Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Angiology ; 75(3): 231-239, 2024 Mar.
Article in English | MEDLINE | ID: mdl-36629740

ABSTRACT

The systemic immune-inflammation index (SII) and systemic inflammation response index (SIRI) have previously demonstrated predictive value in coronary artery disease (CAD). We developed on an expanded, novel systemic immune-inflammation response index (SIIRI), calculated as peripheral neutrophil × monocyte × platelet ÷ lymphocyte count. We assessed 240 patients with an acute coronary syndrome that subsequently underwent percutaneous coronary intervention. CAD severity was measured using the SYNTAX score. Laboratory measurements, including cell counts, were obtained on admission. On multivariate analysis, the SIIRI was an independent predictor of severe CAD with an adjusted odds ratio (OR) of 1.666 [1.376-2.017] per 105-unit increase. The SIIRI had the highest area under the receiver operator curve of .771 [.709-.833] compared to the SII, SIRI neutrophil-lymphocyte ratio, monocyte-lymphocyte ratio, and platelet-lymphocyte ratio. The optimal cut-off for SIIRI was 4.3 × 105, with sensitivity = 69.9% and specificity = 75.8%. Increment in model performance resulting from adding SIIRI versus other inflammatory indices was assessed using discrimination, calibration, and goodness-of-fit measures. When added to a baseline model, the SIIRI resulted in a significant increase in the c-statistic and significant net reclassification index (.808, P < .0001) and integrated discrimination index (.129, P < .0001), and a decrease in Akaike and Bayesian information criteria.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Humans , Acute Coronary Syndrome/diagnosis , Bayes Theorem , Blood Platelets , Inflammation/diagnosis , Retrospective Studies
2.
Catheter Cardiovasc Interv ; 103(1): 51-60, 2024 01.
Article in English | MEDLINE | ID: mdl-37994226

ABSTRACT

BACKGROUND: Among the two stent strategies, contemporary evidence favors double kissing crush technique (DKC) for complex unprotected distal left main bifurcation (UdLMB) lesions. However one of the major challenges to these lesions is side branch (SB) restenosis. AIMS: Our aim was to identify optical coherence tomographic (OCT) characteristics that may predict SB restenosis (SBR) after UdLMB angioplasty using DKC technique. METHODS: This was a single-center, retrospective study that included 60 patients with complex UdLMB disease, who underwent OCT-guided angioplasty using DKC technique. Angiographic follow-up was performed in all patients at 1 year to identify patients with SBR. Patients with SBR group were compared with patients without SBR (NSBR group) for OCT parameters during index procedure. RESULTS: Twelve (20%) patients developed SBR at 1-year follow-up. The SBR group had longer SB lesion (18.8 ± 3.2 vs. 15.3 ± 3.7 mm, p = 0.004) and neo-metallic carinal length (2.1 vs. 0.1 mm, p < 0.001) when compared to the NSBR group. Longer neo-metallic carinal length was associated with the absence of the dumbbell sign, presence of hanging stent struts across the SB ostium on OCT of final MB pullback. On multivariate regression analysis, SB distal reference diameter (DRD) and SB stent expansion were identified as independent predictors of SBR with SB-DRD of ≤2.8 mm (area under curve-0.73, sensitivity-83.3%, and specificity-62.5%) and SB stent expansion of ≤89% (area under curve-0.88, sensitivity-83.3%, and specificity- 81.2%) as the best cut off values to predict SBR. CONCLUSIONS: SB DRD and SB stent expansion are the OCT predictors of future SBR after UdLMB angioplasty using DKC technique.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Drug-Eluting Stents , Heart Valve Diseases , Humans , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Retrospective Studies , Tomography, Optical Coherence , Treatment Outcome , Coronary Artery Disease/therapy , Coronary Artery Disease/surgery , Stents , Constriction, Pathologic , Coronary Angiography/methods
3.
Cardiovasc Revasc Med ; 34: 86-91, 2022 01.
Article in English | MEDLINE | ID: mdl-33468422

