Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
PLoS One ; 19(5): e0303846, 2024.
Article in English | MEDLINE | ID: mdl-38820372

ABSTRACT

There is an urgent need for rapid, non-sputum point-of-care diagnostics to detect tuberculosis. This prospective trial in seven high tuberculosis burden countries evaluated the diagnostic accuracy of the point-of-care urine-based lipoarabinomannan assay FUJIFILM SILVAMP TB LAM (FujiLAM) among inpatients and outpatients living with HIV. Diagnostic performance of FujiLAM was assessed against a mycobacterial reference standard (sputum culture, blood culture, and Xpert Ultra from urine and sputum at enrollment, and additional sputum culture ≤7 days from enrollment), an extended mycobacterial reference standard (eMRS), and a composite reference standard including clinical evaluation. Of 1637 participants considered for the analysis, 296 (18%) were tuberculosis positive by eMRS. Median age was 40 years, median CD4 cell count was 369 cells/ul, and 52% were female. Overall FujiLAM sensitivity was 54·4% (95% CI: 48·7-60·0), overall specificity was 85·2% (83·2-87·0) against eMRS. Sensitivity and specificity estimates varied between sites, ranging from 26·5% (95% CI: 17·4%-38·0%) to 73·2% (60·4%-83·0%), and 75·0 (65·0%-82·9%) to 96·5 (92·1%-98·5%), respectively. Post-hoc exploratory analysis identified significant variability in the performance of the six FujiLAM lots used in this study. Lot variability limited interpretation of FujiLAM test performance. Although results with the current version of FujiLAM are too variable for clinical decision-making, the lipoarabinomannan biomarker still holds promise for tuberculosis diagnostics. The trial is registered at clinicaltrials.gov (NCT04089423).


Subject(s)
HIV Infections , Tuberculosis , Humans , Female , Male , Adult , HIV Infections/complications , HIV Infections/diagnosis , Prospective Studies , Tuberculosis/diagnosis , Middle Aged , Sensitivity and Specificity , Mycobacterium tuberculosis/isolation & purification , Lipopolysaccharides/urine , Sputum/microbiology
2.
Virol J ; 21(1): 99, 2024 04 29.
Article in English | MEDLINE | ID: mdl-38685117

ABSTRACT

BACKGROUND: During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests' clinical accuracy. METHODS: We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. RESULTS: We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer's instructions and those conducted differently, or between point-of-care and lab-based testing. CONCLUSION: Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.


Subject(s)
Antigens, Viral , COVID-19 Serological Testing , COVID-19 , SARS-CoV-2 , Sensitivity and Specificity , Humans , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/immunology , COVID-19 Serological Testing/methods , Antigens, Viral/immunology , Antigens, Viral/analysis , COVID-19 Testing/methods
3.
Sci Rep ; 13(1): 21913, 2023 12 11.
Article in English | MEDLINE | ID: mdl-38081881

ABSTRACT

Self-testing is an effective tool to bridge the testing gap for several infectious diseases; however, its performance in detecting SARS-CoV-2 using antigen-detection rapid diagnostic tests (Ag-RDTs) has not been systematically reviewed. This study aimed to inform WHO guidelines by evaluating the accuracy of COVID-19 self-testing and self-sampling coupled with professional Ag-RDT conduct and interpretation. Articles on this topic were searched until November 7th, 2022. Concordance between self-testing/self-sampling and fully professional-use Ag-RDTs was assessed using Cohen's kappa. Bivariate meta-analysis yielded pooled performance estimates. Quality and certainty of evidence were evaluated using QUADAS-2 and GRADE tools. Among 43 studies included, twelve reported on self-testing, and 31 assessed self-sampling only. Around 49.6% showed low risk of bias. Overall concordance with professional-use Ag-RDTs was high (kappa 0.91 [95% confidence interval (CI) 0.88-0.94]). Comparing self-testing/self-sampling to molecular testing, the pooled sensitivity and specificity were 70.5% (95% CI 64.3-76.0) and 99.4% (95% CI 99.1-99.6), respectively. Higher sensitivity (i.e., 93.6% [95% CI 90.4-96.8] for Ct < 25) was estimated in subgroups with higher viral loads using Ct values as a proxy. Despite high heterogeneity among studies, COVID-19 self-testing/self-sampling exhibits high concordance with professional-use Ag-RDTs. This suggests that self-testing/self-sampling can be offered as part of COVID-19 testing strategies.Trial registration: PROSPERO: CRD42021250706.


