Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 79
Filter
1.
Eur J Heart Fail ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726573

ABSTRACT

AIM: This analysis aimed to compare the clinical outcomes associated with heart failure (HF) readmissions and to identify associations with HF hospitalizations (HFH) in patients treated with the MitraClip™ NTR/XTR System in the EXPAND study. METHODS AND RESULTS: The global, real-world EXPAND study enrolled 1041 patients with primary or secondary mitral regurgitation (MR) treated with the MitraClip NTR/XTR System. Echocardiograms were analysed by an independent echocardiographic core laboratory. The study population was stratified into HFH and No-HFH groups based on the occurrence of HFH 1 year post-index procedure. Clinical outcomes including MR severity, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ) score, and all-cause mortality were compared (HFH: n = 181; No-HFH: n = 860). Both groups achieved consistent 1-year MR reduction to ≤1+ (HFH vs. No-HFH: 87.3% vs. 89.5%, p = 0.6) and significant 1-year improvement in KCCQ scores (+16.5 vs. +22.3, p = 0.09) and NYHA functional class. However, more patients in the No-HFH group had 1-year NYHA class ≤II (HFH vs. No-HFH: 67.9% vs. 81.9%, p < 0.01). All-cause mortality at 1 year was 36.8% in the HFH group versus 10.4% in the No-HFH group (p < 0.001). The HFH rate decreased by 63% at 1 year post-M-TEER versus 1 year pre-treatment (relative risk 0.4, p < 0.001). Independent HFH associations were MR ≥2+ at discharge, HFH 1 year prior to treatment, baseline NYHA class ≥III, baseline tricuspid regurgitation ≥2+, and baseline left ventricular ejection fraction ≤40%. CONCLUSIONS: This study reports the impact of HFH on clinical outcomes post-treatment in the EXPAND study. Results demonstrate that the occurrence of HFH was associated with worse 1-year survival, and treatment with the MitraClip system substantially reduced HFH and improved patient symptoms and quality of life.

2.
N Engl J Med ; 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38587261

ABSTRACT

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).

3.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38573257

ABSTRACT

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Postoperative Complications , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Postoperative Complications/surgery , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Incidence , Retreatment
4.
Article in English | MEDLINE | ID: mdl-38599918

ABSTRACT

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

5.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599690

ABSTRACT

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
6.
Photochem Photobiol ; 100(1): 137-145, 2024.
Article in English | MEDLINE | ID: mdl-37029739

ABSTRACT

Far-UVC, from filtered Krypton-Chloride lamps, is promising for reducing airborne transmission of disease. While significant research has been undertaken to investigate skin safety of these lamps, less work has been undertaken on eye safety. There is limited data on human eye safety or discomfort from the deployment of this germicidal technology. In this pilot study, immediate and delayed eye discomfort were assessed in a simulated office environment with deployment of Krypton-Chloride lamps, located on the ceiling and directed downwards into the occupied room. Discomfort was assessed immediately postexposure and several days after exposure using validated, Standard Patient Evaluation Eye Dryness (SPEED) and Ocular Surface Disease Index (OSDI) questionnaires. Our results show no significant eye discomfort or adverse effects from the deployment of Far-UVC in this simulated office environment, even when lamps were operated continuously with participants receiving head exposures of up to 50 mJ cm-2 . In addition, a statistically significant reduction in bacteria and fungi of 52% was observed. Far-UVC in this simulated office environment did not cause any clinically significant eye discomfort and was effective at reducing pathogens in the room. These results contribute an important step to further investigation of the interaction of Far-UVC with the human eye.


