Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
Add more filters










Publication year range
1.
Cell Mol Life Sci ; 69(3): 389-404, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22015612

ABSTRACT

Nanoparticles (NPs) comprised of nanoengineered complexes are providing new opportunities for enabling targeted delivery of a range of therapeutics and combinations. A range of functionalities can be included within a nanoparticle complex, including surface chemistry that allows attachment of cell-specific ligands for targeted delivery, surface coatings to increase circulation times for enhanced bioavailability, specific materials on the surface or in the nanoparticle core that enable storage of a therapeutic cargo until the target site is reached, and materials sensitive to local or remote actuation cues that allow controlled delivery of therapeutics to the target cells. However, despite the potential benefits of NPs as smart drug delivery and diagnostic systems, much research is still required to evaluate potential toxicity issues related to the chemical properties of NP materials, as well as their size and shape. The need to validate each NP for safety and efficacy with each therapeutic compound or combination of therapeutics is an enormous challenge, which forces industry to focus mainly on those nanoparticle materials where data on safety and efficacy already exists, i.e., predominantly polymer NPs. However, the enhanced functionality affordable by inclusion of metallic materials as part of nanoengineered particles provides a wealth of new opportunity for innovation and new, more effective, and safer therapeutics for applications such as cancer and cardiovascular diseases, which require selective targeting of the therapeutic to maximize effectiveness while avoiding adverse effects on non-target tissues.


Subject(s)
Drug Carriers/chemistry , Nanoparticles/chemistry , Antineoplastic Agents/administration & dosage , Antineoplastic Agents/chemistry , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/therapy , Contrast Media , Drug-Eluting Stents , Humans , Nanoparticles/therapeutic use , Neoplasms/drug therapy , Polymers/chemistry
2.
J Biomed Mater Res A ; 100(1): 230-5, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22042638

ABSTRACT

Herein we report on a preparation and performance of stable, hydrophilic and biocompatible polymeric material suitable for functionalization of disposable substrates used in biosensors. This new material features COOH surface groups cross-linked with ethylene glycol molecules and was prepared in situ on disposable, plastic substrate by high-throughput and environmentally friendly technique called plasma-enhanced chemical vapor deposition (PECVD). The film is grafted to the plasma activated plastic by sequential deposition of tetraethylorthosilicate, forming a bonding layer, and mixed vapors of acrylic acid and diethyleneglycol dimethylether (AA/PEG) that provide the desired functional groups forming a sensing, contact layer. A superior performance of the AA/PEG coating as suitable material for substrates in biomedical devices was demonstrated in a model fluorescence linked immunosorbent assay. The results were compared with other commonly used surface materials prepared by wet chemistry methods. The unique characteristic of the AA/PEG film is that the immunoassay can be executed without the need for a blocking step, typically using albumins, without negative consequences on the bioassay results. In fact, the superior quality of the materials modified with AA/PEG film was highlighted by improving the sensitivity of an immunoassay by two orders of magnitude when compared with substrates prepared by standard surface chemistry methods.


Subject(s)
Immunoassay/methods , Materials Testing/methods , Plasma Gases/chemistry , Polyethylene Glycols/chemistry , Acrylates/chemistry , Antibodies/immunology , Fluorescence , Humans , Immunosorbents , Sensitivity and Specificity , Surface Properties , Water
3.
Analyst ; 136(21): 4431-6, 2011 Nov 07.
Article in English | MEDLINE | ID: mdl-21904732

