Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Environ Microbiol ; 82(9): 2773-2782, 2016 May.
Article in English | MEDLINE | ID: mdl-26921430

ABSTRACT

There is growing interest in the application of human-associated fecal source identification quantitative real-time PCR (qPCR) technologies for water quality management. The transition from a research tool to a standardized protocol requires a high degree of confidence in data quality across laboratories. Data quality is typically determined through a series of specifications that ensure good experimental practice and the absence of bias in the results due to DNA isolation and amplification interferences. However, there is currently a lack of consensus on how best to evaluate and interpret human fecal source identification qPCR experiments. This is, in part, due to the lack of standardized protocols and information on interlaboratory variability under conditions for data acceptance. The aim of this study is to provide users and reviewers with a complete series of conditions for data acceptance derived from a multiple laboratory data set using standardized procedures. To establish these benchmarks, data from HF183/BacR287 and HumM2 human-associated qPCR methods were generated across 14 laboratories. Each laboratory followed a standardized protocol utilizing the same lot of reference DNA materials, DNA isolation kits, amplification reagents, and test samples to generate comparable data. After removal of outliers, a nested analysis of variance (ANOVA) was used to establish proficiency metrics that include lab-to-lab, replicate testing within a lab, and random error for amplification inhibition and sample processing controls. Other data acceptance measurements included extraneous DNA contamination assessments (no-template and extraction blank controls) and calibration model performance (correlation coefficient, amplification efficiency, and lower limit of quantification). To demonstrate the implementation of the proposed standardized protocols and data acceptance criteria, comparable data from two additional laboratories were reviewed. The data acceptance criteria proposed in this study should help scientists, managers, reviewers, and the public evaluate the technical quality of future findings against an established benchmark.


Subject(s)
Feces/microbiology , Real-Time Polymerase Chain Reaction/methods , Water Microbiology/standards , Water Pollution/analysis , Water Quality/standards , Bacteria/classification , Bacteria/genetics , DNA, Bacterial/classification , DNA, Bacterial/genetics , DNA, Bacterial/isolation & purification , Environmental Monitoring/methods , Feces/chemistry , Humans , Real-Time Polymerase Chain Reaction/standards , Reproducibility of Results , Sewage/microbiology
2.
J Environ Manage ; 136: 112-20, 2014 Apr 01.
Article in English | MEDLINE | ID: mdl-24583609

ABSTRACT

Some molecular methods for tracking fecal pollution in environmental waters have both PCR and quantitative PCR (qPCR) assays available for use. To assist managers in deciding whether to implement newer qPCR techniques in routine monitoring programs, we compared detection limits (LODs) and costs of PCR and qPCR assays with identical targets that are relevant to beach water quality assessment. For human-associated assays targeting Bacteroidales HF183 genetic marker, qPCR LODs were 70 times lower and there was no effect of target matrix (artificial freshwater, environmental creek water, and environmental marine water) on PCR or qPCR LODs. The PCR startup and annual costs were the lowest, while the per reaction cost was 62% lower than the Taqman based qPCR and 180% higher than the SYBR based qPCR. For gull-associated assays, there was no significant difference between PCR and qPCR LODs, target matrix did not effect PCR or qPCR LODs, and PCR startup, annual, and per reaction costs were lower. Upgrading to qPCR involves greater startup and annual costs, but this increase may be justified in the case of the human-associated assays with lower detection limits and reduced cost per sample.


