Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
J Biomed Opt ; 29(Suppl 2): S22708, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38872791

ABSTRACT

Significance: The ability to observe and monitor cell density and morphology has been imperative for assessing the health of a cell culture and for producing high quality, high yield cell cultures for decades. Microcarrier-based cultures, used for large-scale cellular expansion processes, are not compatible with traditional visualization-based methods, such as widefield microscopy, due to their thickness and material composition. Aim: Here, we assess the optical imaging compatibilities of commercial polystyrene microcarriers versus custom-fabricated gelatin methacryloyl (gelMA) microcarriers for non-destructive and non-invasive visualization of the entire microcarrier surface, direct cell enumeration, and sub-cellular visualization of mesenchymal stem/stromal cells. Approach: Mie scattering and wavefront error simulations of the polystyrene and gelMA microcarriers were performed to assess the potential for elastic scattering-based imaging of adherent cells. A Zeiss Z.1 light-sheet microscope was adapted to perform light-sheet tomography using label-free elastic scattering contrast from planar side illumination to achieve optical sectioning and permit non-invasive and non-destructive, in toto, three-dimensional, high-resolution visualization of cells cultured on microcarriers. Results: The polystyrene microcarrier prevents visualization of cells on the distal half of the microcarrier using either fluorescence or elastic scattering contrast, whereas the gelMA microcarrier allows for high fidelity visualization of cell morphology and quantification of cell density using light-sheet fluorescence microscopy and tomography. Conclusions: The combination of optical-quality gelMA microcarriers and label-free light-sheet tomography will facilitate enhanced control of bioreactor-microcarrier cell culture processes.


Subject(s)
Cell Adhesion , Hydrogels , Mesenchymal Stem Cells , Polystyrenes , Polystyrenes/chemistry , Mesenchymal Stem Cells/cytology , Hydrogels/chemistry , Cell Adhesion/physiology , Optical Imaging/methods , Optical Imaging/instrumentation , Humans , Gelatin/chemistry , Cell Culture Techniques/methods , Cell Culture Techniques/instrumentation , Cells, Cultured , Animals
3.
PLoS One ; 18(3): e0282298, 2023.
Article in English | MEDLINE | ID: mdl-36976801

ABSTRACT

The adoption of cell-based therapies into the clinic will require tremendous large-scale expansion to satisfy future demand, and bioreactor-microcarrier cultures are best suited to meet this challenge. The use of spherical microcarriers, however, precludes in-process visualization and monitoring of cell number, morphology, and culture health. The development of novel expansion methods also motivates the advancement of analytical methods used to characterize these microcarrier cultures. A robust optical imaging and image-analysis assay to non-destructively quantify cell number and cell volume was developed. This method preserves 3D cell morphology and does not require membrane lysing, cellular detachment, or exogenous labeling. Complex cellular networks formed in microcarrier aggregates were imaged and analyzed in toto. Direct cell enumeration of large aggregates was performed in toto for the first time. This assay was successfully applied to monitor cellular growth of mesenchymal stem cells attached to spherical hydrogel microcarriers over time. Elastic scattering and fluorescence lightsheet microscopy were used to quantify cell volume and cell number at varying spatial scales. The presented study motivates the development of on-line optical imaging and image analysis systems for robust, automated, and non-destructive monitoring of bioreactor-microcarrier cell cultures.


Subject(s)
Cell Culture Techniques , Mesenchymal Stem Cells , Humans , Cell Culture Techniques/methods , Cell Culture Techniques, Three Dimensional , Bioreactors , Cell Proliferation
4.
J Biomed Opt ; 27(4)2022 04.
Article in English | MEDLINE | ID: mdl-35478042