Subject(s)
COVID-19 Testing , COVID-19 , Humans , SARS-CoV-2 , COVID-19/diagnosis , Rapid Diagnostic Tests , Self-Testing , Sensitivity and Specificity
5.
PLoS Med ; 19(5): e1004011, 2022 05.
Article in English | MEDLINE | ID: mdl-35617375

ABSTRACT

BACKGROUND: Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. METHODS AND FINDINGS: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched preprint and peer-reviewed databases for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariable mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1). When manufacturer instructions were followed, sensitivity increased to 76.3% (95% CI 73.7 to 78.7). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values <20 and <25, compared to 54.4% [95% CI 47.3 to 61.5] and 18.7% [95% CI 13.9 to 23.4] for Ct-values ≥25 and ≥30) and was estimated to increase by 2.9 percentage points (95% CI 1.7 to 4.0) for every unit decrease in mean Ct-value when adjusting for testing procedure and patients' symptom status. Concordantly, we found the mean Ct-value to be lower for true positive (22.2 [95% CI 21.5 to 22.8]) compared to false negative (30.4 [95% CI 29.7 to 31.1]) results. Testing in the first week from symptom onset resulted in substantially higher sensitivity (81.9% [95% CI 77.7 to 85.5]) compared to testing after 1 week (51.8%, 95% CI 41.5 to 61.9). Similarly, sensitivity was higher in symptomatic (76.2% [95% CI 73.3 to 78.9]) compared to asymptomatic (56.8% [95% CI 50.9 to 62.4]) persons. However, both effects were mainly driven by the Ct-value of the sample. With regards to sample type, highest sensitivity was found for nasopharyngeal (NP) and combined NP/oropharyngeal samples (70.8% [95% CI 68.3 to 73.2]), as well as in anterior nasal/mid-turbinate samples (77.3% [95% CI 73.0 to 81.0]). Our analysis was limited by the included studies' heterogeneity in viral load assessment and sample origination. CONCLUSIONS: Ag-RDTs detect most of the individuals infected with SARS-CoV-2, and almost all (>90%) when high viral loads are present. With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Point-of-Care Systems , Sensitivity and Specificity
6.
Microbiol Spectr ; 9(2): e0025021, 2021 10 31.
Article in English | MEDLINE | ID: mdl-34549999

ABSTRACT

During the last year, mass screening campaigns have been carried out to identify immunological response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and establish a possible seroprevalence. The obtained results gained new importance with the beginning of the SARS-CoV-2 vaccination campaign, as the lack of doses has persuaded several countries to introduce different policies for individuals who had a history of COVID-19. Lateral flow assays (LFAs) may represent an affordable tool to support population screening in low-middle-income countries, where diagnostic tests are lacking and epidemiology is still widely unknown. However, LFAs have demonstrated a wide range of performance, and the question of which one could be more valuable in these settings still remains. We evaluated the performance of 11 LFAs in detecting SARS-CoV-2 infection, analyzing samples collected from 350 subjects. In addition, samples from 57 health care workers collected at 21 to 24 days after the first dose of the Pfizer-BioNTech vaccine were also evaluated. LFAs demonstrated a wide range of specificity (92.31% to 100%) and sensitivity (50% to 100%). The analysis of postvaccination samples was used to describe the most suitable tests to detect IgG response against S protein receptor binding domain (RBD). Tuberculosis (TB) therapy was identified as a potential factor affecting the specificity of LFAs. This analysis identified which LFAs represent a valuable tool not only for the detection of prior SARS-CoV-2 infection but also for the detection of IgG elicited in response to vaccination. These results demonstrated that different LFAs may have different applications and the possible risks of their use in high-TB-burden settings. IMPORTANCE Our study provides a fresh perspective on the possible employment of SARS-CoV-2 LFA antibody tests. We developed an in-depth, large-scale analysis comparing LFA performance to enzyme-linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA) and evaluating their sensitivity and specificity in identifying COVID-19 patients at different time points from symptom onset. Moreover, for the first time, we analyzed samples of patients undergoing treatment for endemic poverty-related diseases, especially tuberculosis, and we evaluated the impact of this therapy on test specificity in order to assess possible performance in TB high-burden countries.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19 Vaccines/immunology , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , BNT162 Vaccine , COVID-19/diagnosis , Electrochemical Techniques , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunoassay/methods , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Mass Screening/methods , Point-of-Care Testing , Sensitivity and Specificity , Tuberculosis/diagnosis , Young Adult
7.
PLoS Med ; 18(8): e1003735, 2021 08.
Article in English | MEDLINE | ID: mdl-34383750

