1.
Dent Mater ; 35(11): 1644-1653, 2019 11.
Article in English | MEDLINE | ID: mdl-31575489

ABSTRACT

OBJECTIVE: To evaluate the influence of extrinsic pigmentation on the biaxial flexural strength and surface topographic of translucent Y-TZP (InCoris TZI - Sirona - USA) subjected to several surface treatments. METHODS: Sintered zirconia discs-shaped specimens (n=120) (ø:12mm; thickness:1.2mm; ISO 6872) were prepared and divided (n=15) according to various factors: "extrinsic pigmentation" (n: without; p: with) and "surface treatments" (C: control - as sintered; A: abraded with silica-coated alumina particles (30µm); G: glazed with a thin film of low-fusing porcelain glaze; GH: glazed and etched with 10% hydrofluoridric acid for 60s. Mechanical cycling (1.2×106 cycles, 200N, 3.8Hz) and flexural strength test (1mm/min - 1000kg cell) were performed. Two-way ANOVA and Tukey's were used for statistical test (α=0.05). Weibull analysis was used to evaluate the strength reliability. Samples were analyzed via (1) an optical profilometer to determine the surface roughness (Ra); (2) an X-ray diffraction (XRD) to evaluate phase transformations; and (3) a SEM equipped with an energy dispersive X-ray spectroscopy (EDX) to elucidate morphological properties and chemical compositions. RESULTS: Regardless of the surface treatment (p=0.5459) (Cn: 560.16MPa; Gn: 573.36MPa; An: 643.51MPa; GHn: 542.94MPa; Cp: 628.04MPa; Gp: 641.90MPa; Ap: 554.47MPa; GHp :602.84MPa) and extrinsic pigmentation (p=0.1280) there was no difference in the flexural strength among the experimental groups. According to the XRD analysis, phase transformations occurred in the An group (t→m) and in Ap group (t→c). Surface roughness was affected by surface treatments (An - p=0.001) and extrinsic pigmentation (Gp - p=0.001). SIGNIFICANCE: The biaxial flexural strength of the tested samples was not affected neither by surface treatments nor by pigmentation, although it can cause phase transformation and promote surface roughness.


Subject(s)
Flexural Strength , Zirconium , Ceramics , Materials Testing , Pigmentation , Reproducibility of Results , Stress, Mechanical , Surface Properties , Yttrium
2.
J Biomed Mater Res B Appl Biomater ; 105(7): 1972-1977, 2017 10.
Article in English | MEDLINE | ID: mdl-27312806

ABSTRACT

OBJECTIVES: This study evaluated the influence of two aging procedures on the biaxial flexural strength of yttria-stabilized tetragonal zirconia ceramics. MATERIAL AND METHODS: Disc-shaped zirconia specimens and (ZE: E.max ZirCAD, Ivoclar; ZT: Zirkon Translucent, Zirkonzahn) (N = 80) (∅:12 mm; thickness:1.2 mm, ISO 6872) were prepared and randomly divided into four groups (n = 10 per group) according to the aging procedures: C: Control, no aging; M: mechanical cycling (2 × 106 cycles/3.8 Hz/200 N); AUT: Aging in autoclave at 134°C, 2 bar for 24 h; AUT + M: Autoclave aging followed by mechanical cycling. After aging, the transformed monoclinic zirconia (%) were evaluated using X-ray diffraction and surface roughness was measured using atomic force microscopy. The average grain size was measured by scanning electron microscopy and the specimens were submitted to biaxial flexural strength testing (1 mm/min, 1000 kgf in water). Data (MPa) were statistically analyzed using 2-way analysis of variance and Tukey's test (α = 0.05). RESULTS: Aging procedures significantly affected (p = 0.000) the flexural strength data but the effect of zirconia type was not significant (p = 0.657). AUTZT (936.4 ± 120.9b ) and AUT + MZE (867.2 ± 49.3b ) groups presented significantly higher values (p < 0.05) of flexural strength than those of the control groups (CZT : 716.5 ± 185.7a ; CZE : 779.9 ± 114a ) (Tukey's test). The monoclinic phase percentage (%) was higher for AUTZE (71), AUTZT (66), AUT + MZE (71), and AUT + MZM (66) compared to the C groups (ZE:0; ZT:0). Surface roughness (µm) was higher for AUTZE (0.09), AUTZT (0.08), AUT + MZE (0.09 µm), and AUT + MZT (0.09 µm) than those of other groups. CONCLUSIONS: Regardless of the zirconia type, autoclave aging alone or with mechanical aging increased the flexure strength but also induced higher transformation from tetragonal to monoclinic phase in both zirconia materials tested. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1972-1977, 2017.


