Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Comput Neurosci ; 7: 137, 2013.
Article in English | MEDLINE | ID: mdl-24187539

ABSTRACT

Simultaneously measuring the activities of all neurons in a mammalian brain at millisecond resolution is a challenge beyond the limits of existing techniques in neuroscience. Entirely new approaches may be required, motivating an analysis of the fundamental physical constraints on the problem. We outline the physical principles governing brain activity mapping using optical, electrical, magnetic resonance, and molecular modalities of neural recording. Focusing on the mouse brain, we analyze the scalability of each method, concentrating on the limitations imposed by spatiotemporal resolution, energy dissipation, and volume displacement. Based on this analysis, all existing approaches require orders of magnitude improvement in key parameters. Electrical recording is limited by the low multiplexing capacity of electrodes and their lack of intrinsic spatial resolution, optical methods are constrained by the scattering of visible light in brain tissue, magnetic resonance is hindered by the diffusion and relaxation timescales of water protons, and the implementation of molecular recording is complicated by the stochastic kinetics of enzymes. Understanding the physical limits of brain activity mapping may provide insight into opportunities for novel solutions. For example, unconventional methods for delivering electrodes may enable unprecedented numbers of recording sites, embedded optical devices could allow optical detectors to be placed within a few scattering lengths of the measured neurons, and new classes of molecularly engineered sensors might obviate cumbersome hardware architectures. We also study the physics of powering and communicating with microscale devices embedded in brain tissue and find that, while radio-frequency electromagnetic data transmission suffers from a severe power-bandwidth tradeoff, communication via infrared light or ultrasound may allow high data rates due to the possibility of spatial multiplexing. The use of embedded local recording and wireless data transmission would only be viable, however, given major improvements to the power efficiency of microelectronic devices.

2.
Proc Natl Acad Sci U S A ; 104(22): 9198-203, 2007 May 29.
Article in English | MEDLINE | ID: mdl-17517654

ABSTRACT

We here report on the design of a planar microslot waveguide NMR probe with an induction element that can be fabricated at scales from centimeters to nanometers to allow analysis of biomolecules at nano- or picomole quantities, reducing the required amount of materials by several orders of magnitude. This device demonstrates the highest signal-to-noise ratio for a planar detector to date, measured by using the anomeric proton signal from a 15.6-nmol sample of sucrose. This probe had a linewidth of 1.1 Hz for pure water without susceptibility matching. Analysis of 1.57 nmol of ribonuclease-A shows high sensitivity in one- and two-dimensional NMR spectra. Along with reducing required sample volumes, this integrated geometry can be packed in parallel arrays and combined with microfluidic systems. Further development of this device may have broad implications not only for advancing our understanding of many intractable protein structures and their folding, molecular interactions, and dynamic behaviors, but also for high-sensitivity diagnosis of a number of protein conformational diseases.


Subject(s)
Magnetic Resonance Spectroscopy/instrumentation , Magnetic Resonance Spectroscopy/methods , Computer Simulation , Sucrose/chemistry , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...