ABSTRACT

BACKGROUND: SARS-CoV-2 antigen rapid diagnostic tests (Ag-RDTs) are increasingly being integrated in testing strategies around the world. Studies of the Ag-RDTs have shown variable performance. In this systematic review and meta-analysis, we assessed the clinical accuracy (sensitivity and specificity) of commercially available Ag-RDTs. METHODS AND FINDINGS: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched multiple databases (PubMed, Web of Science Core Collection, medRvix, bioRvix, and FIND) for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 up until 30 April 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity in comparison to reverse transcription polymerase chain reaction (RT-PCR) testing. We assessed heterogeneity by subgroup analyses, and rated study quality and risk of bias using the QUADAS-2 assessment tool. From a total of 14,254 articles, we included 133 analytical and clinical studies resulting in 214 clinical accuracy datasets with 112,323 samples. Across all meta-analyzed samples, the pooled Ag-RDT sensitivity and specificity were 71.2% (95% CI 68.2% to 74.0%) and 98.9% (95% CI 98.6% to 99.1%), respectively. Sensitivity increased to 76.3% (95% CI 73.1% to 79.2%) if analysis was restricted to studies that followed the Ag-RDT manufacturers' instructions. LumiraDx showed the highest sensitivity, with 88.2% (95% CI 59.0% to 97.5%). Of instrument-free Ag-RDTs, Standard Q nasal performed best, with 80.2% sensitivity (95% CI 70.3% to 87.4%). Across all Ag-RDTs, sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values, i.e., <20 (96.5%, 95% CI 92.6% to 98.4%) and <25 (95.8%, 95% CI 92.3% to 97.8%), in comparison to those with Ct ≥ 25 (50.7%, 95% CI 35.6% to 65.8%) and ≥30 (20.9%, 95% CI 12.5% to 32.8%). Testing in the first week from symptom onset resulted in substantially higher sensitivity (83.8%, 95% CI 76.3% to 89.2%) compared to testing after 1 week (61.5%, 95% CI 52.2% to 70.0%). The best Ag-RDT sensitivity was found with anterior nasal sampling (75.5%, 95% CI 70.4% to 79.9%), in comparison to other sample types (e.g., nasopharyngeal, 71.6%, 95% CI 68.1% to 74.9%), although CIs were overlapping. Concerns of bias were raised across all datasets, and financial support from the manufacturer was reported in 24.1% of datasets. Our analysis was limited by the included studies' heterogeneity in design and reporting. CONCLUSIONS: In this study we found that Ag-RDTs detect the vast majority of SARS-CoV-2-infected persons within the first week of symptom onset and those with high viral load. Thus, they can have high utility for diagnostic purposes in the early phase of disease, making them a valuable tool to fight the spread of SARS-CoV-2. Standardization in conduct and reporting of clinical accuracy studies would improve comparability and use of data.


Subject(s)
COVID-19 Serological Testing/methods , Age Factors , Antigens, Viral/analysis , COVID-19/diagnosis , COVID-19/etiology , COVID-19 Serological Testing/standards , Carrier State/diagnosis , Carrier State/virology , Humans , Nasopharynx/virology , Reagent Kits, Diagnostic , Reference Standards , SARS-CoV-2/immunology , Sensitivity and Specificity , Viral Load
8.
Diagn Microbiol Infect Dis ; 101(1): 115397, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34130215

ABSTRACT

In a manufacturer-independent laboratory validation study, the Xpert MTB/XDR® assay demonstrated equivalent limit of detection to Xpert MTB/RIF®, detected 100% of tested resistance mutations and showed some utility for resistance detection in strain mixtures. The Xpert MTB/XDR assay is a reliable, sensitive assay for tuberculosis and expanded resistance detection.


Subject(s)
Drug Resistance, Bacterial/genetics , Molecular Diagnostic Techniques , Tuberculosis, Multidrug-Resistant/diagnosis , Antibiotics, Antitubercular/pharmacology , Bacterial Proteins/genetics , Drug Resistance, Bacterial/drug effects , Microbial Sensitivity Tests , Mutation , Mycobacterium tuberculosis/drug effects , Mycobacterium tuberculosis/genetics , Mycobacterium tuberculosis/isolation & purification , Sensitivity and Specificity , Tuberculosis/diagnosis
9.
Eur Respir J ; 58(5)2021 10.
Article in English | MEDLINE | ID: mdl-34049948

ABSTRACT

BACKGROUND: Bringing reliable and accurate tuberculosis (TB) diagnosis closer to patients is a key priority for global TB control. Molbio Diagnostics have developed the Truenat point-of-care molecular assays for detection of TB and rifampicin (RIF) resistance. METHODS: We conducted a prospective multicentre diagnostic accuracy study at 19 primary healthcare centres and seven reference laboratories in Peru, India, Ethiopia and Papua New Guinea to estimate the diagnostic accuracy of the point-of-care Truenat MTB, MTB Plus and MTB-RIF Dx assays for pulmonary TB using culture and phenotypic drug susceptibility testing as the reference standard, compared with Xpert MTB/RIF or Ultra. RESULTS: Of 1807 enrolled participants with TB signs/symptoms, 24% were culture-positive for Mycobacterium tuberculosis, of which 15% were RIF-resistant. In microscopy centres, the pooled sensitivity of Truenat MTB and Truenat MTB Plus was 73% (95% CI 67-78%) and 80% (95% CI 75-84%), respectively. Among smear-negative specimens, sensitivities were 36% (95% CI 27-47%) and 47% (95% CI 37-58%), respectively. Sensitivity of Truenat MTB-RIF was 84% (95% CI 62-95%). Truenat assays showed high specificity. Head-to-head comparison in the central reference laboratories suggested that the Truenat assays have similar performance to Xpert MTB/RIF. CONCLUSION: We found the performance of Molbio's Truenat MTB, MTB Plus and MTB-RIF Dx assays to be comparable to that of the Xpert MTB/RIF assay. Performing the Truenat tests in primary healthcare centres with very limited infrastructure was feasible. These data supported the development of a World Health Organization policy recommendation of the Molbio assays.