ABSTRACT

Antibody immobilization strategies (random, covalent, orientated and combinations of each) were examined to determine their performance in a surface plasmon resonance-based immunoassay using human fetuin A (HFA) as the model antigen system. The random antibody immobilization strategy selected was based on passive adsorption of anti-HFA antibody on 3-aminopropyltriethoxysilane (APTES)-functionalized gold (Au) chips. The covalent strategy employed covalent crosslinking of anti-HFA antibody on APTES-functionalized chips using 1-ethyl-3-[3-dimethylaminopropyl]carbodiimide (EDC) and sulfo-N-hydroxysuccinimide (SNHS). The orientation strategy used passive adsorption of protein A (PrA) on Au chips, with subsequent binding of the anti-HFA antibody in an orientated fashion via its fragment crystallisable (Fc) region. In the covalent-orientated strategy, PrA was first bound covalently, to the surface, which in turn, then binds the anti-HFA antibody in an orientated manner. Finally, in the most widely used strategy, covalent binding of anti-HFA antibody to carboxymethyldextran (CM5-dextran) was employed. This immobilization strategy gave the highest anti-HFA antibody immobilization density, whereas the highest HFA response was obtained with the covalent-orientated immobilization strategy. Therefore, the covalent-orientated strategy was the best for SPR-based HFA immunoassay and can detect 0.6-20.0 ng/mL of HFA in less than 10 min.


Subject(s)
Antibodies, Immobilized , Immunoassay/methods , Surface Plasmon Resonance/methods , alpha-2-HS-Glycoprotein/analysis , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Antibodies, Immobilized/metabolism , Dextrans/chemistry , Gold/chemistry , Gold/metabolism , Propylamines , Silanes/chemistry , Staphylococcal Protein A/chemistry , alpha-2-HS-Glycoprotein/immunology
4.
Biomed Microdevices ; 13(4): 759-67, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21559870

ABSTRACT

This paper presents an overview of development of a novel disposable plastic biochip for multiplexed clinical diagnostic applications. The disposable biochip is manufactured using a low-cost, rapid turn- around injection moulding process and consists of nine parabolic elements on a planar substrate. The optical elements are based on supercritical angle fluorescence (SAF) which provides substantial enhancement of the fluorescence collection efficiency but also confines the fluorescence detection volume strictly to the immediate proximity of the biochip surface, thereby having the potential to discriminate against background fluorescence from the analyte solution. An optical reader is also described that enables interrogation and fluorescence collection from the nine optical elements on the chip. The sensitivity of the system was determined with a biotin-avidin assay while its clinical utility was demonstrated in an assay for C-reactive protein (CRP), an inflammation marker.


Subject(s)
Protein Array Analysis/instrumentation , Protein Array Analysis/methods , Avidin/analysis , Biotin/analysis , C-Reactive Protein/analysis , Disposable Equipment , Equipment Design , Fluorescence , Humans
5.
Analyst ; 136(12): 2533-41, 2011 Jun 21.
Article in English | MEDLINE | ID: mdl-21541412

ABSTRACT

In this article, we report on poly(amidoamine) dendrimers (PAMAM) as coupling agents for recombinant single-chain (ScFv) antibodies to nanoparticle (NP) labels, for use in immunoassay. We present a simple theory for the kinetics of particle capture onto a surface by means of an antibody-antigen reaction, in which the important parameter is the fraction of the particle surface that is active for reaction. We describe how increasing the generation number of the linking dendrimers significantly increased the fraction of the NP surface that is active for antigen binding and consequently also increased the assay kinetic rates. Use of dendrimers for conjugation of the NP to the antibody resulted in a significantly higher surface coverage of active antibody, in comparison with mono-valent linker chemistry. As a direct consequence, the increase in effective avidity significantly out-weighed any effect of a decreased diffusion coefficient due to the NP, when compared to that of a molecular dye-labelled antibody. The signal to noise ratio of the G4.5 dendrimer-sensitised nanoparticles out-performed the dye-labelled antibody by approximately four-fold. Particle aggregation experiments with the multi-valent antigen CRP demonstrated reaction-limited aggregation whose rate increased significantly with increasing generation number of the dendrimer linker.


