Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Circulation ; 109(14): 1735-40, 2004 Apr 13.
Article in English | MEDLINE | ID: mdl-15066954

ABSTRACT

BACKGROUND: Distal embolization of plaque particulate liberated during stenting may cause periprocedural complications. The number, size, and volume of debris released during stenting, however, have not been quantified, rendering embolic protection approaches empiric. We used a novel method of microparticle size assessment to measure volume and characterize individual sizes of particles captured by the PercuSurge GuardWire balloon or a vascular filter during saphenous vein graft stenting. METHODS AND RESULTS: Braided nitinol filters (average distal pore size 100 microns) were used in 47 saphenous vein grafts in 44 patients. The PercuSurge GuardWire was used in 17 saphenous vein grafts in 16 patients. Particulate debris was subjected to microparticle size analysis (RapidVue, Beckman Coulter). All samples contained particulate debris. For both filter and GuardWire populations, most particles were <100 microm in longest dimension (87% and 90% of particles, respectively), and the distribution of particle sizes was identical. Total embolic load per lesion for both filters and GuardWire aspirates was also similar: median embolic load per filter was 16 mm3 (range 2 to 84 mm3). Median embolic load per GuardWire was also 16 mm3 (range 7 to 42 mm3). Histopathologic analysis demonstrated that most samples contained plaque elements and platelet-rich thrombus. CONCLUSIONS: During saphenous vein graft interventions, particulate retrieved with a vascular filtering device or an occlusion balloon was similar in amount and character. This supports the notion that unless soluble mediators play an important role in adverse acute clinical events after stenting, the clinical efficacy of filtering devices may be equal to that of occlusion devices.


Subject(s)
Catheterization , Coronary Artery Bypass/methods , Coronary Artery Disease/surgery , Embolism/prevention & control , Filtration , Intraoperative Complications/prevention & control , Stents , Alloys , Calibration , Coronary Artery Bypass/instrumentation , Coronary Artery Disease/pathology , Embolism/etiology , Equipment Design , Filtration/instrumentation , Foam Cells/ultrastructure , Humans , Intraoperative Complications/etiology , Microspheres , Particle Size , Randomized Controlled Trials as Topic , Saphenous Vein/transplantation , Suction , Thrombosis/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...