Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 246
Filter
1.
PLoS One ; 19(5): e0303849, 2024.
Article in English | MEDLINE | ID: mdl-38768185

ABSTRACT

PURPOSE: Random noise-moving images (noises) can make glaucoma patients with no subjective symptoms aware of visual field abnormalities. To explore this concept, we developed a noise using computer graphics (CG) and investigated the difference in the subjective perception of visual field abnormalities between CG and conventional analog noises. METHODS: We enrolled individuals with glaucoma (205 eyes), preperimetric glaucoma (PPG; 19 eyes), and normal eyes (35 eyes). For a CG noise, a series of still images was made by randomly selecting five monochromatic tones on 2-mm square dots, and these images were drawn at 60 frames per second (fps) to create a noise-moving image. The participants were asked to describe their perceived shadows on a paper. The results were categorized as follows based on the pattern deviation probability map of the Humphrey field analyzer (HFA): "agreement," "partial agreement," "disagreement," and "no response." The glaucoma stage was classified into four stages, from M1 to M4, based on the HFA's mean deviation. RESULT: The detection rates (agreement and partial agreement) were 80.5% and 65.4% for the CG and analog noises, respectively, with CG noise showing a significantly higher detection rate in all glaucoma eyes (P < 0.001). The detection rates tended to increase as the glaucoma stage progressed, and in Stage M3, these were 93.9% and 78.8% for the CG and analog noises, respectively. The PPG eyes did not exhibit subjective abnormalities for both noises. The specificity values were 97.1% and 100% for the CG and analog noises, respectively. CONCLUSION: The CG noise is more effective than the analog noise in evaluating the subjective perception of visual field abnormalities in patients with glaucoma.


Subject(s)
Computer Graphics , Glaucoma , Visual Fields , Humans , Glaucoma/physiopathology , Visual Fields/physiology , Female , Male , Middle Aged , Aged , Visual Field Tests/methods , Adult , Visual Perception/physiology
2.
Eye Contact Lens ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38728248

ABSTRACT

ABSTRACT: Radial keratotomy (RK) was commonly performed in the 1980s and 1990s. We aimed to clarify the current status of post-RK refractive correction and treatment. We retrospectively reviewed the charts of 70 patients with a history of RK. Of the 70 patients, 44 were identified for clinical outcomes. Refractive or therapeutic intervention (rigid gas-permeable contact lens fit, spectacle prescription, corneal surgery, and use of pilocarpine hydrochloride for photophobia) was possible in 59% of patients with postoperative visual deterioration after RK; in the remaining 41%, therapeutic intervention was not possible. Rigid gas-permeable contact lens fit for corneal irregular astigmatism was the most common refractive intervention and was effective in 36% of cases in the university hospital.

3.
J Cataract Refract Surg ; 50(5): 492-497, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38237070

ABSTRACT

PURPOSE: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. SETTING: National Hospital Organization, Tokyo Medical Center, Japan. DESIGN: Retrospective case series. METHODS: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. RESULTS: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). CONCLUSIONS: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.


Subject(s)
Axial Length, Eye , Biometry , Lenses, Intraocular , Optics and Photonics , Phacoemulsification , Refraction, Ocular , Tomography, Optical Coherence , Humans , Axial Length, Eye/pathology , Axial Length, Eye/diagnostic imaging , Retrospective Studies , Biometry/methods , Male , Female , Tomography, Optical Coherence/methods , Refraction, Ocular/physiology , Lens Implantation, Intraocular , Aged , Middle Aged , Aged, 80 and over , Visual Acuity/physiology , Pseudophakia/physiopathology
4.
Br J Ophthalmol ; 2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38242700

