Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Thorac Cardiovasc Surg ; 94(2): 302-5, 1987 Aug.
Article in English | MEDLINE | ID: mdl-3613631

ABSTRACT

In this report we describe the case of a 50-year-old woman with Crohn's disease of the esophagus. She had severe distal stricture that necessitated distal esophagectomy, with esophagogastric anastomosis and Nissen fundoplication. Surgical treatment of esophageal Crohn's disease is associated with a number of complications; however, on the basis of our experience and a literature review, pyloroplasty and Nissen fundoplication in addition to surgical resection seems to be associated with fewer postoperative complications.


Subject(s)
Crohn Disease/surgery , Esophagitis/surgery , Esophagus/surgery , Crohn Disease/pathology , Esophagitis/pathology , Esophagus/pathology , Female , Humans , Middle Aged , Stomach/surgery
2.
Ann Thorac Surg ; 44(1): 21-5, 1987 Jul.
Article in English | MEDLINE | ID: mdl-3606256

ABSTRACT

Because of valve malfunction and cerebral embolism reported with use of the total artificial heart, the descending aorta was reexamined as a site for a valveless counterpulsation left ventricular assist pump. The pump was introduced into the thoracic aorta at the level of the eight thoracic vertebra in 11 canine right-heart bypass preparations. Heart rate (110 beats per minute), stroke volume (20 ml), and mean arterial pressure (80 or 100 mm Hg) were precisely controlled. The pump ejection volume was adjusted to equal 1 time or 2 times the stroke volume of the dog. A 20-ml ejection led to an 11% reduction in left atrial pressure, an 11% reduction in peak left ventricular pressure, and a 20% reduction in tension time index (all, p less than .05 at a mean arterial pressure of 80 mm Hg). Systolic shortening (ultrasonic crystals) increased by 5% (p less than .05 at a mean arterial pressure of 80 mm Hg). A 40-ml pump ejection led to an 11% reduction in mean left atrial pressure, a 17% reduction in peak left ventricular pressure, and a 21% reduction in tension time index (all, p less than .05 at a mean arterial pressure of 80 mm Hg). The systolic shortening increased by 15% (p less than .05). To assess the relative risk of cerebral embolism, albumin spheres (40 to 60 micrograms) labeled with technetium-99 were injected into the pump chamber in 5 dogs (40-ml ejection, 2.1 +/- 0.1 times the dog's stroke volume).(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Aorta, Thoracic , Intra-Aortic Balloon Pumping/methods , Intracranial Embolism and Thrombosis/prevention & control , Animals , Blood Pressure , Cerebrovascular Circulation , Dogs , Heart Rate , Intra-Aortic Balloon Pumping/adverse effects , Intra-Aortic Balloon Pumping/instrumentation , Risk , Stroke Volume