Radiology ; 237(1): 202-11, 2005 Oct.
Article in English | MEDLINE | ID: mdl-16118150

ABSTRACT

PURPOSE: To prospectively evaluate the elastographic appearance of thyroid gland tumors and explore the potential sensitivity and specificity of ultrasonographic (US) elastography for differentiating benign and malignant tumors, with histopathologic analysis as the reference standard. MATERIALS AND METHODS: The study was institutional review board approved, and each patient gave written informed consent. Fifty-two thyroid gland lesions (22 malignant, 30 benign) in 31 consecutive patients (six men, 25 women; mean age, 49.7 years +/- 14.7 [standard deviation]) were examined with real-time elastography in the elasticity imaging mode implemented on a clinical US scanner modified for research. In addition, the radiofrequency echo data stored during US were exported from the scanner and used for off-line strain image reconstruction. All elastograms were evaluated for the lesion visibility, relative brightness, and margin regularity and definition by using a four-point scale. In addition, normal thyroid gland tissue and thyroid gland tumor strains were measured on off-line processed elastograms, and the thyroid gland-to-tumor strain ratio (ie, strain index) was calculated. The potential of elastographic criteria for the diagnosis of thyroid gland cancer was evaluated with univariate analysis and multivariate logistic regression. Qualitative variables were compared by using the chi2 test, and quantitative variables were compared by using the Mann-Whitney U test. P < .05 was considered to indicate significance. RESULTS: A strain index value greater than 4 on off-line processed elastograms was the strongest independent predictor of thyroid gland malignancy (P < .001); this criterion had 96% specificity and 82% sensitivity. Two other elastographic criteria, which were evaluated on real-time elastograms--a margin regularity score higher than 3 (88% specificity, 36% sensitivity) and a tumor area ratio higher than 1 (92% specificity, 46% sensitivity)--also were associated with malignancy (P < .05). However, the usefulness of these criteria was not considered to be high because of their low sensitivity. CONCLUSION: Elastography is a promising imaging technique that can assist in the differential diagnosis of thyroid cancer.


Subject(s)
Thyroid Neoplasms/diagnostic imaging , Adult , Aged , Biomechanical Phenomena , Cysts/diagnostic imaging , Diagnosis, Differential , Elasticity , Female , Humans , Logistic Models , Male , Middle Aged , Sensitivity and Specificity , Thyroid Diseases/diagnostic imaging , Thyroid Neoplasms/pathology , Ultrasonography
2.
Ultrason Imaging ; 25(3): 171-92, 2003 Jul.
Article in English | MEDLINE | ID: mdl-14870802

ABSTRACT

A recently-developed ultrasonic technique for measuring elastic properties of vascular tissue is evaluated using computer simulations, phantom and in vivo human measurements. A time sequence of displacement images is measured over the cardiac cycle to describe the spatial and temporal patterns of deformation surrounding arteries. This information is combined with a mathematical model to estimate an elastic modulus. Computer simulations of ultrasonic echo data from deformed tissues are analyzed to define a signal processing approach. Measurements in flow phantoms, with and without vessel-simulating channel walls, provide an assessment of the accuracy and precision of this technique for vascular elasticity measurements. Finally, preliminary results for the stiffness index (beta) in a study group of healthy human volunteers are compared with previously reported data. We find that careful measurement technique is required to control measurement variability.


Subject(s)
Blood Vessels/diagnostic imaging , Ultrasonography/methods , Algorithms , Elasticity , Humans , Models, Cardiovascular , Phantoms, Imaging , Signal Processing, Computer-Assisted , Stress, Mechanical
3.
Ultrasound Med Biol ; 28(11-12): 1475-84, 2002.
Article in English | MEDLINE | ID: mdl-12498943

ABSTRACT

A tissue-like gelatin elasticity-flow phantom was examined to develop ultrasonic strain imaging for the detection of internal pulsatile deformations. The same imaging technique was then applied in vivo to monitor deformation in tissues surrounding the normal brachial artery. The results suggest that vascular strain patterns resulting from biologic stimuli are very different from those generated using externally applied stress fields, and are directly related to pressure variations within the vessel. These data suggest a potential role for strain imaging in measuring the relative pressure or vascular elasticity locally and noninvasively.


Subject(s)
Brachial Artery/diagnostic imaging , Brachial Artery/physiology , Pulsatile Flow/physiology , Adult , Algorithms , Elasticity , Humans , Male , Phantoms, Imaging , Pressure , Stress, Mechanical , Ultrasonography