ABSTRACT

AIM: To develop an artificial intelligence (AI) algorithm that diagnoses cataracts/corneal diseases from multiple conditions using smartphone images. METHODS: This study included 6442 images that were captured using a slit-lamp microscope (6106 images) and smartphone (336 images). An AI algorithm was developed based on slit-lamp images to differentiate 36 major diseases (cataracts and corneal diseases) into 9 categories. To validate the AI model, smartphone images were used for the testing dataset. We evaluated AI performance that included sensitivity, specificity and receiver operating characteristic (ROC) curve for the diagnosis and triage of the diseases. RESULTS: The AI algorithm achieved an area under the ROC curve of 0.998 (95% CI, 0.992 to 0.999) for normal eyes, 0.986 (95% CI, 0.978 to 0.997) for infectious keratitis, 0.960 (95% CI, 0.925 to 0.994) for immunological keratitis, 0.987 (95% CI, 0.978 to 0.996) for cornea scars, 0.997 (95% CI, 0.992 to 1.000) for ocular surface tumours, 0.993 (95% CI, 0.984 to 1.000) for corneal deposits, 1.000 (95% CI, 1.000 to 1.000) for acute angle-closure glaucoma, 0.992 (95% CI, 0.985 to 0.999) for cataracts and 0.993 (95% CI, 0.985 to 1.000) for bullous keratopathy. The triage of referral suggestion using the smartphone images exhibited high performance, in which the sensitivity and specificity were 1.00 (95% CI, 0.478 to 1.00) and 1.00 (95% CI, 0.976 to 1.000) for 'urgent', 0.867 (95% CI, 0.683 to 0.962) and 1.00 (95% CI, 0.971 to 1.000) for 'semi-urgent', 0.853 (95% CI, 0.689 to 0.950) and 0.983 (95% CI, 0.942 to 0.998) for 'routine' and 1.00 (95% CI, 0.958 to 1.00) and 0.896 (95% CI, 0.797 to 0.957) for 'observation', respectively. CONCLUSIONS: The AI system achieved promising performance in the diagnosis of cataracts and corneal diseases.

5.
Eye Contact Lens ; 50(1): 16-22, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37732884

ABSTRACT

OBJECTIVES: To characterize higher-order aberrations (HOAs) in different severities of keratoconus (KC) from the anterior and posterior corneal surfaces and whole eye using an integrated Scheimpflug corneal tomographer/Hartmann-Shack wavefront aberrometer. METHODS: This study included eyes with clinical KC, topographic KC (no clinical signs), fellow eyes with very asymmetric ectasia with normal topography and no clinical signs (VAE-NT), and control eyes. Corneal and ocular wavefront aberrations were obtained using an integrated Scheimpflug tomographer/Hartmann-Shack wavefront aberrometer. The diagnostic capability of distinguishing VAE-NT from the control was also tested. RESULTS: This study included 68 eyes with clinical KC, 44 with topographic KC, 26 with VAE-NT, and 45 controls. Clinical KC had significantly greater total HOAs and coma from the anterior and posterior corneal surfaces and whole eye than the other groups ( P <0.05). Although topographic KC had significantly greater values in all wavefront parameters than the control ( P <0.05), ocular and corneal HOAs did not differ between the VAE-NT and control groups. The coma from the anterior cornea in topographic KC was significantly greater than that in VAE-NT ( P <0.05); the coma from the posterior cornea and whole eye did not differ. Total HOAs from the anterior corneal surface exhibited the highest area under the receiver operating characteristic curve value of 0.774 (sensitivity, 73%; specificity, 78%). CONCLUSION: A comprehensive wavefront assessment can be used to quantitatively evaluate corneal and ocular HOAs across various severity of KC. Total HOAs from the anterior corneal surface exhibited the potential ability in distinguishing VAE-NT from the control eyes.


Subject(s)
Corneal Wavefront Aberration , Keratoconus , Humans , Keratoconus/diagnosis , Coma , Corneal Topography , Cornea , ROC Curve , Corneal Wavefront Aberration/diagnosis
6.
J Clin Med ; 12(22)2023 Nov 07.
Article in English | MEDLINE | ID: mdl-38002573