ABSTRACT

SIGNIFICANCE: There have been numerous academic and commercial efforts to develop high-resolution in vivo microscopes for a variety of clinical use cases, including early disease detection and surgical guidance. While many high-profile studies, commercialized products, and publications have resulted from these efforts, mainstream clinical adoption has been relatively slow other than for a few clinical applications (e.g., dermatology). AIM: Here, our goals are threefold: (1) to introduce and motivate the need for in vivo microscopy (IVM) as an adjunctive tool for clinical detection, diagnosis, and treatment, (2) to discuss the key translational challenges facing the field, and (3) to propose best practices and recommendations to facilitate clinical adoption. APPROACH: We will provide concrete examples from various clinical domains, such as dermatology, oral/gastrointestinal oncology, and neurosurgery, to reinforce our observations and recommendations. RESULTS: While the incremental improvement and optimization of IVM technologies should and will continue to occur, future translational efforts would benefit from the following: (1) integrating clinical and industry partners upfront to define and maintain a compelling value proposition, (2) identifying multimodal/multiscale imaging workflows, which are necessary for success in most clinical scenarios, and (3) developing effective artificial intelligence tools for clinical decision support, tempered by a realization that complete adoption of such tools will be slow. CONCLUSIONS: The convergence of imaging modalities, academic-industry-clinician partnerships, and new computational capabilities has the potential to catalyze rapid progress and adoption of IVM in the next few decades.


Subject(s)
Artificial Intelligence , Intravital Microscopy , Forecasting , Microscopy/methods
5.
Methods Mol Biol ; 2440: 181-196, 2022.
Article in English | MEDLINE | ID: mdl-35218540

ABSTRACT

Live imaging of zebrafish embryos that maintains normal development can be difficult to achieve due to a combination of sample mounting, immobilization, and phototoxicity issues that, once overcome, often still results in image quality sufficiently poor that computer-aided analysis or even manual analysis is not possible. Here, we describe our mounting strategy for imaging the zebrafish midbrain-hindbrain boundary (MHB) with light sheet fluorescence microscopy (LSFM) and pilot experiments to create a study-specific set of parameters for semiautomatically tracking cellular movements in the embryonic midbrain primordium during zebrafish segmentation.


Subject(s)
Zebrafish Proteins , Zebrafish , Animals , Mesencephalon , Microscopy, Fluorescence , Rhombencephalon
6.
Front Cell Dev Biol ; 9: 739079, 2021.
Article in English | MEDLINE | ID: mdl-34858975

ABSTRACT

From the combined perspective of biologists, microscope instrumentation developers, imaging core facility scientists, and high performance computing experts, we discuss the challenges faced when selecting imaging and analysis tools in the field of light-sheet microscopy. Our goal is to provide a contextual framework of basic computing concepts that cell and developmental biologists can refer to when mapping the peculiarities of different light-sheet data to specific existing computing environments and image analysis pipelines. We provide our perspective on efficient processes for tool selection and review current hardware and software commonly used in light-sheet image analysis, as well as discuss what ideal tools for the future may look like.

7.
Stem Cells Transl Med ; 10(12): 1650-1665, 2021 12.
Article in English | MEDLINE | ID: mdl-34505405

ABSTRACT

Human mesenchymal stem cells (hMSCs) are effective in treating disorders resulting from an inflammatory or heightened immune response. The hMSCs derived from induced pluripotent stem cells (ihMSCs) share the characteristics of tissue derived hMSCs but lack challenges associated with limited tissue sources and donor variation. To meet the expected future demand for ihMSCs, there is a need to develop scalable methods for their production at clinical yields while retaining immunomodulatory efficacy. Herein, we describe a platform for the scalable expansion and rapid harvest of ihMSCs with robust immunomodulatory activity using degradable gelatin methacryloyl (GelMA) microcarriers. GelMA microcarriers were rapidly and reproducibly fabricated using a custom microfluidic step emulsification device at relatively low cost. Using vertical wheel bioreactors, 8.8 to 16.3-fold expansion of ihMSCs was achieved over 8 days. Complete recovery by 5-minute digestion of the microcarriers with standard cell dissociation reagents resulted in >95% viability. The ihMSCs matched or exceeded immunomodulatory potential in vitro when compared with ihMSCs expanded on monolayers. This is the first description of a robust, scalable, and cost-effective method for generation of immunomodulatory ihMSCs, representing a significant contribution to their translational potential.


