Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Mater Sci Eng C Mater Biol Appl ; 33(6): 3396-403, 2013 Aug 01.
Article in English | MEDLINE | ID: mdl-23706226

ABSTRACT

Artificial corneas or keratoprostheses are intended to replace diseased or damaged cornea in the event that vision cannot be restored using donor cornea tissue. A new class of artificial cornea comprising a combination of poly (2-hydroxyethyl methacrylate) and poly (methyl methacrylate) was developed which was fabricated using a gas foaming technique. Referred to as the gas-foamed KPro, it was designed to permit clear vision and secure host biointegration to facilitate long-term stability of the device. In vitro assessments show cell growth into the body of the porous edge or skirt of the gas-foamed KPro. The optically transparent center (i.e., core) of the device demonstrates 85 - 90% of light transmittance in the 500 - 700 nm wavelength range. Mechanical tensile data indicates that the gas-foamed KPro is mechanically stable enough to maintain its structure in the ocular environment and also during implantation. The gas-foamed KPro may provide an alternate option for cornea replacement that minimizes post implantation tissue melting, thereby achieving long-term stability in the ocular environment.


Subject(s)
Artificial Organs , Biocompatible Materials/chemistry , Gases/chemistry , Polyhydroxyethyl Methacrylate/chemistry , Polymethyl Methacrylate/chemistry , Porosity , Tensile Strength
2.
Hum Factors ; 54(6): 1066-74, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23397814

ABSTRACT

OBJECTIVE: The aim of this study was to investigate the effect of five chair designs on interface pressure distribution and tissue perfusion in the buttock-thigh region. BACKGROUND: Prolonged sitting has been found to contribute to the symptoms of work-related low back pain. Studies have found that chair design affects users' sitting posture and comfort. As sitting applies pressure to the user, it is necessary to investigate how chair design affects sitting pressure and tissue perfusion during sitting. METHOD: We tested five chair designs (Suspension A, Suspension B, Foam A, Foam B, and bicompliant) on 15 young, healthy females. Sitting interface pressure and buttock-thigh tissue perfusion (in terms oftranscutaneous partial pressure of oxygen and carbon dioxide, tcPO2 and tcPCO2, respectively) were measured during 10-min sitting on each chair. RESULTS: We found that chair design significantly affected the distribution of the sitting pressure (p < .001) and buttock-thigh tissue perfusion (p < .023). Average pressure and total contact area were found highest in both foam designs, and the average pressure was the lowest in one of the suspension designs. Across all tested chair designs, the anterior portion of the seat sustained the lowest contact pressure. It was also found that tcPO2 was the lowest (p < .003) and tcPCO2 was the highest (p < .001) in tissue around ischial tuberosity for all chair designs. CONCLUSION: Chair design and materials of the seat significantly affect the sitting interface pressure distribution and tissue perfusion in sitting area. Further evaluation of these outcomes may provide useful information to correlate chair design with sitting comfort.


Subject(s)
Buttocks/blood supply , Interior Design and Furnishings , Adult , Carbon Dioxide/analysis , Equipment Design , Female , Humans , Oxygen/analysis , Posture/physiology , Pressure , Workplace , Young Adult
3.
Clin Anat ; 24(5): 638-45, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21647964

ABSTRACT

The goal of this experiment was to investigate changes in the thickness of the soft tissue overlying the ischial tuberosity (IT) due to changes in hip flexion angle and the addition of a sitting load. Eleven healthy subjects were tested. An apparatus constructed from foam blocks and an air bladder was used to position the subjects in different postures within an MRI tube. MRI images of the buttocks and thigh were obtained for four postures: Supine, 45° Hip Flexion, Non-Weight-Bearing 90° Hip-Flexion, and Weight-Bearing 90° Hip-Flexion. The thickness of muscle, adipose tissue, and skin was measured between the IT tip and skin surface, perpendicular to the cushion placed beneath the thighs. The tissue overlying the IT was found to be significantly (P < 0.001) thinner in 90° Hip-Flexion (73.8 ± 9.0 mm) than in the supine position (135.9 ± 8.1 mm). Muscle thickness decreased significantly from Supine to Non-Weight-Bearing 90° Hip-Flexion (59.1 ± 8.5%, P < 0.001), and further decreased from Non-Weight-Bearing to Weight-Bearing 90° Hip-Flexion (46.2 ± 7.9%, P < 0.001). Under Weight-Bearing 90° Hip-Flexion, the muscle tissue deformed significantly (P < 0.001) more than the adipose tissue and skin. We concluded that the tissue thickness covering the IT significantly decreased with hip flexion, and further decreased by nearly half during loading caused by sitting. In addition, the muscle tissue experienced the largest deformation during sitting. The results of this study may improve our understanding of risk factors for pressure ulcer development due to changes in tissue padding over the IT in different postures.


