Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Opt Soc Am A Opt Image Sci Vis ; 39(7): 1295-1308, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-36215616

ABSTRACT

Two designs with a multiplexed superluminescent diode for ultra-high-resolution spectral-domain polarization-sensitive optical coherence tomography (UHR-PS-OCT) are introduced. In the first design, a Wollaston prism separates orthogonal polarization states next to each other on one linescan camera; the other design uses a beam displacer to separate orthogonal states onto two lines of a linescan camera with multiple rows of detectors. The coherence lengths measured with the two systems were 3.6 µm and 2.9 µm (n=1.38), respectively. Measurements were collected from the fovea of a healthy subject, a healthy subject with astigmatism, and a patient with central serous retinopathy (CSR). A single volumetric scan provides double pass retardance induced by the retinal nerve fiber layer birefringence (RNFL) and its birefringence, the cumulative double pass retardance induced by the Henle fiber layer, and the retardance that is induced by the retinal pigment epithelium-Bruch's membrane complex. The high axial resolution in UHR-PS-OCT is particularly helpful for the measurements of thin retinal tissue, such as the RNFL in the fovea, where birefringence values of around 1°/µm were found. Tilting of the retina due to a CSR or by off centering the imaging beam in the pupil causes an artificial increase in the double pass retardance induced by the RNFL and Henle fiber layer.


Subject(s)
Retina , Tomography, Optical Coherence , Birefringence , Humans , Refraction, Ocular , Retina/diagnostic imaging , Tomography, Optical Coherence/methods
2.
J Biophotonics ; 12(6): e201800192, 2019 06.
Article in English | MEDLINE | ID: mdl-30328279

ABSTRACT

As data acquisition for retinal imaging with optical coherence tomography (OCT) becomes faster, efficient collection of photons becomes more important to maintain image quality. One approach is to use a larger aperture at the eye's pupil to collect more photons that have been reflected from the retina. A 2.8-mm beam diameter system with only seven reflecting surfaces was developed for low-loss retinal imaging. The larger beam size requires defocus and astigmatism correction, which was done in a closed loop adaptive optics method using a Shack-Hartmann wavefront sensor and a deformable mirror (DM) with 140 actuators and a ±2.75 µm stroke. This DM facilitates defocus correction ranging from approximately -3 D to +3 D. Comparing the new system with a standard 1.2-mm system on a model eye, a signal-to-noise gain of 4.5 dB and a 2.3 times smaller speckle size were measured. Measurements on the retinas of five subjects showed even better results, with increases in dynamic range up to 13 dB. Note that the new sample arm only occupies 30 cm × 60 cm, which makes it highly suitable for imaging in a clinical environment. Figure: B-scan images obtained over a width of 8 deg from the right eye of a 31-year-old Caucasian male. While the left side was imaged with a standard 1.2-mm OCT system, the right side was imaged with the 2.8-mm system. Both images were collected with the same integration time and incident power, after correction of aberrations. Using the dynamic range within the images, which is determined by comparing the highest pixel value to the noise floor, a difference in dynamic range of 10.8 dB was measured between the two systems.


Subject(s)
Retina/diagnostic imaging , Tomography, Optical Coherence/methods , Humans , Optical Phenomena , Phantoms, Imaging , Retina/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...