetic Fields , Male , Middle Aged , Pelvis/diagnostic imaging
14.
Head Neck ; 42(8): 2039-2049, 2020 08.
Article in English | MEDLINE | ID: mdl-32119170

ABSTRACT

BACKGROUND: Current intraoperative methods of visual inspection and tissue palpation by the surgeon, and frozen section analysis cannot reliably prevent inadequate surgical margins in patients treated for oral squamous-cell carcinoma (OSCC). This study assessed feasibility of MRI for the assessment of surgical resection margins in fresh OSCC specimens. METHODS: Ten consecutive tongue specimens containing OSCC were scanned using 3 T clinical whole-body MRI. Two radiologists independently annotated OSCC location and minimal tumor-free margins. Whole-mount histology was the reference standard. RESULTS: The positive predictive values (PPV) and negative predictive values (NPV) for OSCC localization were 96% and 75%, and 87% and 79% for reader 1 and 2, respectively. The PPV and NPV for identification of margins <5 mm were 38% and 91%, and 5% and 87% for reader 1 and 2, respectively. CONCLUSIONS: MRI accurately localized OSCC with high inter-reader agreement in fresh OSCC specimens, but it seemed not yet feasible to accurately assess the surgical margin status.


Subject(s)
Carcinoma, Squamous Cell , Head and Neck Neoplasms , Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/surgery , Humans , Magnetic Resonance Imaging , Margins of Excision , Tongue
15.
Eur Radiol ; 29(12): 6529-6538, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31201525

ABSTRACT

PURPOSE: To evaluate the technical feasibility of high-resolution USPIO-enhanced magnetic resonance imaging of pelvic lymph nodes (LNs) at ultrahigh magnetic field strength. MATERIALS AND METHODS: The ethics review board approved this study and written informed consent was obtained from all patients. Three patients with rectal cancer and three selected patients with (recurrent) prostate cancer were examined at 7-T 24-36 h after intravenous ferumoxtran-10 administration; rectal cancer patients also received a 3-T MRI. Pelvic LN imaging was performed using the TIAMO technique in combination with water-selective multi-GRE imaging and lipid-selective GRE imaging with a spatial resolution of 0.66 × 0.66 × 0.66mm3. T2*-weighted images of the water-selective imaging were computed from the multi-GRE images at TE = 0, 8, and 14 ms and used for the assessment of USPIO uptake. RESULTS: High-resolution 7-T MR gradient-echo imaging was obtained robustly in all patients without suffering from RF-related signal voids. USPIO signal decay in LNs was visualized using computed TE imaging at TE = 8 ms and an R2* map derived from water-selective imaging. Anatomically, LNs were identified on a combined reading of computed TE = 0 ms images from water-selective scans and images from lipid-selective scans. A range of 3-48 LNs without USPIO signal decay was found per patient. These LNs showed high signal intensity on computed TE = 8 and 14 ms imaging and low R2* (corresponding to high T2*) values on the R2* map. CONCLUSION: USPIO-enhanced MRI of the pelvis at 7-T is technically feasible and offers opportunities for detecting USPIO uptake in normal-sized LNs, due to its high intrinsic signal-to-noise ratio and spatial resolution. KEY POINTS: • USPIO-enhanced MRI at 7-T can indicate USPIO uptake in lymph nodes based on computed TE images. • Our method promises a high spatial resolution for pelvic lymph node imaging.


Subject(s)
Contrast Media , Dextrans , Image Enhancement/methods , Lymph Nodes/diagnostic imaging , Lymphatic Metastasis/diagnostic imaging , Magnetic Resonance Imaging/methods , Magnetite Nanoparticles , Aged , Feasibility Studies , Female , Humans , Lymph Nodes/pathology , Lymphatic Metastasis/pathology , Male , Middle Aged , Pelvis/pathology , Reproducibility of Results
16.
Invest Radiol ; 54(7): 437-447, 2019 07.
Article in English | MEDLINE | ID: mdl-30946180