Subject(s)
Hip Joint/anatomy & histology , Ischium/anatomy & histology , Magnetic Resonance Imaging , Adult , Female , Hip Joint/physiology , Humans , Ischium/physiology , Male , Range of Motion, Articular , Weight-Bearing
4.
J Arthroplasty ; 26(4): 596-605, 2011 Jun.
Article in English | MEDLINE | ID: mdl-20817389

ABSTRACT

We prospectively evaluated acetabular cup placement in total hip arthroplasty with an imageless computer navigation system or using conventional manual technique. The achieved cup orientation in the manual group had substantially larger variances and greater placement error than the navigation cases. The use of navigation was abandoned in 3 cases because of excessive pelvic tilt and unreliable registration of the pelvis. Computer navigation system helped improve the accuracy of the acetabular cup placement for total hip arthroplasty in this study. The variation between the intraoperative navigation readings and the computed tomographic values suggests that relying on palpation of bony landmarks through drapes and tissue is a limitation of this method. Further, the variation in pelvic tilt has an effect on cup placement that requires further studies.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Imaging, Three-Dimensional/methods , Osteoarthritis, Hip/surgery , Surgery, Computer-Assisted/methods , Acetabulum/diagnostic imaging , Acetabulum/surgery , Aged , Arthroplasty, Replacement, Hip/adverse effects , Bone Malalignment/epidemiology , Bone Malalignment/prevention & control , Female , Fluoroscopy , Hip Dislocation/epidemiology , Hip Dislocation/prevention & control , Humans , Imaging, Three-Dimensional/adverse effects , Incidence , Male , Middle Aged , Monitoring, Intraoperative/methods , Prospective Studies , Surgery, Computer-Assisted/adverse effects , Tomography, X-Ray Computed
6.
Gait Posture ; 32(1): 53-6, 2010 May.
Article in English | MEDLINE | ID: mdl-20399661

ABSTRACT

Unsupported sitting requires postural stability of the trunk which is also necessary for almost all activities in daily living, yet there is a lack of research dealing with the persistence of trunk impairment post-stroke using quantitative methodologies. Therefore, the purpose of this study was to investigate unsupported sitting in individuals with chronic stroke by analyzing center of pressure (COP) signals from a force platform. Ten healthy control subjects and ten chronic stroke subjects sat on a chair without a footrest that was placed on top of a force platform. Trials consisted of eyes closed, staring at a target, and COP feedback. COP signals were analyzed using spatial and temporal techniques. Compared to controls, stroke group had larger sway area and larger displacements in all conditions (p<0.05) and less sample entropy (p<0.05) in eyes closed and target conditions. In feedback conditions, both groups had decreased sway area and maximum displacements along with stroke group having increased sample entropy (p<0.05). Our data suggest that trunk control, necessary for unsupported sitting, is impaired well into the chronic stage of stroke onset. Further investigations of sitting should be conducted for better understanding balance deficits under conditions localized to the trunk musculature.


Subject(s)
Posture/physiology , Proprioception/physiology , Stroke/physiopathology , Abdomen , Case-Control Studies , Feedback , Female , Humans , Male , Middle Aged , Thorax
7.
J Tissue Viability ; 19(2): 67-76, 2010 May.
Article in English | MEDLINE | ID: mdl-20006504