Subject(s)
Chlorides , Ultraviolet Rays , Humans , Krypton , Pilot Projects , Skin/microbiology , Disinfection/methods
7.
Article in English | MEDLINE | ID: mdl-37962288

ABSTRACT

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

8.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Article in English | MEDLINE | ID: mdl-37988439

ABSTRACT

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Feasibility Studies , Treatment Outcome , Tomography, X-Ray Computed , Prosthesis Design
9.
Photochem Photobiol ; 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37929787

ABSTRACT

The COVID-19 pandemic underscored the crucial importance of enhanced indoor air quality control measures to mitigate the spread of respiratory pathogens. Far-UVC is a type of germicidal ultraviolet technology, with wavelengths between 200 and 235 nm, that has emerged as a highly promising approach for indoor air disinfection. Due to its enhanced safety compared to conventional 254 nm upper-room germicidal systems, far-UVC allows for whole-room direct exposure of occupied spaces, potentially offering greater efficacy, since the total room air is constantly treated. While current evidence supports using far-UVC systems within existing guidelines, understanding the upper safety limit is critical to maximizing its effectiveness, particularly for the acute phase of a pandemic or epidemic when greater protection may be needed. This review article summarizes the substantial present knowledge on far-UVC safety regarding skin and eye exposure and highlights research priorities to discern the maximum exposure levels that avoid adverse effects. We advocate for comprehensive safety studies that explore potential mechanisms of harm, generate action spectra for crucial biological effects and conduct high-dose, long-term exposure trials. Such rigorous scientific investigation will be key to determining safe and effective levels for far-UVC deployment in indoor environments, contributing significantly to future pandemic preparedness and response.

10.
JTCVS Tech ; 21: 45-55, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37854813

ABSTRACT

Transaxillary access has been the most frequently used nonfemoral access route for transcatheter aortic valve replacement (TAVR) with a self-expanding valve. Use of transcarotid TAVR is increasing; however, comparative data on these methods are limited. We compared outcomes following transcarotid or transaxillary TAVR with a self-expanding, supra-annular valve. Methods: The Transcatheter Valve Therapy Registry was queried for TAVR procedures using transaxillary and transcarotid access between July 2015 and June 2021. Patients received a self-expanding Evolut R, PRO, or PRO + valve (Medtronic) and had 1-year follow-up. Thirty-day and 1-year outcomes were compared in transcarotid and transaxillary groups after 1:2 propensity score-matching. Multivariable regression models were fitted to identify predictors of key end points. Results: The propensity score-matched cohort included 576 patients receiving transcarotid and 1142 receiving transaxillary access. Median procedure time (99 vs 118 minutes; P < .001) and hospital stay (2 vs 3 days; P < .001) were shorter with transcarotid versus transaxillary access. At 30 days, patients with transcarotid access had similar mortality (Kaplan-Meier estimates 3.7% vs 4.3%, P = .57) but significantly lower stroke (3.1% vs 5.9%; P = .017) and mortality or stroke (6.0% vs 8.9%; P = .033) compared with patients receiving transaxillary access. Similar differences were observed at 1 year. Transaxillary access was associated with increased risk of 30-day stroke (hazard ratio, 2.14; 95% confidence interval, 1.27-3.58) by multivariable regression analysis. Conclusions: Transcarotid versus transaxillary access for TAVR using a self-expanding valve is associated with procedural benefits and significantly lower stroke and mortality or stroke at 30 days. In patients with unsuitable femoral anatomy, transcarotid access may be the preferred delivery route for self-expanding valves.

