Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 20(13)2020 Jun 28.
Article in English | MEDLINE | ID: mdl-32605285

ABSTRACT

An iterative algorithm is proposed for determining the optimal chassis design of an electric vehicle, given a path and a reference time. The proposed algorithm balances the capacity of the battery pack and the dynamic properties of the chassis, seeking to optimize the tradeoff between the mass of the vehicle, its energy consumption, and the travel time. The design variables of the chassis include geometrical and inertial values, as well as the characteristics of the powertrain. The optimization is constrained by the slopes, curves, grip, and posted speeds of the different sections of the track. Particular service constraints are also considered, such as limiting accelerations due to passenger comfort or cargo safety. This methodology is applicable to any vehicle whose route and travel time are known in advance, such as delivery vehicles, buses, and race cars, and has been validated using telemetry data from an internal combustion rear-wheel drive race car designed for hill climb competitions. The implementation of the proposed methodology allows to reduce the weight of the battery pack by up to 20%, compared to traditional design methods.

2.
Sensors (Basel) ; 15(1): 2006-20, 2015 Jan 16.
Article in English | MEDLINE | ID: mdl-25602272

ABSTRACT

An agricultural implement for underground application of rodenticide bait to control the Mediterranean pocket gopher (Microtus Duodecimcostatus) in fruit orchards has been designed and tested. The main objective of this research was to design and test the implement by using the finite element method (FEM) and considering a range of loads generated on most commonly used furrow openers in agricultural implements. As a second step, the prototype was tested in the field by analysing the effects of forward speed and application depth on the mechanical behaviour of the implement structure. The FEM was used in the design phase and a prototype was manufactured. The structural strains on the prototype chassis under working conditions were tested by using strain gauges to validate the design phase. Three forward speeds (4.5, 5.5, and 7.0 km/h), three application depths (0.12, 0.15, and 0.17 m), and two types of soil (clayey-silty-loam and clayey-silty-sandy) were considered. The prototype was validated successfully by analysing the information obtained from the strain gauges. The Von Mises stresses indicated a safety coefficient of 1.9 for the most critical load case. Although both forward speed and application depth had a significant effect on the stresses generated on the chassis, the latter parameter critically affected the structural behaviour of the implement. The effects of the application depth on the strains were linear such that strains increased with depth. In contrast, strains remained roughly constant regardless of variation in the forward speed.


Subject(s)
Agriculture , Rodenticides/analysis , Confidence Intervals , Finite Element Analysis , Numerical Analysis, Computer-Assisted , Soil/chemistry , Stress, Mechanical
3.
Sensors (Basel) ; 15(2): 2399-418, 2015 Jan 22.
Article in English | MEDLINE | ID: mdl-25621611

ABSTRACT

A computational fluid dynamics (CFD) model of the air flow generated by an air-assisted sprayer equipped with two axial fans was developed and validated by practical experiments in the laboratory. The CFD model was developed by considering the total air flow supplied by the sprayer fan to be the main parameter, rather than the outlet air velocity. The model was developed for three air flows corresponding to three fan blade settings and assuming that the sprayer is stationary. Actual measurements of the air velocity near the sprayer were taken using 3D sonic anemometers. The workspace sprayer was divided into three sections, and the air velocity was measured in each section on both sides of the machine at a horizontal distance of 1.5, 2.5, and 3.5 m from the machine, and at heights of 1, 2, 3, and 4 m above the ground The coefficient of determination (R2) between the simulated and measured values was 0.859, which demonstrates a good correlation between the simulated and measured data. Considering the overall data, the air velocity values produced by the CFD model were not significantly different from the measured values.

4.
Sensors (Basel) ; 12(6): 7598-613, 2012.
Article in English | MEDLINE | ID: mdl-22969363

ABSTRACT

The flow of air generated by a new design of air assisted sprayer equipped with two axial fans of reversed rotation was analyzed. For this goal, a 3D sonic anemometer has been used (accuracy: 1.5%; measurement range: 0 to 45 m/s). The study was divided into a static test and a dynamic test. During the static test, the air velocity in the working vicinity of the sprayer was measured considering the following machine configurations: (1) one activated fan regulated at three air flows (machine working as a traditional sprayer); (2) two activated fans regulated at three air flows for each fan. In the static test 72 measurement points were considered. The location of the measurement points was as follow: left and right sides of the sprayer; three sections of measurement (A, B and C); three measurement distances from the shaft of the machine (1.5 m, 2.5 m and 3.5 m); and four measurement heights (1 m, 2 m, 3 m and 4 m). The static test results have shown significant differences in the module and the vertical angle of the air velocity vector in function of the regulations of the sprayer. In the dynamic test, the air velocity was measured at 2.5 m from the axis of the sprayer considering four measurement heights (1 m, 2 m, 3 m and 4 m). In this test, the sprayer regulations were: one or two activated fans; one air flow for each fan; forward speed of 2.8 km/h. The use of one fan (back) or two fans (back and front) produced significant differences on the duration of the presence of wind in the measurement point and on the direction of the air velocity vector. The module of the air velocity vector was not affected by the number of activated fans.

SELECTION OF CITATIONS
SEARCH DETAIL
...