ABSTRACT

Many rat/mouse pressure ulcer (PU) models have been developed to test different hypotheses to gain deeper understanding of various causative risk factors, the progress of PUs, and assessing effectiveness of potential treatment modalities. The recently emphasized deep tissue injury (DTI) mechanism for PU formation has received increased attention and several studies reported findings on newly developed DTI animal models. However, concerns exist for the clinical relevance and validity of these models, especially when the majority of the reported rat PU/DTI models were not built upon SCI animals and many of the DTI research did not simulate well the clinical observation. In this study, we propose a rat PU and DTI model which is more clinically relevant by including chronic SCI condition into the rat PU model and to simulate the role of bony prominence in DTI formation by using an implant on the bone-tissue interface. Histological data and imaging findings confirmed that the condition of chronic SCI had significant effect on pressure induced tissue injury in a rat PU model and the including a simulated bony prominence in rat DTI model resulted in significantly greater injury in deep muscle tissue. Further integration of the SCI condition and the simulated bony prominence would result a rat PU/DTI model which can simulate even more accurately the clinical phenomenon and yield more clinically relevant findings.


Subject(s)
Disease Models, Animal , Pressure Ulcer , Spinal Cord Injuries , Animals , Female , Magnetic Resonance Imaging , Paraplegia/pathology , Pressure Ulcer/pathology , Prostheses and Implants , Rats , Rats, Sprague-Dawley , Reproducibility of Results , Spinal Cord Injuries/pathology
8.
J Biomech ; 43(2): 235-41, 2010 Jan 19.
Article in English | MEDLINE | ID: mdl-19878947

ABSTRACT

Patellofemoral pain is a common knee disorder with a multi-factorial etiology related to abnormal patellar tracking. Our hypothesis was that the pattern of three-dimensional rotation and translation of the patella induced by selective activation of individual quadriceps components would differ between subjects with patellofemoral pain and healthy subjects. Nine female subjects with patellofemoral pain and seven healthy female subjects underwent electrical stimulation to selectively activate individual quadriceps components (vastus medialis obliquus, VMO; vastus medialis lateralis, VML; vastus lateralis, VL) with the knee at 0 degrees and 20 degrees flexion, while three-dimensional patellar tracking was recorded. Normalized direction of rotation and direction of translation characterized the relative amplitudes of each component of patellar movement. VMO activation in patellofemoral pain caused greater medial patellar rotation (distal patellar pole rotates medially in frontal plane) at both knee positions (p<0.01), and both VMO and VML activation caused increased anterior patellar translation (p<0.001) in patellofemoral pain compared to healthy subjects at 20 degrees knee flexion. VL activation caused more lateral patellar translation (p<0.001) in patellofemoral pain compared to healthy subjects. In healthy subjects the 3-D mechanical action of the VMO is actively modulated with knee flexion angle while such modulation was not observed in PFP subjects. This could be due to anatomical differences in the VMO insertion on the patella and medial quadriceps weakness. Quantitative evaluation of the influence of individual quadriceps components on patellar tracking will aid understanding of the knee extensor mechanism and provide insight into the etiology of patellofemoral pain.


Subject(s)
Patella/physiopathology , Patellofemoral Pain Syndrome/physiopathology , Quadriceps Muscle/physiopathology , Adult , Biomechanical Phenomena , Case-Control Studies , Electric Stimulation , Female , Humans , Imaging, Three-Dimensional , Patellofemoral Pain Syndrome/etiology , Rotation , Young Adult
9.
Adv Skin Wound Care ; 22(11): 514-21, 2009 Nov.
Article in English | MEDLINE | ID: mdl-20026933

ABSTRACT

OBJECTIVE: To evaluate whether an individualized cyclic pressure-relief protocol accelerates wound healing in wheelchair users with established pressure ulcers (PrUs). DESIGN: Randomized controlled study. SETTING: Spinal cord injury clinics. PARTICIPANTS: Forty-four subjects, aged 18-79 years, with a Stage II or Stage III PrU, were randomly assigned to the control (n = 22) or treatment (n = 22) groups. INTERVENTIONS: Subjects in the treatment group used wheelchairs equipped with an individually adjusted automated seat that provided cyclic pressure relief, and those in the control group used a standard wheelchair. All subjects sat in wheelchairs for a minimum of 4 hours per day for 30 days during their PrU treatment. MAIN OUTCOME MEASURES: Wound characteristics were assessed using the Pressure Ulcer Scale for Healing (PUSH) tool and wound dimensions recorded with digital photographs twice a week. Median healing time for a 30% healing relative to initial measurements, the percentage reduction in wound area, and the percentage improvement in PUSH score achieved at the end of the trial were compared between groups. RESULTS: At the end of 30 days, both groups demonstrated a general trend of healing. However, the treatment group was found to take significantly less time to achieve 30% healing for the wound measurement compared with the control group. The percentage improvement of the wound area and PUSH scores were greater in using cyclic seating (45.0 +/- 21.0, P < .003; 29.9 +/- 24. 6, P < .003) compared with standard seating (10.2 +/- 34.9, 5.8 +/- 9.2). CONCLUSIONS: The authors' findings show that cyclically relieving pressure in the area of a wound for seated individuals can greatly aid wound healing. The current study provides evidence that the individualized cyclic pressure-relief protocol helps promote pressure wound healing in a clinical setting. The authors concluded that the individualized cyclic pressure relief may have substantial benefits in accelerating the healing process in wheelchair users with existing PrUs, while maintaining the mobility of individuals with SCI during the PrU treatment.