ABSTRACT

OBJECTIVES: The aims of this study were to assess the discriminative performance of quantitative multiparametric magnetic resonance imaging (mpMRI) between prostate cancer and noncancer tissues and between tumor grade groups (GGs) in a multicenter, single-vendor study, and to investigate to what extent site-specific differences affect variations in mpMRI parameters. MATERIALS AND METHODS: Fifty patients with biopsy-proven prostate cancer from 5 institutions underwent a standardized preoperative mpMRI protocol. Based on the evaluation of whole-mount histopathology sections, regions of interest were placed on axial T2-weighed MRI scans in cancer and noncancer peripheral zone (PZ) and transition zone (TZ) tissue. Regions of interest were transferred to functional parameter maps, and quantitative parameters were extracted. Across-center variations in noncancer tissues, differences between tissues, and the relation to cancer grade groups were assessed using linear mixed-effects models and receiver operating characteristic analyses. RESULTS: Variations in quantitative parameters were low across institutes (mean [maximum] proportion of total variance in PZ and TZ, 4% [14%] and 8% [46%], respectively). Cancer and noncancer tissues were best separated using the diffusion-weighted imaging-derived apparent diffusion coefficient, both in PZ and TZ (mean [95% confidence interval] areas under the receiver operating characteristic curve [AUCs]; 0.93 [0.89-0.96] and 0.86 [0.75-0.94]), followed by MR spectroscopic imaging and dynamic contrast-enhanced-derived parameters. Parameters from all imaging methods correlated significantly with tumor grade group in PZ tumors. In discriminating GG1 PZ tumors from higher GGs, the highest AUC was obtained with apparent diffusion coefficient (0.74 [0.57-0.90], P < 0.001). The best separation of GG1-2 from GG3-5 PZ tumors was with a logistic regression model of a combination of functional parameters (mean AUC, 0.89 [0.78-0.98]). CONCLUSIONS: Standardized data acquisition and postprocessing protocols in prostate mpMRI at 3 T produce equivalent quantitative results across patients from multiple institutions and achieve similar discrimination between cancer and noncancer tissues and cancer grade groups as in previously reported single-center studies.


Subject(s)
Multiparametric Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Aged , Area Under Curve , Humans , Logistic Models , Male , Middle Aged , Neoplasm Invasiveness , Prospective Studies , Prostate/diagnostic imaging , Prostate/pathology , ROC Curve , Reproducibility of Results
17.
Brain Struct Funct ; 223(6): 2721-2731, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29572626

ABSTRACT

Phosphorus magnetic resonance spectroscopy (31P MRS) has been employed before to assess phosphocreatine (PCr) and other high-energy phosphates in the visual cortex during visual stimulation with inconsistent results. We performed functional 31P MRS imaging in the visual cortex and control regions during a visual stimulation paradigm at an unprecedented sensitivity, exploiting a dedicated RF coil design at a 7 T MR system. Visual stimulation in a 3 min 24 s on-off paradigm in eight young healthy adults generated a clear BOLD effect with traditional 1H functional MRI in the visual cortex (average z score 9.9 ± 0.2). However, no significant event-related changes in any of the 31P metabolite concentrations, linewidths (7.9 ± 1.8 vs 7.8 ± 1.9 Hz) or tissue pH (7.07 ± 0.13 vs 7.06 ± 0.07) were detectable. Overall, our study of 31P MRSI in 15 cm3 voxels had a detection threshold for changes in PCr, Pi and γ-ATP between stimulation and rest of 5, 17 and 10%, respectively. In individual subjects, the mean coefficients of variance for PCr and Pi levels of control voxels were 6 ± 3 and 19 ± 8% (three time point average of 3 min 24 s). Altogether this indicates that energy supply for neuronal activation at this temporal resolution does not drain global PCr resources.