Subject(s)
Antibiotics, Antitubercular , Mycobacterium tuberculosis , Tuberculosis , Antibiotics, Antitubercular/therapeutic use , Drug Resistance, Bacterial , Humans , Microbial Sensitivity Tests , Prospective Studies , Sensitivity and Specificity , Sputum , Tuberculosis/diagnosis , Tuberculosis/drug therapy
10.
Diagnostics (Basel) ; 11(5)2021 Apr 22.
Article in English | MEDLINE | ID: mdl-33921930

ABSTRACT

Point-of-care diagnostics have the potential to increase diagnosis and linkage to care and help reach the WHO targets to eliminate hepatitis C virus (HCV) by 2030. Here, we evaluated the diagnostic accuracy of Genedrive HCV ID assay for the qualitative detection of HCV RNA in decentralized settings in two low- and middle-income countries using fresh plasma specimens from 426 participants. The Abbott RealTime HCV assay was used as the gold standard. Genedrive HCV ID assay was conducted by different users. Users also completed questionnaires to assess the usability of Genedrive. At detection thresholds of 12 IU/mL or 30 IU/mL, 1000 IU/mL, and 2362 IU/mL, the sensitivity was 96.2% (95% CI: 92.7-98.4), 100% (98.2-100), and 100% (98.2-100), respectively; the specificity was 99.5% (95% CI: 97.4-100), 99.5% (97.5-100), and 98.7% (96.1-100), respectively. All genotypes detected using the gold-standard assay were also detected with Genedrive. Users found Genedrive easy to use. Genedrive is a simple and accurate test to confirm chronic HCV infection in decentralized, real-life, resource-limited settings. This novel diagnostic tool could contribute to closing the current gap in HCV diagnosis.

12.
Lancet Infect Dis ; 21(3): 376-384, 2021 03.
Article in English | MEDLINE | ID: mdl-33316214

ABSTRACT

BACKGROUND: A sensitive and specific non-sputum-based test would be groundbreaking for the diagnosis of childhood tuberculosis. We assessed side by side the diagnostic accuracy of the urine-based lipoarabinomannan assays Fujifilm SILVAMP TB LAM (FujiLAM) and Alere Determine TB LAM Ag (AlereLAM) for detection of childhood tuberculosis. METHODS: In this cross-sectional study, we tested urine samples from children younger than 15 years with presumed pulmonary tuberculosis. Children were consecutively recruited from four dedicated outpatient childhood tuberculosis clinics in The Gambia, Mali, Nigeria, and Tanzania. Biobanked urine samples were thawed and tested using FujiLAM and AlereLAM assays. We measured diagnostic performance against a microbiological reference standard (confirmed tuberculosis) and a composite reference standard (confirmed and unconfirmed tuberculosis). Sensitivity and specificity were estimated with bivariate random-effects meta-analyses. FINDINGS: Between July 1, 2017, and Dec 1, 2018, we obtained and stored urine samples from 415 children. 63 (15%) children had confirmed tuberculosis, 113 (27%) had unconfirmed tuberculosis, and 239 (58%) were unlikely to have tuberculosis. 61 children were HIV-positive (prevalence 15%). Using the microbiological reference standard, the sensitivity of FujiLAM was 64·9% (95% CI 43·7-85·2; positive in 40 of 63 confirmed samples) and the sensitivity of AlereLAM was 30·7% (8·6-61·6; 19 of 63). The specificity of FujiLAM was 83·8% (95% CI 76·5-89·4; negative in 297 of 352 unconfirmed and unlikely samples) and the specificity of AlereLAM was 87·8% (79·0-93·7; 312 of 352). Against the composite reference standard, both assays had decreased sensitivity; the sensitivity of FujiLAM was 32·9% (95% CI 24·6-41·9; positive in 58 of 176 confirmed and unconfirmed samples) and the sensitivity of AlereLAM was 20·2% (12·3-29·4; 36 of 176). The specificity of FujiLAM was 83·3% (95% CI 71·8-91·7; negative in 202 of 239 unlikely samples) and the specificity of AlereLAM was 90·0% (81·6-95·6; 216 of 239). INTERPRETATION: By comparison with AlereLAM, FujiLAM showed higher sensitivity and similar specificity. FujiLAM could potentially add value to the rapid diagnosis of tuberculosis in children. FUNDING: German Federal Ministry of Education and Research, the Global Health Innovative Technology Fund, the UK Research and Innovation Global Challenges Research Fund, and the UK Medical Research Council.


