Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Biomaterials ; 273: 120815, 2021 06.
Article in English | MEDLINE | ID: mdl-33894404

ABSTRACT

Cell-assembled extracellular matrix (CAM) has been used to produce vascular grafts. While these completely biological vascular grafts performed well in clinical trials, the in vivo remodeling and inflammatory response of this truly "bio" material has not yet been investigated. In this study, human CAM yarns were implanted subcutaneously in nude rats to investigate the innate immune response to this matrix. The impact of processing steps relevant to yarn manufacturing was evaluated (devitalization, decellularization, gamma sterilization, and twisting). We observed that yarns were still present after six months, and were integrated into a non-inflamed loose connective tissue. The CAM was repopulated by fibroblastic cells and blood vessels. While other yarns caused minor peripheral inflammation at an early stage (two weeks of implantation), gamma sterilization triggered a more intense host response dominated by the presence of M1 macrophages. The inflammatory response was resolved at six months. Yarn mechanical strength was decreased two weeks after implantation except for the more compact "twisted" yarn. While the strength of other yarns was stable after initial remodeling, the gamma-sterilized yarn continued to lose mechanical strength over time and was weaker than devitalized (control) yarns at six months. This is the first study to formally demonstrate that devitalized human CAM is very long-lived in vivo and does not trigger a degradative response, but rather is very slowly remodeled. This data supports a strategy to produce human textiles from CAM yarn for regenerative medicine applications where a scaffold with low inflammation and long-term mechanical properties are critical.


Subject(s)
Extracellular Matrix , Textiles , Blood Vessel Prosthesis , Fibroblasts , Humans
2.
J Tissue Eng ; 12: 2041731420978327, 2021.
Article in English | MEDLINE | ID: mdl-33633827

ABSTRACT

We have created entirely biological tissue-engineered vascular grafts (TEVGs) using sheets of cell-assembled extracellular matrix (CAM) produced by human fibroblasts in vitro. A large animal TEVG would allow long-term pre-clinical studies in a clinically relevant setting (graft size and allogeneic setting). Therefore, canine, porcine, ovine, and human skin fibroblasts were compared for their ability to form CAM sheets. Serum sourcing greatly influenced CAM production in a species-dependent manner. Ovine cells produced the most homogenous and strongest animal CAM sheets but remained ≈3-fold weaker than human sheets despite variations of serum, ascorbate, insulin, or growth factor supplementations. Key differences in cell growth dynamics, tissue development, and tissue architecture and composition were observed between human and ovine. This study demonstrates critical species-to-species differences in fibroblast behavior and how they pose a challenge when attempting to substitute animal cells for human cells during the development of tissue-engineered constructs that require long-term cultures.

3.
Acta Biomater ; 105: 111-120, 2020 03 15.
Article in English | MEDLINE | ID: mdl-31996332

ABSTRACT

In the field of tissue engineering, many groups have come to rely on the extracellular matrix produced by cells as the scaffold that provides structure and strength to the engineered tissue. We have previously shown that sheets of Cell-Assembled extracellular Matrix (CAM), which are entirely biological yet robust, can be mass-produced for clinical applications using normal, adult, human fibroblasts. In this article, we demonstrate that CAM yarns can be generated with a range of physical and mechanical properties. We show that this material can be used as a simple suture to close a wound or can be assembled into fully biological, human, tissue-engineered vascular grafts (TEVGs) that have high mechanical strength and are implantable. By combining this truly "bio" material with a textile-based assembly, this original tissue engineering approach is highly versatile and can produce a variety of strong human textiles that can be readily integrated in the body. STATEMENT OF SIGNIFICANCE: Yarn of synthetic biomaterials have been turned into textiles for decades because braiding, knitting and weaving machines can mass-produce medical devices with a wide range of shapes and mechanical properties. Here, we show that robust, completely biological, and human yarn can be produced by normal cells in vitro. This yarn can be used as a simple suture material or to produce the first human textiles. For example, we produced a woven tissue-engineered vascular grafts with burst pressure, suture retention strength and transmural permeability that surpassed clinical requirements. This novel strategy holds the promise of a next generation of medical textiles that will be mechanically strong without any foreign scaffolding, and will have the ability to truly integrate into the host's body.


Subject(s)
Biocompatible Materials/pharmacology , Textiles , Tissue Engineering , Adult , Animals , Blood Vessel Prosthesis , Humans , Rats, Nude
4.
J Mech Behav Biomed Mater ; 99: 18-26, 2019 11.
Article in English | MEDLINE | ID: mdl-31325833

ABSTRACT

Because of its low immunogenicity, biological properties, and high availability, the Human Amniotic Membrane (HAM) is widely used in the clinic and in tissue engineering research. However, while its biological characteristics are well described, its mechanical properties remain understudied especially in terms of inter- and intra-HAM variability. To guide bioengineers in the use of this natural biomaterial, a detailed cartography of the HAM's mechanical properties was performed. Maximal force (Fmax) and strain at break (Smax) were identified as the relevant mechanical criteria for this study after a combined analysis of histological sections, thickness measurements after dehydration, and uniaxial tensile tests. Eight HAMs were studied by mechanical cartography using a standardized cutting protocol and sampling pattern. On average, 103 ±â€¯10 samples were retrieved and tested per HAM. Intra-tissue variability highlighted the fact that there were two mechanically distinct areas (placental and peripheral) in each HAM. For all HAMs, placental HAM was significantly stronger by 82 ±â€¯45% and more stretchable by 19 ±â€¯6% than their peripheral counterparts. Our results also demonstrated that placental, but not peripheral, HAM presented isotropic mechanical properties. Thus, placental HAM can be a raw material of choice that could be favored especially in the development of tissue engineering products where mechanical properties play a key role.


