ABSTRACT

The effects of biofilm formation on membrane performance were evaluated for a submerged membrane bioreactor (sMBR) system with six different types of micro- and ultrafiltration membranes (working volume=19 l). After operation for 24 h the permeability of the membranes with a larger pore size (microfiltration) decreased to that of the membranes with a much smaller pore size (ultrafiltration). Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) confirmed that biofilms could reduce the influence of the membrane surface properties. The chemical oxygen demand (COD) removal efficiency was 95% for the oily wastewater treatment in the sMBR where the filtration process made an important contribution (47% based on feed COD). Significant enhancement in COD removal occurred at the initial filtration stage because of biofilm formation and the dynamic member role of the biofilm layer. Membranes with various pore sizes had approximately the same permeate quality that was attributed to the biofilm on the membrane surfaces. Nevertheless, the ultrafiltration membranes had 43% more COD removal efficiency than the other applied membranes at the beginning of filtration (before biofilm formation) because of the smaller pore sizes and better sieving.


Subject(s)
Biofilms , Biofouling/prevention & control , Biological Oxygen Demand Analysis/instrumentation , Bioreactors , Water Purification/methods , Equipment Design , Microscopy, Electron, Scanning , Permeability , Spectroscopy, Fourier Transform Infrared , Ultrafiltration/methods
2.
Water Sci Technol ; 64(5): 1154-60, 2011.
Article in English | MEDLINE | ID: mdl-22214065

ABSTRACT

Influence of membrane material and pore size on the performance of a submerged membrane bioreactor (sMBR) for oily wastewater treatment was investigated. The sMBR had a working volume of about 19 L with flat sheet modules at the same hydrodynamic conditions. Five types of micro- and ultra-polymeric membranes containing cellulose acetate (CA), cellulose nitrate (CN), polyamide (PA), polyvinylidene difluoride (PVDF) and polyethersulfone (PES) were used and their filtration performance in terms of permeability, permeate quality and fouling intensity were evaluated. Characterization of the membranes was done by performing some analysis such as pore size distribution; contact angle and scanning electronic microscopy (SEM) microphotograph on all membranes. The quality of permeates from each membrane was identified by measuring chemical oxygen demand (COD). The results showed more irreversible fouling intensity for membranes with larger pore size which can be due to more permeation of bioparticles and colloids inside the pores. Membrane characteristics have a major role in the preliminary time of the filtration before cake layer formation so that the PA with the highest hydrophilicity had the lowest permeability decline by fouling in this period. Also, the PVDF and PES membranes had better performance according to better permeate quality in the preliminary time of the filtration related to smaller pore size and also their better fouling resistance and chemical stability properties. However, all membranes resulted in the same permeability and permeate quality after cake layer formation. An overall efficiency of about 95% in COD removal was obtained for oily wastewater treatment by the membranes used in this study.


Subject(s)
Bioreactors/microbiology , Filtration/methods , Membranes, Artificial , Waste Disposal, Fluid/methods , Cellulose/analogs & derivatives , Cellulose/chemistry , Nylons/chemistry , Polyvinyls/chemistry