Subject(s)
Dendrimers/chemistry , Immunoassay/methods , Single-Chain Antibodies/chemistry , Kinetics , Nanoparticles/chemistry , Recombinant Proteins/chemistry , Recombinant Proteins/genetics , Recombinant Proteins/metabolism , Single-Chain Antibodies/genetics , Single-Chain Antibodies/immunology
6.
Nat Protoc ; 6(4): 439-45, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21412272

ABSTRACT

This protocol describes an improved and optimized approach to develop rapid and high-sensitivity ELISAs by covalently immobilizing antibody on chemically modified polymeric surfaces. The method involves initial surface activation with KOH and an O(2) plasma, and then amine functionalization with 3-aminopropyltriethoxysilane. The second step requires covalent antibody immobilization on the aminated surface, followed by ELISA. The ELISA procedure developed is 16-fold more sensitive than established methods. This protocol could be used generally as a quantitative analytical approach to perform high-sensitivity and rapid assays in clinical situations, and would provide a faster approach to screen phage-displayed libraries in antibody development facilities. The antibody immobilization procedure is of ∼3 h duration and facilitates rapid ELISAs. This method can be used to perform assays on a wide range of commercially relevant solid support matrices (including those that are chemically inert) with various biosensor formats.


Subject(s)
Enzyme-Linked Immunosorbent Assay/methods , Antibodies, Immobilized/chemistry , Biosensing Techniques/methods , Hydroxides/chemistry , Oxidation-Reduction , Potassium Compounds/chemistry , Propylamines , Sensitivity and Specificity , Silanes/chemistry , Surface Properties
7.
IEEE Trans Biomed Eng ; 58(3): 826-30, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21342809

ABSTRACT

We report a microfluidic chip-based hydrodynamic focusing approach that minimizes sample volume for the analysis of cell-surface interactions under controlled fluid-shear conditions. Assays of statistically meaningful numbers of translocating platelets interacting with immobilized von Willebrand factor at arterial shear rates (∼1500 s(-1)) are demonstrated. By controlling spatial disposition and relative flow rates of two contacting fluid streams, e.g., sample (blood) and aqueous buffer, on-chip hydrodynamic focusing guides the cell-containing stream across the protein surface as a thin fluid layer, consuming ∼50 µL of undiluted whole blood for a 2-min platelet assay. Control of wall shear stress is independent of sample consumption for a given flow time. The device design implements a mass-manufacturable fabrication approach. Fluorescent labeling of cells enables readout using standard microscopy tools. Customized image-analysis software rapidly quantifies cellular surface coverage and aggregate size distributions as a function of time during blood-flow analyses, facilitating assessment of drug treatment efficacy or diagnosis of disease state.


Subject(s)
Blood Platelets/cytology , Microfluidic Analytical Techniques/instrumentation , Platelet Adhesiveness/physiology , Point-of-Care Systems , Blood Platelets/chemistry , Blood Platelets/metabolism , Humans , Image Processing, Computer-Assisted , Immobilized Proteins/chemistry , Immobilized Proteins/metabolism , Platelet Function Tests/instrumentation , Platelet Function Tests/methods , Shear Strength , von Willebrand Factor/chemistry , von Willebrand Factor/metabolism
8.
Biosens Bioelectron ; 26(7): 3213-8, 2011 Mar 15.
Article in English | MEDLINE | ID: mdl-21256731

ABSTRACT

We present a novel approach to the enhancement of surface plasmon-coupled emission (SPCE) using surface plasmon excitation in a bimetal (Ag/Au) layer and we validate the enhancement by presenting the results of a model human IgG immunoassay. Theoretical calculations using Fresnel's equations have been carried out to determine the optimum bimetallic composition and the resulting electric field enhancement. Signal enhancement of SPCE was confirmed using a range of bimetallic layers which were deposited on the surface of a high collection efficiency polymer array biochip and subsequently immobilized with Alexa Fluor 647 labeled anti-human IgG. The bimetallic film of Ag/Au (36/10nm) was determined as an optimum substrate for maximum SPCE signal which was a compromise between the long-term stability of the metal layer and the optimized evanescent field enhancement. An enhanced dose-dependent response was also demonstrated which was ∼3 times greater than that detected with a pure gold layer. A human IgG immunoassay showed a dose-dependent response yielding a limit of detection of 1pg/ml by the 3σ rule. The improved performance of the bimetal layer compared to that of an assay carried out on a pure gold layer is attributed to the enhanced evanescent field intensity of surface plasmons in the bimetal combination which excites more fluorescence hence producing an enhanced SPCE signal. This result demonstrates the potential of the SPCE-based array biochips as a sensitive and high-throughput analysis platform for biomolecular interactions.


