Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Stroke ; 53(11): 3419-3428, 2022 11.
Article in English | MEDLINE | ID: mdl-35942881

ABSTRACT

BACKGROUND: The utility of magnetic resonance imaging (MRI) brain in patients with transient or minor neurological symptoms is uncertain. We sought to determine the proportion of participants with transient or minor neurological symptoms who had MRI evidence of acute ischemia at different clinical probabilities of transient ischemic attack (TIA) or minor stroke. METHODS: Cohort of participants with transient or minor neurological symptoms from emergency and outpatient settings. Clinicians at different levels of training gave each participant a diagnostic probability (probable when TIA/stroke was the most likely differential diagnosis; possible when TIA/stroke was not the most likely differential diagnosis; or uncertain when diagnostic probability could not be given) before 1.5 or 3T brain MRI ≤5 days from onset. Post hoc, each clinical syndrome was defined blind to MRI findings as National Institute of Neurological Disorders and Stroke criteria TIA/stroke; International Headache Society criteria migraine aura; non-TIA focal symptoms; or nonfocal symptoms. MRI evidence of acute ischemia was defined by 2 reads of MRI. Stroke was ascertained for at least 90 days and up to 18 months after recruitment. RESULTS: Two hundred seventy-two participated (47% female, mean age 60, SD 14), 58% with MRI ≤2 days of onset. Most (92%) reported focal symptoms. MR evidence of acute ischemia was found, for stroke/TIA clinical probabilities of probable 23 out of 75 (31% [95% CI, 21%-42%]); possible 26 out of 151 (17% [12%-24%]); and uncertain 9 out of 43, (20% [10%-36%]). MRI evidence of acute ischemia was found in National Institute of Neurological Disorders and Stroke criteria TIA/stroke 40 out of 95 (42% [32%-53%]); migraine aura 4 out of 38 (11% [3%-25%]); non-TIA focal symptoms 16 out of 99 (16% [10%-25%]); and no focal features 1 out of 29 (3% [0%-18%]). After MRI, a further 14 (5% [95% CI, 3-8]) would be treated with an antiplatelet drug compared with treatment plan before MRI. By 18 months, a new ischemic stroke occurred in 9 out of 61 (18%) patients with MRI evidence of acute ischemia and 2 out of 211 (1%) without (age-adjusted hazard ratio, 13 [95% CI, 3-62]; P<0.0001). CONCLUSIONS: MRI evidence of acute brain ischemia was found in about 1 in 6 transient or minor neurological symptoms patients with a nonstroke/TIA initial diagnosis or uncertain diagnosis. Methods to determine the clinical and cost-effectiveness of MRI are needed in this population.


Subject(s)
Epilepsy , Ischemic Attack, Transient , Migraine with Aura , Stroke , Humans , Female , Middle Aged , Male , Ischemic Attack, Transient/diagnosis , Prospective Studies , Platelet Aggregation Inhibitors , Stroke/epidemiology , Magnetic Resonance Imaging , Cohort Studies
2.
Health Technol Assess ; 23(40): 1-194, 2019 08.
Article in English | MEDLINE | ID: mdl-31397263

ABSTRACT

BACKGROUND: Delirium is a common and serious neuropsychiatric syndrome, usually triggered by illness or drugs. It remains underdetected. One reason for this is a lack of brief, pragmatic assessment tools. The 4 'A's test (Arousal, Attention, Abbreviated Mental Test - 4, Acute change) (4AT) is a screening tool designed for routine use. This project evaluated its usability, diagnostic accuracy and cost. METHODS: Phase 1 - the usability of the 4AT in routine practice was measured with two surveys and two qualitative studies of health-care professionals, and a review of current clinical use of the 4AT as well as its presence in guidelines and reports. Phase 2 - the 4AT's diagnostic accuracy was assessed in newly admitted acute medical patients aged ≥ 70 years. Its performance was compared with that of the Confusion Assessment Method (CAM; a longer screening tool). The performance of individual 4AT test items was related to cognitive status, length of stay, new institutionalisation, mortality at 12 weeks and outcomes. The method used was a prospective, double-blind diagnostic test accuracy study in emergency departments or in acute general medical wards in three UK sites. Each patient underwent a reference standard delirium assessment and was also randomised to receive an assessment with either the 4AT (n = 421) or the CAM (n = 420). A health economics analysis was also conducted. RESULTS: Phase 1 found evidence that delirium awareness is increasing, but also that there is a need for education on delirium in general and on the 4AT in particular. Most users reported that the 4AT was useful, and it was in widespread use both in the UK and beyond. No changes to the 4AT were considered necessary. Phase 2 involved 785 individuals who had data for analysis; their mean age was 81.4 (standard deviation 6.4) years, 45% were male, 99% were white and 9% had a known dementia diagnosis. The 4AT (n = 392) had an area under the receiver operating characteristic curve of 0.90. A positive 4AT score (> 3) had a specificity of 95% [95% confidence interval (CI) 92% to 97%] and a sensitivity of 76% (95% CI 61% to 87%) for reference standard delirium. The CAM (n = 382) had a specificity of 100% (95% CI 98% to 100%) and a sensitivity of 40% (95% CI 26% to 57%) in the subset of participants whom it was possible to assess using this. Patients with positive 4AT scores had longer lengths of stay (median 5 days, interquartile range 2.0-14.0 days) than did those with negative 4AT scores (median 2 days, interquartile range 1.0-6.0 days), and they had a higher 12-week mortality rate (16.1% and 9.2%, respectively). The estimated 12-week costs of an initial inpatient stay for patients with delirium were more than double the costs of an inpatient stay for patients without delirium (e.g. in Scotland, £7559, 95% CI £7362 to £7755, vs. £4215, 95% CI £4175 to £4254). The estimated cost of false-positive cases was £4653, of false-negative cases was £8956, and of a missed diagnosis was £2067. LIMITATIONS: Patients were aged ≥ 70 years and were assessed soon after they were admitted, limiting generalisability. The treatment of patients in accordance with reference standard diagnosis limited the ability to assess comparative cost-effectiveness. CONCLUSIONS: These findings support the use of the 4AT as a rapid delirium assessment instrument. The 4AT has acceptable diagnostic accuracy for acute older patients aged > 70 years. FUTURE WORK: Further research should address the real-world implementation of delirium assessment. The 4AT should be tested in other populations. TRIAL REGISTRATION: Current Controlled Trials ISRCTN53388093. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 40. See the NIHR Journals Library website for further project information. The funder specified that any new delirium assessment tool should be compared against the CAM, but had no other role in the study design or conduct of the study.


