Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Clin Infect Dis ; 78(3): 594-602, 2024 03 20.
Article in English | MEDLINE | ID: mdl-37647517

ABSTRACT

BACKGROUND: To protect healthcare workers (HCWs) from the consequences of disease due to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), it is necessary to understand the risk factors that drive exposure and infection within hospitals. Insufficient consideration of key socioeconomic variables is a limitation of existing studies that can lead to bias and residual confounding of proposed risk factors for infection. METHODS: The Co-STARs study prospectively enrolled 3679 HCWs between April 2020 and September 2020. We used multivariate logistic regression to comprehensively characterize the demographic, occupational, socioeconomic, and environmental risk factors for SARS-CoV-2 seropositivity. RESULTS: After adjusting for key confounders, relative household overcrowding (odds ratio [OR], 1.4 [95% confidence interval {CI}, 1.1-1.9]; P = .006), Black, Black British, Caribbean, or African ethnicity (OR, 1.7 [95% CI, 1.2-2.3]; P = .003), increasing age (ages 50-60 years: OR, 1.8 [95% CI, 1.3-2.4]; P < .001), lack of access to sick pay (OR, 1.8 [95% CI, 1.3-2.4]; P < .001). CONCLUSIONS: Socioeconomic and demographic factors outside the hospital were the main drivers of infection and exposure to SARS-CoV-2 during the first wave of the pandemic in an urban pediatric referral hospital. Overcrowding and out-of-hospital SARS-CoV-2 contact are less amenable to intervention. However, lack of access to sick pay among externally contracted staff is more easily rectifiable. Our findings suggest that providing easier access to sick pay would lead to a decrease in SARS-CoV-2 transmission and potentially that of other infectious diseases in hospital settings. CLINICAL TRIALS REGISTRATION: NCT04380896.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Middle Aged , COVID-19/epidemiology , Demography , Health Personnel , Hospitals , Prospective Studies , Risk Factors , Socioeconomic Factors , United Kingdom/epidemiology , Black People , Caribbean People , African People
2.
Clin Infect Dis ; 74(7): 1220-1229, 2022 04 09.
Article in English | MEDLINE | ID: mdl-34218284

ABSTRACT

BACKGROUND: Antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been shown to neutralize the virus in vitro and prevent disease in animal challenge models on reexposure. However, the current understanding of SARS-CoV-2 humoral dynamics and longevity is conflicting. METHODS: The COVID-19 Staff Testing of Antibody Responses Study (Co-Stars) prospectively enrolled 3679 healthcare workers to comprehensively characterize the kinetics of SARS-CoV-2 spike protein (S), receptor-binding domain, and nucleoprotein (N) antibodies in parallel. Participants screening seropositive had serial monthly serological testing for a maximum of 7 months with the Meso Scale Discovery Assay. Survival analysis determined the proportion of seroreversion, while 2 hierarchical gamma models predicted the upper and lower bounds of long-term antibody trajectory. RESULTS: A total of 1163 monthly samples were provided from 349 seropositive participants. At 200 days after symptoms, >95% of participants had detectable S antibodies, compared with 75% with detectable N antibodies. S antibody was predicted to remain detectable in 95% of participants until 465 days (95% confidence interval, 370-575 days) using a "continuous-decay" model and indefinitely using a "decay-to-plateau" model to account for antibody secretion by long-lived plasma cells. S-antibody titers were correlated strongly with surrogate neutralization in vitro (R2 = 0.72). N antibodies, however, decayed rapidly with a half-life of 60 days (95% confidence interval, 52-68 days). CONCLUSIONS: The Co-Stars data presented here provide evidence for long-term persistence of neutralizing S antibodies. This has important implications for the duration of functional immunity after SARS-CoV-2 infection. In contrast, the rapid decay of N antibodies must be considered in future seroprevalence studies and public health decision-making. This is the first study to establish a mathematical framework capable of predicting long-term humoral dynamics after SARS-CoV-2 infection. CLINICAL TRIALS REGISTRATION: NCT04380896.