Subject(s)
Charadriiformes , DNA, Bacterial/isolation & purification , Limit of Detection , Polymerase Chain Reaction/economics , Polymerase Chain Reaction/methods , Water/chemistry , Animals , Bacteroidetes/isolation & purification , Biological Assay/economics , Biological Assay/methods , Costs and Cost Analysis , Endpoint Determination/economics , Endpoint Determination/methods , Environmental Pollution/analysis , Feces/chemistry , Genetic Markers , Humans , Linear Models , Logistic Models , Water Microbiology/standards , Water Quality/standards
3.
Water Res ; 47(18): 6897-908, 2013 Nov 15.
Article in English | MEDLINE | ID: mdl-23992621

ABSTRACT

A number of PCR-based methods for detecting human fecal material in environmental waters have been developed over the past decade, but these methods have rarely received independent comparative testing in large multi-laboratory studies. Here, we evaluated ten of these methods (BacH, BacHum-UCD, Bacteroides thetaiotaomicron (BtH), BsteriF1, gyrB, HF183 endpoint, HF183 SYBR, HF183 Taqman(®), HumM2, and Methanobrevibacter smithii nifH (Mnif)) using 64 blind samples prepared in one laboratory. The blind samples contained either one or two fecal sources from human, wastewater or non-human sources. The assay results were assessed for presence/absence of the human markers and also quantitatively while varying the following: 1) classification of samples that were detected but not quantifiable (DNQ) as positive or negative; 2) reference fecal sample concentration unit of measure (such as culturable indicator bacteria, wet mass, total DNA, etc); and 3) human fecal source type (stool, sewage or septage). Assay performance using presence/absence metrics was found to depend on the classification of DNQ samples. The assays that performed best quantitatively varied based on the fecal concentration unit of measure and laboratory protocol. All methods were consistently more sensitive to human stools compared to sewage or septage in both the presence/absence and quantitative analysis. Overall, HF183 Taqman(®) was found to be the most effective marker of human fecal contamination in this California-based study.


Subject(s)
Bacteria, Anaerobic/classification , DNA, Bacterial/analysis , Environmental Monitoring/methods , Feces/microbiology , Real-Time Polymerase Chain Reaction/methods , Water Microbiology , Water Pollution/analysis , Bacteria, Anaerobic/genetics , Bacteria, Anaerobic/isolation & purification , Bacteria, Anaerobic/metabolism , California , Humans , Limit of Detection , Wastewater/microbiology
4.
Electrophoresis ; 33(12): 1736-45, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22740462

ABSTRACT

The goal of this study is to explore the application of epigenetic markers in the identification of biofluids that are commonly found at the crime scene. A series of genetic loci were examined in order to define epigenetic markers that display differential methylation patterns between blood, saliva, semen, and epithelial tissue. Among the different loci tested, we have identified a panel of markers, C20orf117, ZC3H12D, BCAS4, and FGF7, that can be used in the determination of these four tissue types. Since methylation modifications occur at cytosine bases that are immediately followed by guanine bases (CpG sites), methylation levels were measured at CpG sites spanning each marker. Up to 11 samples of each tissue type were collected and subjected to bisulfite modification to convert unmethylated CpG-associated cytosine bases to thymine bases. The bisulfite modified DNA was then amplified via nested PCR using a primer set of which one primer was biotin labeled. Biotinylated PCR products were in turn analyzed and the methylation level at each CpG site was quantitated by pyrosequencing. The percent methylation values at each CpG site were determined and averaged for each tissue type. The results indicated significant methylation differences between the tissue types. The methylation patterns at the ZC3H12D and FGF7 loci differentiated sperm from blood, saliva, and epithelial cells. The C20orf117 locus differentiated blood from sperm, saliva, and epithelial cells and saliva was differentiated from blood, sperm, and epithelial cells at a fourth locus, BCAS4. The results of this study demonstrate the applicability of epigenetic markers as a novel tool for the determination of biofluids using bisulfite modification and pyrosequencing.


Subject(s)
DNA Methylation , DNA/analysis , Forensic Genetics/methods , Sequence Analysis, DNA/methods , Adult , Analysis of Variance , CpG Islands , DNA/blood , DNA/chemistry , DNA/genetics , Epigenomics , Epithelial Cells/chemistry , Female , Genetic Markers/genetics , Humans , Male , Middle Aged , Organ Specificity , Polymerase Chain Reaction , Reproducibility of Results , Saliva/chemistry , Spermatozoa/chemistry , Sulfites
SELECTION OF CITATIONS
SEARCH DETAIL
...