Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(2)2023 Jan 11.
Article in English | MEDLINE | ID: mdl-36679623

ABSTRACT

Micro electro-mechanical systems (MEMS) are used to record training and match play of intermittent team sport athletes. Paired with estimates of internal responses or adaptations to exercise, practitioners gain insight into players' dose-response relationship which facilitates the prescription of the training stimuli to optimize performance, prevent injuries, and to guide rehabilitation processes. A systematic review on the relationship between external, wearable-based, and internal parameters in team sport athletes, compliant with the PRISMA guidelines, was conducted. The literature research was performed from earliest record to 1 September 2020 using the databases PubMed, Web of Science, CINAHL, and SportDISCUS. A total of 66 full-text articles were reviewed encompassing 1541 athletes. About 109 different relationships between variables have been reviewed. The most investigated relationship across sports was found between (session) rating of perceived exertion ((session-)RPE) and PlayerLoad™ (PL) with, predominantly, moderate to strong associations (r = 0.49-0.84). Relationships between internal parameters and highly dynamic, anaerobic movements were heterogenous. Relationships between average heart rate (HR), Edward's and Banister's training impulse (TRIMP) seem to be reflected in parameters of overall activity such as PL and TD for running-intensive team sports. PL may further be suitable to estimate the overall subjective perception. To identify high fine-structured loading-relative to a certain type of sport-more specific measures and devices are needed. Individualization of parameters could be helpful to enhance practicality.


Subject(s)
Running , Wearable Electronic Devices , Humans , Physical Exertion/physiology , Athletes , Running/physiology , Team Sports
2.
Sensors (Basel) ; 19(16)2019 Aug 07.
Article in English | MEDLINE | ID: mdl-31394885

ABSTRACT

The aim of this study was to determine possible influences, including data processing and sport-specific demands, on the validity of acceleration measures by an inertial measurement unit (IMU) in indoor environments. IMU outputs were compared to a three-dimensional (3D) motion analysis (MA) system and processed with two sensor fusion algorithms (Kalman filter, KF; Complementary filter, CF) at temporal resolutions of 100, 10, and 5 Hz. Athletes performed six team sport-specific movements whilst wearing a single IMU. Mean and peak acceleration magnitudes were analyzed. Over all trials (n = 1093), KF data overestimated MA resultant acceleration by 0.42 ± 0.31 m∙s-2 for mean and 4.18 ± 3.68 m∙s-2 for peak values, while CF processing showed errors of up to 0.57 ± 0.41 m∙s-2 and -2.31 ± 2.25 m∙s-2, respectively. Resampling to 5 Hz decreased the absolute error by about 14% for mean and 56% for peak values. Still, higher acceleration magnitudes led to a large increase in error. These results indicate that IMUs can be used for assessing accelerations in indoor team sports with acceptable means. Application of a CF and resampling to 5 Hz is recommended. High-acceleration magnitudes impair validity to a large degree and should be interpreted with caution.