ABSTRACT

PURPOSE: To evaluate the performance of traditional vergence formulas with segmented axial length (AL) compared to traditional composite AL in extremely long eyes, and to determine whether the segmented AL can be extended to the new-generation formulas, including the Barrett Universal II, Emmetropia Verifying Optical 2.0 (EVO2), Hill-RBF 3.0 (Hill3), Kane, and Ladas Super formula (LSF) formulas in extremely long eyes. SETTING: National Hospital. Organization, Tokyo Medical Center, Japan. DESIGN: Retrospective case series. METHODS: Consecutive patients who underwent uncomplicated cataract surgery implanted with a three-piece intraocular lens between December 2015 and March 2021 were retrospectively reviewed. The composite AL was measured with a swept-source optical coherence tomography (SS-OCT) biometer using a mean refractive index. The segmented AL was calculated by summing the geometric lengths of the ocular segments (cornea, aqueous, lens, and vitreous) using multiple specific refractive indices based on the data obtained by the SS-OCT-based biometer. When refraction was measured at three months postoperatively, the median absolute errors (MedAEs) were calculated with two ALs for each formula. RESULTS: The study included 31 eyes of 22 patients. The segmented AL (30.45 ± 1.23 mm) was significantly shorter than the composite AL (30.71 ± 1.28 mm, p < 0.001). The MedAEs were significantly reduced when using segmented AL for SRK/T, Haigis, Hill3, and LSF, compared to those obtained using composite AL (0.38 vs. 0.62, 0.48 vs. 0.79, 0.50 vs. 0.90, 0.34 vs. 0.61, p < 0.001 for all formulas, respectively). On the contrary, the MedAE obtained by Kane with segmented AL was significantly worse compared to the one with composite AL (0.35 vs. 0.27, p = 0.03). CONCLUSION: In extremely high myopic eyes, the segmented AL improves the performance of SRK/T, Haigis, Hill3, and LSF formulas compared to the composite AL, while the segmented AL worsens the prediction accuracy of the Kane formula.

7.
Steroids ; 200: 109328, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37863411

ABSTRACT

Fasting induces metabolic changes in muscles, which are differentiated by muscle fiber type. In this study, the mechanism of fasting-induced muscle atrophy in rats was examined to determine the differences between muscle fiber types in energy production. Fasting for 96 h did not alter the weight of the soleus (SOL), a fiber type I muscle, but did significantly reduce the weight of gastrocnemius (GM), a fiber type II muscle. GM, SOL and blood pregnenolone and testosterone levels decreased under fasting, which induced energy deprivation, whereas corticosterone (CORT) levels significantly increased. However, the expression of 3ß-HSD and P45011ß in GM was unaffected by fasting. The decrease in GM weight may be due to decreased levels of testosterone and reduced synthesis of mammalian target of rapamycin (mTOR). Significant increases in CORT both GM and SOL were associated with increases in the amount of branched-chain amino acids available for energy production. However, decreased levels of mTOR and IGF1 and increased levels of CORT and IL-6 in SOL suggest that GM proteolysis was followed by SOL proteolysis for additional energy production. In conclusion, IGF1 levels decreased significantly in SOL, whereas those of IL-6 significantly increased in SOL and blood but decreased in GM. Blood branched-chain amino acids (BCAA) levels were unaffected due to fasting, whereas an increase was noted in the levels of BCAA in GM and SOL. These results show that fasting for 96 h restricts energy supply, producing fast-twitch muscle atrophy followed by slow-twitch muscle atrophy.


Subject(s)
Interleukin-6 , Muscle Fibers, Skeletal , Rats , Male , Animals , Interleukin-6/metabolism , Muscle Fibers, Skeletal/metabolism , Muscular Atrophy/metabolism , Muscle, Skeletal/metabolism , Fasting , Amino Acids, Branched-Chain/metabolism , Testosterone/metabolism , TOR Serine-Threonine Kinases/metabolism , Mammals/metabolism
8.
Eye Contact Lens ; 49(11): 483-488, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37713280

ABSTRACT

OBJECTIVES: To evaluate the optical quality of different toric contact lens (CL) designs and compare their on-eye visual correction performance. METHODS: Twenty soft CL wearers aged 20 to 39 years were enrolled. Two daily disposable silicone-hydrogel toric CLs were tested: the "Eyelid Stabilized Design" (ESD-CL) and prism-ballast design (PB-CL); a spherical daily disposable silicone hydrogel CL (spherical CL) was used as a control. On-eye performance was compared for corrected distance visual acuity (CDVA), astigmatism, and ocular higher-order aberrations (HOAs); astigmatism and ocular HOAs were measured with a wavefront sensor. The subjective quality of vision, rated for "blurred vision" and "double vision," lens rotation, and fitting were also compared. RESULTS: The ESD-CLs, PB-CL, and no-CL provided better CDVA than spherical CL ( P <0.05). Compared with spherical CL and no CL, PB-CL and ESD-CLs caused significantly lesser astigmatism ( P <0.05). Coma was significantly lesser with ESD-CLs than that with PB-CL ( P <0.05); total HOAs did not differ among the four conditions. The subjective ratings for blurred and double vision were significantly lower with ESD-CLs than those with spherical CL ( P <0.05). CONCLUSIONS: Toric CLs provide a better CDVA than spherical CLs. However, differences in coma and subjective symptoms may occur because of the design of toric CLs.


