Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Integr Org Biol ; 6(1): obae009, 2024.
Article in English | MEDLINE | ID: mdl-38699511

ABSTRACT

High-resolution imaging, 3D modeling, and quantitative analyses are equipping evolutionary biologists with new approaches to understanding the variation and evolution of the musculoskeletal system. However, challenges with interpreting DiceCT data and higher order use of modeled muscles have not yet been fully explored, and the error in and accuracy of some digital methods remain unclear. West Indian Anolis lizards are a model clade for exploring patterns in functional adaptation, ecomorphology, and sexual size dimorphism in vertebrates. These lizards possess numerous jaw muscles with potentially different anatomies that sculpt the adductor chamber of the skull. Here we test approaches to quantifying the musculoskeletal shape of the heads of two species of Anolis: A. pulchellus and A. sagrei. We employ comparative approaches such as DiceCT segmentation of jaw muscles, 3D surface attachment mapping, and 3D landmarking with the aim of exploring muscle volumes, 3D muscle fiber architecture, and sexual dimorphism of the skull. We then compare sources of measurement error in these 3D analyses while also presenting new 3D musculoskeletal data from the Anolis feeding apparatus. These findings demonstrate the accessibility and repeatability of these emerging techniques as well as provide details regarding the musculoskeletal anatomy of the heads of A. pulchellus and A. sagrei which show potential for further research of comparative biomechanics and evolution in the clade.

2.
Ann Plast Surg ; 5(3): 205-11, 1980 Sep.
Article in English | MEDLINE | ID: mdl-7447289

ABSTRACT

Clearance of intradermally injected xenon 133 was used to measure blood flow in distant flaps in humans with the donor pedicle temporarily clamped just prior to division. All 18 flaps with a blood flow of 0.5 ml per 100 gm of tissue per minute or more survived completely after separation. Of 7 with lesser flow, 3 underwent marginal necrosis adjacent to the line of division and 4 survived entirely. The false-negative result (complete flap survival in 4 patients) was artifactual due to isotope injection too close to the clamp, reflecting increased local tissue tension caused by the clamp rather than low blood flow in the flap. Xenon 133 washout does permit quantitative evaluation of blood flow, and since it is a clean isotope, it appears superior to sodium 24 and technetium 99m, which have been used in a similar manner. The test is proposed as an adjunct to clinical judgment in timing pedicle division.


Subject(s)
Surgical Flaps , Xenon Radioisotopes , Humans , Regional Blood Flow , Skin/blood supply , Sodium Radioisotopes , Technetium
SELECTION OF CITATIONS
SEARCH DETAIL
...