Delirium is the sudden onset of confusion that can happen when someone is unwell. It is common in older people who go into hospital, and it is upsetting for both the patients and their families. Delirium is important to diagnose, because people with delirium do less well than those without, and it is often treatable. The ideal way to diagnose delirium is with a full assessment by a specialist, but this is expensive and time-consuming. We therefore developed a short test called the 4 'A's Test (4AT). The four 'A's stand for Arousal, Attention, Abbreviated Mental Test ­ 4, and Acute change. First, we interviewed hospital staff about delirium and the 4AT. We found that the 4AT was already widely used and that people found it easy to use. We then tested how the 4AT performed in practice. A total of 785 recently admitted patients aged ≥ 70 years participated, of whom around one in eight had delirium. A researcher carried out the full standard delirium assessment on each patient and then a different researcher carried out the 4AT. A normal 4AT score reliably ruled out delirium. An abnormal score was also reasonably effective in detecting delirium, but staff still needed to follow up such patients with a full assessment. People with higher 4AT scores stayed in hospital longer and were more likely to die, and their treatment was more expensive. We conclude that the 4AT is a useful test to rule out delirium or to see if more detailed testing is required. It could help treat patients correctly and quickly. This would save money and improve outcomes.


Subject(s)
Delirium/diagnosis , Emergency Service, Hospital , Mass Screening , Surveys and Questionnaires/standards , Aged , Double-Blind Method , Female , Humans , Male , Prospective Studies , Sensitivity and Specificity , United Kingdom
3.
BMC Med ; 17(1): 138, 2019 07 24.
Article in English | MEDLINE | ID: mdl-31337404

ABSTRACT

BACKGROUND: Delirium affects > 15% of hospitalised patients but is grossly underdetected, contributing to poor care. The 4 'A's Test (4AT, www.the4AT.com ) is a short delirium assessment tool designed for routine use without special training. The primary objective was to assess the accuracy of the 4AT for delirium detection. The secondary objective was to compare the 4AT with another commonly used delirium assessment tool, the Confusion Assessment Method (CAM). METHODS: This was a prospective diagnostic test accuracy study set in emergency departments or acute medical wards involving acute medical patients aged ≥ 70. All those without acutely life-threatening illness or coma were eligible. Patients underwent (1) reference standard delirium assessment based on DSM-IV criteria and (2) were randomised to either the index test (4AT, scores 0-12; prespecified score of > 3 considered positive) or the comparator (CAM; scored positive or negative), in a random order, using computer-generated pseudo-random numbers, stratified by study site, with block allocation. Reference standard and 4AT or CAM assessments were performed by pairs of independent raters blinded to the results of the other assessment. RESULTS: Eight hundred forty-three individuals were randomised: 21 withdrew, 3 lost contact, 32 indeterminate diagnosis, 2 missing outcome, and 785 were included in the analysis. Mean age was 81.4 (SD 6.4) years. 12.1% (95/785) had delirium by reference standard assessment, 14.3% (56/392) by 4AT, and 4.7% (18/384) by CAM. The 4AT had an area under the receiver operating characteristic curve of 0.90 (95% CI 0.84-0.96). The 4AT had a sensitivity of 76% (95% CI 61-87%) and a specificity of 94% (95% CI 92-97%). The CAM had a sensitivity of 40% (95% CI 26-57%) and a specificity of 100% (95% CI 98-100%). CONCLUSIONS: The 4AT is a short, pragmatic tool which can help improving detection rates of delirium in routine clinical care. TRIAL REGISTRATION: International standard randomised controlled trial number (ISRCTN) 53388093 . Date applied 30/05/2014; date assigned 02/06/2014.


