Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
Add more filters










Publication year range
1.
Transplant Proc ; 39(10): 3465-7, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18089409

ABSTRACT

Tacrolimus is used widely for immunosuppression following transplantation. It has rarely been linked to the development of peripheral neuropathy. However, one study also reported improvement in peripheral neuropathy after tacrolimus use. We have reported herein two patients who developed chronic sensorimotor polyneuropathy after tacrolimus use following renal transplantation. One patient had an unusual presentation with bilateral facial and extremity weakness and a relapsing course. The other patient presented with focal sensory symptoms in one hand. Electrophysiological studies confirmed widespread, predominantly demyelinating or axonal polyneuropathy. We concluded that patients on tacrolimus should be carefully monitored for symptoms suggestive of peripheral neuropathy.


Subject(s)
Kidney Transplantation/immunology , Peripheral Nervous System Diseases/chemically induced , Polyneuropathies/chemically induced , Tacrolimus/adverse effects , Adult , Female , Humans , Immunosuppressive Agents/adverse effects , Male , Middle Aged , Neural Conduction , Postoperative Complications/chemically induced
3.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 1620-3, 2006.
Article in English | MEDLINE | ID: mdl-17946912

ABSTRACT

Transcranial magnetic stimulation (TMS), by providing a method of stimulating human brain without the need for surgical exposure or significant discomfort, facilitated the study of cerebral functions in both normal subjects and patients. The aspects of TMS treated include: (1) The part(s) of neurons readily direct excited by TMS; (2) the optimal relationship between the orientations of the electric field induced by TMS and the directly excited neurons; (3) the transynaptic effects of the directly excited neurons that are either distant or local; (4) the effects of repetitive versus single pulse TMS.


Subject(s)
Action Potentials/physiology , Brain/physiology , Evoked Potentials/physiology , Neurons/physiology , Synaptic Transmission/physiology , Transcranial Magnetic Stimulation/methods , Action Potentials/radiation effects , Animals , Brain/radiation effects , Evoked Potentials/radiation effects , Humans , Neurons/radiation effects , Synaptic Transmission/radiation effects
5.
J Neurosci Methods ; 86(2): 209-19, 1999 Jan.
Article in English | MEDLINE | ID: mdl-10065987

ABSTRACT

Although transcranial magnetic stimulation (TMS) has been introduced only recently, it is safe and provides a painless, inexpensive noninvasive method for the evaluation of brain function. Determining central motor conduction time (CMCT) permits assessment of the corticospinal pathways. Mapping the central representation of muscles provides a method for investigating the cortical reorganization that follows training, amputation and injury to the central nervous system. Such studies of human plasticity may have important implications for neurorehabilitation. TMS also provides a method whereby cortical excitability can be noninvasively evaluated, which is likely to have important implications in the study of epilepsy, movement disorders and related conditions. TMS is useful in tracking the flow of information from one brain region to another and in investigations of cognition and functional localization, thereby complementing information obtained using functional imaging techniques, which have superior spatial but inferior temporal resolution. Finally, TMS is currently being investigated as a method for establishing cerebral dominance and as a therapeutic tool in the treatment of depression. Investigations for treatment of other neurologic and psychiatric conditions are likely to be undertaken.


Subject(s)
Cerebral Cortex/physiology , Electromagnetic Fields , Magnetoencephalography/methods , Animals , Humans , Neural Pathways/anatomy & histology , Neural Pathways/physiology , Neuronal Plasticity/physiology , Visual Pathways/anatomy & histology , Visual Pathways/physiology
6.
Article in English | MEDLINE | ID: mdl-10689455

ABSTRACT

The fact that TMS of cerebral cortex is associated with inhibitory as well as excitatory properties is important because it makes it possible to investigate interconnections between cortical areas and tracing these functional interconnections by a noninvasive excitation or inhibition and temporary interference with the flow of impulses in the cerebral cortex. An important tool is thereby added to the analysis of higher cortical functions.