Subject(s)
COVID-19 , Spike Glycoprotein, Coronavirus , Antibodies, Neutralizing , Antibodies, Viral , Humans , SARS-CoV-2 , Seroepidemiologic Studies
3.
Transfusion ; 61(10): 2837-2843, 2021 10.
Article in English | MEDLINE | ID: mdl-34342366

ABSTRACT

BACKGROUND: Convalescent plasma (CP) therapy for coronavirus disease (COVID-19) provides virus-neutralizing antibodies that may ameliorate the outcome of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections. The effectiveness of CP likely depends on its antiviral neutralizing potency and is determined using in vitro neutralizing antibody assays. STUDY DESIGN AND METHODS: We evaluated abilities of three immunoassays for anti-spike antibodies (EUROimmun, Ortho, Roche), a pseudotype-based neutralization assay, and two assays that quantify ACE2 binding of spike protein (GenScript and hemagglutination test [HAT]-based assay) to predict neutralizing antibody titers in 113 CP donations. Assay outputs were analyzed through linear regression and calculation of sensitivities and specificities by receiver operator characteristic (ROC) analysis. RESULTS: Median values of plasma samples containing neutralizing antibodies produced conversion factors for assay unitage of ×6.5 (pseudotype), ×19 (GenScript), ×3.4 (HAT assay), ×0.08 (EUROimmun), ×1.64 (Roche), and ×0.10 (Ortho). All selected assays were sufficient in identifying the high titer donations based on ROC analysis; area over curve ranged from 91.7% for HAT and GenScript assay to 95.6% for pseudotype assay. However, their ability to predict the actual neutralizing antibody levels varied substantially as shown by linear regression correlation values (from 0.27 for Ortho to 0.61 for pseudotype assay). DISCUSSION: Overall, the study data demonstrate that all selected assays were effective in identifying donations with high neutralizing antibody levels and are potentially suitable as surrogate assays for donation selection for CP therapy.


Subject(s)
Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19 Serological Testing/methods , Immunoassay/methods , SARS-CoV-2/immunology , COVID-19/therapy , Humans , Immunization, Passive , Neutralization Tests , COVID-19 Serotherapy
4.
J Clin Virol ; 130: 104572, 2020 09.
Article in English | MEDLINE | ID: mdl-32769024

ABSTRACT

BACKGROUND: The emergence of SARS-CoV-2 has led to the development of serological assays that could aid in an understanding of the burden of COVID-19 disease. Many available tests lack rigorous evaluation and therefore results may be misleading. OBJECTIVES: The aim of this study was to assess the performance of a novel multiplexed immunoassay for the simultaneous detection of antibodies against SARS-CoV-2 trimeric spike (S), spike receptor binding domain (RBD), spike N terminal domain and nucleocapsid antigen and a novel pseudo-neutralisation assay. METHODS: A multiplexed solid-phase chemiluminescence assay (Meso Scale Discovery) was evaluated for the simultaneous detection of IgG binding to four SARS-CoV-2 antigens and the quantification of antibody-induced ACE-2 binding inhibition (pseudo-neutralisation assay). Sensitivity was evaluated with a total of 196 COVID-19 serum samples (169 confirmed PCR positive and 27 anti-nucleocapsid IgG positive) from individuals with mild symptomatic or asymptomatic disease. Specificity was evaluated with 194 control serum samples collected from adults prior to December 2019. RESULTS: The specificity and sensitivity of the binding IgG assay was highest for S protein with a specificity of 97.4 % and sensitivity of 96.2 % for samples taken 14 days and 97.9 % for samples taken 21 days following the onset of symptoms. IgG concentration to S and RBD correlated strongly with percentage inhibition measured by the pseudo-neutralisation assay. CONCLUSION: Excellent sensitivity for IgG detection was obtained over 14 days since onset of symptoms for three SARS-CoV-2 antigens (S, RBD and N) in this multiplexed assay which can also measure antibody functionality.