11.
JACC Cardiovasc Interv ; 16(21): 2600-2610, 2023 11 13.
Article in English | MEDLINE | ID: mdl-37877913

ABSTRACT

BACKGROUND: The fourth-generation mitral transcatheter edge-to-edge repair (M-TEER) device introduced an improved clip deployment sequence, independent leaflet grasping, and 2 wider clip sizes to tailor the treatment of patients with mitral regurgitation (MR) for a broad range of anatomies. The 30-day safety and effectiveness of the fourth-generation M-TEER device were previously demonstrated. OBJECTIVES: The aim of this study was to evaluate 1-year outcomes in a contemporary, real-world cohort of subjects treated with the MitraClip G4 system. METHODS: EXPAND G4 is an ongoing prospective, multicenter, international, single-arm study that enrolled subjects with primary and secondary MR. One-year outcomes included MR severity (echocardiographic core laboratory assessed), heart failure hospitalization, all-cause mortality, functional capacity (NYHA functional class), and quality of life (Kansas City Cardiomyopathy Questionnaire). RESULTS: A total of 1,164 subjects underwent M-TEER from 2020 to 2022. At 1 year, there was a durable reduction in MR to mild or less in 92.6% and to none or trace in 44.2% (P < 0.0001 vs baseline). Few subjects had major adverse events through 1 year (<2% for myocardial infarction, surgical reintervention, or single-leaflet device attachment). The 1-year Kaplan-Meier estimates for all-cause mortality and heart failure hospitalization were 12.3% and 16.9%. Significant improvements in functional capacity (NYHA functional class I or II in 82%; P < 0.0001 vs baseline) and quality of life (18.5-point Kansas City Cardiomyopathy Questionnaire overall summary score improvement; P < 0.0001) were observed. CONCLUSIONS: M-TEER with the fourth-generation M-TEER device was safe and effective at 1 year, with durable reductions in MR severity to ≤1+ in more than 90% of patients and concomitant improvements in functional status and quality of life.


Subject(s)
Cardiomyopathies , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Quality of Life , Prospective Studies , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
12.
Sci Rep ; 13(1): 16306, 2023 09 28.
Article in English | MEDLINE | ID: mdl-37770588

ABSTRACT

Any potential positive effects conferred via sunlight exposure have to be carefully balanced against carcinogenic effects. Here we provide evidence UK sunlight exposure upregulates the cardio protectant nitric oxide (NO) within in vitro skin cell lines with negligible increases in DNA damage and cell death at 1 SED, when compared against unexposed samples. The whole of the ultraviolet A (UV-A) spectrum appears to be responsible for NO release, with efficiency higher at exposures closer to shorter UV-A wavelengths and decreasing with wavelength increases. These results support further in vivo work, which could be of benefit for demographics such as the elderly (that exhibit a natural decline in NO bioavailability).


Subject(s)
Sunlight , Ultraviolet Rays , Humans , Aged , Nitric Oxide , Cell Survival , DNA Damage
13.
J Am Coll Cardiol ; 82(13): 1281-1297, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37730284

ABSTRACT

BACKGROUND: Real-world applicability of the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) randomized controlled trial (RCT) has been debated because of careful patient selection and the contrasting results of the MITRA-FR (Multicentre Study of Percutaneous Mitral Valve Repair MitraClip Device in Patients with Severe Secondary Mitral Regurgitation) RCT. OBJECTIVES: The COAPT-PAS (COAPT Post-Approval Study) was initiated to assess the safety and effectiveness of the MitraClip in patients with secondary mitral regurgitation (SMR). METHODS: COAPT-PAS is a prospective, single-arm, observational study of 5,000 consecutive patients with SMR treated with the MitraClip at 406 U.S. centers participating in the TVT (Transcatheter Valve Therapy) registry from 2019 to 2020. The 1-year outcomes from the COAPT-PAS full cohort and the COAPT-like and MITRA-FR-like subgroups who met RCT inclusion/exclusion criteria are reported. RESULTS: Patients in the COAPT-PAS had more comorbidities, more severe HF and functional limitations, and less guideline-directed medical therapy than those in the COAPT or MITRA-FR RCTs. Patients in the COAPT-PAS full cohort and the COAPT-like (n = 991) and MITRA-FR-like (n = 917) subgroups achieved a 97.7% MitraClip implant rate, a similar and durable reduction of mitral regurgitation to ≤2+ at 1 year (90.7%, 89.7%, and 86.6%, respectively), a large improvement in quality of life at 1 year (Kansas City Cardiomyopathy Questionnaire +29 COAPT-PAS, +27 COAPT-like, and +33 MITRA-FR-like), faster procedure times, similar or lower clinical event rates compared with the RCTs' MitraClip arms, and lower clinical event rates than the RCTs' guideline-directed medical therapy only arms. One-year heart failure hospitalizations was 18.9% in COAPT-PAS, 19.7% in COAPT-like compared with 24.9% in COAPT-RCT, and 28.7% in COAPT-PAS-MITRA-FR-like compared with 47.4% in MITRA-FR-RCT. CONCLUSIONS: This large, contemporary, real-world study reinforces the safety and effectiveness of the MitraClip System in patients with SMR, including those who met the COAPT or MITRA-FR RCT inclusion/exclusion criteria and patients excluded from the RCTs.


