Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Gastroenterol Hepatol ; 13(7): 1242-1248.e1, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25592662

ABSTRACT

BACKGROUND & AIMS: Penetration of the esophageal epithelium by food antigens is an early event in the pathogenesis of eosinophilic esophagitis (EoE), but the precise relationship among eosinophilia, dilated intercellular spaces (DIS), and decreased barrier function is unclear. We investigated the correlation between site-specific mucosal impedance (MI) measurements of ion flux and esophageal histology, and whether MI measurements can be used to distinguish between patients with active and inactive EoE. METHODS: MI was measured (in Ω) in 10 patients with active EoE (>15 eosinophils [eos]/high-power field [HPF]) and in 10 with inactive EoE (<15 eos/HPF, as a result of treatment), and mucosal biopsy specimens were collected from 4 esophageal sites (2, 5, 10, and 15 cm above the Z-line). MI also was measured in 10 individuals without esophageal symptoms (controls). MI measurements, eos/HPF, and DIS grade were compared among patients with EoE and controls. RESULTS: The esophageal MI values were significantly lower in patients with active EoE (1909 Ω) compared with inactive EoE (4349 Ω) or controls (5530 Ω) (P < .001). Biopsy specimens from 4 patients with active EoE contained fewer than 15 eos/HPF and lower-grade DIS than in patients with active disease. There were significant inverse correlations between MI and eos/HPF (rs = -.584), as well as between MI and DIS (rs = -.531; P < .001). The MI cut-off value of 2300 Ω identified patients with active EoE with 90% sensitivity and 91% specificity, and high-grade DIS with 89% sensitivity and 82% specificity. CONCLUSIONS: In patients with EoE, eosinophilia and DIS correlate with MI measurements of ion flux. Endoscopic MI measurement in the esophagus is safe and easy to perform, and can be used to assess activity of diseases such as EoE.


Subject(s)
Electric Impedance , Eosinophilia/pathology , Eosinophilic Esophagitis/pathology , Extracellular Space , Mucous Membrane/pathology , Adolescent , Adult , Animals , Endoscopy/methods , Eosinophilic Esophagitis/diagnosis , Female , Histocytochemistry , Humans , Male , Middle Aged , Young Adult
2.
Gastroenterology ; 148(2): 334-43, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25448923

ABSTRACT

BACKGROUND & AIMS: Current diagnostic tests for gastroesophageal reflux disease (GERD) are suboptimal and do not accurately and reliably measure chronicity of reflux. A minimally invasive device has been developed to assess esophageal mucosal impedance (MI) as a marker of chronic reflux. We performed a prospective longitudinal study to investigate MI patterns in patients with GERD and common nonreflux conditions, to assess MI patterns before and after treatment with proton pump inhibitors and to compare the performance of MI and wireless pH tests. METHODS: We evaluated MI in 61 patients with erosive esophagitis, 81 with nonerosive but pH-abnormal GERD, 93 without GERD, 18 with achalasia, and 15 with eosinophilic esophagitis. MI was measured at the site of esophagitis and at 2, 5, and 10 cm above the squamocolumnar junction in all participants. MI was measured before and after acid suppressive therapy, and findings were compared with those from wireless pH monitoring. RESULTS: MI values were significantly lower in patients with GERD (erosive esophagitis or nonerosive but pH-abnormal GERD) or eosinophilic esophagitis than in patients without GERD or patients with achalasia (P < .001). The pattern of MI in patients with GERD differed from that in patients without GERD or patients with eosinophilic esophagitis; patients with GERD had low MI closer to the squamocolumnar junction, and values increased axially along the esophagus. These patterns normalized with acid suppressive therapy. MI patterns identified patients with esophagitis with higher levels of specificity (95%) and positive predictive values (96%) than wireless pH monitoring (64% and 40%, respectively). CONCLUSIONS: Based on a prospective study using a prototype device, measurements of MI detect GERD with higher levels of specificity and positive predictive values than wireless pH monitoring. Clinical Trials.gov, Number: NCT01556919.