Subject(s)
Pressure Ulcer/therapy , Spinal Cord Injuries/complications , Wheelchairs/classification , Wound Healing , Adolescent , Adult , Aged , Female , Humans , Linear Models , Male , Middle Aged , Paraplegia/complications , Periodicity , Pressure , Pressure Ulcer/etiology , Pressure Ulcer/physiopathology , Quadriplegia/complications , Risk Assessment , Young Adult
10.
J Shoulder Elbow Surg ; 18(3): 379-85, 2009.
Article in English | MEDLINE | ID: mdl-19269860

ABSTRACT

BACKGROUND: Treatment of partial thickness supraspinatus tendon tears is controversial with no clearly defined treatment algorithms based on severity of tears. This study aims to evaluate the relationship between depth of partial thickness tears and strain. METHODS: Bursal-sided partial thickness tears were created at 1 mm increments in depth at the anterior portion of the supraspinatus tendon to 3/4 tendon width on ten fresh-frozen shoulder specimens. The supraspinatus muscle was dynamically loaded from 0-50N, and strain recorded at both the anterior and posterior portions of the tendon. RESULTS: Strain in the intact posterior portion increased monotonically with tear depth and supraspinatus force. Strain in the torn anterior portion decreased with increasing tear thickness and loading force. At 60% thickness tear, strain was significantly higher (P = 0.023) in the intact posterior portion compared to intact tendon. As the tear thickness exceeded 50% tendon thickness, the strain in the intact tendon rapidly increased nonlinearly. CONCLUSIONS: Biomechanical results herein suggest increasing potential for tear propagation in the transverse plane with increasing depth of tears, and biomechanically supports repairs of grade III (>50% thickness).


Subject(s)
Biomechanical Phenomena , Bursa, Synovial/pathology , Rotator Cuff/pathology , Shoulder Joint/pathology , Tendon Injuries/pathology , Aged , Cadaver , Female , Humans , Male , Middle Aged , Probability , Rotator Cuff Injuries , Sensitivity and Specificity , Shoulder Joint/physiopathology , Sprains and Strains/pathology , Stress, Mechanical , Tendon Injuries/physiopathology , Tensile Strength
11.
BMC Musculoskelet Disord ; 10: 17, 2009 Feb 05.
Article in English | MEDLINE | ID: mdl-19193245

ABSTRACT

BACKGROUND: Compared to standing posture, sitting decreases lumbar lordosis, increases low back muscle activity, disc pressure, and pressure on the ischium, which are associated with occupational LBP. A sitting device that reduces spinal load and low back muscle activities may help increase sitting comfort and reduce LBP risk. The objective of this study is to investigate the biomechanical effect of sitting with a reduced ischial support and an enhanced lumbar support (Off-Loading) on load, interface pressure and muscle activities. METHODS: A laboratory test in low back pain (LBP) and asymptomatic subjects was designed to test the biomechanical effect of using the Off-Loading sitting posture. The load and interface pressure on seat and the backrest, and back muscle activities associated with usual and this Off-Loading posture were recorded and compared between the two postures. RESULTS: Compared with Normal (sitting upright with full support of the seat and flat backrest) posture, sitting in Off-Loading posture significantly shifted the center of the force and the peak pressure on the seat anteriorly towards the thighs. It also significantly decreased the contact area on the seat and increased that on the backrest. It decreased the lumbar muscle activities significantly. These effects are similar in individuals with and without LBP. CONCLUSION: Sitting with reduced ischial support and enhanced lumbar support resulted in reduced sitting load on the lumbar spine and reduced the lumbar muscular activity, which may potentially reduce sitting-related LBP.