Subject(s)
Cerebral Cortex/cytology , Cerebral Cortex/physiology , Transcranial Magnetic Stimulation , Electric Stimulation , Humans , Neural Pathways
7.
J Physiol ; 513 ( Pt 2): 571-85, 1998 Dec 01.
Article in English | MEDLINE | ID: mdl-9807005

ABSTRACT

1. Mammalian phrenic nerve, in a trough filled with saline, was excited by magnetic coil (MC)-induced stimuli at defined stimulation sites, including the negative-going first spatial derivative of the induced electric field along a straight nerve, at a bend in the nerve, and at a cut nerve ending. At all such sites, the largest amplitude response for a given stimulator output setting was elicited by an induced damped polyphasic pulse consisting of an initial quarter-cycle hyperpolarization followed by a half-cycle depolarization compared with a predominantly 'monophasic' quarter-cycle depolarization. 2. Simulation studies demonstrated that the increased efficacy of the induced quarter-cycle hyperpolarizing-half-cycle depolarizing polyphasic pulse was mainly attributed to the greater duration of the outward membrane current phase, resulting in a greater outward charge transfer afforded by the half-cycle (i.e. quarter-cycles 2 and 3). The advantage of a fast rising initial quarter-cycle depolarization was more than offset by the slower rising, but longer duration depolarizing half-cycle. 3. Simulation further revealed that the quarter-cycle hyperpolarization-half-cycle depolarization showed only a 2.6 % lowering of peak outward current and a 3.5 % lowering of outward charge transfer at threshold, compared with a half-cycle depolarization alone. Presumably, this slight increase in efficacy reflects modest reversal of Na+ inactivation by the very brief initial hyperpolarization. 4. In vitro, at low bath temperature, the nerve response to an initial quarter-cycle depolarization declined in amplitude as the second hyperpolarizing phase progressively increased in amplitude and duration. This 'pull-down' phenomenon nearly disappeared as the bath temperature approached 37 C. Possibly, at the reduced temperature, delay in generation of the action potential permitted the hyperpolarization phase to reduce excitation. 5. Pull-down was not observed in the thenar muscle responses to median nerve stimulation in a normal human at normal temperature. However, pull-down emerged when the median nerve was cooled by placing ice over the forearm. 6. In a nerve at subnormal temperature straddled with non-conducting inhomogeneities, polyphasic pulses of either polarity elicited the largest responses. This was also seen when stimulating distal median nerve at normal temperature. These results imply excitation by hyperpolarizing-depolarizing pulse sequences at two separate sites. Similarly, polyphasic pulses elicited the largest responses from nerve roots and motor cortex. 7. The pull-down phenomenon has a possible clinical application in detecting pathologically slowed activation of Na+ channels. The current direction of the polyphasic waveform may become a significant factor with the increasing use of repetitive magnetic stimulators which, for technical reasons, induce a cosine-shaped half-cycle, preceded and followed by quarter-cycles of opposite polarity.


Subject(s)
Magnetics , Peripheral Nerves/physiology , Animals , Computer Simulation , Electric Stimulation , Electrophysiology , Forearm/physiology , Humans , Median Nerve/physiology , Models, Neurological , Muscle, Skeletal/physiology , Phrenic Nerve/physiology , Physical Stimulation/methods , Swine , Temperature , Thumb/physiology
8.
J Clin Neurophysiol ; 15(4): 288-304, 1998 Jul.
Article in English | MEDLINE | ID: mdl-9736464

ABSTRACT

The authors critically reviewed experiments in which transcranial magnetic stimulation (TMS) and repetitive TMS (rTMS) of the higher visual pathway were used. Topics include basic mechanisms of neural excitation by TMS and their relevance to the visual pathway (excitatory and inhibitory effects), TMS and rTMS of calcarine cortex (suppression, unmasking, and phosphenes), TMS of V5 (suppression), TMS and rTMS of higher level temporoparietooccipital areas (perceptual errors, unmasking, and inattention), the role of frontal lobe output in visual perception, and vocalization of perceived visual stimuli (role of consciousness of linguistic symbols).