Subject(s)
Energy Metabolism/physiology , Phosphates/metabolism , Photic Stimulation/methods , Visual Cortex/metabolism , Visual Cortex/physiology , Adult , Brain Mapping , Female , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Male , Oxygen/blood , Rest , Visual Cortex/diagnostic imaging , Young Adult
18.
Invest Radiol ; 52(10): 640-646, 2017 10.
Article in English | MEDLINE | ID: mdl-28632688

ABSTRACT

OBJECTIVES: Inclusion of 3-dimensional H magnetic resonance spectroscopic imaging (3D-H-MRSI) in routine multiparametric MRI of the prostate requires good quality spectra and easy interpretable metabolite maps of the whole organ obtained without endorectal coil in clinically feasible acquisition times. We evaluated if a semi-LASER pulse sequence with gradient offset independent adiabaticity refocusing pulses (GOIA-sLASER) for volume selection can meet these requirements. MATERIALS AND METHODS: Thirteen patients with suspicion of prostate cancer and 1 patient known to have prostate cancer were examined at 3 T with a multichannel body-receive coil. A 3D-H-MRSI sequence with GOIA-sLASER volume selection (echo time, 88 milliseconds) was added to a routine clinical multiparametric MRI examination of these patients. Repetition times from 630 to 1000 milliseconds and effective voxel sizes of approximately 0.9 and 0.6 cm were tested. Spectral components were quantified by LCModel software for quality assessment and to construct choline and citrate maps. RESULTS: Three-dimensional MRSI of the prostate was successfully performed in all patients in measurement times of 5 to 10 minutes. Analysis of the multiparametric MRI examination or of biopsies did not reveal malignant tissue in the prostate of the 13 patients. In 1404 evaluated voxels acquired from 13 patients, the citrate resonance could be fitted with a high reliability (Cramér-Rao lower bound <30%), 100% for 7 × 7 × 7-mm voxels and 96 ± 7 in 6 × 6 × 6-mm voxels. The percentage of 7 × 7 × 7-mm voxels in which the choline signal was fitted with Cramér-Rao lower bound of less than 30% was approximately 50% at a TR of 630 milliseconds and increased to more than 80% for TRs of 800 milliseconds and above. In the patient with prostate cancer, choline was detectable throughout the prostate in spectra recorded at a TR of 700 milliseconds. The homogeneous B1 field over the prostate of the receive coil enabled the generation of whole organ metabolite maps, revealing choline and citrate variations between areas with normal prostate tissue, seminal vesicles, proliferative benign prostatic hyperplasia, and tumor. CONCLUSIONS: The good signal-to-noise ratio and low chemical shift artifacts of GOIA-sLASER at an echo time of 88 milliseconds enable acquisition of high-quality 3D-H-MRSI of the prostate without endorectal coil in less than 10 minutes. This facilitates reconstruction of easy interpretable, quantitative metabolite maps for routine clinical applications of prostate MRSI.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Spectroscopy/methods , Prostatic Neoplasms/diagnostic imaging , Aged , Artifacts , Humans , Male , Middle Aged , Prostate/diagnostic imaging , Prostatic Neoplasms/pathology , Reproducibility of Results , Signal-To-Noise Ratio
19.
Invest Radiol ; 52(10): 574-582, 2017 10.
Article in English | MEDLINE | ID: mdl-28463932