Subject(s)
Low Back Pain/physiopathology , Lumbosacral Region/physiopathology , Occupational Diseases/physiopathology , Posture/physiology , Adult , Biomechanical Phenomena , Biomedical Engineering , Female , Humans , Ischium/physiopathology , Low Back Pain/prevention & control , Male , Muscle, Skeletal/physiopathology , Occupational Diseases/prevention & control
12.
Clin Biomech (Bristol, Avon) ; 23(8): 1004-11, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18541352

ABSTRACT

BACKGROUND: Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-invasive computed tomography method for post-operative determination of acetabular cup orientation. METHODS: Total hip arthroplasty was performed on seven cadaver hips with the aid of an imageless computer navigation system. The achieved cup orientation were recorded using three methods, (1) intra-operatively using the imageless computer navigation system, (2) post-operatively with direct bone digitization and (3) with a computed tomography based three dimensional model interpreted by three raters. Measurement from the direct bone digitization was taken as the gold standard to evaluate the other two methods. The intra-rater and inter-rater consistency of the computer tomography-model method were assessed by Cronbach's alpha determination. FINDINGS: Compared with the cup orientation obtained from the direct bone digitization, the average difference for anteversion and abduction were 3.3 (3.5) degrees (P=0.045) and 0.6 (3.7) degrees , respectively, for navigation reading. The average differences for computer tomography-model for three raters were 0.5 (2.1) degrees , 0.8 (1.5) degrees and 3.2 (3.3) degrees (P=0.043) for anteversion and 0.4 (1.6) degrees , 0.3 (1.6) degrees and 2.1 (2.7) degrees for abduction. The intra-rater consistency ranged from 0.626 for a novice rater to over 0.97 for experience raters. The inter-rater consistency (including novice and experienced raters) was over 0.90. INTERPRETATION: While the values for cup orientation determined with imageless computer navigation were comparable to those from direct bone and implant digitization, the measurement for anteversion obtained was not as accurate as that for abduction. The proposed computer tomography-model method has an excellent intra-rater consistency for experienced raters, as well as an excellent overall inter-rater consistency. The study confirms that a non-invasive computed tomography based model analysis can be used in clinical practice as a valid method for post-operatively evaluating the orientation of the acetabular component.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip , Hip Prosthesis , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Acetabulum/anatomy & histology , Aged , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/standards , Cadaver , Computer Simulation , Female , Fracture Healing , Hip Prosthesis/standards , Humans , Models, Anatomic , Postoperative Care/instrumentation , Postoperative Care/methods , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/standards , Tomography, X-Ray Computed/standards
13.
J Spinal Cord Med ; 31(1): 88-96, 2008.
Article in English | MEDLINE | ID: mdl-18533418

ABSTRACT

BACKGROUND/OBJECTIVE: Differences in soft-tissue stiffness may provide for a quantitative assessment and detection technique for pressure ulcers or deep-tissue injury. An ultrasound indentation system may provide a relatively convenient, simple, and noninvasive method for quantitative measurement of changes in soft-tissue stiffness in vivo. METHODS: The Tissue Ultrasound Palpation System (TUPS) was used to quantitatively measure changes in soft-tissue stiffness at different anatomical locations within and between able-bodied persons and individuals with chronic spinal cord injury (SCI). The stiffness of soft tissue was measured at the ischial tuberosity, greater trochanter, posterior midthigh, and biceps brachii. Additionally, soft-tissue thickness and soft-tissue deformation were also measured. RESULTS: Significant differences in soft-tissue stiffness were observed within the various anatomical locations tested, in both the able-bodied and SCI groups. Differences in soft-tissue stiffness were also observed between the 2 groups. Participants with SCI had significantly softer tissue in their buttock-thigh area. CONCLUSIONS: TUPS is a clinically feasible technology that can reliably and effectively detect changes in soft-tissue stiffness. The study has provided a better understanding of the tissue mechanical response to external loading, specifically in the SCI population, suggesting the use of tissue stiffness as a parameter to detect and assess pressure-related soft-tissue injury.