Subject(s)
Gastroesophageal Reflux/diagnosis , Adult , Electric Impedance , Female , Humans , Hydrogen-Ion Concentration , Longitudinal Studies , Male , Middle Aged , Mucous Membrane/metabolism , Prospective Studies
3.
Gut ; 64(3): 373-80, 2015 Mar.
Article in English | MEDLINE | ID: mdl-24812000

ABSTRACT

OBJECTIVE: Current diagnostic methods for gastro-oesophageal reflux disease (GORD) have moderate sensitivity/specificity and can be invasive and expensive. Pepsin detection in saliva has been proposed as an 'office-based' method for GORD diagnosis. The aims of this study were to establish normal values of salivary pepsin in healthy asymptomatic subjects and to determine its value to discriminate patients with reflux-related symptoms (GORD, hypersensitive oesophagus (HO)) from functional heartburn (FH). DESIGN: 100 asymptomatic controls and 111 patients with heartburn underwent MII-pH monitoring and simultaneous salivary pepsin determination on waking, after lunch and dinner. Cut-off value for pepsin positivity was 16 ng/mL. Patients were divided into GORD (increased acid exposure time (AET), n=58); HO (normal AET and + Symptom Association Probability (SAP), n=26) and FH (normal AET and-SAP, n=27). RESULTS: 1/3 of asymptomatic subjects had pepsin in saliva at low concentration (0(0-59)ng/mL). Patients with GORD and HO had higher prevalence and pepsin concentration than controls (HO, 237(52-311)ng/mL and GORD, 121(29-252)ng/mL)(p<0.05). Patients with FH had low prevalence and concentration of pepsin in saliva (0(0-40) ng/mL). A positive test had 78.6% sensitivity and 64.9% specificity for diagnosis of GORD+HO (likelihood ratio: 2.23). However, one positive sample with >210 ng/mL pepsin suggested presence of GORD+HO with 98.2% specificity (likelihood ratio: 25.1). Only 18/84 (21.4%) of GORD+HO patients had 3 negative samples. CONCLUSION: In patients with symptoms suggestive of GORD, salivary pepsin testing may complement questionnaires to assist office-based diagnosis. This may lessen the use of unnecessary antireflux therapy and the need for further invasive and expensive diagnostic methods.


Subject(s)
Gastroesophageal Reflux/diagnosis , Pepsin A/analysis , Saliva/chemistry , Adult , Case-Control Studies , Eating , Female , Heartburn/diagnosis , Humans , Male , Middle Aged , Reference Values , Sensitivity and Specificity , Surveys and Questionnaires , Young Adult
4.
Clin Gastroenterol Hepatol ; 10(10): 1110-6, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22642956

ABSTRACT

BACKGROUND & AIMS: Diagnostic tests for gastroesophageal reflux disease (GERD) are constrained because measurements are made at a single time point, so the long-term effects on the mucosa cannot be determined. We developed a minimally invasive system to assess changes in esophageal mucosal impedance (MI), a marker of reflux. We measured the extent of changes in MI along the esophagus and show that the device to assess MI can be used to diagnose patients with GERD. METHODS: A single-channel MI catheter composed of a unique sensor array was designed to easily traverse the working channel of an upper endoscope. We performed a prospective longitudinal study of patients with erosive esophagitis (n = 19), nonerosive but pH-positive GERD (n = 23), and those without GERD (n = 27). MI was measured at the site of esophagitis as well as 2, 5, and 10 cm above the squamocolumnar junction. The MI values were compared among groups, at different levels along the esophageal axis. RESULTS: Median MI values were significantly lower at the site of erosive mucosa (811 Ω; range, 621-1272 Ω) than other nonerosive regions (3723 Ω; range, 2421-4671 Ω; P = .001), and were significantly lower at 2 cm above the squamocolumnar junction in patients with GERD (2096 Ω; range, 1415-2808 Ω), compared with those without GERD (3607 Ω; range, 1973-4238 Ω; P = .008). There was a significant and graded increase in MI along the axis of the distal to proximal esophagus in patients with GERD that was not observed in individuals without reflux (P = .004). CONCLUSIONS: Measurements of MI along the esophagus can be used to identify patients with GERD. ClinicalTrials.gov, number NCT01194323.


Subject(s)
Electric Impedance , Endoscopy, Gastrointestinal/methods , Esophagus/physiopathology , Gastroesophageal Reflux/diagnosis , Mucous Membrane/physiopathology , Adult , Female , Humans , Longitudinal Studies , Male , Middle Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...