J Bone Joint Surg Br ; 89(5): 686-92, 2007 May.
Article in English | MEDLINE | ID: mdl-17540758

ABSTRACT

The complications of impaction bone grafting in revision hip replacement includes fracture of the femur and subsidence of the prosthesis. In this in vitro study we aimed to investigate whether the use of vibration, combined with a perforated tamp during the compaction of morsellised allograft would reduce peak loads and hoop strains in the femur as a surrogate marker of the risk of fracture and whether it would also improve graft compaction and prosthetic stability. We found that the peak loads and hoop strains transmitted to the femoral cortex during graft compaction and subsidence of the stem in subsequent mechanical testing were reduced. This innovative technique has the potential to reduce the risk of intra-operative fracture and to improve graft compaction and therefore prosthetic stability.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Bone Transplantation/methods , Femur/surgery , Femoral Fractures/prevention & control , Humans , In Vitro Techniques , Materials Testing/methods , Prosthesis Failure , Reoperation/methods , Stress, Mechanical , Vibration