Subject(s)
Astigmatism , Contact Lenses, Hydrophilic , Humans , Astigmatism/therapy , Diplopia , Coma , Hydrogels , Silicones , Refraction, Ocular
9.
Pathology ; 55(5): 629-636, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37286471

ABSTRACT

Overexpression of the epidermal growth factor receptor family member HER3 (erbB3) has been implicated in several types of cancer and recently drugs targeting HER3 have shown promising clinical activity. In melanoma, HER3 overexpression has been linked to both metastasis formation and resistance to drug therapy in cell culture models. Here, we sought to characterise the expression of HER3 in 187 melanoma biopsies (149 cutaneous, 38 mucosal) using immunohistochemistry, as well as to analyse the association between HER3 expression and molecular, clinical and pathological variables. A subset of the cutaneous melanoma specimens was taken prior to treatment with immune checkpoint blockade therapy (pre-ICB) (n=79). HER3 expression (≥1+) was observed in 136 of 187 samples (∼73%). HER3 expression was found to be markedly lower in the mucosal melanomas, with 17 of the 38 tumours (∼45%) demonstrating no HER3 expression. In cutaneous melanomas, there was a negative association between HER3 expression and mutational load, a positive association with NRAS mutational status, and a trend of negative association with PD-L1 expression. In the pre-ICB cohort, an association was found between high HER3 expression (≥2+) and overall survival after anti-PD-1-based immunotherapy. Overall, our results indicate that HER3 is a promising therapeutic avenue in cutaneous melanoma worthy of further clinical evaluation.


Subject(s)
Melanoma , Skin Neoplasms , Humans , Melanoma/pathology , Skin Neoplasms/pathology , Skin/pathology , Immunohistochemistry , Melanoma, Cutaneous Malignant
10.
Eye Contact Lens ; 49(6): 258-261, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37200044

ABSTRACT

ABSTRACT: We retrospectively examined corneal refractive power in three patients who had been followed up for more than 20 years after radial keratotomy (RK) with microperforations (MPs). All patients underwent RK in both eyes and were referred to our clinic because of postoperative decreased vision. MP was observed in five of the six eyes at the initial visit. The corneal refractive power of the anterior and posterior surfaces of the 6-mm-diameter cornea was examined using Fourier analysis based on corneal shape analysis using anterior segment optical coherence tomography. The spherical components decreased in all three cases. The asymmetry and higher-order irregularity components and fluctuations in corneal refractive power were markedly greater in the two cases with MP in both eyes. Fluctuations in corneal refractive power were observed at more than 20 years after RK with MP. Therefore, careful observation is necessary, even after a long-term postoperative follow-up period.


Subject(s)
Keratotomy, Radial , Humans , Keratotomy, Radial/methods , Retrospective Studies , Cornea/surgery , Postoperative Period
11.
J Sci Food Agric ; 103(11): 5609-5615, 2023 Aug 30.
Article in English | MEDLINE | ID: mdl-37066700

ABSTRACT

BACKGROUND: It is reported that broilers with 'wooden breast' have poor processing properties, such as low binding and water-holding capacities. However, the reason for the poor functional characteristics has not been clarified. In this study, myosin was extracted from a wooden breast. Its physicochemical properties were investigated to clarify the relationship between the structure and physicochemical properties of the heating gel of myosin obtained from the wooden breast. RESULTS: The turbidity of myosin solution extracted from wooden breast increased with increase in the heat treatment to a higher value than that from the normal breast meat myosin. The solubility of myosin collected from a wooden breast after heating decreased like normal breast muscle myosin. The surface hydrophobicity of myosin removed from wooden breast increased continually above 60 °C, unlike the change in surface hydrophobicity of normal breast myosin. The free thiol group of myosin extracted from the wooden breast was higher than normal breast myosin before and after heating. The apparent elasticity of heat-induced gels and chicken meat sausages was significantly lower in sausages and gel with wooden breast than normal ones (P < 0.05). The microstructure of the heated gel of normal myosin showed a fine network structure. In contrast, the heat-induced gel of wooden breast-extracted myosin showed a structure with loosely connected aggregates and many gaps. CONCLUSION: The coarseness of the internal gel structure of myosin extracted from wooden breast was shown to affect the apparent elasticity of the gel and sausages made from the chicken meat. © 2023 Society of Chemical Industry.