Subject(s)
Soft Tissue Injuries/diagnostic imaging , Soft Tissue Injuries/etiology , Spinal Cord Injuries/complications , Ultrasonics , Adult , Female , Humans , Male , Middle Aged , Muscle Denervation , Numerical Analysis, Computer-Assisted , Soft Tissue Injuries/pathology , Ultrasonography
14.
J Spinal Cord Med ; 30(5): 497-507, 2007.
Article in English | MEDLINE | ID: mdl-18092567

ABSTRACT

BACKGROUND/OBJECTIVE: To study the effect on tissue perfusion of relieving interface pressure using standard wheelchair pushups compared with a mechanical automated dynamic pressure relief system. DESIGN: Repeated measures in 2 protocols on 3 groups of subjects. PARTICIPANTS: Twenty individuals with motor-complete paraplegia below T4, 20 with motor-complete tetraplegia, and 20 able-bodied subjects. METHODS: Two 1-hour sitting protocols: dynamic protocol, sitting configuration alternated every 10 minutes between a normal sitting configuration and an off-loading configuration; wheelchair pushup protocol, normal sitting configuration with standard wheelchair pushup once every 20 minutes. MAIN OUTCOME MEASURES: Transcutaneous partial pressures of oxygen and carbon dioxide measured from buttock overlying the ischial tuberosity and interface pressure measured at the seat back and buttocks. Perfusion deterioration and recovery times were calculated during changes in interface pressures. RESULTS: In the off-loading configuration, concentrated interface pressure during the normal sitting configuration was significantly diminished, and tissue perfusion was significantly improved. Wheelchair pushups showed complete relief of interface pressure but incomplete recovery of tissue perfusion. CONCLUSIONS: Interface pressure analysis does not provide complete information about the effectiveness of pressure relief maneuvers. Measures of tissue perfusion may help establish more effective strategies. Relief achieved by standard wheelchair pushups may not be sufficient to recover tissue perfusion compromised during sitting; alternate maneuvers may be necessary. The dynamic seating system provided effective pressure relief with sustained reduction in interface pressure adequate for complete recovery of tissue perfusion. Differences in perfusion recovery times between subjects with spinal cord injury (SCI) and controls raise questions about the importance of changes in vascular responses to pressure after SCI.


Subject(s)
Buttocks/blood supply , Pressure Ulcer/prevention & control , Spinal Cord Injuries/complications , Wheelchairs , Adult , Blood Gas Monitoring, Transcutaneous , Carbon Dioxide/blood , Data Interpretation, Statistical , Humans , Male , Movement , Paraplegia/complications , Paraplegia/physiopathology , Posture/physiology , Pressure , Pressure Ulcer/etiology , Pressure Ulcer/physiopathology , Quadriplegia/complications , Quadriplegia/physiopathology , Regional Blood Flow/physiology , Spinal Cord Injuries/physiopathology
15.
J Shoulder Elbow Surg ; 16(6): 795-802, 2007.
Article in English | MEDLINE | ID: mdl-17936028

ABSTRACT

Repetitive valgus stress of the elbow can result in excessive strain or rupture of the native medial ulnar collateral ligament (MUCL). The flexor-pronator mass (FPM) may be particularly important for elbow valgus stability in overhead-throwing athletes. The aim of this study was to identify the relative contribution of each muscle of the FPM--that is, the flexor carpi ulnaris (FCU), flexor digitorum superficialis (FDS), flexor carpi radialis (FCR), and pronator teres (PT)--and of the extensor-supinator mass, including the extensor carpi ulnaris (ECU), extensor digitorum communis (EDC), extensor carpi radialis longus and brevus, and brachioradialis, to elbow valgus stability at 45 degrees and 90 degrees of elbow flexion angles. Eight fresh-frozen elbow specimens (mean age at death, 73.75 +/- 14.07 years) were tested. With the skin and subcutaneous tissue removed but all muscles left intact, each individual muscle of the FPM and extensor-supinator mass was loaded at 3 levels of force. During loading, strain on the MUCL and the kinematics of the elbow were measured simultaneously. Kinematic measurements were later repeated when the MUCL was fully cut. At 45 degrees and 90 degrees of elbow flexion, individual loading of the FCU, FDS, and FCR caused significant relief to the MUCL whereas the PT produced no significant change. Furthermore, of these flexor muscles, the FCU provided the greatest MUCL relief at both 45 degrees and 90 degrees . In contrast, loading of the ECU at 45 degrees of elbow flexion produced a significant increase in MUCL strain. All FPM muscles caused significant elbow varus movement at both 45 degrees and 90 degrees when loaded individually. At 90 degrees , the FCU created more motion than both the FCR and PT but not the FDS, and the FDS created more motion than the PT. The EDC and ECU created significant valgus movement at 45 degrees and 90 degrees , which became insignificant when the MUCL was transected. Our study suggested that the FCU, FDS, and FCR may function as dynamic stabilizers, with the FCU being the primary stabilizer for elbow valgus stability, incorporating with the MUCL for all tested joint configurations. Our findings also suggest that the ECU and EDC increased MUCL strain and elbow valgus movement at both 45 degrees and 90 degrees .