Subject(s)
Induced Pluripotent Stem Cells , Mesenchymal Stem Cells , Bioreactors , Cell Culture Techniques/methods , Cell Differentiation , Cell Proliferation , Gelatin/pharmacology , Humans , Methacrylates
8.
Sci Rep ; 11(1): 4984, 2021 03 02.
Article in English | MEDLINE | ID: mdl-33654229

ABSTRACT

We demonstrate that structured illumination microscopy has the potential to enhance fluorescence lifetime imaging microscopy (FLIM) as an early detection method for oral squamous cell carcinoma. FLIM can be used to monitor or detect changes in the fluorescence lifetime of metabolic cofactors (e.g. NADH and FAD) associated with the onset of carcinogenesis. However, out of focus fluorescence often interferes with this lifetime measurement. Structured illumination fluorescence lifetime imaging (SI-FLIM) addresses this by providing depth-resolved lifetime measurements, and applied to oral mucosa, can localize the collected signal to the epithelium. In this study, the hamster model of oral carcinogenesis was used to evaluate SI-FLIM in premalignant and malignant oral mucosa. Cheek pouches were imaged in vivo and correlated to histopathological diagnoses. The potential of NADH fluorescence signal and lifetime, as measured by widefield FLIM and SI-FLIM, to differentiate dysplasia (pre-malignancy) from normal tissue was evaluated. ROC analysis was carried out with the task of discriminating between normal tissue and mild dysplasia, when changes in fluorescence characteristics are localized to the epithelium only. The results demonstrate that SI-FLIM (AUC = 0.83) is a significantly better (p-value = 0.031) marker for mild dysplasia when compared to widefield FLIM (AUC = 0.63).


Subject(s)
Mouth Neoplasms , NADP/metabolism , Squamous Cell Carcinoma of Head and Neck , Animals , Mesocricetus , Microscopy, Fluorescence , Mouth Neoplasms/metabolism , Mouth Neoplasms/pathology , Squamous Cell Carcinoma of Head and Neck/metabolism , Squamous Cell Carcinoma of Head and Neck/pathology
9.
J Med Imaging (Bellingham) ; 8(1): 014503, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33542945

ABSTRACT

Purpose: Mesenchymal stem cells (MSCs) have demonstrated clinically relevant therapeutic effects for treatment of trauma and chronic diseases. The proliferative potential, immunomodulatory characteristics, and multipotentiality of MSCs in monolayer culture is reflected by their morphological phenotype. Standard techniques to evaluate culture viability are subjective, destructive, or time-consuming. We present an image analysis approach to objectively determine morphological phenotype of MSCs for prediction of culture efficacy. Approach: The algorithm was trained using phase-contrast micrographs acquired during the early and mid-logarithmic stages of MSC expansion. Cell regions are localized using edge detection, thresholding, and morphological operations, followed by cell marker identification using H-minima transform within each region to differentiate individual cells from cell clusters. Clusters are segmented using marker-controlled watershed to obtain single cells. Morphometric and textural features are extracted to classify cells based on phenotype using machine learning. Results: Algorithm performance was validated using an independent test dataset of 186 MSCs in 36 culture images. Results show 88% sensitivity and 86% precision for overall cell detection and a mean Sorensen-Dice coefficient of 0.849 ± 0.106 for segmentation per image. The algorithm exhibited an area under the curve of 0.816 ( CI 95 = 0.769 to 0.886) and 0.787 ( CI 95 = 0.716 to 0.851) for classifying MSCs according to their phenotype at early and mid-logarithmic expansion, respectively. Conclusions: The proposed method shows potential to segment and classify low and moderately dense MSCs based on phenotype with high accuracy and robustness. It enables quantifiable and consistent morphology-based quality assessment for various culture protocols to facilitate cytotherapy development.

10.
Oral Oncol ; 105: 104635, 2020 06.
Article in English | MEDLINE | ID: mdl-32247986

ABSTRACT

INTRODUCTION: Incomplete head and neck cancer resection occurs in up to 85% of cases, leading to increased odds of local recurrence and regional metastases; thus, image-guided surgical tools for accurate, in situ and fast detection of positive margins during head and neck cancer resection surgery are urgently needed. Oral epithelial dysplasia and cancer development is accompanied by morphological, biochemical, and metabolic tissue and cellular alterations that can modulate the autofluorescence properties of the oral epithelial tissue. OBJECTIVE: This study aimed to test the hypothesis that autofluorescence biomarkers of oral precancer and cancer can be clinically imaged and quantified by means of multispectral fluorescence lifetime imaging (FLIM) endoscopy. METHODS: Multispectral autofluorescence lifetime images of precancerous and cancerous lesions from 39 patients were imaged in vivo using a novel multispectral FLIM endoscope and processed to generate widefield maps of biochemical and metabolic autofluorescence biomarkers of oral precancer and cancer. RESULTS: Statistical analyses applied to the quantified multispectral FLIM endoscopy based autofluorescence biomarkers indicated their potential to provide contrast between precancerous/cancerous vs. healthy oral epithelial tissue. CONCLUSION: To the best of our knowledge, this study represents the first demonstration of label-free biochemical and metabolic clinical imaging of precancerous and cancerous oral lesions by means of widefield multispectral autofluorescence lifetime endoscopy. Future studies will focus on demonstrating the capabilities of endogenous multispectral FLIM endoscopy as an image-guided surgical tool for positive margin detection during head and neck cancer resection surgery.