Subject(s)
Chickens , Hot Temperature , Animals , Chickens/physiology , Myosins/chemistry , Pectoralis Muscles , Gels/chemistry
12.
Chem Biodivers ; 20(4): e202200924, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36929088

ABSTRACT

The hepatitis E virus (HEV) causes a common infectious disease that infects pigs, wild boars, deer, and humans. In most cases, humans are infected by eating raw meat. Some essential oils have been reported to exhibit antiviral activities. In this study, in order to investigate the anti-HEV properties of essential oils, the immunoreactivities of HEV antigen proteins against the relevant antibodies were analyzed after the HEV antigens underwent treatment with various essential oils. The essential oils extracted from the tea tree, which was previously reported to exhibit antiviral activity, lavender, and lemon had strongly reduced activity. We found that treatment with the essential oil prepared from Sakhalin spruce was associated with the strongest reduction in immunoreactivity of HEV antigen protein(s) among the tested substances. The main volatile constituents of Sakhalin spruce essential oil were found to be bornyl acetate (32.30 %), α-pinene (16.66 %), camphene (11.14 %), camphor (5.52 %), ß-phellandrene (9.09 %), borneol (4.77 %), and limonene (4.57 %). The anti-HEV properties of the various components of the essential oils were examined: treatment with bornyl acetate, the main component of Sakhalin spruce oil, α-pinene, the main component of tea tree oil, and limonene, the main component of lemon oil, resulted in a strong reduction in HEV antigen immunoreactivity. These results indicate that each main component of the essential oils plays an important role in the reduction of the immunoreactivity of HEV antigen protein(s); they also suggest that Sakhalin spruce essential oil exhibits anti-HEV activity. In a formulation with the potential to eliminate the infectivity of HEV in foodborne infections, this essential oil can be applied as an inactivating agent for meat processing and cooking utensils, such as knives and chopping boards.


Subject(s)
Deer , Hepatitis E virus , Oils, Volatile , Picea , Animals , Swine , Humans , Oils, Volatile/pharmacology , Limonene , Antiviral Agents
13.
Eye Contact Lens ; 49(3): 98-103, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36729105

ABSTRACT

OBJECTIVES: To assess agreement between measurements of ocular wavefront aberrations obtained using the Pentacam AXL Wave (Oculus Optikgeräte GmbH) (Aberrometer A) and KR-1W (Topcon Corp) (Aberrometer B), both of which are based on the Hartmann-Shack principle. METHODS: In this prospective case-control study, ocular wavefront aberrations measurements were obtained using both aberrometers in patients with keratoconus (KC) and control participants. Ocular wavefront aberrations were measured through the natural pupil without dilation using both devices in a dark room. For both aberrometers, accommodation was inhibited by automatically adding fogging. The individual Zernike coefficients from the second to fourth order were compared between the two aberrometers for a 4-mm pupil diameter. RESULTS: Twenty-six KC and 29 control eyes were assessed. Statistically significant correlations ( P <0.05) were observed for all Zernike coefficients, except for Z 4-2 in the control group. Bland-Altman analysis indicated good agreement between aberrometers and no statistically significant differences in the control group. However, in the KC group, patterns of proportional error were observed in vertical coma Z 3-1 (r=0.338, P =0.008), trefoil Z 4-4 (r=0.701, P =0.003), secondary astigmatism Z 4-2 (r=0.348, P =0.025), and spherical aberrations Z 40 (r=0.407, P =0.012). CONCLUSIONS: The Zernike coefficient values measured by the two aberrometers were well correlated in the control and KC groups. However, in eyes with KC, Aberrometer B tended to present greater values in several Zernike coefficients than Aberrometer A, suggesting that wavefront measurements obtained using the two aberrometers are not interchangeable in patients with KC.