Subject(s)
Electromagnetic Fields , Evoked Potentials, Visual/physiology , Reading , Visual Pathways/physiology , Attention/physiology , Awareness/physiology , Cerebral Cortex/physiology , Excitatory Postsynaptic Potentials , Humans , Models, Neurological , Neural Conduction/physiology , Neural Inhibition/physiology , Pattern Recognition, Visual/physiology , Perceptual Distortion/physiology , Perceptual Masking/physiology , Phosphenes/physiology , Photic Stimulation , Physical Stimulation , Psychophysics , Speech/physiology
9.
Electroencephalogr Clin Neurophysiol ; 101(2): 153-66, 1996 Apr.
Article in English | MEDLINE | ID: mdl-8647020

ABSTRACT

Using principles derived from electric field measurements and studies of phrenic nerve in vitro, neuromagnetic stimuli in humans were predicted to excite selective low threshold sites in proximal and distal cauda equina. Physical models, in which induced electric fields were recorded in a segment of human lumbosacral spine immersed in a saline filled tank, supported this prediction. Conclusions from the model were tested and confirmed in normal human subjects. Ipsilateral motor evoked potentials were elicited in lower limb muscles and striated sphincters by magnetic coil (MC) stimulation of both proximal and distal cauda equina. Over proximal cauda equina a vertically oriented MC junction and cranially directed induced current elicited a newly identified compound muscle action potential (CMAP). The F response latency and lack of attenuation when the target muscle was vibrated suggest that the proximal response is a directly elicited M response arising near or at the rootlet exit zone of the conus medullaris. Over distal cauda equina, lumbar roots were optimally excited by a horizontally oriented MC junction, and sacral roots by an approximately vertically oriented MC junction, eliciting CMAPs with similar appearance but shorter latency consistent with the known intrathecal lengths of the lower lumbar and sacral nerve roots. The induced current was usually most effective when directed towards the spinal fluid filled thecal sac. Normal subjects showed stable CMAP onset latencies elicited at proximal and distal cauda equina despite wide variation in amplitude. Thus, cauda equina conduction time can be directly calculated. This new method may improve the detection and classification of peripheral neuropathies affecting lower limbs and striated sphincters.


Subject(s)
Cauda Equina/physiology , Electromyography/methods , Magnetics , Neural Conduction/physiology , Adult , Electric Stimulation , Female , Humans , Lumbosacral Region/innervation , Lumbosacral Region/physiology , Male , Muscle, Skeletal/innervation , Muscle, Skeletal/physiology , Peripheral Nerves/physiology , Sacrum/innervation , Sacrum/physiology , Spinal Canal/physiology , Spinal Nerve Roots/physiology , Thigh/innervation , Thigh/physiology , Time Factors
10.
Adv Neurol ; 67: 79-106, 1995.
Article in English | MEDLINE | ID: mdl-8848984

ABSTRACT

It is hoped that this survey conveys a sense of the many positive uses of focal and nonfocal MC stimulation already manifest within a decade of its introduction. As with other techniques of investigating brain function, MC stimulation has its relative advantages and disadvantages. The precision of defining the site of MC effects currently is inferior to that achieved with PET scanning, but the precision of timing of effects is superior, being on the order of milliseconds. Perhaps the special value of MC stimulation is in moving closer to specifying cause-effect relationships, through interference or facilitatory effects, than when techniques yielding more circumstantial evidence are used. However, it is the testing and cross-validation of the conclusions from the different modes of neuroscientific inquiry that we look to in synthesizing explanations of brain function.


Subject(s)
Brain/physiology , Transcranial Magnetic Stimulation , Cerebral Cortex/physiology , Evoked Potentials/physiology , Frontal Lobe/physiology , Ganglia, Sensory/physiology , Humans , Motor Cortex/physiology , Neural Pathways/physiology
11.
Article in English | MEDLINE | ID: mdl-7511518

ABSTRACT

Human perception of 3 briefly flashed letters in a horizontal array that subtends a visual angle of 3 degrees or less is reduced by a magnetic coil (MC) pulse given, e.g., 90 msec later. Either a round or a double square MC is effective when the lower windings or central junction region, respectively, are tangential to the skull overlying calcarine cortex and symmetrical across the midline. The modeled, induced electric field has peak amplitude at the midline, but the peak spatial derivatives lie many centimeters laterally. Thus, the foveal representation near the midline is closer to the peak electric field than to its peak spatial derivatives, i.e., excitation of calcarine cortex differs from excitation of a straight nerve. With an MC pulse that induces an electric field which is substantially monophasic in amplitude, the lateral-most letter (usually the right-hand letter) in the trigram is preferentially suppressed when the electric field in the contralateral occipital lobe is directed towards the midline. Inferences from using peripheral nerve models imply that medially located bends in geniculo-calcarine or corticofugal fibers are the relevant sites of excitation in visual suppression; end excitation of fiber arborizations or apical dendrites is considered less likely. This conclusion is supported by the fact that the induced electric field polarity in paracentral lobule for optimally eliciting foot movements is opposite to that for visual suppression, the major bends occurring at different portions of the fiber trajectories in the two systems.