Subject(s)
Gold/chemistry , Immunoassay/instrumentation , Immunoglobulin G/analysis , Silver/chemistry , Surface Plasmon Resonance/instrumentation , Antibodies/chemistry , Antibodies/immunology , Cyclic AMP/analogs & derivatives , Cyclic AMP/chemistry , Equipment Design , Fluorescent Dyes/chemistry , Humans , Immunoassay/methods , Immunoglobulin G/immunology , Limit of Detection , Surface Plasmon Resonance/methods
9.
Analyst ; 136(7): 1406-11, 2011 Apr 07.
Article in English | MEDLINE | ID: mdl-21267470

ABSTRACT

The non-specific loss of protein analytes can have a major effect on assay results particularly where the concentrations of such analytes are extremely low and the matrix is complex. This report assesses how the protein incubated in sample tubes may be lost due to adsorption. Use of proteins, such as bovine serum albumin (BSA), may be used to pre-treat tubes to reduce such losses. However, such losses may also be associated with structural perturbations leading to changes in immunogenicity (as a result of alterations in specific epitope-related conformations). This can lead to erroneous results or lack of comparability with a range of methodologies such as the bicinchoninic protein assay and immunoassays or when surface plasmon resonance (SPR)-based approaches are used. A model system to evaluate these phenomena is proposed.


Subject(s)
Enzyme-Linked Immunosorbent Assay/methods , Surface Plasmon Resonance/methods , Adsorption , Animals , Blood Proteins/chemistry , Blood Proteins/immunology , Cattle , Glass/chemistry , Horseradish Peroxidase/chemistry , Humans , Immunoglobulin G/chemistry , Immunoglobulin G/immunology , Mice , Polypropylenes/chemistry , Quinolines/chemistry , Serum Albumin, Bovine/chemistry , Surface Properties , alpha-2-HS-Glycoprotein
10.
Anal Biochem ; 409(1): 7-13, 2011 Feb 01.
Article in English | MEDLINE | ID: mdl-20875778

ABSTRACT

Several new plasma protein biomarkers have been associated with increased risk of cardiovascular events. It would be of great value if sets of these markers could be measured in a multiplexed format at point-of-care settings. A major challenge is the extremely wide concentration range in which different plasma biomarkers are present. Two promising biomarkers for cardiac risk prediction are C-reactive protein (CRP) and N-terminal pro-brain natriuretic peptide (NTproBNP). The concentrations of these markers can differ by more than six orders of magnitude. Here we present a chip-based multiplexed assay for CRP and NTproBNP. The high-concentration analyte, CRP, is analyzed in a competitive format, whereas the low-concentration analyte, NTproBNP, is analyzed in a sandwich format. This allows concurrent measurement of the two analytes in a single multiplexed assay. The dynamic ranges for the two assays were optimized to match the relevant serum concentration ranges; thus, no dilutions were needed. Both assays exhibit good precision (5-15% in the clinically relevant concentration ranges), and the limit of detection for the NTproBNP assay was 5 ng/L. Patient plasma samples were used for comparison with clinical methods, resulting in coefficients of determination (R(2)) of 0.9762 and 0.9606 for NTproBNP and CRP, respectively.