3.
Front Physiol ; 9: 141, 2018.
Article in English | MEDLINE | ID: mdl-29535641

ABSTRACT

The increasing interest in assessing physical demands in team sports has led to the development of multiple sports related monitoring systems. Due to technical limitations, these systems primarily could be applied to outdoor sports, whereas an equivalent indoor locomotion analysis is not established yet. Technological development of inertial measurement units (IMU) broadens the possibilities for player monitoring and enables the quantification of locomotor movements in indoor environments. The aim of the current study was to validate an IMU measuring by determining average and peak human acceleration under indoor conditions in team sport specific movements. Data of a single wearable tracking device including an IMU (Optimeye S5, Catapult Sports, Melbourne, Australia) were compared to the results of a 3D motion analysis (MA) system (Vicon Motion Systems, Oxford, UK) during selected standardized movement simulations in an indoor laboratory (n = 56). A low-pass filtering method for gravity correction (LF) and two sensor fusion algorithms for orientation estimation [Complementary Filter (CF), Kalman-Filter (KF)] were implemented and compared with MA system data. Significant differences (p < 0.05) were found between LF and MA data but not between sensor fusion algorithms and MA. Higher precision and lower relative errors were found for CF (RMSE = 0.05; CV = 2.6%) and KF (RMSE = 0.15; CV = 3.8%) both compared to the LF method (RMSE = 1.14; CV = 47.6%) regarding the magnitude of the resulting vector and strongly emphasize the implementation of orientation estimation to accurately describe human acceleration. Comparing both sensor fusion algorithms, CF revealed slightly lower errors than KF and additionally provided valuable information about positive and negative acceleration values in all three movement planes with moderate to good validity (CV = 3.9 - 17.8%). Compared to x- and y-axis superior results were found for the z-axis. These findings demonstrate that IMU-based wearable tracking devices can successfully be applied for athlete monitoring in indoor team sports and provide potential to accurately quantify accelerations and decelerations in all three orthogonal axes with acceptable validity. An increase in accuracy taking magnetometers in account should be specifically pursued by future research.

4.
PLoS One ; 12(7): e0181781, 2017.
Article in English | MEDLINE | ID: mdl-28742832

ABSTRACT

The relationship between the time duration of movement (t(dur)) and related maximum possible power output has been studied and modeled under many conditions. Inspired by the so-called power profiles known for discontinuous endurance sports like cycling, and the critical power concept of Monod and Scherrer, the aim of this study was to evaluate the numerical characteristics of the function between maximum horizontal movement velocity (HSpeed) and t(dur) in soccer. To evaluate this relationship, GPS data from 38 healthy soccer players and 82 game participations (≥30 min active playtime) were used to select maximum HSpeed for 21 distinct t(dur) values (between 0.3 s and 2,700 s) based on moving medians with an incremental t(dur) window-size. As a result, the relationship between HSpeed and Log(t(dur)) appeared reproducibly as a sigmoidal decay function, and could be fitted to a five-parameter equation with upper and lower asymptotes, and an inflection point, power and decrease rate. Thus, the first three parameters described individual characteristics if evaluated using mixed-model analysis. This study shows for the first time the general numerical relationship between t(dur) and HSpeed in soccer games. In contrast to former descriptions that have evaluated speed against power, HSpeed against t(dur) always yields a sigmoidal shape with a new upper asymptote. The evaluated curve fit potentially describes the maximum moving speed of individual players during the game, and allows for concise interpretations of the functional state of team sports athletes.


Subject(s)
Movement/physiology , Soccer/physiology , Walking Speed/physiology , Adolescent , Athletic Performance/physiology , Female , Humans , Male , Running/physiology , Video Recording , Young Adult
5.
J Sports Sci ; 34(9): 787-93, 2016.
Article in English | MEDLINE | ID: mdl-26190229

ABSTRACT

The aim of this study was to evaluate the predictive potential provided by two ventilatory inflection points (VIP1 and VIP2) examined in field without using gas analysis systems and uncomfortable facemasks. A calibrated respiratory inductance plethysmograph (RIP) and a computerised routine were utilised, respectively, to derive ventilation and to detect VIP1 and VIP2 during a standardised field ramp test on a 400 m running track on 81 participants. In addition, average running speed of a competitive 1000 m run (S1k) was observed as criterion. The predictive value of running speed at VIP1 (SVIP1) and the speed range between VIP1 and VIP2 in relation to VIP2 (VIPSPAN) was analysed via regression analysis. VIPSPAN rather than running speed at VIP2 (SVIP2) was operationalised as a predictor to consider the covariance between SVIP1 and SVIP2. SVIP1 and VIPSPAN, respectively, provided 58.9% and 22.9% of explained variance in regard to S1k. Considering covariance, the timing of two ventilatory inflection points provides predictive value in regard to a competitive 1000 m run. This is the first study to apply computerised detection of ventilatory inflection points in a field setting independent on measurements of the respiratory gas exchange and without using any facemasks.


Subject(s)
Respiration , Running/physiology , Adolescent , Adult , Female , Humans , Male , Middle Aged , Plethysmography , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...