Subject(s)
Endoscopy/methods , Microscopy, Fluorescence/methods , Mouth Neoplasms/diagnostic imaging , Precancerous Conditions/diagnostic imaging , Female , Humans , Male , Precancerous Conditions/pathology
11.
Biomed Opt Express ; 10(10): 5445-5460, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31646057

ABSTRACT

Tuberculosis is one of the deadliest infectious diseases worldwide. New tools to study pathogenesis and monitor subjects in pre-clinical studies to develop treatment regimens are critical for progress. We developed an improved optical system for detecting bacteria in lungs of mice using internal illumination. We present a computational optical model of the full mouse torso to characterize the optical system. Simulated theoretical limits for the lowest detectable bacterial load support the experimental improvements with an internal illumination source, and suggest that protocol improvements could further lower the detection threshold.

12.
J Biomed Mater Res A ; 107(10): 2160-2173, 2019 10.
Article in English | MEDLINE | ID: mdl-31107571

ABSTRACT

One of the central challenges in the field of vaccine delivery is to develop a delivery method that maintains antigen stability while also enabling control over the system's release kinetics. Addressing these challenges would not only allow for expanded access to vaccines worldwide but would also help significantly reduce mortality rates in developing countries. In this article, we report the development of single-injection vaccine depots for achieving novel delayed burst release. Synthesized poly(ε-caprolactone) and poly(ε-caprolactone) triacrylate were used to form stationary bubbles within an aqueous solution of 10% carboxymethylcellulose. These polymeric bubbles (referred to as "polybubbles") can then be injected with an aqueous solution of cargo, resulting in the formation of a polymeric shell. The puncture resulting from cargo injection self-heals prior to ultraviolet (UV) curing. UV curing and lyophilization were shown to enhance the stability of the polybubbles. BSA- CF 488 and HIV1 gp120/41 were used as the antigen in the study as a proof-of-concept. Further endeavors to automate the production of polybubbles are underway.


Subject(s)
Ultraviolet Rays , Vaccines/radiation effects , Carboxymethylcellulose Sodium/chemistry , Chlorine/analysis , Emulsions/chemistry , Freeze Drying , HIV Envelope Protein gp120/metabolism , Humidity , Hydrogels/chemistry , Molecular Weight , Nanoparticles/chemistry , Particle Size , Polyesters/chemistry , Temperature , Time-Lapse Imaging
13.
Opt Lett ; 43(20): 5001-5004, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-30320804

ABSTRACT

We employ a concentric sphere Mie scattering model to describe light scattering by pulmonary alveoli and airway surface liquid (ASL). Using this layered sphere model, we compare alveolar scattering at different points along the respiratory cycle and observe the effect of ASL thickness on light scattering in the lung. We have also extrapolated the model to investigate alveolar scattering in various animal models of pulmonary disease. This model of pulmonary light scattering can estimate in vivo optical properties for normal and pathological states, potentially aiding the design of optical systems for diagnosis and investigation of pulmonary pathologies.