Subject(s)
C-Reactive Protein/analysis , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Protein Array Analysis/methods , Biomarkers/blood , Humans , Point-of-Care Systems
11.
J Colloid Interface Sci ; 354(1): 405-9, 2011 Feb 01.
Article in English | MEDLINE | ID: mdl-21051043

ABSTRACT

We report a method for studying nanoparticle-biosensor surface interactions based on total internal reflection fluorescence (TIRF) microscopy. We demonstrate that this simple technique allows for high throughput screening of non-specific adsorption (NSA) of nanoparticles on surfaces of different chemical composition. Binding events between fluorescent nanoparticles and functionalized Zeonor® surfaces are observed in real-time, giving a measure of the attractive or repulsive properties of the surface and the kinetics of the interaction. Three types of coatings have been studied: one containing a polymerized aminosilane network with terminal -NH(2) groups, a second film with a high density of -COOH surface groups and the third with sterically restraining branched poly(ethylene)glycol (PEG) functionality. TIRF microscopy revealed that the NSA of nanoparticles with negative surface charge on such modified coatings decreased in the following order -NH(2)>-branched PEG>-COOH. The surface specificity of the technique also allows discrimination of the degree of NSA of the same surface at different pH.


Subject(s)
Fluorescent Dyes/chemistry , Microscopy, Fluorescence/methods , Nanoparticles/chemistry , Microscopy, Fluorescence/instrumentation , Models, Molecular , Polystyrenes/chemistry , Protein Binding , Substrate Specificity , Surface Properties
12.
Langmuir ; 26(23): 18125-34, 2010 Dec 07.
Article in English | MEDLINE | ID: mdl-21069990

ABSTRACT

This Article addresses the important issue of the characterization of surface functional groups for optical bioassay applications. We use a model system consisting of spherical dye-doped silica nanoparticles (NPs) that have been functionalized with amine groups whereby the encapsulated cyanine-based near-infrared dye fluorescence acts as a probe of the NP surface environment. This facilitates the identification of the optimum deposition parameters for the formation of a stable ordered amine monolayer and also elucidates the functionalization profile of the amine-silanization process. Specifically, we use a novel approach where the techniques of fluorescence correlation spectroscopy (FCS) and fluorescence lifetime measurement (FL) are used in conjunction with the more conventional analytical techniques of zeta potential measurement and Fourier transfer infrared spectroscopy (FTIR). The dynamics of the ordering of the amine layer in different stages of the reaction have been characterized by FTIR, FL, and FCS. The results indicate an optimum reaction time for the formation of a stable amine layer, which is optimized for further biomolecular conjugation, whereas extended reaction times lead to a disordered cross-linked layer. The results have been validated using an immunoglobulin (IgG) plate-based direct binding assay where the maximum number of IgG-conjugated aminated NPs were captured by immobilized anti-IgG antibodies for the NP sample corresponding to the optimized amine-silanization condition. Importantly, these results point to the potential of FCS and FL as useful analytical tools in diverse fields such as characterization of surface functionalization.


Subject(s)
Amines/chemistry , Nanoparticles/chemistry , Silanes/chemistry , Silicon Dioxide/chemistry , Cross-Linking Reagents/chemistry , Disulfides/chemistry , Fluorescent Dyes/chemistry , Immunoassay/methods , Immunoglobulin G/chemistry , Protein Binding , Spectrometry, Fluorescence/methods , Spectroscopy, Fourier Transform Infrared/methods , Sulfhydryl Compounds/chemistry , Surface Properties , Time Factors
13.
Anal Chem ; 82(16): 7049-52, 2010 Aug 15.
Article in English | MEDLINE | ID: mdl-20704394

ABSTRACT

A highly sensitive and rapid sandwich enzyme-linked immunosorbent assay (ELISA) procedure was developed for the detection of human fetuin A/AHSG (alpha2-HS-glycoprotein), a specific biomarker for hepatocellular carcinoma and atherosclerosis. Anti-human fetuin A antibody was immobilized on aminopropyltriethoxysilane-mediated amine-functionalized microtiter plates using 1-ethyl-3-[3-dimethylaminopropyl]carbodiimide hydrochloride and N-hydroxysulfosuccinimide-based heterobifunctional cross-linking. The analytical sensitivity of the developed assay was 39 pg/mL, compared to 625 pg/mL for the conventional assay. The generic nature of the developed procedure was demonstrated by performing human fetuin A assays on different polymeric matrixes, i.e., polystyrene, poly(methyl methacrylate), and polycyclo-olefin (Zeonex), in a modified microtiter plate format. Thus, the newly developed procedure has considerable advantages over the existing method.