Subject(s)
Electromagnetic Fields , Magnetics , Visual Cortex/physiology , Humans , Photic Stimulation
12.
Electroencephalogr Clin Neurophysiol ; 93(1): 68-74, 1994 Feb.
Article in English | MEDLINE | ID: mdl-7511524

ABSTRACT

The performance of a 4-leaf magnetic coil was evaluated during magnetic stimulation of a peripheral nerve in vitro. The site of stimulation was below the coil center, and a 90 degrees rotation of the coil was equivalent to a change in current polarity. A hyperpolarizing magnetic stimulus failed to slow or block a propagating action potential.


Subject(s)
Electric Stimulation/instrumentation , Electric Stimulation/methods , Magnetics , Peripheral Nerves/physiology , Animals , Electromagnetic Fields , Equipment Design , In Vitro Techniques , Phrenic Nerve/physiology , Swine
13.
Brain ; 116 ( Pt 3): 511-25, 1993 Jun.
Article in English | MEDLINE | ID: mdl-8513390

ABSTRACT

The amplitudes of motor evoked potentials to transcranial magnetic stimulation from muscles immediately proximal to a temporarily anaesthetized (Bier's block) human forearm increase in minutes after the onset of anaesthesia and return to control values after the anaesthesia subsides. In order to determine the level at which the early modulation of human motor outputs takes place, we recorded maximal H reflexes, peripheral M responses, motor evoked potentials to transcranial magnetic stimulation, and motor evoked potentials to transcranial electrical stimulation and spinal electrical stimulation from a muscle immediately proximal to a limb segment made ischaemic by a pneumatic tourniquet. The amplitudes of motor evoked potentials to transcranial magnetic stimulation, but not to transcranial electrical stimulation and spinal electrical stimulation, were larger during ischaemia, implying that the site of change was in the motor cortex. The maximal H/M ratios were unaffected by ischaemia, indicating that alpha-motor neuron excitability to segmental Ia inputs remained unchanged. The map of cortical representation areas for this muscle obtained with transcranial magnetic stimulation was also enlarged. Taken together, our findings suggest that the temporary removal by ischaemic nerve block of myelinated afferent inputs reduces inhibition at the motor cortical level and that this disinhibition is responsible for the increased excitability of the corticospinal system.


Subject(s)
Evoked Potentials , Ischemia/physiopathology , Motor Cortex/physiopathology , Muscles/blood supply , Adult , Aged , Forearm/blood supply , Forearm/innervation , Humans , Leg/blood supply , Leg/innervation , Magnetoencephalography , Middle Aged , Muscles/innervation , Nerve Block , Neural Pathways/physiopathology
14.
Brain Res ; 605(2): 317-21, 1993 Mar 12.
Article in English | MEDLINE | ID: mdl-8386969

ABSTRACT

Previous work disclosed that single magnetic coil (MC) pulses applied over human calcarine cortex could suppress perception of letters briefly presented, e.g. 80-100 ms earlier. Although individual MC stimuli presented 0-60 ms, or more than 140 ms after the visual stimulus were apparently ineffective, combinations of 2 or 3 MC pulses at such intervals temporarily depressed visual perception. Thus, progressing of such language information could be slowed, without being abolished. By contrast, when the first MC pulse was delivered 120 ms or later, a second MC pulse 40 ms later had no detectable effect, implying that calcarine cortex had already transmitted the information. Perceptual recovery of 5-character words initially occurred no earlier than that of random letters, nor or random letters vs. arbitrary linear patterns, implying that the processing delays in calcarine cortex were similar.