Subject(s)
Keratoconus , Refraction, Ocular , Humans , Case-Control Studies , Visual Acuity , Pupil , Vision Disorders
14.
Br J Pharmacol ; 180(6): 762-774, 2023 03.
Article in English | MEDLINE | ID: mdl-36377519

ABSTRACT

BACKGROUND AND PURPOSE: Intratumour heterogeneity frequently leads to drug resistance, which is a major issue in drug discovery. Drug distribution is one of the key factors for elucidating the resistance mechanism; however, quantitative and regional drug measurement is challenging. Here, we developed a novel ultra-sensitive analytical method and applied it to HER3-targeting antibody-drug conjugate patritumab deruxtecan (HER3-DXd), aiming to explore its payload (DXd) distribution within heterogeneous tissues. EXPERIMENTAL APPROACH: The developed analytical method is named LDMS-CE-MS, a capillary electrophoresis-mass spectrometry (CE-MS) coupled with a novel sample preconcentration/separation method called "large-volume dual-sample stacking by micelle collapse and sweeping (LDMS)". First, the analytical performance of LDMS-CE-MS for DXd detection was evaluated. Subsequently, we evaluated the bystander effect of HER3-DXd, where tumour tissues were excised from xenograft models and clinical specimens after administration of HER3-DXd. HER3-high expression, adjacent, and HER3-low expression regions were then sampled by laser microdissection to quantify the released DXd. KEY RESULTS: LDMS concentrated DXd by 1000-fold and separated it from the hydrophilic bio-matrix through continuous capture and release by the charged micelles, allowing quantification at sub-attomole-level. DXd concentrations decreased in the order of antigen-high expression > adjacent > antigen-low expression regions in the tumour xenograft model, whereas in clinical specimens, adjacent and antigen-high expression regions had approximately the same concentration. These distributions represent a bystander effect. CONCLUSIONS AND IMPLICATIONS: Our LDMS-CE-MS successfully visualized the attomole-level drug distributions in heterogeneous clinical specimens. This new platform opens a new era of quantitative pharmacokinetic analysis, facilitating drug discovery and development.


Subject(s)
Electrophoresis, Capillary , Neoplasms , Humans , Electrophoresis, Capillary/methods , Mass Spectrometry/methods , Neoplasms/pathology , Micelles
15.
Ophthalmol Ther ; 12(2): 867-878, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36542257

ABSTRACT

INTRODUCTION: In this study, clinical performance of a hydrophobic acrylic diffractive trifocal intraocular lens (IOL) with double C-loop haptics was evaluated in Japanese cataract eyes. METHODS: Twenty-three patients had bilateral cataract surgery with the implantation of a trifocal IOL with double C-loop haptics. Postoperative examinations at 6 months included assessing uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA) at 5 m, uncorrected intermediate visual acuity (UIVA), distance-corrected intermediate visual acuity (DCIVA) at 80 cm, uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) at 40 cm. Binocular defocus, contrast sensitivity, spectacle independence, symptoms of photic phenomena and quality of vision (QOV) were also observed. RESULTS: Twenty-three patients received 46 IOLs binocularly. Manifest refraction spherical equivalent was - 0.227 ± 0.385 D (mean ± standard deviation) at 6 months postoperatively. Binocular UDVA, binocular UIVA and binocular UNVA were - 0.101 ± 0.065, - 0.021 ± 0.079 and 0.022 ± 0.095 logMAR units, respectively. Binocular CDVA, binocular DCIVA and binocular DCNVA were - 0.151 ± 0.044, - 0.042 ± 0.067 and - 0.011 ± 0.080 logMAR, respectively. Binocular CDVA of 0.00 logMAR or better was obtained in the defocus from - 3.0 D until + 0.5 D. Only 8.7% of patients required the use of spectacles postoperatively. There were no symptoms of glare, halo and light disturbance in 78.3%, 56.5% and 69.6% of patients, respectively. QOV scores significantly improved postoperatively (P < 0.0001). CONCLUSION: The hydrophobic acrylic trifocal IOL with double C-loop haptics provides good visual performance at all distances and produces high spectacle independence rate and patient satisfaction. TRIAL REGISTRATION NUMBER: NCT04699266 (Clinicaltrials.gov).