Subject(s)
Elbow Joint/physiopathology , Joint Instability/physiopathology , Muscle, Skeletal/physiopathology , Aged , Aged, 80 and over , Biomechanical Phenomena , Collateral Ligaments/injuries , Collateral Ligaments/physiopathology , Female , Humans , Male , Middle Aged , Movement
16.
Med Biol Eng Comput ; 45(11): 1079-84, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17922158

ABSTRACT

Excessive compressive load induces pressure related soft tissue damage, i.e. pressure ulcer (PU), in buttock area in wheelchair users. In solving this problem, our previous study has introduced a concept of Off-Loading sitting, which partially removes the ischial support to reduce pressure under buttocks. However, the effect of this sitting concept has only been evaluated using the interface pressure and tissue perfusion measurements. The objective of this investigation was to evaluate the Off-Loading posture for its ability to reduce internal pressure and stress in deep buttock tissues. This evaluation was performed on a 3D finite element (FE) model which was established and validated in a sitting posture and has realistic material properties and boundary conditions. FE analysis in this study confirmed that the pressure relief provided by Off-Loading posture created profound effect in reducing the mechanical stress within deep tissues. It was concluded that Off-Loading posture may prove beneficial in preventing sitting related PU.


Subject(s)
Buttocks/physiopathology , Models, Biological , Pressure Ulcer/prevention & control , Wheelchairs , Finite Element Analysis , Humans , Posture , Pressure Ulcer/physiopathology , Stress, Mechanical , Weight-Bearing
17.
Arch Phys Med Rehabil ; 88(7): 862-70, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17601466

ABSTRACT

OBJECTIVE: To investigate the relieving effect on interface pressure of an alternate sitting protocol involving a sitting posture that reduces ischial support. DESIGN: Repeated measures in 2 protocols on 3 groups of subjects. SETTING: Laboratory. PARTICIPANTS: Twenty able-bodied persons, 20 persons with paraplegia, and 20 persons with tetraplegia. INTERVENTIONS: Two 1-hour protocols were used: alternate and normal plus pushup. In the alternate protocol, sitting posture was alternated every 10 minutes between normal (sitting upright with ischial support) and with partially removed ischial support (WO-BPS) postures; in the normal plus pushup protocol, sitting was in normal posture with pushups (lifting the subject off the seat) performed every 20 minutes. MAIN OUTCOME MEASURE: Interface pressure on seat and backrest. RESULTS: In WO-BPS posture, the concentrated interface pressure observed around the ischia in normal posture was significantly repositioned to the thighs. By cyclically repositioning the interface pressure, the alternate protocol was superior to the normal plus pushup protocol in terms of a significantly lower average interface pressure over the buttocks. CONCLUSIONS: A sitting protocol periodically reducing the ischial support helps lower the sitting load on the buttocks, especially the area close to ischial tuberosities.