14.
J Vis Exp ; (132)2018 02 12.
Article in English | MEDLINE | ID: mdl-29553502

ABSTRACT

The rapid development of new optical imaging techniques is dependent on the availability of low-cost, customizable, and easily reproducible standards. By replicating the imaging environment, costly animal experiments to validate a technique may be circumvented. Predicting and optimizing the performance of in vivo and ex vivo imaging techniques requires testing on samples that are optically similar to tissues of interest. Tissue-mimicking optical phantoms provide a standard for evaluation, characterization, or calibration of an optical system. Homogenous polymer optical tissue phantoms are widely used to mimic the optical properties of a specific tissue type within a narrow spectral range. Layered tissues, such as the epidermis and dermis, can be mimicked by simply stacking these homogenous slab phantoms. However, many in vivo imaging techniques are applied to more spatially complex tissue where three dimensional structures, such as blood vessels, airways, or tissue defects, can affect the performance of the imaging system. This protocol describes the fabrication of a tissue-mimicking phantom that incorporates three-dimensional structural complexity using material with optical properties of tissue. Look-up tables provide India ink and titanium dioxide recipes for optical absorption and scattering targets. Methods to characterize and tune the material optical properties are described. The phantom fabrication detailed in this article has an internal branching mock airway void; however, the technique can be broadly applied to other tissue or organ structures.


Subject(s)
Optical Imaging/instrumentation , Optics and Photonics/instrumentation , Phantoms, Imaging , Animals , Carbon , Lung/diagnostic imaging , Mice , Optical Imaging/methods , Optics and Photonics/methods , Titanium
15.
J Biomed Opt ; 23(7): 1-12, 2018 03.
Article in English | MEDLINE | ID: mdl-29573254

ABSTRACT

We describe a Monte Carlo model of the mouse torso to optimize illumination of the mouse lung for fluorescence detection of low levels of pulmonary pathogens, specifically Mycobacterium tuberculosis. After validation of the simulation with an internally illuminated optical phantom, the entire mouse torso was simulated to compare external and internal illumination techniques. Measured optical properties of deflated mouse lungs were scaled to mimic the diffusive properties of inflated lungs in vivo. Using the full-torso model, a 2 × to 3 × improvement in average fluence rate in the lung was seen for dorsal compared with ventral positioning of the mouse with external illumination. The enhancement in average fluence rate in the lung using internal excitation was 40 × to 60 × over external illumination in the dorsal position. Parameters of the internal fiber optic source were manipulated in the model to guide optimization of the physical system and experimental protocol for internal illumination and whole-body detection of fluorescent mycobacteria in a mouse model of infection.


Subject(s)
Lung/diagnostic imaging , Models, Biological , Optical Imaging/methods , Animals , Mice , Mycobacterium tuberculosis , Phantoms, Imaging , Tuberculosis/diagnostic imaging , Tuberculosis/microbiology , Whole Body Imaging
16.
Biomed Opt Express ; 8(3): 1455-1465, 2017 Mar 01.
Article in English | MEDLINE | ID: mdl-28663841

ABSTRACT

In this paper, we demonstrate the ability of structured illumination microscopy to enhance the ability of fluorescence lifetime imaging to resolve fluorescence lifetimes in relatively thick samples that possess distinct but spectrally overlapping fluorescent layers. Structured illumination fluorescent lifetime imaging microscopy (SI-FLIM) is shown to be able to accurately reconstruct lifetime values in homogenous fluorophore samples (POPOP, NADH, and FAD) as well as accurately measure fluorescent lifetime in two layer models that are layered with NADH/FAD over POPOP, where NADH/FAD and POPOP have spectral overlap. Finally, the ability of SI-FLIM was demonstrated in a hamster cheek pouch ex vivo to show that more accurate lifetimes could be measured for each layer of interest in the oral mucosa (epithelium and submucosa).

17.
J Biomed Opt ; 22(5): 56008, 2017 05 01.
Article in English | MEDLINE | ID: mdl-28541447

ABSTRACT

A reflectance confocal endomicroscope with double-clad fiber coupler and electrically tunable focus lens is applied to imaging of the oral mucosa. The instrument is designed to be lightweight and robust for clinical use. The tunable lens allows axial scanning through > 250 ?? ? m in the epithelium when the probe tip is placed in contact with tissue. Images are acquired at 6.6 frames per second with a field of view diameter up to 850 ?? ? m . In vivo imaging of a wide range of normal sites in the oral cavity demonstrates the accessibility of the handheld probe. In vivo imaging of clinical lesions diagnosed as inflammation and dysplasia illustrates the ability of reflectance confocal endomicroscopy to image cellular changes associated with pathology.