16.
Graefes Arch Clin Exp Ophthalmol ; 261(3): 761-767, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36178505

ABSTRACT

PURPOSE: To evaluate the corneal biomechanical features of eyes with granular corneal dystrophy type 2 (GCD2) by analyzing corneal biomechanical indices obtained using a Corvis ST (CST) dynamic ultra-high-speed Scheimpflug imaging device. METHODS: In this retrospective case-control study, 35 CST parameters were compared in normal eyes (control) and eyes of patients with GCD2 treated at Osaka University Hospital, Osaka, Japan. The parameters included the Corvis Biomechanical Index (CBI), which is important in differentiating eyes with keratoconus from normal eyes. We measured the deposition rates of lesions in the central 7-mm region of the eye and assessed the correlation between the deposition rate and the CBI. RESULTS: Twenty-one eyes with GCD2 and 23 control eyes were analyzed. Eyes with GCD2 showed significantly less corneal stiffness in 15 CST parameters than did control eyes. In particular, the CBI was remarkably higher in eyes with GCD2 than in control eyes (P = 0.000006). Additionally, the deposition rate and the CBI were positively correlated. CONCLUSIONS: GCD2 eyes had softer corneas than did control eyes in most biomechanical CST parameters, and one of the parameters (the CBI) was linked to the rate of deposited lesions. Since IOP may be underestimated in GCD2 eyes, management should be especially careful in GCD2 cases complicated by glaucoma.


Subject(s)
Cornea , Keratoconus , Humans , Retrospective Studies , Case-Control Studies , Elasticity , Keratoconus/diagnosis , Biomechanical Phenomena , Corneal Topography/methods
17.
Acta Histochem ; 124(8): 151959, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36270048

ABSTRACT

Duchenne muscular dystrophy (DMD) is a severe childhood disease characterised by progressive muscle wasting caused by widespread myofibre necrosis. Implicated in the pathology of DMD is oxidative stress, caused by excessive generation of reactive oxygen and nitrogen species (RONS). One consequence of RONS exposure is post-translational oxidative modifications to proteins, which can cause loss of protein function. This study used the dystrophic mdx mouse model for DMD to visualise the precise location of different oxidative modifications to proteins in dystrophic muscles, including both reversible (protein thiol oxidation and s-nitrosylation) and irreversible (carbonylation and dityrosine formation) oxidation at various stages of dystrophic muscle necrosis and regeneration. High levels of protein oxidation were observed in mdx myofibres undergoing degeneration and immune cell infiltration (myonecrosis). Since irreversible protein oxidation, especially dityrosine formation, was only colocalised to areas of myonecrosis, we suggest that this specific measurement could be a useful biomarker of myonecrosis. To test this we quantified dityrosines in muscle homogenates; this analysis showed significantly higher levels of dityrosines in mdx (compared with control normal) mice aged 23 days, an age when acute onset of extensive myonecrosis occurs in mdx muscles. These results indicate a major localised role of immune cells in RONS generation in dystrophic muscle, and strongly support a role for protein oxidation in myonecrosis and associated dystropathology. Consequently, the measurement of protein oxidation (specifically dityrosines) in dystrophic muscles may be a useful biomarker for indirectly quantifying myonecrosis in research studies using mdx mice and other animal models for DMD.


Subject(s)
Muscular Dystrophy, Duchenne , Mice , Animals , Mice, Inbred mdx , Muscular Dystrophy, Duchenne/metabolism , Muscle, Skeletal/metabolism , Disease Models, Animal , Reactive Oxygen Species/metabolism , Proteins/metabolism , Biomarkers/metabolism , Necrosis/metabolism , Necrosis/pathology
18.
Cancer Res ; 82(21): 4031-4043, 2022 11 02.
Article in English | MEDLINE | ID: mdl-36054550

ABSTRACT

SIGNIFICANCE: This study identifies a specific dependency on PTDSS1 for phosphatidylserine synthesis following PTDSS2 deletion and introduces novel PTDSS1 inhibitors as a therapeutic option to induce collateral lethality in cancer with PTDSS2 loss.