Subject(s)
HIV Seropositivity , Lipopolysaccharides/urine , Tuberculosis, Pulmonary/diagnosis , Tuberculosis, Pulmonary/urine , Child , Child, Preschool , Cross-Sectional Studies , Female , Gambia , Humans , Infant , Mali , Nigeria , Outpatients , Sensitivity and Specificity , Tanzania
13.
BMJ Glob Health ; 5(10)2020 10.
Article in English | MEDLINE | ID: mdl-33087393

ABSTRACT

Acute febrile illness (AFI) is one of the most common reasons for seeking medical care in low-income and middle-income countries. Bacterial infections account for a relatively small proportion of AFIs; however, in the absence of a simple diagnostic test to guide clinical decisions, healthcare professionals often presume that a non-malarial febrile illness is bacterial in origin, potentially resulting in inappropriate antibiotic use. An accurate differential diagnostic tool for AFIs is thus essential, to both limit antibiotic use to bacterial infections and address the antimicrobial resistance crisis that is emerging globally, without resorting to multiple or complex pathogen-specific assays. The Biomarker for Fever-Diagnostic (BFF-Dx) study is one of the largest fever biomarker studies ever undertaken. We collected samples and classified disease aetiology in more than 1900 individuals, distributed among enrolment centres in three countries on two continents. Identical protocols were followed at each study site, and the same analyses were conducted in each setting, enabling like-with-like comparisons to be made among the large sample set generated. The BFF-Dx methodology can act as a model for other researchers, facilitating wider utility of the work in the future. The established sample collection is now accessible to researchers and companies and will facilitate the development of future fever-related diagnostic tests. Here, we outline the methodology used to determine the sample populations and to differentiate bacterial versus non-bacterial AFIs. Future publications will set out in more detail the study's demographics, the causes of fever identified and the performance of selected biomarkers.


Subject(s)
Bacterial Infections , Bacterial Infections/diagnosis , Fever/diagnosis , Fever/etiology , Humans
14.
PLoS Med ; 17(5): e1003113, 2020 05.
Article in English | MEDLINE | ID: mdl-32357197

ABSTRACT

BACKGROUND: Tuberculosis (TB) is the most common cause of death in people living with HIV (PLHIV), yet TB often goes undiagnosed since many patients are not able to produce a sputum specimen, and traditional diagnostics are costly or unavailable. A novel, rapid lateral flow assay, Fujifilm SILVAMP TB LAM (SILVAMP-LAM), detects the presence of TB lipoarabinomannan (LAM) in urine, and is substantially more sensitive for diagnosing TB in PLHIV than an earlier LAM assay (Alere Determine TB LAM lateral flow assay [LF-LAM]). Here, we present an individual participant data meta-analysis of the diagnostic accuracy of SILVAMP-LAM in adult PLHIV, including both published and unpublished data. METHODS AND FINDINGS: Adult PLHIV (≥18 years) were assessed in 5 prospective cohort studies in South Africa (3 cohorts), Vietnam, and Ghana, carried out during 2012 to 2017. Of the 1,595 PLHIV who met eligibility criteria, the majority (61%) were inpatients, median age was 37 years (IQR 30-43), 43% had a CD4 count ≤ 100 cells/µl, and 35% were receiving antiretroviral therapy. Most participants (94%) had a positive WHO symptom screen for TB on enrollment, and 45% were diagnosed with microbiologically confirmed TB, using mycobacterial culture or Xpert MTB/RIF testing of sputum, urine, or blood. Previously published data from inpatients were combined with unpublished data from outpatients. Biobanked urine samples were tested, using blinded double reading, with SILVAMP-LAM and LF-LAM. Applying a microbiological reference standard for assessment of sensitivity, the overall sensitivity for TB detection was 70.7% (95% CI 59.0%-80.8%) for SILVAMP-LAM compared to 34.9% (95% CI 19.5%-50.9%) for LF-LAM. Using a composite reference standard (which included patients with both microbiologically confirmed as well as clinically diagnosed TB), SILVAMP-LAM sensitivity was 65.8% (95% CI 55.9%-74.6%), and that of LF-LAM 31.4% (95% CI 19.1%-43.7%). In patients with CD4 count ≤ 100 cells/µl, SILVAMP-LAM sensitivity was 87.1% (95% CI 79.3%-93.6%), compared to 56.0% (95% CI 43.9%-64.9%) for LF-LAM. In patients with CD4 count 101-200 cells/µl, SILVAMP-LAM sensitivity was 62.7% (95% CI 52.4%-71.9%), compared to 25.3% (95% CI 15.8%-34.9%) for LF-LAM. In those with CD4 count > 200 cells/µl, SILVAMP-LAM sensitivity was 43.9% (95% CI 34.3%-53.9%), compared to 10.9% (95% CI 5.2%-18.4%) for LF-LAM. Using a microbiological reference standard, the specificity of SILVAMP-LAM was 90.9% (95% CI 87.2%-93.7%), and that of LF-LAM 95.3% (95% CI 92.2%-97.7%). Limitations of this study include the use of biobanked, rather than fresh urine samples, and testing by skilled laboratory technicians in research laboratories, rather than at the point of care. CONCLUSIONS: In this study, we found that SILVAMP-LAM identified a substantially higher proportion of TB patients in PLHIV than LF-LAM. The sensitivity of SILVAMP-LAM was highest in patients with CD4 count ≤ 100 cells/µl. Further work is needed to demonstrate accuracy when implemented as a point-of-care test.