Subject(s)
Confusion/diagnosis , Delirium/diagnosis , Diagnostic Tests, Routine , Neuropsychological Tests , Acute Disease , Aged , Aged, 80 and over , Algorithms , Checklist/methods , Checklist/standards , Diagnostic Tests, Routine/methods , Diagnostic Tests, Routine/standards , Diagnostic and Statistical Manual of Mental Disorders , Emergency Service, Hospital , Female , Geriatric Assessment/methods , Humans , Inpatients , Male , Neuropsychological Tests/standards , Predictive Value of Tests , Reproducibility of Results , Sensitivity and Specificity
4.
Emerg Med J ; 35(8): 477-485, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29921622

ABSTRACT

OBJECTIVES: Diagnosing underlying arrhythmia in ED syncope patients remains problematic. This study investigates diagnostic yield, event prevalence, patient satisfaction and compliance, and influence on resource utilisation of an ambulatory patch monitor in unexplained ED syncope patients. METHODS: Prospective pilot study conducted in a single tertiary ED in Scotland between 17 November 2015 and 16 June 2017 with a historical unmatched comparator group. Patients 16 years or over presenting within 6 hours of unexplained syncope were fitted in the ED with an ambulatory patch ECG recorder (Zio XT monitor), which continuously records a single-lead ECG for up to 14 days. Patients with an obvious underlying cause were excluded. An unmatched historical group of 603 syncope patients with no obvious diagnosis in ED, recruited to a prior cohort study (2007-2008), were used as a comparator. Primary endpoint was symptomatic significant arrhythmia at 90-day follow-up. RESULTS: During the prospective study period, 86 patients were recruited. 90-day diagnostic yield for symptomatic significant arrhythmia was 10.5% (95% CI 4.0 to 16.9; 9 of 86) versus 2.0% (95% CI 0.9 to 3.1; 12 of 603) in the comparator group. 24 patients (27.9%) had a significant arrhythmia (five serious); 26 patients (30.2%) had serious outcomes (major adverse cardiac event and/or death). Blinded patch report review suggested the patch would significantly reduce requirement for standard outpatient ambulatory ECG monitoring. 56 of 76 returned patches had a diagnostic finding within±45 s of a triggered/diary event (73.7% diagnostic utility; 95% CI 63.7 to 83.6); 34 of 56 (61%) for sinus rhythm or ectopic beats only. CONCLUSIONS: Routine, early ambulatory ECG monitoring in ED patients with unexplained syncope is probably warranted. A large-scale trial comparing this approach to standard care with cost-effectiveness and safety analysis is now required. TRIAL REGISTRATION: NCT02683174.


Subject(s)
Electrocardiography, Ambulatory/instrumentation , Emergency Service, Hospital , Syncope/diagnosis , Aged , Female , Humans , Male , Middle Aged , Patient Compliance , Patient Satisfaction , Pilot Projects , Prospective Studies , Scotland
5.
BMJ Open ; 8(2): e015572, 2018 02 10.
Article in English | MEDLINE | ID: mdl-29440152

ABSTRACT

INTRODUCTION: Delirium is a severe neuropsychiatric syndrome of rapid onset, commonly precipitated by acute illness. It is common in older people in the emergency department (ED) and acute hospital, but greatly under-recognised in these and other settings. Delirium and other forms of cognitive impairment, particularly dementia, commonly coexist. There is a need for a rapid delirium screening tool that can be administered by a range of professional-level healthcare staff to patients with sensory or functional impairments in a busy clinical environment, which also incorporates general cognitive assessment. We developed the 4 'A's Test (4AT) for this purpose. This study's primary objective is to validate the 4AT against a reference standard. Secondary objectives include (1) comparing the 4AT with another widely used test (the Confusion Assessment Method (CAM)); (2) determining if the 4AT is sensitive to general cognitive impairment; (3) assessing if 4AT scores predict outcomes, including (4) a health economic analysis. METHODS AND ANALYSIS: 900 patients aged 70 or over in EDs or acute general medical wards will be recruited in three sites (Edinburgh, Bradford and Sheffield) over 18 months. Each patient will undergo a reference standard delirium assessment and will be randomised to assessment with either the 4AT or the CAM. At 12 weeks, outcomes (length of stay, institutionalisation and mortality) and resource utilisation will be collected by a questionnaire and via the electronic patient record. ETHICS AND DISSEMINATION: Ethical approval was granted in Scotland and England. The study involves administering tests commonly used in clinical practice. The main ethical issues are the essential recruitment of people without capacity. Dissemination is planned via publication in high impact journals, presentation at conferences, social media and the website www.the4AT.com. TRIAL REGISTRATION NUMBER: ISRCTN53388093; Pre-results.


Subject(s)
Delirium/diagnosis , Diagnostic Tests, Routine/standards , Geriatric Assessment/methods , Aged , Aged, 80 and over , Emergency Service, Hospital , Female , Humans , Logistic Models , Male , Patients' Rooms , Prospective Studies , Research Design , Severity of Illness Index , Surveys and Questionnaires , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL
...