Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Indian Prosthodont Soc ; 20(1): 45-51, 2020.
Article in English | MEDLINE | ID: mdl-32089598

ABSTRACT

AIM: The present study was done to evaluate and compare the stability of the implant and the loss of crestal bone in the implants placed using OD drilling and traditional drilling technique. SETTING AND DESIGN: In vivo-comparative study. MATERIALS AND METHODS: A total of 20 implants were placed in the anterior maxilla, and the patients were divided into two groups. In Group I, the implants were placed using traditional drilling technique, and in Group II, implant placement was done using OD drilling technique. Primary stability was measured in both the groups at baseline (immediate postoperative), and at an interval of 6 months, while crestal bone levels were measured at baseline, 6, and 8 months. STATISTICAL ANALYSIS USED: The data obtained were subjected to unpaired t-test to make intergroup comparisons, while one-way ANOVA F-test was used to make intragroup comparisons. RESULTS: The primary stability of implant placed using OD drills was found to be slightly higher than implant placed with traditional drilling; however, there was no statistical significance (P > 0.05). When the data obtained for crestal bone levels were statistically analyzed, no significant difference between the two groups was obtained (P > 0.05). CONCLUSION: Within the limitations of this study following conclusions were drawn: there was no statistically significant difference in implant stability between the traditional drilling and OD drilling (P < 0.05). On comparison of crestal bone levels between OD and traditional drilling, no statistically significant difference was found between the two groups (P < 0.05).

2.
J Clin Diagn Res ; 10(4): ZC05-8, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27190938

ABSTRACT

INTRODUCTION: Edentulous patients show some significant changes in ridge relationship caused by resorption of alveolar ridge. The changes are characterized by an upward rotation of mandible, increase in mandibular prognathism that ultimately results in change of natural head posture. AIM: This clinical study was planned to know the effect of complete denture on head posture in different age groups of Indian completely edentulous population, after placement of complete denture at various time intervals. MATERIALS AND METHODS: The sample consisted of completely edentulous patients without previous experience of the dentures. They were divided into 2 age groups: Group A (45-60) and Group B (61-75). During placement of complete denture craniovertical angle was measured with the help of custom made ruler protector device. Readings were taken before denture placement, immediately after denture placement, 30 minutes, 24 hours and 30 days after dentures placement. RESULTS: The results of this study indicated that in most of the patients (90%) despite their age, change in head posture (extension) occurred immediately after the denture placement. Thereafter reading remains same for measurement at 30 minutes and 24 hours of denture placement. However after 30 days, observation revealed that all the patients showed reduced craniovertical angle (flexion). Even though the values of craniovertical angle remain higher than its baseline in both groups, significant changes were noticed only in Group A. CONCLUSION: Findings revealed that head posture was significantly altered by the placement of dentures in completely edentulous patients. Within the time interval of 30 minutes and 24 hours extension of head posture remained constant with slight variation. Although after 30 days, changes remained significant for group 'A', but no significant changes were observed in the subjects of group 'B'.

3.
Dent Update ; 40(9): 758-60, 763-4, 767-8, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24386768

ABSTRACT

UNLABELLED: Many materials are available for the fabrication of indirect restorations such as, metal alloys, resin-based composites and ceramics. Resin cements have long been valued as luting agents for indirect restorations because of their high retentive strength, resistance to wear, and low solubility. However, one of the common discouraging factors regarding their chairside use is the need of multiple-steps (etching, drying, priming and luting) for bonding. Thus the current impetus is towards the use of self-adhesive cements that require no etching, priming or bonding agents to bond to the tooth surface. Their increased popularity can be judged by the commercial availability of more than a dozen self-adhesive resin products/brands, in a short span of time. This article reviews the composition, physical and biological properties, adhesion characteristics and clinical performance of self-adhesive (resin) cements. CLINICAL RELEVANCE: Self-adhesive resin cements are dual-cured and adhere to tooth structure without the requirement of a separate etching step and application of an adhesive/bonding agent.


Subject(s)
Dental Bonding/methods , Resin Cements/chemistry , Adhesiveness , Chemical Phenomena , Humans , Self-Curing of Dental Resins , Stress, Mechanical , Technology, Dental , Time Factors
4.
J Indian Prosthodont Soc ; 12(2): 101-7, 2012 Jun.
Article in English | MEDLINE | ID: mdl-23858283

ABSTRACT

Tissue integrated oral implants have initiated a new perspective in oral rehabilitation of tumor patients who have had undergone surgical resection procedure. The present case demonstrated a simple and predictable approach to rehabilitate a patient who had partial maxillectomy using dental implants. The use of an implant in conjunction with hollow bulb obturator shared remarkable improvement in retention and stability of the existing complete denture prosthesis.

5.
J Indian Prosthodont Soc ; 10(3): 190-3, 2010 Sep.
Article in English | MEDLINE | ID: mdl-21886412

ABSTRACT

The fundamental objective in restoring a congenital as well as acquired defect of eye with an ocular prosthesis is to enable the patient to cope better with the difficult process of rehabilitation after an enucleation or evisceration. A cosmetically acceptable prosthesis is that reproduces the color, form and orientation of iris and allows the patient to return to accustomed lifestyle. A sequence of steps for construction of custom-made ocular prostheses is outlined in this case report using the advantages of digital imaging technique.

SELECTION OF CITATIONS
SEARCH DETAIL
...