Subject(s)
HIV Infections/complications , Lipopolysaccharides/analysis , Tuberculosis, Pulmonary/diagnosis , Tuberculosis/diagnosis , Adult , Ambulatory Care Facilities , Female , Humans , Male , Point-of-Care Systems , Prospective Studies
15.
Open Forum Infect Dis ; 7(1): ofz530, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31976353

ABSTRACT

BACKGROUND: The novel Fujifilm SILVAMP TB-LAM (FujiLAM) assay detects mycobacterial lipoarabinomannan in urine and has demonstrated superior sensitivity to the Alere Determine TB-LAM Ag (AlereLAM) assay for detection of tuberculosis among hospitalized people with human immunodeficiency virus (PWH). This is the first study to evaluate the assay among a broad population referred for antiretroviral therapy including both outpatients (mainly) and inpatients. METHODS: We assessed diagnostic accuracy of FujiLAM and AlereLAM assays in biobanked urine samples from a cohort of adults referred for antiretroviral therapy in Ghana against a microbiological and a composite (including clinical judgement) reference standard, and we assessed the association of FujiLAM test positivity with mortality. RESULTS: We evaluated urine samples from 532 PWH (462 outpatients, 70 inpatients). Against a microbiological reference standard, the sensitivity of FujiLAM was 74.2% (95% confidence interval [CI], 62.0-84.2) compared to 53.0% (95% CI, 40.3-65.4) for AlereLAM, a difference of 21.2% (CI, 13.1-32.5). Specificity was 89.3% (95% CI, 85.8-92.2) versus 95.6% (95% CI, 93.0-97.4) for FujiLAM and AlereLAM, a difference of -6.3% (95% CI -9.6 to -3.3). Specificity estimates for FujiLAM increased markedly to 98.8% (95% CI, 96.6-99.8) in patients with CD4 >100 cells/µL and when using a composite reference standard. FujiLAM test positivity was associated with increased cumulative risk of mortality at 6 months (hazard ratio, 4.80; 95% CI, 3.01-7.64). CONCLUSIONS: FujiLAM offers significantly increased diagnostic sensitivity in comparison to AlereLAM. Specificity estimates for FujiLAM were lower than for AlereLAM but were affected by the limited ability of the reference standard to correctly diagnose tuberculosis in individuals with low CD4 counts.

16.
Lancet Infect Dis ; 19(8): 852-861, 2019 08.
Article in English | MEDLINE | ID: mdl-31155318

ABSTRACT

BACKGROUND: Most tuberculosis-related deaths in people with HIV could be prevented with earlier diagnosis and treatment. The only commercially available tuberculosis point-of-care test (Alere Determine TB LAM Ag [AlereLAM]) has suboptimal sensitivity, which restricts its use in clinical practice. The novel Fujifilm SILVAMP TB LAM (FujiLAM) assay has been developed to improve the sensitivity of AlereLAM. We assessed the diagnostic accuracy of the FujiLAM assay for the detection of tuberculosis in hospital inpatients with HIV compared with the AlereLAM assay. METHODS: For this diagnostic accuracy study, we assessed biobanked urine samples obtained from the FIND Specimen Bank and the University of Cape Town Biobank, which had been collected from hospital inpatients (aged ≥18 years) with HIV during three independent prospective cohort studies done at two South African hospitals. Urine samples were tested using FujiLAM and AlereLAM assays. The conduct and reporting of each test was done blind to other test results. The primary objective was to assess the diagnostic accuracy of FujiLAM compared with AlereLAM, against microbiological and composite reference standards (including clinical diagnoses). FINDINGS: Between April 18, 2018, and May 3, 2018, urine samples from 968 hospital inpatients with HIV were evaluated. The prevalence of microbiologically-confirmed tuberculosis was 62% and the median CD4 count was 86 cells per µL. Using the microbiological reference standard, the estimated sensitivity of FujiLAM was 70·4% (95% CI 53·0 to 83·1) compared with 42·3% (31·7 to 51·8) for AlereLAM (difference 28·1%) and the estimated specificity of FujiLAM was 90·8% (86·0 to 94·4) and 95·0% (87·7-98·8) for AlereLAM (difference -4·2%). Against the composite reference standard, the specificity of both assays was higher (95·7% [92·0 to 98·0] for FujiLAM vs 98·2% [95·7 to 99·6] for AlereLAM; difference -2·5%), but the sensitivity of both assays was lower (64·9% [50·1 to 76·7] for FujiLAM vs 38·2% [28·1 to 47·3] for AlereLAM; difference 26·7%). INTERPRETATION: In comparison to AlereLAM, FujiLAM offers superior diagnostic sensitivity, while maintaining specificity, and could transform rapid point-of-care tuberculosis diagnosis for hospital inpatients with HIV. The applicability of FujiLAM for settings of intended use requires prospective assessment. FUNDING: Global Health Innovative Technology Fund, UK Department for International Development, Dutch Ministry of Foreign Affairs, Bill & Melinda Gates Foundation, German Federal Ministry of Education and Research, Australian Department of Foreign Affairs and Trade, Wellcome Trust, Department of Science and Technology and National Research Foundation of South Africa, and South African Medical Research Council.