Subject(s)
Ceramics/chemistry , Stress, Mechanical , Zirconium/chemistry , Hot Temperature , Pressure
3.
Clin Oral Investig ; 20(3): 503-11, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26224513

ABSTRACT

OBJECTIVES: The aim of this study was to analyze the capacity of a new modified laser surface to stimulate calvarial osteoblasts isolated from neonatal mouse bones to differentiate and form mineralized nodules. METHODS: Titanium discs were subjectezd or not to laser irradiation according to specific parameters and characterized. Osteoblasts isolated from neonatal mouse calvaria were cultured over the discs, and the capacity of these cells to proliferate (MTT assay), form mineralized nodules (Alizarin red assay), and enhance alkaline phosphatase activity (ALPase activity) was analyzed. Real-time PCR was used for quantification of gene expression. RESULTS: Laser-irradiated titanium discs (L) presented a rough nano-to-micrometric oxidized surface contrasting with the smooth pattern on polished discs (P). The Ra on the micrometric level increased from 0.32 ± 0.01 µm on P surfaces to 10.57 ± 0.39 µm on L surfaces. When compared with P, L promoted changes in osteoblast morphology, increased mineralized nodule formation in osteoblasts cultured on the surfaces for 14 days, and enhanced ALPase activity at days 7 and 14. Transcription factors triggering osteoblast differentiation (Runx2 and Sp7) and genes encoding the bone extracellular matrix proteins collagen type-1 (Col1a1), osteopontin (Spp1), and osteocalcin (Bglap) were upregulated in cells on L surfaces compared with those on P surfaces at days 1-14. CONCLUSION: Laser treatment of titanium surfaces created a rough surface that stimulated osteoblast differentiation. CLINICAL RELEVANCE: Laser treatment of titanium generates a reproducible and efficient surface triggering osteoblast differentiation that can be of importance for osteointegration.


Subject(s)
Cell Differentiation/physiology , Lasers, Solid-State , Osteoblasts/physiology , Skull/cytology , Titanium/chemistry , Animals , Mice , Mice, Inbred C57BL , Microscopy, Electron, Scanning , Osseointegration/radiation effects , Real-Time Polymerase Chain Reaction , Spectrometry, X-Ray Emission , Surface Properties
4.
Bioessays ; 37(11): 1236-42, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26335701

ABSTRACT

NIK1 is a receptor-like kinase involved in plant antiviral immunity. Although NIK1 is structurally similar to the plant immune factor BAK1, which is a key regulator in plant immunity to bacterial pathogens, the NIK1-mediated defenses do not resemble BAK1 signaling cascades. The underlying mechanism for NIK1 antiviral immunity has recently been uncovered. NIK1 activation mediates the translocation of RPL10 to the nucleus, where it interacts with LIMYB to fully down-regulate translational machinery genes, resulting in translation inhibition of host and viral mRNAs and enhanced tolerance to begomovirus. Therefore, the NIK1 antiviral immunity response culminates in global translation suppression, which represents a new paradigm for plant antiviral defenses. Interestingly, transcriptomic analyses in nik1 mutant suggest that NIK1 may suppress antibacterial immune responses, indicating a possible opposite effect of NIK1 in bacterial and viral infections.


Subject(s)
Arabidopsis Proteins/immunology , Arabidopsis/immunology , Arabidopsis/virology , Begomovirus/immunology , Plant Immunity/immunology , Protein Serine-Threonine Kinases/immunology , Solanum lycopersicum/immunology , Solanum lycopersicum/virology , Phosphorylation , Protein Biosynthesis/genetics , Protein Transport/immunology , Ribosomal Protein L10 , Ribosomal Proteins/metabolism , Signal Transduction , Glycine max/immunology , Glycine max/virology
5.
Dent Mater ; 30(12): e396-404, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25244926