Subject(s)
Ischium/physiology , Posture/physiology , Pressure Ulcer/prevention & control , Weight-Bearing/physiology , Wheelchairs , Adult , Case-Control Studies , Female , Humans , Male , Paraplegia/physiopathology , Pressure , Pressure Ulcer/physiopathology , Quadriplegia/physiopathology
18.
IEEE Trans Neural Syst Rehabil Eng ; 15(4): 517-25, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18198709

ABSTRACT

The interface pressure is currently the only clinical tool to estimate the risk of sitting-related pressure ulcers. However, it provides little information on the loading condition in deep tissues. We present a comprehensive 3-D finite element (FE) model for human buttocks with the consideration of the joint configuration and realistic boundary conditions in a sitting posture. Sitting induced soft tissue deformation, internal pressure, and von-Mises stress were computed. The FE model was well validated qualitatively using actual displacement obtained from magnetic resonance imaging (MRI) images. FE analysis demonstrated that the deformation induced by sitting pressure was substantially different among muscle, fat, and skin. The deformation of the muscle varied with location and the maximum was seen in the regions underneath the bony prominence of ischial tuberosity. In these regions, the range of compressive pressure was 65-80 kPa, 50-60 kPa, and 55-65 kPa, for skin, fat, and muscle, respectively. The von-Mises stress distribution had a similar pattern. In conclusion, this study suggests a new methodology for the development and validation of FE models for investigating the risk of sitting-related soft tissue injury. The proposed model may provide researchers and therapists with a powerful technique for evaluating the effectiveness of various postural modulations in preventing deep tissue ulcers.


Subject(s)
Pressure Ulcer/physiopathology , Buttocks , Femur , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Male , Models, Biological , Muscle, Skeletal/physiopathology , Pelvis , Pressure Ulcer/etiology , Reference Values , Reproducibility of Results
19.
Arch Phys Med Rehabil ; 87(4): 504-9, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16571389

ABSTRACT

OBJECTIVE: To investigate the effect of sitting posture on lung capacity and expiratory flow (LC-EF) and lumbar lordosis. DESIGN: Repeated measures on 1 group of subjects in 4 postures. SETTING: Laboratory. PARTICIPANTS: Seventy able-bodied volunteers. INTERVENTIONS: Postures were assumed randomly: normal, with full ischial support and flat lumbar support; slumped, with the pelvis positioned in the middle of seat while leaning against the backrest; against the back part of the seat without ischial support (WO-BPS), with partially removed ischial support and an enhanced lumbar support; and standing. MAIN OUTCOME MEASURES: For LC-EF, forced vital capacity, maximum forced expiratory flow, forced expiratory volume in 1 second, and peak expiratory flow; and lumbar lordosis. RESULTS: All LC-EF measures in standing were significantly superior to those in slumped and normal sitting, and 4 measures were significantly higher than in WO-BPS. In slumped sitting, LC-EF significantly decreased from that in normal sitting. WO-BPS sitting significantly increased 4 of the LC-EF measures from those in the normal sitting. Lumbar lordosis was the highest in standing and progressively decreased in WO-BPS, normal, and slumped sitting. CONCLUSIONS: Slumped sitting significantly decreased LC-EF and lumbar lordosis. Because it increases the lumbar lordosis and promotes LC-EF, the WO-BPS posture may be a better seating option for people sitting for a prolonged time.


Subject(s)
Lordosis/physiopathology , Lumbar Vertebrae/physiology , Lung Volume Measurements , Peak Expiratory Flow Rate/physiology , Posture/physiology , Wheelchairs , Adult , Analysis of Variance , Female , Humans , Male , Middle Aged
20.
J Biomech ; 38(5): 981-992, 2005 May.
Article in English | MEDLINE | ID: mdl-15844264

ABSTRACT

In this communication, the Standardization and Terminology Committee (STC) of the International Society of Biomechanics proposes a definition of a joint coordinate system (JCS) for the shoulder, elbow, wrist, and hand. For each joint, a standard for the local axis system in each articulating segment or bone is generated. These axes then standardize the JCS. The STC is publishing these recommendations so as to encourage their use, to stimulate feedback and discussion, and to facilitate further revisions. Adopting these standards will lead to better communication among researchers and clinicians.


Subject(s)
Anthropometry/methods , Biomechanical Phenomena/methods , Biomechanical Phenomena/standards , Joints/anatomy & histology , Joints/physiology , Models, Biological , Movement/physiology , Societies, Scientific , Elbow Joint/anatomy & histology , Elbow Joint/physiology , Hand/anatomy & histology , Hand/physiology , Humans , Internationality , Physical Examination/methods , Physical Examination/standards , Range of Motion, Articular/physiology , Reference Standards , Shoulder Joint/anatomy & histology , Shoulder Joint/physiology , Wrist Joint/anatomy & histology , Wrist Joint/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...