Subject(s)
Antigens, Bacterial/urine , HIV Infections/complications , Lipopolysaccharides , Point-of-Care Testing , Tuberculosis , Adult , CD4 Lymphocyte Count , Female , Hospitals , Humans , Male , Prevalence , Prospective Studies , Sensitivity and Specificity , South Africa/epidemiology , Tuberculosis/diagnosis , Tuberculosis/epidemiology
17.
PLoS Med ; 16(4): e1002794, 2019 04.
Article in English | MEDLINE | ID: mdl-31039166

ABSTRACT

BACKGROUND: Accurate, comprehensive, and timely detection of drug-resistant tuberculosis (TB) is essential to inform patient treatment and enable public health surveillance. This is crucial for effective control of TB globally. Whole-genome sequencing (WGS) and targeted next-generation sequencing (NGS) approaches have potential as rapid in vitro diagnostics (IVDs), but the complexity of workflows, interpretation of results, high costs, and vulnerability of instrumentation have been barriers to broad uptake outside of reference laboratories, especially in low- and middle-income countries. A new, solid-state, tabletop sequencing instrument, Illumina iSeq100, has the potential to decentralize NGS for individual patient care. METHODS AND FINDINGS: In this study, we evaluated WGS and targeted NGS for TB on both the new iSeq100 and the widely used MiSeq (both manufactured by Illumina) and compared sequencing performance, costs, and usability. We utilized DNA libraries produced from Mycobacterium tuberculosis clinical isolates for the evaluation. We conducted WGS on three strains and observed equivalent uniform genome coverage with both platforms and found the depth of coverage obtained was consistent with the expected data output. Utilizing the standardized, cloud-based ReSeqTB bioinformatics pipeline for variant analysis, we found the two platforms to have 94.0% (CI 93.1%-94.8%) agreement, in comparison to 97.6% (CI 97%-98.1%) agreement for the same libraries on two MiSeq instruments. For the targeted NGS approach, 46 M. tuberculosis-specific amplicon libraries had 99.6% (CI 98.0%-99.9%) agreement between the iSeq100 and MiSeq data sets in drug resistance-associated SNPs. The upfront capital costs are almost 5-fold lower for the iSeq100 ($19,900 USD) platform in comparison to the MiSeq ($99,000 USD); however, because of difference in the batching capabilities, the price per sample for WGS was higher on the iSeq100. For WGS of M. tuberculosis at the minimum depth of coverage of 30x, the cost per sample on the iSeq100 was $69.44 USD versus $28.21 USD on the MiSeq, assuming a 2 × 150 bp run on a v3 kit. In terms of ease of use, the sequencing workflow of iSeq100 has been optimized to only require 27 minutes total of hands-on time pre- and post-run, and the maintenance is simplified by a single-use cartridge-based fluidic system. As these are the first sequencing attempts on the iSeq100 for M. tuberculosis, the sequencing pool loading concentration still needs optimization, which will affect sequencing error and depth of coverage. Additionally, the costs are based on current equipment and reagent costs, which are subject to change. CONCLUSIONS: The iSeq100 instrument is capable of running existing TB WGS and targeted NGS library preparations with comparable accuracy to the MiSeq. The iSeq100 has reduced sequencing workflow hands-on time and is able to deliver sequencing results in <24 hours. Reduced capital and maintenance costs and lower-throughput capabilities also give the iSeq100 an advantage over MiSeq in settings of individualized care but not in high-throughput settings such as reference laboratories, where sample batching can be optimized to minimize cost at the expense of workflow complexity and time.


Subject(s)
Drug Resistance, Multiple, Bacterial/genetics , High-Throughput Nucleotide Sequencing , Mycobacterium tuberculosis/genetics , Sequence Analysis, DNA , Tuberculosis, Multidrug-Resistant/microbiology , Cost-Benefit Analysis , DNA, Bacterial/analysis , High-Throughput Nucleotide Sequencing/economics , High-Throughput Nucleotide Sequencing/instrumentation , High-Throughput Nucleotide Sequencing/methods , Humans , Reproducibility of Results , Sequence Analysis, DNA/economics , Sequence Analysis, DNA/instrumentation , Sequence Analysis, DNA/methods , Time Factors
18.
Am J Hum Genet ; 103(5): 691-706, 2018 11 01.
Article in English | MEDLINE | ID: mdl-30388399

