Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Cancer Res ; 30(8): 1518-1529, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38493804

ABSTRACT

PURPOSE: The current approach for molecular subtyping of colon cancer relies on gene expression profiling, which is invasive and has limited ability to reveal dynamics and spatial heterogeneity. Molecular imaging techniques, such as PET, present a noninvasive alternative for visualizing biological information from tumors. However, the factors influencing PET imaging phenotype, the suitable PET radiotracers for differentiating tumor subtypes, and the relationship between PET phenotypes and tumor genotype or gene expression-based subtyping remain unknown. EXPERIMENTAL DESIGN: In this study, we conducted 126 PET scans using four different metabolic PET tracers, [18F]fluorodeoxy-D-glucose ([18F]FDG), O-(2-[18F]fluoroethyl)-l-tyrosine ([18F]FET), 3'-deoxy-3'-[18F]fluorothymidine ([18F]FLT), and [11C]acetate ([11C]ACE), using a spectrum of five preclinical colon cancer models with varying genetics (BMT, AKPN, AK, AKPT, KPN), at three sites (subcutaneous, orthograft, autochthonous) and at two tumor stages (primary vs. metastatic). RESULTS: The results demonstrate that imaging signatures are influenced by genotype, tumor environment, and stage. PET imaging signatures exhibited significant heterogeneity, with each cancer model displaying distinct radiotracer profiles. Oncogenic Kras and Apc loss showed the most distinctive imaging features, with [18F]FLT and [18F]FET being particularly effective, respectively. The tissue environment notably impacted [18F]FDG uptake, and in a metastatic model, [18F]FET demonstrated higher uptake. CONCLUSIONS: By examining factors contributing to PET-imaging phenotype, this study establishes the feasibility of noninvasive molecular stratification using multiplex radiotracer PET. It lays the foundation for further exploration of PET-based subtyping in human cancer, thereby facilitating noninvasive molecular diagnosis.


Subject(s)
Colonic Neoplasms , Fluorodeoxyglucose F18 , Humans , Dideoxynucleosides , Positron-Emission Tomography/methods , Colonic Neoplasms/diagnostic imaging , Colonic Neoplasms/genetics , Radiopharmaceuticals
2.
Cancer Metab ; 11(1): 14, 2023 Sep 07.
Article in English | MEDLINE | ID: mdl-37679822

ABSTRACT

BACKGROUND: Tissue environment is critical in determining tumour metabolic vulnerability. However, in vivo drug testing is slow and waiting for tumour growth delay may not be the most appropriate endpoint for metabolic treatments. An in vivo method for measuring energy stress would rapidly determine tumour targeting in a physiologically relevant environment. The sodium-iodide symporter (NIS) is an imaging reporter gene whose protein product co-transports sodium and iodide, and positron emission tomography (PET) radiolabelled anions into the cell. Here, we show that PET imaging of NIS-mediated radiotracer uptake can rapidly visualise tumour energy stress within minutes following in vivo treatment. METHODS: We modified HEK293T human embryonic kidney cells, and A549 and H358 lung cancer cells to express transgenic NIS. Next, we subjected these cells and implanted tumours to drugs known to induce metabolic stress to observe the impact on NIS activity and energy charge. We used [18F]tetrafluoroborate positron emission tomography (PET) imaging to non-invasively image NIS activity in vivo. RESULTS: NIS activity was ablated by treating HEK293T cells in vitro, with the Na+/K+ ATPase inhibitor digoxin, confirming that radiotracer uptake was dependent on the sodium-potassium concentration gradient. NIS-mediated radiotracer uptake was significantly reduced (- 58.2%) following disruptions to ATP re-synthesis by combined glycolysis and oxidative phosphorylation inhibition in HEK293T cells and by oxidative phosphorylation inhibition (- 16.6%) in A549 cells in vitro. PET signal was significantly decreased (- 56.5%) within 90 min from the onset of treatment with IACS-010759, an oxidative phosphorylation inhibitor, in subcutaneous transgenic A549 tumours in vivo, showing that NIS could rapidly and sensitively detect energy stress non-invasively, before more widespread changes to phosphorylated AMP-activated protein kinase, phosphorylated pyruvate dehydrogenase, and GLUT1 were detectable. CONCLUSIONS: NIS acts as a rapid metabolic sensor for drugs that lead to ATP depletion. PET imaging of NIS could facilitate in vivo testing of treatments targeting energetic pathways, determine drug potency, and expedite metabolic drug development.

3.
EJNMMI Radiopharm Chem ; 7(1): 32, 2022 Dec 13.
Article in English | MEDLINE | ID: mdl-36512196

ABSTRACT

BACKGROUND: Sodium iodide symporter (NIS) imaging by positron emission tomography (PET) is gaining traction in nuclear medicine, with an increasing number of human studies being published using fluorine-18 radiolabelled tetrafluoroborate ([18F]TFB). Clinical success of any radiotracer relies heavily on its accessibility, which in turn depends on the availability of robust radiolabelling procedures providing a radiotracer in large quantities and of high radiopharmaceutical quality. RESULTS: Here we publish an improved radiolabelling method and quality control procedures for high molar activity [18F]TFB. The use of ammonium hydroxide for [18F]fluoride elution, commercially available boron trifluoride-methanol complex dissolved in acetonitrile as precursor and removal of unreacted [18F]fluoride on Florisil solid-phase extraction cartridges resulted in the reliable production of [18F]TFB on SYNTHRA and TRACERLAB FXFN automated synthesizers with radiochemical yields in excess of 30%, radiochemical purities in excess of 98% and molar activities in the range of 34-217 GBq/µmol at the end of synthesis. PET scanning of a mouse lung tumour model carrying a NIS reporter gene rendered images of high quality and improved sensitivity. CONCLUSIONS: A novel automated radiosynthesis procedure for [18F]tetrafluoroborate has been developed that provides the radiotracer with high molar activity, suitable for preclinical imaging of NIS reporter gene.

SELECTION OF CITATIONS
SEARCH DETAIL
...