Subject(s)
Neoplasms , Humans , Cell Line, Tumor
19.
PLoS One ; 17(9): e0274140, 2022.
Article in English | MEDLINE | ID: mdl-36137139

ABSTRACT

Molecular and protein biomarker profiling are key to oncology drug development. Antibody-drug conjugates (ADCs) directly deliver chemotherapeutic agents into tumor cells based on unique cancer cell biomarkers. A pan-cancer tissue microarray (TMA) data set and gene panel were validated and gene signature analyses were conducted on normal and cancer tissues to refine selection of ADC targets. Correlation of mRNA and protein levels, and human epidermal growth factor receptor (HER) expression patterns were assessed. An EdgeSeq biomarker panel (2862 genes) was used across 8531 samples (23 solid cancer types/subtypes; 16 normal tissues) with an established TMA data set, and immune cell and cell cycle gene signatures were analyzed. Discriminating gene expression signatures were defined based on pathological classification of cancer subtypes. Correlative analyses of HER2 and HER3 mRNA (EdgeSeq) and protein expression (immunohistochemistry [IHC]) were performed and compared with publicly available data (The Cancer Genome Atlas [TCGA]; Cancer Cell Line Encyclopedia [CCLE]). Gene expression patterns among cancer types in the TMA (EdgeSeq) and TCGA (RNA-seq) were similar. EdgeSeq gene signature analyses aligned with the majority of pathological cancer types/subtypes and identified cancer-specific gene expression patterns. TMA IHC H-scores for HER3 varied across cancer types/subtypes. In a few cancer types, HER3 mRNA and protein expression did not align, including lower liver hepatocellular carcinoma IHC H-score, compared with mRNA. Although all TNBC and ovarian cancer subtypes expressed mRNA, some had lower protein expression. This was seen in TMA and TCGA data sets, but not in CCLE. The EdgeSeq TMA data set can expand upon current biomarker data by including cancers not currently in TCGA. The primary analysis of EdgeSeq and IHC comparison suggested a unique protein-level regulation of HER3 in some tumor subtypes and highlights the importance of investigating protein levels of ADC targets in both tumor and normal tissues.


Subject(s)
Immunoconjugates , Neoplasms , Biomarkers, Tumor/genetics , ErbB Receptors/genetics , Humans , Immunoconjugates/genetics , Neoplasms/genetics , RNA, Messenger/genetics , Receptor, ErbB-3 , Transcriptome
20.
PLoS One ; 17(8): e0273431, 2022.
Article in English | MEDLINE | ID: mdl-36040874

ABSTRACT

PURPOSE: To compare the change in intraocular lens (IOL) axial movement, corneal power, and postoperative refraction of eyes implanted with two different single-piece, open loop, acrylic foldable IOLs with planar-haptic design: one IOL with hinges vs. one IOL without hinges. The role of IOL axial movement on short-term refractive shift after cataract surgery was also evaluated. METHODS: This retrospective comparative study enrolled consecutive patients who had phacoemulsification with aspheric IOL implantation. The IOL depth (the distance from corneal endothelium to IOL surface) and corneal power were measured via anterior-segment optical coherence tomography at 4 days and 1 month postoperatively. The changes in axial movement of the IOL, corneal power, and manifest refractive spherical equivalent (MRSE) were compared among groups, and the correlations between each lens were evaluated. RESULTS: IOL with hinges was implanted in 42 eyes of 42 patients and IOL without hinges was implanted in 42 eyes of 42 patients. The change in axial movement between 4 days and 1 month was significantly smaller in the IOL with hinges group than in the IOL without hinges group (p < 0.001). The axial movement of IOL with hinges did not correlate with the MRSE change; however, the forward shift of IOL without hinges correlated with the myopic refractive change (Pearson r = 0.62, p < 0.001). CONCLUSION: The postoperative axial movement of IOL was more stable in the IOL with hinges group than the IOL without hinges group between 4 days and 1 month after cataract surgery. Even though the two study IOLs with planar-haptic design are made of similar acrylic materials, other characteristics such as hinge structure may affect IOL stability in the bag.


Subject(s)
Cataract , Lenses, Intraocular , Phacoemulsification , Humans , Lens Implantation, Intraocular/methods , Phacoemulsification/methods , Prospective Studies , Prosthesis Design , Refraction, Ocular , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...