Subject(s)
Magnetics , Mental Processes/physiology , Reaction Time/physiology , Visual Cortex/physiology , Humans , Photic Stimulation , Synaptic Transmission/physiology , Visual Perception/physiology
15.
Brain Res ; 605(2): 312-6, 1993 Mar 12.
Article in English | MEDLINE | ID: mdl-8481781

ABSTRACT

Visual suppression by a magnetic coil (MC) pulse delivered over human calcarine cortex after a transient visual stimulus 80-100 ms earlier has been used to suppress the representation of a 'masking' visual stimulus and thus to unmask a 'target' visual stimulus given, e.g., 100 ms before the mask. The resulting target unmasking as a function of the interval between mask and MC pulse is approximately the inverse of the visual suppression curve. Arbitrary visual linear patterns can similarly be unmasked. At the long target-mask interval used, the site of masking is deduced to lie beyond calcarine cortex. In several right-handed subjects tested, powerful MC stimulation of the left (but not right) temporo-parieto-occipital cortex also led to (weaker) unmasking.


Subject(s)
Functional Laterality/physiology , Magnetics , Perceptual Masking/physiology , Visual Cortex/physiology , Visual Perception/physiology , Humans , Photic Stimulation
16.
J Physiol ; 460: 201-19, 1993 Jan.
Article in English | MEDLINE | ID: mdl-8487192

ABSTRACT

1. According to classical cable theory, a magnetic coil (MC) should excite a linear nerve fibre in a homogeneous medium at the negative-going first spatial derivative of the induced electric field. This prediction was tested by MC stimulation of mammalian phrenic and amphibian sciatic nerve and branches in vitro, immersed in Ringer solution within a trough, and identifying the sites of excitation by recording responses of similar latency to local electrical stimulation. Subsequently, the identified sites of excitation were compared with measurements of the induced electric field and its calculated first spatial derivative. A special hardware device was used to selectively reverse MC current direction and to generate predominantly monophasic- or polyphasic-induced pulse profiles whose initial phases were identical in polarity, shape and amplitude. When using the amphibian nerve preparation, a complication was excitation at low threshold points related to cut branches. 2. Reversal of monophasic current resulted in latency shifts corresponding approximately to the distance between induced cathode and anode. The location of each site of excitation was at, or very near, the negative-going first spatial derivative peaks of the induced electric field measured parallel to the straight nerve. Significantly, excitation of the nerve did not occur at the peak of the induced electric field above the centre of the 'figure of eight' MC junction. 3. A polyphasic pulse excited the nerve at both sites, by the negative-going first phase at one location, and approximately 150 microseconds later, by the reversed negative-going second phase at the other location. Polyphasic and monophasic pulses elicited responses with similar latency when the induced current flowed towards the recording electrode. 4. Straddling a nerve with non-coding solid lucite cylinders created a localized spatial narrowing and increase in the induced electric field, resulting in a lowered threshold of excitation. The corresponding closer spacing between first spatial derivative peaks was exhibited by a significant reduction in latency shift when MC current direction was reversed. 5. When a nerve is bent and the induced current is directed along the nerve towards the bend, the threshold of excitation is reduced there. Increasing the angle of the bend from 0 deg to more than 90 deg graded the decrease in threshold. 6. In a straight nerve the threshold was lowest when current was directed towards the cut end.(ABSTRACT TRUNCATED AT 400 WORDS)


Subject(s)
Amphibians/physiology , Electromagnetic Fields , Mammals/physiology , Peripheral Nerves/physiology , Action Potentials/physiology , Animals , Bufo marinus/physiology , Cats , Electric Stimulation , In Vitro Techniques , Macaca/physiology , Peripheral Nerves/anatomy & histology , Rana catesbeiana/physiology , Sheep/physiology , Swine/physiology
18.
Electroencephalogr Clin Neurophysiol ; 85(5): 291-301, 1992 Oct.
Article in English | MEDLINE | ID: mdl-1385089