Subject(s)
Blood Proteins/analysis , Enzyme-Linked Immunosorbent Assay/methods , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Atherosclerosis/diagnosis , Biomarkers/analysis , Carcinoma, Hepatocellular/diagnosis , Humans , Liver Neoplasms/diagnosis , Polymers/chemistry , Silanes/chemistry , alpha-2-HS-Glycoprotein
14.
Langmuir ; 26(17): 13741-6, 2010 Sep 07.
Article in English | MEDLINE | ID: mdl-20677746

ABSTRACT

Fluorescence lifetime (FL) analysis and fluorescence correlation spectroscopy (FCS) have been successfully employed to reveal detailed information about the internal architecture of fluorescent silica nanoparticles (NPs). The dual-component lifetime behavior shows a two-domain dye distribution in the NP as a function of solvent accessibility. The introduction of an undoped silica shell serves to stabilize the outer dye fraction that is manifest as an increase in lifetime. The FCS not only shows a size-dependent increase in the cross-correlation decay constant but also demonstrates a significant relaxation in the FCS signal with the introduction of an undoped silica shell.


Subject(s)
Fluorescence , Fluorescent Dyes/chemistry , Nanoparticles/chemistry , Silicon Dioxide/chemistry , Particle Size , Silicon Dioxide/chemical synthesis , Spectrometry, Fluorescence , Surface Properties
15.
Anal Bioanal Chem ; 398(5): 1947-54, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20658227

ABSTRACT

The technique of surface plasmon-coupled emission (SPCE) involves the coupling of light which is emitted from a fluorophore into the surface plasmon of an adjacent thin metal film, giving rise to highly directional emission. We have combined the advantages of SPCE with the high light collection efficiency of supercritical angle fluorescence by carrying out an immunoassay on a paraboloid array biochip in the absence of the conventional SPCE spacer layer normally used to minimize metal quenching of the fluorescence. In this work, we have successfully demonstrated an SPCE-based assay by utilizing the protein assay layer as the spacer layer. A novel 3 × 3 injection molded polymer biochip with paraboloid elements was used. The paraboloid elements served to enhance the light collection efficiency while the top surface was coated with a gold layer to use excitation of surface plasmons and detection of SPCE emission. Theoretical modeling of the gold-protein layer structure showed that the surface plasmon resonance angles were located in the detection range of the paraboloid biochip. The polarization dependence of SPCE emission was also demonstrated. Finally, a human IgG sandwich immunoassay was carried out which exhibited a limit of detection of ~10 ng/ml using 3σ. The results demonstrate the potential of the SPCE-based paraboloid array biochip as a novel platform for high-throughput analysis of biomolecular interactions.


Subject(s)
Immunoassay/instrumentation , Immunoassay/methods , Surface Plasmon Resonance/instrumentation , Surface Plasmon Resonance/methods , Humans , Protein Array Analysis/instrumentation , Protein Array Analysis/methods
16.
Biomed Microdevices ; 12(6): 987-1000, 2010 Dec.
Article in English | MEDLINE | ID: mdl-20652753