ABSTRACT

OBJECTIVE: Ultrafast dynamic contrast-enhanced magnetic resonance imaging of the breast enables assessment of the contrast inflow dynamics while providing images with diagnostic spatial resolution. However, the slice thickness of common ultrafast techniques still prevents multiplanar reconstruction. In addition, some temporal blurring of the enhancement characteristics occurs in case view-sharing is used. We evaluate a prototype compressed-sensing volume-interpolated breath-hold examination (CS-VIBE) sequence for ultrafast breast MRI that improves through plane spatial resolution and avoids temporal blurring while maintaining an ultrafast temporal resolution (less than 5 seconds per volume). Image quality (IQ) of the new sequence is compared with an ultrafast view-sharing sequence (time-resolved angiography with interleaved stochastic trajectories [TWIST]), and assessment of lesion morphology is compared with a regular T1-weighted 3D Dixon sequence (VIBE-DIXON) with an acquisition time of 91 seconds. MATERIALS AND METHODS: From April 2016 to October 2016, 30 women were scanned with the CS-VIBE sequence, replacing the routine ultrafast TWIST sequence in a hybrid breast MRI protocol. The need for informed consent was waived. All MRI scans were performed on a 3T MAGNETOM Skyra system (Siemens Healthcare, Erlangen, Germany) using a 16-channel bilateral breast coil. Two reader studies were conducted involving 5 readers. In the first study, overall IQ of CS-VIBE and TWIST in the axial plane was independently rated for 23 women for whom prior MRI examinations with TWIST were available. In addition, the presence of several types of artifacts was rated on a 5-point scale. The second study was conducted in women (n = 16) with lesions. In total, characteristics of 31 lesions (5 malignant and 26 benign) were described independently for CS-VIBE and VIBE-DIXON, according to the BI-RADS MRI-lexicon. In addition, a lesion conspicuity score was given. RESULTS: Using CS-VIBE, a much higher through-plane spatial resolution was achieved in the same acquisition time as with TWIST, without affecting in-plane IQ (P = 0.260). Time-resolved angiography with interleaved stochastic trajectories showed slightly more motion artifacts and infolding and ghosting artifacts compared with CS-VIBE, whereas CS-VIBE showed more breathing and pulsation artifacts. For morphologic assessment, intrareader agreement between CS-VIBE and the more time-consuming VIBE-DIXON was slight to almost perfect, and generally higher than interreader agreement. Mean sensitivity (84.0% and 92.0% for CS-VIBE and VIBE-DIXON, P = 0.500) and specificity (60.0% and 55.4% for CS-VIBE and VIBE-DIXON, P = 0.327) were comparable for both sequences. CONCLUSIONS: Compressed-sensing volume-interpolated breath-hold examination allows an increase of the through-plane spatial resolution of ultrafast dynamic contrast-enhanced magnetic resonance imaging compared with TWIST at a comparable in-plane IQ. Morphological assessment of lesions using CS-VIBE is comparable to VIBE-DIXON, which takes 18 times longer. Consequently, CS-VIBE enables 3D evaluation of breast lesions in ultrafast breast MRI.


Subject(s)
Breast Neoplasms/diagnostic imaging , Contrast Media , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Aged , Artifacts , Breast/diagnostic imaging , Breath Holding , Female , Humans , Middle Aged , Motion , Reproducibility of Results , Sensitivity and Specificity
20.
Magn Reson Med ; 78(3): 1020-1028, 2017 09.
Article in English | MEDLINE | ID: mdl-27714842

ABSTRACT

PURPOSE: Pelvic lymph node (PLN) metastases are often smaller than 5 mm and difficult to detect. This work presents a method to perform PLN imaging with ultrahigh-field MRI, using spectrally selective excitation to acquire water and lipid-selective imaging at high spatial resolution. METHODS: A 3D water-selective multigradient echo (mGRE) sequence and lipid-selective gradient echo (GRE) sequence were tested in six healthy volunteers on a 7 Tesla (T) MRI system, using time interleaved acquisition of modes (TIAMO) to improve image homogeneity. The size distribution of the first 10 iliac PLNs detected in each volunteer was determined, and the contrast-to-noise ratio (CNR) of these lymph nodes (LNs) was compared with the individual mGRE images, sum-of-squares echo addition, and computed T2*-weighted images derived from the T2* fits. RESULTS: LN imaging was acquired robustly at ultrahigh field with high resolution and homogeneous lipid or water-selective contrast. PLNs down to 1.5-mm short axis were detected with mean ± standard error of the mean (SEM) short and long axes of 2.2 ± 0.1 and 3.7 ± 0.2 mm, respectively. Computed T2*-weighted imaging allowed flexibility in T2* contrast while featuring a CNR up to 90% of the sum-of-squares echo addition. CONCLUSION: Ultrahigh-field MRI in combination with TIAMO and frequency-selective excitation enables high-resolution, large field-of-view MRI of the lower abdomen, and may ultimately be suitable for detecting small PLN metastases. Magn Reson Med 78:1020-1028, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Subject(s)
Imaging, Three-Dimensional/methods , Lymph Nodes/diagnostic imaging , Magnetic Resonance Imaging/methods , Pelvis/diagnostic imaging , Abdomen/diagnostic imaging , Adult , Algorithms , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...