Subject(s)
Heart Failure , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Hospitalization , Outcome Assessment, Health Care , Patient Selection
14.
Lancet ; 402(10412): 1529-1540, 2023 10 28.
Article in English | MEDLINE | ID: mdl-37660719

ABSTRACT

BACKGROUND: With increasing numbers of patients undergoing transcatheter aortic valve replacement (TAVR), data on management of failed TAVR, including repeat TAVR procedure, are needed. The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry. METHODS: This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9, 2011, to Dec 30, 2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves (redo-TAVR) or native aortic valves (native-TAVR). Procedural, echocardiographic, and clinical outcomes were compared between redo-TAVR and native-TAVR cohorts using propensity score matching. FINDINGS: Among 350 591 patients (1320 redo-TAVR; 349 271 native-TAVR), 1320 propensity-matched pairs of patients undergoing redo-TAVR and native-TAVR were analysed (redo-TAVR cohort: mean age 78 years [SD 9]; 559 [42·3%] of 1320 female, 761 [57·7%] male; mean predicted surgical risk of 30-day mortality 8·1%). The rates of procedural complications of redo-TAVR were low (coronary compression or obstruction: four [0·3%] of 1320; intraprocedural death: eight [0·6%] of 1320; conversion to open heart surgery: six [0·5%] of 1319) and similar to native-TAVR. There was no significant difference between redo-TAVR and native-TAVR populations in death at 30 days (4·7% vs 4·0%, p=0·36) or 1 year (17·5% vs 19·0%, p=0·57), and stroke at 30 days (2·0% vs 1·9%, p=0·84) or 1 year (3·2% vs 3·5%, p=0·80). Redo-TAVR reduced aortic valve gradients at 1 year, although they were higher in the redo-TAVR group compared with the native-TAVR group (15 mm Hg vs 12 mm Hg; p<0·0001). Moderate or severe aortic regurgitation rates were similar between redo-TAVR and native-TAVR groups at 1 year (1·8% vs 3·3%, p=0·18). Death or stroke after redo-TAVR were not significantly affected by the timing of redo-TAVR (before or after 1 year of index TAVR), or by index transcatheter valve type (balloon-expandable or non-balloon-expandable). INTERPRETATION: Redo-TAVR with balloon-expandable valves effectively treated dysfunction of the index TAVR procedure with low procedural complication rates, and death and stroke rates similar to those in patients with a similar clinical profile and predicted risk undergoing TAVR for native aortic valve stenosis. Redo-TAVR with balloon-expandable valves might be a reasonable treatment for failed TAVR in selected patients. FUNDING: Edwards Lifesciences.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Aged , Transcatheter Aortic Valve Replacement/methods , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Stroke/etiology , Registries , Risk Factors , Prosthesis Design
15.
JACC Cardiovasc Interv ; 16(12): 1463-1473, 2023 06 26.
Article in English | MEDLINE | ID: mdl-37380228

ABSTRACT

BACKGROUND: The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence. OBJECTIVES: The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting. METHODS: EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality. RESULTS: In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 ± 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR ≤ 2+, and 91% achieved MR ≤ 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days. CONCLUSIONS: This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting.