ABSTRACT

We report a novel device to analyze cell-surface interactions under controlled fluid-shear conditions on well-characterised protein surfaces. Its performance is demonstrated by studying platelets interacting with immobilised von Willebrand Factor at arterial vascular shear rates using just 200 µL of whole human blood per assay. The device's parallel-plate flow chamber, with 0.1 mm² cross sectional area and height-to-width ratio of 1:40, provides uniform, well-defined shear rates along the chip surface with negligible vertical wall effects on the fluid flow profile while minimizing sample volumetric flow. A coating process was demonstrated by ellipsometry, atomic force microscopy, and fluorescent immunostaining to provide reproducible, homogeneous, uniform protein layers over the 0.7 cm² cell-surface interaction area. Customized image processing quantifies dynamic cellular surface coverage vs. time throughout the whole-blood-flow assay for a given drug treatment or disease state. This device can track the dose response of anti-platelet drugs, is suitable for point-of-care diagnostics, and is designed for adaptation to mass manufacture.


Subject(s)
Arteries/cytology , Arteries/metabolism , Blood Platelets/cytology , Blood Platelets/metabolism , Blood Proteins/metabolism , Mechanical Phenomena , Microfluidic Analytical Techniques/instrumentation , Animals , Animals, Newborn , Antibodies/immunology , Arteries/physiology , Biomechanical Phenomena , Blood Platelets/physiology , Blood Proteins/immunology , Blood Volume , Equipment Design , Humans , Image Processing, Computer-Assisted , Mice , Microscopy, Atomic Force , Platelet Adhesiveness , Protein Binding , Reproducibility of Results , Software , von Willebrand Factor/metabolism
17.
Anal Biochem ; 405(2): 174-83, 2010 Oct 15.
Article in English | MEDLINE | ID: mdl-20513436

ABSTRACT

We report an integrated platelet translocation analysis system that measures complex dynamic platelet-protein surface interactions in microliter volumes of unmodified anticoagulated whole blood under controlled fluid shear conditions. The integrated system combines customized platelet-tracking image analysis with a custom-designed microfluidic parallel plate flow chamber and defined von Willebrand factor surfaces to assess platelet trajectories. Using a position-based probability function that accounts for image noise and preference for downstream movement, outputs include instantaneous and mean platelet velocities, periods of motion and stasis, and bond dissociation kinetics. Whole blood flow data from healthy donors at an arterial shear rate (1500 s(-1)) show mean platelet velocities from 8.9+/-1.0 to 12+/-4 microm s(-1). Platelets in blood treated with the antiplatelet agent c7E-Fab fragment spend more than twice as much time in motion as platelets from untreated control blood; the bond dissociation rate constant (k(off)) increases 1.3-fold, whereas mean translocation velocities do not differ. Blood from healthy unmedicated donors was used to assess flow assay reproducibility, donor variability, and the effects of antiplatelet treatment. This integrated system enables reliable, rapid populational quantification of platelet translocation under pathophysiological vascular fluid shear using as little as 150 microl of blood.


Subject(s)
Blood Platelets/metabolism , von Willebrand Factor/metabolism , Blood Platelets/cytology , Humans , Kinetics , Platelet Adhesiveness , Platelet Aggregation , Platelet Count , Stress, Mechanical , von Willebrand Factor/chemistry
18.
Biosens Bioelectron ; 25(6): 1344-9, 2010 Feb 15.
Article in English | MEDLINE | ID: mdl-19932607

ABSTRACT

We have carried out a human IgG immunoassay on a novel disposable optical array biochip using surface plasmon-coupled emission (SPCE) detection. The work successfully combines the advantages of the highly directional SPCE emission profile and enhanced surface plasmon excitation with the high light collection efficiency achieved using supercritical angle fluorescence (SAF). This is achieved using an array of transparent paraboloid polymer elements which have been coated with a thin gold layer to facilitate SPCE. Moreover, since only the emission of molecules which are close to the metal surface couple into the surface plasmon, the detection is highly surface-specific leading to background suppression and increased signal-to-noise ratio. Theoretical calculations have been carried out in order to match the surface plasmon resonance angles and SPCE emission angles to the paraboloid array features for light collection. A sandwich assay format was used and a dose response curve was obtained in the concentration range 2 ng/ml to 200 microg/ml yielding a limit of detection of 20 ng/ml. This is the first demonstration of an SPCE-based assay on a disposable biochip platform and indicates the potential of SPCE-based arrays for high-throughput analysis of biomolecular interactions.