ABSTRACT

OBJECTIVE: To determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP) METHODS: Sixty disc-shaped specimens (∅, 12mm; thickness, 1.6mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n=10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8Hz/200N); (T) thermal cycling (6,000 cycles/5-55°C/30s); (TM) thermomechanical cycling (1,200,000 cycles/3.8Hz/200N with temperature range from 5°C to 55°C for 60s each); (AUT) 12h in autoclave at 134°C/2bars; and (STO) storage in distilled water (37°C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1mm/min, load 100kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (α=0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal-Wallis and Dunn's tests. RESULTS: ANOVA revealed that flexural strength was affected by the aging procedures (p=0.002). The M (781.6MPa) and TM (771.3MPa) groups presented lower values of flexural strength than did C (955MPa), AUT (955.8MPa), T (960.8MPa) and STO (910.4MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal-Wallis test, p=0.004). In addition, the surface roughnesses were similar among the groups (p=0.165). SIGNIFICANCE: Water storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling.


Subject(s)
Ceramics/chemistry , Dental Materials/chemistry , Yttrium/chemistry , Zirconium/chemistry , Algorithms , Crystallography , Imaging, Three-Dimensional/methods , Materials Testing , Pliability , Random Allocation , Stress, Mechanical , Surface Properties , Temperature , Time Factors , Water/chemistry , X-Ray Diffraction
6.
Acta Odontol Scand ; 72(5): 346-53, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24175663

ABSTRACT

OBJECTIVES: This study evaluated the influence of air-particle abrasion protocols on the surface roughness (SR) of zirconia and the shear bond strength (SBS) of dual-polymerized resin cement to this ceramic. MATERIALS AND METHODS: Sintered zirconia blocks (n = 115) (Lava, 3M ESPE) were embedded in acrylic resin and polished. The specimens were divided according to the 'particle type' (Al: 110 µm Al2O3; Si: 110 µm SiO2) and 'pressure' factors (2.5 or 3.5 bar) (n = 3 per group): (a) Control (no air-abrasion); (b) Al2.5; (c) Si2.5; (d) Al3.5; (e) Si3.5. SR (Ra) was measured 3-times from each specimen after 20 s of air-abrasion (distance: 10 mm) using a digital optical profilometer. Surface topography was evaluated under SEM analyses. For the SBS test, 'particle type', 'pressure' and 'thermocycling' (TC) factors were considered (n = 10; n = 10 per group): Control (no air-abrasion); Al2.5; Si2.5; Al3.5; Si3.5; ControlTC; Al2.5TC; Si2.5TC; Al3.5TC; Si3.5TC. After silane application, resin cement (Panavia F2.0) was bonded and polymerized. Specimens were thermocycled (6.000 cycles, 5-55°C) and subjected to SBS (1 mm/min). Data were analyzed using ANOVA, Tukey's and Dunnett tests (5%). RESULTS: 'Particle' (p = 0.0001) and 'pressure' (p = 0.0001) factors significantly affected the SR. All protocols significantly increased the SR (Al2.5: 0.45 ± 0.02; Si2.5: 0.39 ± 0.01; Al3.5: 0.80 ± 0.01; Si3.5: 0.64 ± 0.01 µm) compared to the control group (0.16 ± 0.01 µm). For SBS, only 'particle' factor significantly affected the results (p = 0.015). The SiO2 groups presented significantly higher SBS results than Al2O3 (Al2.5: 4.78 ± 1.86; Si2.5: 7.17 ± 2.62; Al3.5: 4.97 ± 3.74; Si3.5: 9.14 ± 4.09 MPa) and the control group (3.67 ± 3.0 MPa). All TC specimens presented spontaneous debondings. SEM analysis showed that Al2O3 created damage in zirconia in the form of grooves, different from those observed with SiO2 groups. CONCLUSIONS: Air-abrasion with 110 µm Al2O3 resulted in higher roughness, but air-abrasion protocols with SiO2 promoted better adhesion.


Subject(s)
Air Abrasion, Dental , Resin Cements , Zirconium/chemistry , Materials Testing , Microscopy, Electron, Scanning , Surface Properties
7.
J Mech Behav Biomed Mater ; 26: 155-63, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23746698