Subject(s)
Cardiomyopathies , Mitral Valve Insufficiency , Humans , Prospective Studies , Quality of Life , Treatment Outcome , Echocardiography , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
16.
JACC Cardiovasc Interv ; 16(12): 1474-1485, 2023 06 26.
Article in English | MEDLINE | ID: mdl-37380229

ABSTRACT

BACKGROUND: Anatomical and clinical criteria to define mitral transcatheter edge-to-edge repair (TEER) "unsuitability" have been proposed on the basis of a Heart Valve Collaboratory consensus opinion from physician experience with early-generation TEER devices but lacked an evidence-based approach. OBJECTIVES: The aim of this study was to explore the spectrum of TEER suitability using echocardiographic and clinical outcomes from the EXPAND G4 real-world postapproval study. METHODS: EXPAND G4 is a global, prospective, multicenter, single-arm study that enrolled 1,164 subjects with mitral regurgitation (MR) treated with the MitraClip G4 System. Three groups were defined using the Heart Valve Collaboratory TEER unsuitability criteria: 1) risk of stenosis (RoS); 2) risk of inadequate MR reduction (RoIR); and 3) subjects with baseline moderate or less MR (MMR). A TEER-suitable (TS) group was defined by the absence of these characteristics. Endpoints included independent core laboratory-assessed echocardiographic characteristics, procedural outcomes, MR reduction, NYHA functional class, Kansas City Cardiomyopathy Questionnaire score, and major adverse events through 30 days. RESULTS: Subjects in the RoS (n = 56), RoIR (n = 54), MMR (n = 326), and TS (n = 303) groups had high 30-day MR reduction rates (≤1+: RoS 97%, MMR 93%, and TS 91%; ≤2+: RoIR 94%). Thirty-day improvements in functional capacity (NYHA functional class I or II at 30 days vs baseline: RoS 94% vs 29%, RoIR 88% vs 30%, MMR 79% vs 26%, and TS 83% vs 33%) and quality of life (change in Kansas City Cardiomyopathy Questionnaire score: RoS +27 ± 26, RoIR +16 ± 26, MMR +19 ± 26, and TS +19 ± 24) were safely achieved in all groups, with low major adverse events (<3%) and all-cause mortality (RoS 1.8%, RoIR 0%, MMR 1.5%, and TS 1.3%). CONCLUSIONS: Patients previously deemed TEER unsuitable can be safely and effectively treated with the mitral TEER fourth-generation device.


Subject(s)
Cardiomyopathies , Mitral Valve Insufficiency , Humans , Prospective Studies , Quality of Life , Reactive Oxygen Species , Treatment Outcome , Constriction, Pathologic , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery
17.
JACC Cardiovasc Interv ; 16(8): 885-895, 2023 04 24.
Article in English | MEDLINE | ID: mdl-37100552

ABSTRACT

An increasing number of patients with mitral valve disease are high risk for surgery and in need of less invasive treatments including transcatheter mitral valve replacement (TMVR). Left ventricular outflow tract (LVOT) obstruction is a predictor of poor outcome after TMVR, and its risk can be accurately predicted using cardiac computed tomography analysis. Novel treatment strategies that have shown efficacy in reducing risk of LVOT obstruction after TMVR include pre-emptive alcohol septal ablation, radiofrequency ablation, and anterior leaflet electrosurgical laceration. This review describes recent advances in the management of LVOT obstruction risk after TMVR, provides a new management algorithm, and explores forthcoming studies that will further advance the field.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Ventricular Outflow Obstruction, Left , Ventricular Outflow Obstruction , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Treatment Outcome
18.
JACC Cardiovasc Interv ; 16(6): 681-689, 2023 03 27.
Article in English | MEDLINE | ID: mdl-36990558