Subject(s)
Biosensing Techniques/instrumentation , Disposable Equipment , Immunoassay/instrumentation , Protein Array Analysis/instrumentation , Surface Plasmon Resonance/instrumentation , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
19.
J Fluoresc ; 20(1): 215-23, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19821014

ABSTRACT

In this paper, we describe a novel technique for depositing metal nanoparticles (NPs) on a planar substrate whereby the NPs are micro-patterned on the surface by a simple stamp-printing procedure. The method exploits the attractive force between negatively charged colloidal metal NPs and positively-charged polyelectrolyte layers which have been selectively deposited on the surface. Using this technique, large uniform areas of patterned metal NPs, with different plasmonic properties, were achieved by optimisation of the stamping process. We report the observation of unusual fluorescence emission from these structures. The emission was measured using epifluorescence microscopy. Fluorescence lifetime behaviour was also measured. Furthermore, the mu-patterned NPs exhibited blinking behaviour under 469 nm excitation and the fluorescence spectrum was multi-peaked. It has been established that the fluorescence is independent of the plasmon resonance properties of the NPs. As well as optimising the novel NP mu-patterning technique, this work discusses the origin and characteristics of the anomalous fluorescence behaviour in order to characterise and minimise this unwanted background contribution in the use of metal NPs for plasmonic enhancement of fluorescence for optical biochip applications.


Subject(s)
Metal Nanoparticles/chemistry , Optical Phenomena , Silver/chemistry , Aniline Compounds/chemistry , Citrates/chemistry , Electrolytes/chemistry , Polymers/chemistry , Printing , Reproducibility of Results , Silver Nitrate/chemistry , Sodium Citrate , Solubility , Spectrometry, Fluorescence , Surface Properties , Water/chemistry
20.
Anal Bioanal Chem ; 396(3): 1127-34, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20012901

ABSTRACT

In this work, we used a model assay system (polyclonal human IgG-goat antihuman IgG) to elucidate some of the key factors that influence the analytical performance of bioassays that employ metal-enhanced fluorescence (MEF) using silver nanoparticles (NPs). Cy5 dye was used as the fluorescent label, and results were compared with a standard assay performed in the absence of NPs. Two sizes of silver NPs were prepared with respective diameters of 60 +/- 10 and 149 +/- 16 nm. The absorption spectra of the NPs in solution were fitted accurately using Mie theory, and the dipole resonance of the 149-nm NPs in solution was found to match well with the absorption spectrum of Cy5. Such spectral matching is a key factor in optimizing MEF. NPs were deposited uniformly and reproducibly on polyelectrolyte-coated polystyrene substrates. Compared to the standard assay performed without the aid of NPs, significant improvements in sensitivity and in limit of detection (LOD) were obtained for the assay with the 149-nm NPs. An important observation was that the relative enhancement of fluorescence increased as the concentration of antigen increased. The metal-assisted assay data were analyzed using standard statistical methods and yielded a LOD of 0.086 ng/mL for the spectrally matched NPs compared to a value of 5.67 ng/mL obtained for the same assay in the absence of NPs. This improvement of approximately 66x in LOD demonstrates the potential of metal-enhanced fluorescence for improving the analytical performance of bioassays when care is taken to optimize the key determining parameters.


Subject(s)
Immunoassay/methods , Immunoglobulin G/analysis , Metal Nanoparticles/chemistry , Silver/chemistry , Carbocyanines , Fluorescence , Humans , Immunoglobulin G/immunology , Limit of Detection , Metal Nanoparticles/ultrastructure
SELECTION OF CITATIONS
SEARCH DETAIL
...