Subject(s)
Antibodies, Viral/blood , Antigens, Viral/immunology , Coronavirus Infections/diagnosis , Immunoassay/methods , Immunoglobulin G/blood , Pneumonia, Viral/diagnosis , Adult , Betacoronavirus , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Coronavirus Infections/immunology , Coronavirus Nucleocapsid Proteins , Female , Humans , Luminescent Measurements/methods , Male , Middle Aged , Nucleocapsid Proteins/immunology , Pandemics , Phosphoproteins , Pneumonia, Viral/immunology , SARS-CoV-2 , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology
5.
Lancet Respir Med ; 8(9): 885-894, 2020 09.
Article in English | MEDLINE | ID: mdl-32717210

ABSTRACT

BACKGROUND: Health-care workers constitute a high-risk population for acquisition of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Capacity for acute diagnosis via PCR testing was limited for individuals with mild to moderate SARS-CoV-2 infection in the early phase of the COVID-19 pandemic and a substantial proportion of health-care workers with suspected infection were not tested. We aimed to investigate the performance of point-of-care and laboratory serology assays and their utility in late case identification, and to estimate SARS-CoV-2 seroprevalence. METHODS: We did a prospective multicentre cohort study between April 8 and June 12, 2020, in two phases. Symptomatic health-care workers with mild to moderate symptoms were eligible to participate 14 days after onset of COVID-19 symptoms, as per the Public Health England (PHE) case definition. Health-care workers were recruited to the asymptomatic cohort if they had not developed PHE-defined COVID-19 symptoms since Dec 1, 2019. In phase 1, two point-of-care lateral flow serological assays, the Onsite CTK Biotech COVID-19 split IgG/IgM Rapid Test (CTK Bitotech, Poway, CA, USA) and the Encode SARS-CoV-2 split IgM/IgG One Step Rapid Test Device (Zhuhai Encode Medical Engineering, Zhuhai, China), were evaluated for performance against a laboratory immunoassay (EDI Novel Coronavirus COVID-19 IgG ELISA kit [Epitope Diagnostics, San Diego, CA, USA]) in 300 samples from health-care workers and 100 pre-COVID-19 negative control samples. In phase 2 (n=6440), serosurveillance was done among 1299 (93·4%) of 1391 health-care workers reporting symptoms, and in a subset of asymptomatic health-care workers (405 [8·0%] of 5049). FINDINGS: There was variation in test performance between the lateral flow serological assays; however, the Encode assay displayed reasonable IgG sensitivity (127 of 136; 93·4% [95% CI 87·8-96·9]) and specificity (99 of 100; 99·0% [94·6-100·0]) among PCR-proven cases and good agreement (282 of 300; 94·0% [91·3-96·7]) with the laboratory immunoassay. By contrast, the Onsite assay had reduced sensitivity (120 of 136; 88·2% [95% CI 81·6-93·1]) and specificity (94 of 100; 94·0% [87·4-97·8]) and agreement (254 of 300; 84·7% [80·6-88·7]). Five (7%) of 70 PCR-positive cases were negative across all assays. Late changes in lateral flow serological assay bands were recorded in 74 (9·3%) of 800 cassettes (35 [8·8%] of 400 Encode assays; 39 [9·8%] of 400 Onsite assays), but only seven (all Onsite assays) of these changes were concordant with the laboratory immunoassay. In phase 2, seroprevalence among the workforce was estimated to be 10·6% (95% CI 7·6-13·6) in asymptomatic health-care workers and 44·7% (42·0-47·4) in symptomatic health-care workers. Seroprevalence across the entire workforce was estimated at 18·0% (95% CI 17·0-18·9). INTERPRETATION: Although a good positive predictive value was observed with both lateral flow serological assays and ELISA, this agreement only occurred if the pre-test probability was modified by a strict clinical case definition. Late development of lateral flow serological assay bands would preclude postal strategies and potentially home testing. Identification of false-negative results among health-care workers across all assays suggest caution in interpretation of IgG results at this stage; for now, testing is perhaps best delivered in a clinical setting, supported by government advice about physical distancing. FUNDING: None.


Subject(s)
Betacoronavirus , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Occupational Diseases/diagnosis , Pneumonia, Viral/diagnosis , Point-of-Care Systems , Adult , COVID-19 , COVID-19 Testing , Coronavirus Infections/epidemiology , Coronavirus Infections/virology , Enzyme-Linked Immunosorbent Assay/statistics & numerical data , Female , Health Personnel , Humans , Immunoassay/statistics & numerical data , Male , Middle Aged , Occupational Diseases/epidemiology , Occupational Diseases/virology , Pandemics , Pneumonia, Viral/epidemiology , Pneumonia, Viral/virology , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , SARS-CoV-2 , Sensitivity and Specificity , Seroepidemiologic Studies , United Kingdom/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...