JACC Cardiovasc Interv ; 8(14): 1842-9, 2015 Dec 21.
Article in English | MEDLINE | ID: mdl-26604062

ABSTRACT

OBJECTIVES: This study sought to evaluate the use of the Direct Flow Medical (DFM) transcatheter heart valve (Direct Flow Medical, Santa Rosa, California) for the treatment of noncalcific pure aortic regurgitation (AR). BACKGROUND: The treatment of noncalcific AR has remained a relative contraindication with transcatheter heart valves due to challenges in anchoring devices in the absence of calcium, concerns of valve embolization, and the high risk of significant residual paravalvular leak. METHODS: The study population consisted of patients treated for severe noncalcific pure AR with transfemoral implantation of a DFM transcatheter heart valve at 6 European centers. The primary endpoint was the composite endpoint of device success and the secondary endpoint was the composite early safety endpoint (according to the VARC-2 criteria). RESULTS: Eleven high-risk (STS score 8.84 ± 8.9, Logistic EuroSCORE 19.9 ± 7.1) patients (mean age 74.7 ± 12.9 years) were included. Device success was achieved in all patients. In 1 patient, the initial valve prosthesis was retrieved after pull-through, and a second valve was successfully deployed. The early safety endpoint was reached in 91% of the patients, with 1 patient requiring surgical aortic valve replacement secondary to downward dislocation of the prosthesis that was successfully managed with surgical aortic valve replacement. DFM implantation resulted in excellent hemodynamics with none or trivial paravalvular regurgitation in 9 patients and a transprosthetic gradient of 7.7 ± 5.1 mm Hg at 30-day follow up. All patients derived symptomatic benefit following the procedure, with 72% in New York Heart Association functional class I or II. CONCLUSIONS: This study reports the feasibility of treating severe noncalcific AR with the Direct Flow prosthesis via the transfemoral route.


Subject(s)
Aortic Valve Insufficiency/surgery , Catheterization, Peripheral/methods , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/mortality , Europe/epidemiology , Female , Femoral Artery , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Risk Factors , Survival Rate/trends , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...