ABSTRACT

To help elucidate some basic principles of magnetic coil (MC) excitation of cerebral cortex, a model system was devised in which mammalian phrenic nerve, or amphibian sciatic nerve with its branches was suspended in appropriate Ringer's solution in a human brain-shaped volume conductor, an inverted plastic skull. The nerve was recorded monophasically out of the volume conductor. The site of nerve excitation by the MC was identified by finding where along the nerve a bipolar electrical stimulus yielded a similar action potential latency. MC excitation of hand-related corticospinal (CT) neurons was modelled by giving the distal end of nerve attached to the lateral skull an initial radial (perpendicular) trajectory, with subsequent bends towards the base and posterior part of the skull; this nerve was optimally excited by a laterally placed figure 8 or round MC when the induced electric field led to outward membrane current at the initial bend. By contrast, nerve given a trajectory modelling CT neurons related to the foot was optimally excited when the coil windings were across the midline, but again when membrane current flowed outward at the first bend. Corticocortical fibers were modelled by placing the nerve in the anteroposterior axis lateral to the midline; with the round MC vertex-tangentially orientated, optimal excitation occurred at the bend nearest the interaural line, i.e., near the peak electric field. The findings emphasize the importance of orientation and direction of current in the MC and fiber bends in determining nerve excitation. The findings in the peripheral nerve-skull model help explain (1) why lateral and vertex-tangentially orientated MCs preferentially excite arm-related CT neurons directly and indirectly (through corticocortical fibers), respectively, and (2) why the MC orientations for optimally exciting directly arm and leg-related CT neurons differ.


Subject(s)
Cerebral Cortex/physiology , Magnetics , Models, Neurological , Peripheral Nerves/physiology , Action Potentials/physiology , Animals , Bufo marinus , Cats , Electric Stimulation , Electromyography , Humans , In Vitro Techniques , Macaca , Models, Structural , Muscles/physiology , Rana catesbeiana
19.
Muscle Nerve ; 15(8): 865-75, 1992 Aug.
Article in English | MEDLINE | ID: mdl-1495503

ABSTRACT

Filtering of evoked potentials has been performed in clinical laboratories using both analog and digital methods. Analog methods introduce distortion caused by nonlinear phase shift which may be quite severe. Digital methods, while avoiding distortion caused by phase shift, reveal evoked potential components which may or may not correspond to distinct singular neuroanatomic generators or homogeneous neuroanatomic systems. Thus, components identified with zero phase shift digital filters at restricted bandpass must be compared with components seen in open bandpass recordings. In some specific circumstances, high-pass filtering of short-latency somatosensory-evoked potentials may distinguish slow asynchronous synaptic activity from fast and synchronous synaptic, lemniscal, or axonal activity.


Subject(s)
Electrodiagnosis , Evoked Potentials , Signal Processing, Computer-Assisted , Analog-Digital Conversion , Fourier Analysis , Humans , Neurophysiology , Software
20.
Electroencephalogr Clin Neurophysiol ; 85(4): 265-72, 1992 Aug.
Article in English | MEDLINE | ID: mdl-1380914

ABSTRACT

Focal stimulation over human cerebellum with a figure 8 magnetic coil (MC) results in an evoked wave recorded from bipolar scalp electrodes on the interaural line and more anteriorly. In 3 subjects, the wave responses along the interaural line had latencies of 8.8-13.8 msec, lasted 17.4-29.0 msec and had a maximum amplitude of 14.4-26.8 microV. The responses were recorded more anteriorly from leads midway between the interaural line and frontal leads; responses recorded from frontal leads were up to 3.5 msec later. The evoked wave was preceded by a diphasic EMG response with a latency of 1.2-2.0 msec. Analysis of the averaged responses recorded by adjoining bipolar leads indicated that the response was predominantly surface positive and crossed. Control experiments eliminated eye movement and somatosensory input as explanations of the evoked response, thereby identifying it as a cortical response. The surface positive wave in humans was compared with the responses recorded in cat and monkey to cerebellar stimulation. The responses in humans could reflect dysfacilitation through MC activation of Purkinje cells, or feed-forward facilitation through transsynaptic or antidromic activation of dentate neurons. The latency of the surface positive wave exceeds that of cerebellar inhibition of MC elicited hand muscle responses, but the discrepancy is at least partly accounted for by the extra delay required to set up the indirect cortico-spinal component required for motoneuron discharge. Estimates made of the cerebello-frontal cortical and peripheral feedback loop times suggest that the central has less than one quarter the delay of the peripheral loop, which would be especially advantageous during fast skilled movements of the fingers.


Subject(s)
Cerebellum/physiology , Frontal Lobe/physiology , Magnetics , Electroencephalography , Electromyography , Evoked Potentials/physiology , Humans , Male , Reaction Time/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...