Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 10(2)2020 Jan 31.
Article in English | MEDLINE | ID: mdl-32023980

ABSTRACT

Accurate clinical evaluation of renal osteodystrophy (ROD) is currently accomplished using invasive in vivo transiliac bone biopsy, followed by in vitro histomorphometry. In this study, we demonstrate that an alternative method for ROD assessment is through a fast, label-free Raman recording of multiple biomarkers combined with computational analysis for predicting the minimally required number of spectra for sample classification at defined accuracies. Four clinically relevant biomarkers: the mineral-to-matrix ratio, the carbonate-to-matrix ratio, phenylalanine, and calcium contents were experimentally determined and simultaneously considered as input to a linear discriminant analysis (LDA). Additionally, sample evaluation was performed with a linear support vector machine (LSVM) algorithm, with a 300 variable input. The computed probabilities based on a single spectrum were only marginally different (~80% from LDA and ~87% from LSVM), both providing an unacceptable classification power for a correct sample assignment. However, the Type I and Type II assignment errors confirm that a relatively small number of independent spectra (7 spectra for Type I and 5 spectra for Type II) is necessary for a p < 0.05 error probability. This low number of spectra supports the practicality of future in vivo Raman translation for a fast and accurate ROD detection in clinical settings.

2.
Appl Opt ; 45(19): 4563-6, 2006 Jul 01.
Article in English | MEDLINE | ID: mdl-16799665

ABSTRACT

A method for producing stabilized interference patterns for ultraviolet interference lithography using a CCD camera as the detector element is described. Intensity data obtained from the CCD element are filtered in software to minimize speckle and detector noise effects as well as to determine the relative phase of the interfering beams. A control signal is then issued to correct the fringe drift. The system allows rapid reconfiguration of the lithography setup with minimum realignment of optical components.

3.
Opt Lett ; 29(10): 1108-10, 2004 May 15.
Article in English | MEDLINE | ID: mdl-15182001

ABSTRACT

Experimental results on resonantly excited second-harmonic generation (SHG) in a periodic ionically self-assembled monolayer (ISAM) film are reported. A double-layer guided-mode resonance filter (GMRF) structure is coated with 40 bilayers of pyrlium-based chi(2) ISAM thin film and excited with the fundamental of a Nd:YAG laser. Enhanced second-harmonic conversion in the ISAM film is achieved because of the local field enhancement associated with the fundamental resonating leaky mode. This method of SHG is particularly promising, as the ISAM films under investigation exhibit anomalous dispersion that may be applied for phase matching to improve nonlinear conversion efficiency.

SELECTION OF CITATIONS
SEARCH DETAIL
...