Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Phys Chem B ; 110(32): 15973-81, 2006 Aug 17.
Article in English | MEDLINE | ID: mdl-16898753

ABSTRACT

Thin films of guanosine and uridine ribonucleic acid (RNA) homopolymers (poly rG, poly rU) were grown in high vacuum in several steps on highly oriented pyrolytic graphite (HOPG) using electrospray deposition. Between deposition steps, the sample surface was characterized with X-ray and ultraviolet photoemission spectroscopy (XPS, UPS). The resulting spectra series allowed the determination of the orbital alignment at the HOPG interface, as well as the ionization energies of the homopolymer thin films. Comparison with earlier results on cytidine and adenosine RNA homopolymers (poly rC, poly rA) indicates significant ionization energy and charge injection barrier differences between purines and pyrimidines.


Subject(s)
Poly G/chemistry , Poly U/chemistry , RNA/chemistry , Graphite/chemistry , Membranes, Artificial , Poly A/chemistry , Poly C/chemistry , Surface Properties
2.
J Phys Chem B ; 110(6): 2692-9, 2006 Feb 16.
Article in English | MEDLINE | ID: mdl-16471873

ABSTRACT

Ribonucleic acid (RNA) polycytidine (poly rC) homopolymer thin films were prepared on highly oriented pyrolytic graphite (HOPG) substrates. The films were grown from aqueous solution directly in a vacuum in multiple steps with use of an electrospray (ES) deposition system. Before poly rC deposition and after each deposition step the sample was characterized with X-ray and ultraviolet photoemission spectroscopy (XPS, UPS). Evaluation of the UP-spectra sequence allowed the determination of ionization energy and highest occupied molecular orbital (HOMO) electronic structure, as well as the charge injection barriers between HOPG and poly rC. Comparison with earlier results on polyadenosine (poly rA) indicates significant differences between ionization energies (poly rC: 8.1 eV; poly rA: 6.8 eV) and orbital alignment at the graphite interface. The larger ionization energy of poly rC results in a larger hole injection barrier and a smaller electron injection barrier relative to the HOPG Fermi level.


Subject(s)
Poly C/chemistry , RNA/chemistry , Electrons , Graphite/chemistry , Kinetics , Membranes, Artificial , Microscopy, Atomic Force/methods , Particle Size , Sensitivity and Specificity , Spectrophotometry/methods , Spectrophotometry, Ultraviolet/methods , Surface Properties , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...