ABSTRACT

C-reactive protein (CRP) is a sensitive biomarker of chronic low-grade inflammation and is associated with multiple complex diseases. The genetic determinants of chronic inflammation remain largely unknown, and the causal role of CRP in several clinical outcomes is debated. We performed two genome-wide association studies (GWASs), on HapMap and 1000 Genomes imputed data, of circulating amounts of CRP by using data from 88 studies comprising 204,402 European individuals. Additionally, we performed in silico functional analyses and Mendelian randomization analyses with several clinical outcomes. The GWAS meta-analyses of CRP revealed 58 distinct genetic loci (p < 5 × 10-8). After adjustment for body mass index in the regression analysis, the associations at all except three loci remained. The lead variants at the distinct loci explained up to 7.0% of the variance in circulating amounts of CRP. We identified 66 gene sets that were organized in two substantially correlated clusters, one mainly composed of immune pathways and the other characterized by metabolic pathways in the liver. Mendelian randomization analyses revealed a causal protective effect of CRP on schizophrenia and a risk-increasing effect on bipolar disorder. Our findings provide further insights into the biology of inflammation and could lead to interventions for treating inflammation and its clinical consequences.


Subject(s)
Genetic Loci/genetics , Inflammation/genetics , Metabolic Networks and Pathways/genetics , Adolescent , Adult , Aged , Aged, 80 and over , Biomarkers/metabolism , Bipolar Disorder/genetics , Bipolar Disorder/metabolism , Body Mass Index , C-Reactive Protein/genetics , Child , Female , Genome-Wide Association Study/methods , Humans , Inflammation/metabolism , Liver/metabolism , Liver/pathology , Male , Mendelian Randomization Analysis/methods , Middle Aged , Schizophrenia/genetics , Schizophrenia/metabolism , Young Adult
19.
Nat Commun ; 9(1): 4228, 2018 10 12.
Article in English | MEDLINE | ID: mdl-30315176

ABSTRACT

Elevated serum urate levels can cause gout, an excruciating disease with suboptimal treatment. Previous GWAS identified common variants with modest effects on serum urate. Here we report large-scale whole-exome sequencing association studies of serum urate and kidney function among ≤19,517 European ancestry and African-American individuals. We identify aggregate associations of low-frequency damaging variants in the urate transporters SLC22A12 (URAT1; p = 1.3 × 10-56) and SLC2A9 (p = 4.5 × 10-7). Gout risk in rare SLC22A12 variant carriers is halved (OR = 0.5, p = 4.9 × 10-3). Selected rare variants in SLC22A12 are validated in transport studies, confirming three as loss-of-function (R325W, R405C, and T467M) and illustrating the therapeutic potential of the new URAT1-blocker lesinurad. In SLC2A9, mapping of rare variants of large effects onto the predicted protein structure reveals new residues that may affect urate binding. These findings provide new insights into the genetic architecture of serum urate, and highlight molecular targets in SLC22A12 and SLC2A9 for lowering serum urate and preventing gout.


Subject(s)
Exome/genetics , Uric Acid/blood , Genetic Predisposition to Disease , Glucose Transport Proteins, Facilitative/chemistry , Glucose Transport Proteins, Facilitative/genetics , Glucose Transport Proteins, Facilitative/metabolism , Humans , Kidney Function Tests , Meta-Analysis as Topic , Organic Anion Transporters/chemistry , Organic Anion Transporters/genetics , Organic Anion Transporters/metabolism , Organic Cation Transport Proteins/chemistry , Organic Cation Transport Proteins/genetics , Organic Cation Transport Proteins/metabolism , Protein Structure, Secondary
20.
Methods Mol Biol ; 1793: 231-258, 2018.
Article in English | MEDLINE | ID: mdl-29876900

ABSTRACT

Differences between genomes can be due to single nucleotide variants (SNPs), translocations, inversions and copy number variants (CNVs, gain or loss of DNA). The latter can range from sub-microscopic events to complete chromosomal aneuploidies. Small CNVs are often benign but those larger than 250 kb are strongly associated with morbid consequences such as developmental disorders and cancer. Detecting CNVs within and between populations is essential to better understand the plasticity of our genome and to elucidate its possible contribution to disease or phenotypic traits.While the link between SNPs and disease susceptibility has been well studied, to date there are still very few published CNV genome-wide association studies; probably owing to the fact that CNV analysis remains a slightly more complex task than SNP analysis (both in term of bioinformatics workflow and uncertainty in the CNV calling leading to high false positive rates and unknown false negative rates). This chapter aims at explaining computational methods for the analysis of CNVs, ranging from study design, data processing and quality control, up to genome-wide association study with clinical traits.


Subject(s)
DNA Copy Number Variations , Genetic Predisposition to Disease , Genome-Wide Association Study , Computational Biology/methods , Genome-Wide Association Study/methods , Genomics/methods , Humans , Workflow
SELECTION OF CITATIONS
SEARCH DETAIL
...