ABSTRACT

BACKGROUND: The self-expanding, intra-annular Navitor (Abbott Structural Heart) valve includes an outer cuff to reduce paravalvular leak (PVL) and large stent cells for future coronary access. OBJECTIVES: The purpose of the PORTICO NG (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis) study is to evaluate the safety and effectiveness of the Navitor valve in patients with symptomatic, severe aortic stenosis who are at high or extreme surgical risk. METHODS: PORTICO NG is a prospective, multicenter, global study with follow-up at 30 days, 1 year, and annually through 5 years. The primary endpoints are all-cause mortality and moderate or greater PVL at 30 days. Valve Academic Research Consortium-2 events and valve performance are assessed by an independent clinical events committee and echocardiographic core laboratory. RESULTS: A total of 260 subjects were treated at 26 clinical sites across Europe, Australia, and the United States between September 2019 and August 2022. The mean age was 83.4 ± 5.4 years, 57.3% were female, and the average Society of Thoracic Surgeons score was 3.9% ± 2.1%. At 30 days, the rate of all-cause mortality was 1.9%, and no subjects had moderate or greater PVL. The rate of disabling stroke was 1.9%, life-threatening bleeding was 3.8%, stage 3 acute kidney injury was 0.8%, major vascular complications were 4.2%, and new permanent pacemaker implantation was 19.0%. Hemodynamic performance included a mean gradient of 7.4 ± 3.5 mm Hg and an effective orifice area of 2.00 ± 0.47 cm2. CONCLUSIONS: The Navitor valve is safe and effective for the treatment of subjects with severe aortic stenosis who are at high or greater risk for surgery, which is supported by low rates of adverse events and PVL. (Evaluation of the Portico NG [Next Generation] Transcatheter Aortic Valve in High and Extreme Risk Patients With Symptomatic Severe Aortic Stenosis [PORTICO NG]; NCT04011722).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , United States , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Treatment Outcome , Postoperative Complications/etiology , Heart Valve Prosthesis/adverse effects , Prosthesis Design
19.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36922042

ABSTRACT

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , United States , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Critical Pathways , Prospective Studies , Risk Factors , Treatment Outcome , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis/adverse effects
20.
JACC Cardiovasc Interv ; 16(5): 589-602, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36922046

ABSTRACT

BACKGROUND: The third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system was introduced to assist in leaflet grasping with the longer clip arms of MitraClip XTR and to improve ease of use with the modified delivery catheter. OBJECTIVES: The EXPAND study evaluated contemporary real-world outcomes in subjects with mitral regurgitation (MR) treated with the third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system. METHODS: EXPAND is a prospective, multicenter, international, single-arm study that enrolled patients with primary MR and secondary MR at 57 centers. Follow-up was conducted through 12 months. Echocardiograms were analyzed by an echocardiographic core laboratories. Study outcomes included: MR severity, functional capacity measured by New York Heart Association functional class, quality of life measured by Kansas City Cardiomyopathy Questionnaire, heart failure hospitalizations, all-cause mortality. RESULTS: 1,041 patients were enrolled from April 2018 through March 2019, of which 50.5% had primary or mixed etiology. Implant success was 98.9%; 1.5 ± 0.6 clips were implanted per subject. Significant MR reduction from baseline (≥MR 3+: 56.0%) to 30 days (≤MR 1+:88.8%) was maintained through 1 year (MR ≤1+: 89.2%). A total of 84.5% and 93.0% of subjects in primary MR and secondary MR, respectively, had ≤1+ MR at 1 year. Significant improvements were observed in clinical outcomes (New York Heart Association functional class I/II in 80.3%, +21.6 improvement in Kansas City Cardiomyopathy Questionnaire score) at 1 year. All-cause mortality and heart failure hospitalizations at 1 year were 14.9% and 18.9%, respectively, which was significantly lower than previous studies. CONCLUSIONS: The study demonstrates treatment with the third-generation system resulted in substantial reduction of MR in a contemporary real-world practice, compared with the results of earlier EVEREST and COAPT trials.(The MitraClip® EXPAND Study of the Next Generation of MitraClip® Devices [EXPAND]; NCT03502811).


Subject(s)
Cardiomyopathies , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Quality of Life , Prospective Studies , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Heart Failure/diagnostic imaging , Heart Failure/therapy , Heart Failure/complications , Cardiac Catheterization , Cardiomyopathies/complications
SELECTION OF CITATIONS
SEARCH DETAIL
...