ABSTRACT

This study evaluated the effect of different air-particle abrasion protocols on the biaxial flexural strength and structural stability of zirconia ceramics. Zirconia ceramic specimens (ISO 6872) (Lava, 3M ESPE) were obtained (N=336). The specimens (N=118, n=20 per group) were randomly assigned to one of the air-abrasion protocols: Gr1: Control (as-sintered); Gr2: 50 µm Al2O3 (2.5 bar); Gr3: 50 µm Al2O3 (3.5 bar); Gr4: 110 µm Al2O3(2.5 bar); Gr5: 110 µm Al2O3 (3.5 bar); Gr6: 30 µm SiO2 (2.5 bar) (CoJet); Gr7: 30 µm SiO2(3.5 bar); Gr8: 110 µm SiO2 (2.5 bar) (Rocatec Plus); and Gr9: 110 µm SiO2 (3.5 bar) (duration: 20 s, distance: 10 mm). While half of the specimens were tested immediately, the other half was subjected to cyclic loading in water (100,000 cycles; 50 N, 4 Hz, 37 °°C) prior to biaxial flexural strength test (ISO 6872). Phase transformation (t→m), relative amount of transformed monoclinic zirconia (FM), transformed zone depth (TZD) and surface roughness were measured. Particle type (p=0.2746), pressure (p=0.5084) and cyclic loading (p=0.1610) did not influence the flexural strength. Except for the air-abraded group with 110 µm Al2O3 at 3.5 bar, all air-abrasion protocols increased the biaxial flexural strength (MPa) (Controlnon-aged: 1,030 ± 153, Controlaged: 1,138 ± 138; Experimentalnon-aged: 1,307 ± 184-1,554 ± 124; Experimentalaged: 1,308 ± 118-1,451 ± 135) in both non-aged and aged conditions, respectively. Surface roughness (Ra) was the highest with 110 µm Al2O3(0.84 µm. FM values ranged from 0% to 27.21%, higher value for the Rocatec Plus (110 µm SiO2) and 110 µm Al2O3 groups at 3.5 bar pressure. TZD ranged between 0 and 1.43 µm, with the highest values for Rocatec Plus and 110 µm Al2O3 groups at 3.5 bar pressure.


Subject(s)
Air , Ceramics/chemistry , Mechanical Phenomena , Phase Transition , Zirconium/chemistry , Hot Temperature , Pressure , Surface Properties
8.
J Mech Behav Biomed Mater ; 20: 19-28, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23455160

ABSTRACT

This study evaluated the effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading. Disc-shaped zirconia specimens (Ø: 15mm, thickness: 1.2mm) (N=32) were submitted to one of the air-particle abrasion protocols (n=8 per group): (a) 50µm Al2O3 particles, (b) 110µm Al2O3 particles coated with silica (Rocatec Plus), (c) 30µm Al2O3 particles coated with silica (CoJet Sand) for 20s at 2.8bar pressure. Control group received no air-abrasion. All specimens were initially cyclic loaded (×20,000, 50N, 1Hz) in water at 37°C and then subjected to biaxial flexural strength testing where the conditioned surface was under tension. Zirconia surfaces were characterized and roughness was measured with 3D surface profilometer. Phase transformation from tetragonal to monoclinic was determined by Raman spectroscopy. The relative amount of transformed monoclinic zirconia (FM) and transformed zone depth (TZD) were measured using XRD. The data (MPa) were analyzed using ANOVA, Tukey's tests and Weibull modulus (m) were calculated for each group (95% CI). The biaxial flexural strength (MPa) of CoJet treated group (1266.3±158(A)) was not significantly different than that of Rocatec Plus group (1179±216.4(A,B)) but was significantly higher than the other groups (Control: 942.3±74.6(C); 50µm Al2O3: 915.2±185.7(B,C)). Weibull modulus was higher for control (m=13.79) than those of other groups (m=4.95, m=5.64, m=9.13 for group a, b and c, respectively). Surface roughness (Ra) was the highest with 50µm Al2O3 (0.261µm) than those of other groups (0.15-0.195µm). After all air-abrasion protocols, FM increased (15.02%-19.25%) compared to control group (11.12%). TZD also showed increase after air-abrasion protocols (0.83-1.07µm) compared to control group (0.59µm). Air-abrasion protocols increased the roughness and monoclinic phase but in turn abrasion with 30µm Al2O3 particles coated with silica has increased the biaxial flexural strength of the tested zirconia.


Subject(s)
Dental Etching/methods , Dental Materials/chemistry , Silicon Dioxide/chemistry , Zirconium/chemistry , Air , Dental Stress Analysis/methods , Elastic Modulus , Hardness , Materials Testing , Phase Transition , Stress, Mechanical , Surface Properties , Tensile Strength
SELECTION OF CITATIONS