Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Int J Cardiovasc Imaging ; 33(12): 1921-1929, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28664480

ABSTRACT

Asymptomatic paroxysmal atrial fibrillation (PAF) is often assumed to be the cause of cryptogenic ischemic strokes (IS) and transient ischemic attacks (TIA). We examined the usefulness of measures obtained by 2D speckle tracking echocardiography and novel left atrial measurements, in the diagnosis of PAF in patients with IS and TIA. We retrospectively included 205 patients who after acute IS or TIA underwent an echocardiogram in sinus rhythm. Patients were designated as PAF-patients if they had one or more reported incidents of AF before or after their echocardiographic examination. None of the conventional echocardiographic parameters were significantly associated with PAF. Of the speckle tracking measurements, only early diastolic strain rate (0.7±0.2 s-1 vs. 0.8±0.3 s-1, p = 0.048) and global longitudinal displacement (GLD) (3.15 ± 1.40 mm vs. 3.87 ± 1.56 mm, p = 0.007) proved significantly different. Of the left atrial parameters both minimal and maximal left atrium volume divided by left ventricular length (min LAV/LVL and max LAV/LVL, respectively) were significantly impaired (min LAV/LVL: 3.7 ± 2.1 cm2 vs. 2.8 ± 1.11 cm2, p = 0.012; max LAV/LVL: 6.6 ± 3.1 cm2 vs. 5.6 ± 1.7 cm2, p = 0.012). GLD, min max LAV/LVL proved significant after adjustment for age, gender, CHA2DS2-VASc and NIHSS. By combining information regarding age, GLD, min and max LAV/LVL the diagnostic accuracy of PAF improved, resulting in a significantly increased area under the curve (p = 0.037). In patients with IS and TIA GLD, min and max LAV/LVL were independently associated with the presence of PAF.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Function, Left , Brain Ischemia/etiology , Echocardiography/methods , Heart Atria/diagnostic imaging , Heart Ventricles/diagnostic imaging , Ischemic Attack, Transient/etiology , Stroke/etiology , Ventricular Function, Left , Adult , Aged , Aged, 80 and over , Area Under Curve , Atrial Fibrillation/complications , Atrial Fibrillation/physiopathology , Brain Ischemia/diagnosis , Brain Ischemia/physiopathology , Female , Heart Atria/physiopathology , Heart Ventricles/physiopathology , Humans , Image Interpretation, Computer-Assisted , Ischemic Attack, Transient/diagnosis , Ischemic Attack, Transient/physiopathology , Male , Middle Aged , Predictive Value of Tests , ROC Curve , Registries , Reproducibility of Results , Retrospective Studies , Risk Factors , Stroke/diagnosis , Stroke/physiopathology
2.
Am J Cardiol ; 117(1): 91-9, 2016 Jan 01.
Article in English | MEDLINE | ID: mdl-26525212

ABSTRACT

Twenty-five to 35 percentage of stroke cases are cryptogenic, and it has been demonstrated that paroxysmal atrial fibrillation (AF) is the causal agent in up to 25% of these incidents. The purpose of this study was to investigate if left atrial (LA) parameters have value for diagnosing paroxysmal AF in patients with ischemic stroke (IS) and transient ischemic attack (TIA). We retrospectively analyzed 219 patients who after acute IS or TIA underwent a transthoracic echocardiographic examination. Patients were designated as patients with paroxysmal AF if they had one or more reported incidents of AF before or after their echocardiographic examination. Patients in the paroxysmal AF group were significantly older and had higher CHA2DS2-VASc score than patients without paroxysmal AF (p <0.05 for both). None of the conventional echocardiographic parameters were significantly associated with paroxysmal AF. However, the atrial measurements evaluating LA function (min LA volume and LA emptying fraction) were significantly different (LA emptying fraction: 45% ± 10% vs 50% ± 10%, p = 0.004; minimal LA volume: 30.2 ml ± 17.3 ml vs 24 ml ± 10 ml, p = 0.035 in patients with paroxysmal AF, even after adjustment for age, gender, CHA2DS2-VASc score, and stroke severity [p <0.05 for both]). By combining the cut-off values of age, LA emptying fraction, and minimal LA volume the diagnostic accuracy of paroxysmal AF was improved, resulting in a sensitivity of 95% and negative predictive value of 97%. In conclusion, in patients with IS and TIA, LA function measurements (minimal LA volume and LA emptying fraction) are independently associated with paroxysmal AF and may improve risk stratification for paroxysmal AF presence after IS or TIA.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Function, Left/physiology , Brain Ischemia/etiology , Echocardiography, Doppler, Pulsed/methods , Ischemic Attack, Transient/etiology , Tachycardia, Paroxysmal/diagnostic imaging , Atrial Fibrillation/complications , Atrial Fibrillation/physiopathology , Electrocardiography , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Risk Factors , Tachycardia, Paroxysmal/complications , Tachycardia, Paroxysmal/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...