Subject(s)
Amnion/physiology , Placenta/physiology , Tissue Engineering/methods , Tissue Scaffolds , Adult , Female , Humans , Pregnancy , Reproducibility of Results , Stress, Mechanical , Tensile Strength
5.
Acta Biomater ; 82: 56-67, 2018 12.
Article in English | MEDLINE | ID: mdl-30296619

ABSTRACT

We have previously shown that the Cell-Assembled extracellular Matrix (CAM) synthesized by normal, human, skin fibroblasts in vitro can be assembled in a completely biological vascular graft that was successfully tested in the clinic. The goal of this study was to perform a detailed analysis of the composition and the organization of this truly bio-material. In addition, we investigated whether the devitalization process (dehydration) used to store the CAM, and thus, make the material available "off-the-shelf," could negatively affect its organization and mechanical properties. We demonstrated that neither the thickness nor the mechanical strength of CAM sheets were significantly changed by the dehydration/freezing/rehydration cycle. The identification of over 50 extracellular matrix proteins highlighted the complex composition of the CAM. Histology showed intense collagen and glycosaminoglycan staining throughout the CAM sheet. The distribution of collagen I, collagen VI, thrombospondin-1, fibronectin-1, fibrillin-1, biglycan, decorin, lumican and versican showed various patterns that were not affected by the devitalization process. Transmission electron microscopy analysis revealed that the remarkably dense collagen network was oriented in the plane of the sheet and that neither fibril density nor diameter was changed by devitalization. Second harmonic generation microscopy revealed an intricate, multi-scale, native-like collagen fiber orientation. In conclusion, this bio-material displayed many tissue-like properties that could support normal cell-ECM interactions and allow implantation without triggering degradative responses from the host's innate immune system. This is consistent with its success in vivo. In addition, the CAM can be devitalized without affecting its mechanical or unique biological architecture. STATEMENT OF SIGNIFICANCE: The extracellular matrix (ECM) defines biological function and mechanical properties of tissues and organs. A number of promising tissue engineering approaches have used processed ECM from cadaver/animal tissues or cell-assembled ECM in vitro combined with scaffolds. We have shown the clinical potential of a scaffold-free approach based on an entirely biological material produced by human cells in culture without chemical processing. Here, we perform a comprehensive analysis of the properties of what can truly be called a bio-material. We also demonstrate that this material can be stored dried without losing its remarkable biological architecture.


Subject(s)
Extracellular Matrix Proteins/chemistry , Extracellular Matrix/chemistry , Fibroblasts/metabolism , Tissue Engineering , Tissue Scaffolds/chemistry , Fibroblasts/ultrastructure , Humans
6.
J Cell Biol ; 214(7): 859-73, 2016 09 26.
Article in English | MEDLINE | ID: mdl-27646271

ABSTRACT

Spatiotemporal regulation of RhoGTPases such as RhoA is required at the cell leading edge to achieve cell migration. p190RhoGAP (p190A) is the main negative regulator of RhoA and localizes to membrane protrusions, where its GTPase-activating protein (GAP) activity is required for directional migration. In this study, we investigated the molecular processes responsible for p190A targeting to actin protrusions. By analyzing the subcellular localization of truncated versions of p190A in hepatocellular carcinoma cells, we identified a novel functional p190A domain: the protrusion localization sequence (PLS) necessary and sufficient for p190A targeting to leading edges. Interestingly, the PLS is also required for the negative regulation of p190A RhoGAP activity. Further, we show that the F-actin binding protein cortactin binds the PLS and is required for p190A targeting to protrusions. Lastly, we demonstrate that cancer-associated mutations in PLS affect p190A localization and function, as well as tumor cell migration. Altogether, our data unveil a new mechanism of regulation of p190A in migrating tumor cells.


Subject(s)
Cell Movement , Guanine Nucleotide Exchange Factors/genetics , Guanine Nucleotide Exchange Factors/metabolism , Mutation/genetics , Neoplasms/genetics , Neoplasms/pathology , Actins/metabolism , Animals , Cell Line, Tumor , Cell Surface Extensions/metabolism , Cortactin/metabolism , Guanine Nucleotide Exchange Factors/chemistry , Humans , Mice , Protein Binding , Protein Domains , Pseudopodia/metabolism , Repressor Proteins , Sus scrofa , Transfection
SELECTION OF CITATIONS
SEARCH DETAIL
...