Subject(s)
Microscopy, Confocal/instrumentation , Mouth Mucosa/diagnostic imaging , Humans , Mouth/diagnostic imaging
18.
J Biophotonics ; 10(6-7): 821-829, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27753271

ABSTRACT

Tuberculosis is a pulmonary disease with an especially high mortality rate in immuno-compromised populations, specifically children and HIV positive individuals. The causative agent, Mycobacterium tuberculosis (Mtb), is a very slow growing and difficult organism to work with, making both diagnosis and development of effective treatments cumbersome. We utilize a fiber-optic fluorescence microendoscope integrated with a whole-body imaging system for in vivo Mtb detection. The system exploits an endogenous enzyme of Mtb (ß-lactamase, or BlaC) using a BlaC-specific NIR fluorogenic substrate. In the presence of BlaC, this substrate is cleaved and becomes fluorescent. Using intravital illumination of the lung to excite this probe, sensitivity of the optical system increases over trans- and epi-illumination methods of whole-body fluorescence imaging. We demonstrate that integration of these imaging technologies with BlaC-specific fluorescent reporter probe improves the level of detection to ∼100 colony forming units, a 100× increase in sensitivity in comparison to epi-illumination and a 10× increase in sensitivity in comparison to previous work in intravital excitation of tdTomato-expressing Mtb. This lower detection threshold enables the study of early stage bacterial infections with clinical strains of Mtb and longitudinal studies of disease pathogenesis and therapeutic efficacy with multiple time points in a single animal.


Subject(s)
Optical Imaging , Tuberculosis, Pulmonary/diagnostic imaging , Whole Body Imaging , beta-Lactamases/chemistry , Animals , Female , Mice , Mice, Inbred BALB C , Mycobacterium tuberculosis , Sensitivity and Specificity
19.
Photochem Photobiol ; 92(5): 694-701, 2016 09.
Article in English | MEDLINE | ID: mdl-27499123

ABSTRACT

Successful early detection and demarcation of oral carcinoma can greatly impact the associated morbidity and mortality rates. Current methods for detection of oral cancer include comprehensive visual examination of the oral cavity, typically followed by tissue biopsy. A noninvasive means to guide the clinician in making a more objective and informed decision toward tissue biopsy can potentially improve the diagnostic yield of this process. To this end, we investigate the potential of fluorescence lifetime imaging (FLIM) for objective detection of oral carcinoma in the hamster cheek pouch model of oral carcinogenesis in vivo. We report that systematically selected FLIM features can differentiate between low-risk (normal, benign and low-grade dysplasia) and high-risk (high-grade dysplasia and cancer) oral lesions with sensitivity and specificity of 87.26% and 93.96%, respectively. We also show the ability of FLIM to generate "disease" maps of the tissue which can be used to evaluate relative risk of neoplasia. The results demonstrate the potential of multispectral FLIM with objective image analysis as a noninvasive tool to guide comprehensive oral examination.


Subject(s)
Cheek/diagnostic imaging , Mouth Neoplasms/diagnostic imaging , Optical Imaging , Animals , Cheek/pathology , Cricetinae , Humans
20.
PLoS One ; 11(2): e0149932, 2016.
Article in English | MEDLINE | ID: mdl-26901051

ABSTRACT

Whole-animal fluorescence imaging with recombinant or fluorescently-tagged pathogens or cells enables real-time analysis of disease progression and treatment response in live animals. Tissue absorption limits penetration of fluorescence excitation light, particularly in the visible wavelength range, resulting in reduced sensitivity to deep targets. Here, we demonstrate the use of an optical fiber bundle to deliver light into the mouse lung to excite fluorescent bacteria, circumventing tissue absorption of excitation light in whole-animal imaging. We present the use of this technology to improve detection of recombinant reporter strains of tdTomato-expressing Mycobacterium bovis BCG (Bacillus Calmette Guerin) bacteria in the mouse lung. A microendoscope was integrated into a whole-animal fluorescence imager to enable intravital excitation in the mouse lung with whole-animal detection. Using this technique, the threshold of detection was measured as 103 colony forming units (CFU) during pulmonary infection. In comparison, the threshold of detection for whole-animal fluorescence imaging using standard epi-illumination was greater than 106 CFU.


Subject(s)
Fluorescence , Optical Imaging/methods , Animals , Female , Lung/microbiology , Mice , Mycobacterium bovis/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...