Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Article in English | MEDLINE | ID: mdl-38115695

ABSTRACT

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Magnetic Resonance Imaging/methods , Software , Algorithms
2.
World J Biol Psychiatry ; 24(5): 414-428, 2023 06.
Article in English | MEDLINE | ID: mdl-36102141

ABSTRACT

OBJECTIVES: Pilot study validating the animal model of depression - the bilateral olfactory bulbectomy in rats - by two nuclear magnetic resonance methods, indirectly detecting the metabolic state of the brain. Furthermore, the study focussed on potential differences in brain laterality. METHODS: Arterial spin labelling assessed cerebral brain flow in prefrontal, sensorimotor, and piriform cortices, nucleus accumbens, hippocampus, thalamus, circle of Willis, and whole brain. Proton magnetic resonance spectroscopy provided information about relative metabolite concentrations in the cortex and hippocampus. RESULTS: Arterial spin labelling found no differences in cerebral perfusion in the group comparison but revealed lateralisation in the thalamus of the control group and the sensorimotor cortex of the bulbectomized rats. Lower Cho/tCr and Cho/NAA levels were found in the right hippocampus in bulbectomized rats. The differences in lateralisation were shown in the hippocampus: mI/tCr in the control group, Cho/NAA, NAA/tCr, Tau/tCr in the model group, and in the cortex: NAA/tCr, mI/tCr in the control group. CONCLUSION: Olfactory bulbectomy affects the neuronal and biochemical profile of the rat brain laterally and, as a model of depression, was validated by two nuclear magnetic resonance methods.


Subject(s)
Brain , Magnetic Resonance Imaging , Rats , Animals , Pilot Projects , Magnetic Resonance Spectroscopy/methods , Brain/pathology , Receptors, Antigen, T-Cell/metabolism , Choline/metabolism , Creatine/metabolism , Aspartic Acid/metabolism
3.
Magn Reson Imaging ; 77: 204-212, 2021 04.
Article in English | MEDLINE | ID: mdl-33359424

ABSTRACT

The temporomandibular joint (TMJ) is typically involved in 45-87% of children with Juvenile Idiopathic Arthritis (JIA). Accurate diagnosis of JIA is difficult as various clinical tests, including MRI, disagree. The purpose of this study is to optimize the methodological aspects of Dynamic Contrast Enhanced (DCE) MRI of the TMJ in children. In this cross-sectional study, including data from 73 JIA affected children, aged 6-15 years, effects of motion correction, sampling rate and parametric modelling on DCE-MRI data is investigated. Consensus among three radiologists determined the regions of interest. Quantitative perfusion parameters were estimated using four perfusion models; the Adiabatic Approximation to Tissue Homogeneity (AATH), Distributed Capillary Adiabatic Tissue Homogeneity (DCATH), Gamma Capillary Transit Time (GCTT) and Two Compartment Exchange (2CXM) models. Effects of motion correction were evaluated by a sum of least squares between corrected raw data and the GCTT model. The effect of systematically down sampling the raw data was tested. The sum of least squares was computed across all pharmacokinetic models. Relative difference perfusion parameters between the left and right TMJ were used for an unsupervised k-means based stratification of the data based on a principal component analysis, as well as for a supervised random forest classification. Diagnostic sensitivity and specificity were computed relative to structural image scorings. Paired sample t-tests, as well as ANOVA tests, were used (significant threshold: p < 0.05) with Tukeys post hoc test. High-level elastic motion correction provides the best least square fit to the GCTT model (percental improvement: 72-84%). A 4 s sampling rate captures more of the potentially disease relevant signal variations. The various parametric models all leave comparable residues (relative standard deviation: 3.4%). In further evaluation of DCE-MRI as a potential diagnostic tool for JIA a high-level elastic motion correction scheme should be adopted, with a sampling rate of at least 4 s. Results suggest that DCE-MRI data can be a valuable part in JIA diagnostics in the TMJ.


Subject(s)
Arthritis, Juvenile/diagnostic imaging , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Models, Statistical , Movement , Temporomandibular Joint/diagnostic imaging , Adolescent , Artifacts , Child , Child, Preschool , Cross-Sectional Studies , Female , Humans , Male , Sensitivity and Specificity
4.
Magn Reson Imaging ; 62: 46-56, 2019 10.
Article in English | MEDLINE | ID: mdl-31150814

ABSTRACT

PURPOSE: One of the main obstacles for reliable quantitative dynamic contrast-enhanced (DCE) MRI is the need for accurate knowledge of the arterial input function (AIF). This is a special challenge for preclinical small animal applications where it is very difficult to measure the AIF without partial volume and flow artifacts. Furthermore, using advanced pharmacokinetic models (allowing estimation of blood flow and permeability-surface area product in addition to the classical perfusion parameters) poses stricter requirements on the accuracy and precision of AIF estimation. This paper addresses small animal DCE-MRI with advanced pharmacokinetic models and presents a method for estimation of the AIF based on blind deconvolution. METHODS: A parametric AIF model designed for small animal physiology and use of advanced pharmacokinetic models is proposed. The parameters of the AIF are estimated using multichannel blind deconvolution. RESULTS: Evaluation on simulated data show that for realistic signal to noise ratios blind deconvolution AIF estimation leads to comparable results as the use of the true AIF. Evaluation on real data based on DCE-MRI with two contrast agents of different molecular weights showed a consistence with the known effects of the molecular weight. CONCLUSION: Multi-channel blind deconvolution using the proposed AIF model specific for small animal DCE-MRI provides reliable perfusion parameter estimates under realistic signal to noise conditions.


Subject(s)
Arteries/diagnostic imaging , Contrast Media/pharmacokinetics , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Algorithms , Animals , Computer Simulation , Humans , Mice , Mice, Inbred BALB C , Necrosis/pathology , Perfusion , Pharmacokinetics , Regression Analysis , Reproducibility of Results , Signal-To-Noise Ratio
5.
Article in English | MEDLINE | ID: mdl-25570937

ABSTRACT

This paper is focused on quantitative perfusion analysis using MRI and ultrasound. In both MRI and ultrasound, most approaches allow estimation of rate constants (Ktrans, kep for MRI) and indices (AUC, TTP) that are only related to the physiological perfusion parameters of a tissue (e.g. blood flow, vessel permeability) but do not allow their absolute quantification. Recent methods for quantification of these physiological perfusion parameters are shortly reviewed. The main problem of these methods is estimation of the arterial input function (AIF). This paper summarizes and extends the current blind-deconvolution approaches to AIF estimation. The feasibility of these methods is shown on a small preclinical study using both MRI and ultrasound.


Subject(s)
Contrast Media/pharmacokinetics , Gadolinium DTPA/pharmacokinetics , Animals , Cell Line, Tumor , Humans , Magnetic Resonance Imaging/methods , Mice, Inbred BALB C , Neoplasm Transplantation , Neoplasms, Experimental/diagnostic imaging , Neoplasms, Experimental/metabolism , Tissue Distribution , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...