ABSTRACT

OBJECTIVES: To do a quantitative comparison of saline and contrast Frequency domain optical coherence tomography (FD-OCT) during percutaneous coronary intervention (PCI) optimisation. METHODS: 13 pairs of OCT runs were analysed, wherein each pair consisted of a contrast run and a heparinized saline run taken in the same coronary artery at the same position. Quantitative analysis was done comparing minimal lumen area (MLA), proximal reference diameter (PRD), distal reference diameter (DRD) and percentage area stenosis (AS) at the same anatomical location. Lesion morphologies, rendered stent view and 3D reconstruction were compared for image clarity. RESULT: The saline OCT runs resulted in comparable MLA (3.88 ± 2.59 mm2 with saline run vs 3.88 ± 2.71 mm2 with contrast run; p = 0.650), PRD (3.66 ± 0.52 mm with saline vs 3.65 ± 0.52 mm with contrast; p = 0.463), DRD (2.97 ± 0.22 mm with saline vs 2.99 ± 0.88 mm with contrast; p = 0.433), and AS (59.60 ± 18.62% with saline vs 59.18 ± 19.11% with contrast; p = 0.753) with respect to the contrast runs. The Bland Altman plots of the measured parameters indicate good agreement between saline and contrast OCT. Linear regression analysis indicated the absence of proportional bias All lesion morphologies (calcified, fibrotic, thin cap fibroatheroma, macrophages, cholesterol crystals and edge dissection), 3D reconstruction and rendered stent view were clearly demonstrable in the saline OCT runs. CONCLUSIONS: Using heparinized saline as flushing media in coronary FD-OCT may result in vessel dimensions that are comparable with contrast. Heparinized saline may be used as a contrast saving alternative for FD-OCT during PCI optimization.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Constriction, Pathologic , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Humans , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Prospective Studies , Tomography, Optical Coherence , Treatment Outcome
4.
Front Cardiovasc Med ; 8: 625873, 2021.
Article in English | MEDLINE | ID: mdl-33634171

ABSTRACT

Objectives: In this study, we intend to analyze the feasibility and efficacy of very low frame rate fluoroscopy (VLFF) protocol using a combination of 3.8 and 7.5 fps while performing Percutaneous Coronary Intervention (PCI). Methods: A retrospective cohort including 193 patients undergoing PCI under the VLFF protocol (Post-VLFF group) was compared with a retrospective cohort of 133 patients, who underwent PCI prior to implementation of VLFF protocol (Pre-VLFF group). In the Pre-VLFF group, all PCIs were performed using fluoroscopy frame rate of 15 fps. In the Post-VLFF group, 3.8 fps was used to guide catheter engagement, coronary lesion wiring, pre-and post-dilation, and 7.5 fps was used for lesion assessment and stent placement. Increasing use of fluoroscopic storage in place of cineangiography was also encouraged. Cine acquisition in both groups was performed at 15 fps. Primary endpoint was radiation exposure measured by Air Kerma. Secondary endpoints were procedure related outcomes and patient related outcomes (Major Adverse Cardiac Events including all-cause mortality, Target Lesion Failure, Myocardial Infarction, and Stroke). RESULTS: Post-VLFF group showed 74.7% reduction in Air Kerma as compared to Pre-VLFF group (433 ± 27 mGy vs. 1,714 ± 140 mGy; p < 0.0001), with no increase in the fluoroscopy time (15.38 ± 0.98 min Post-VLFF vs. 17.06 ± 1.29 min Pre-VLFF; p = 0.529) and contrast volume (116.5 ± 4.9 ml Post-VLFF vs. 116.7 ± 6 ml Pre-VLFF; p = 0.700). Both groups had comparable procedural success and complications rates as well as incidence of MACE. Conclusions: The very low frame rate fluoroscopy protocol is a feasible, effective, and safe method to significantly reduce the radiation exposure during PCI without any compromise on procedural and patient outcomes.

5.
Indian Heart J ; 72(4): 239-243, 2020.
Article in English | MEDLINE | ID: mdl-32861376

ABSTRACT

AIM: The aim of this study was to evaluate the feasibility of heparinised saline as flushing media for frequency-domain optical coherence tomography (FD-OCT) image acquisition during percutaneous coronary intervention (PCI) optimisation. METHODS AND RESULTS: Twenty-seven patients undergoing FD-OCT-guided PCI were enrolled. Heparinised saline was injected into the coronary during FD-OCT image acquisition. A total of 118 runs were analysed for image quality and diagnostic value. FD-OCT runs were categorised as follows: good runs (GRs), clinically usable runs (CURs) and clinically not usable runs (NURs); GRs and CURs were combined as clinically effective runs (ERs). Saline FD-OCT enabled visualisation of all possible coronary lesions. Of the 118 runs analysed, 61%, 27.1%, 11.9% and 88.1% were GRs, CURs, NURs and ERs, respectively. Sixty-one percent of total runs were left coronary system (LCS) and 39% were right coronary system (RCS) runs. Among LCS runs, 55.6%, 30.6%, 13.8% and 86.2% were GRs, CURs, NURs and ERs, respectively. Among RCS runs, 69.6%, 21.7%, 8.7% and 91.3% were GRs, CURs, NURs and ERs, respectively. CONCLUSION: This is the first study to demonstrate the technical feasibility of isolated saline FD-OCT for PCI optimisation.


Subject(s)
Coronary Artery Disease/surgery , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention/methods , Saline Solution/pharmacology , Surgery, Computer-Assisted/methods , Tomography, Optical Coherence/methods , Coronary Artery Disease/diagnosis , Coronary Vessels/surgery , Humans , Predictive Value of Tests , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...