Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters











Publication year range
1.
Arq Neuropsiquiatr ; 82(1): 1-8, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38316425

ABSTRACT

BACKGROUND: Infectious meningoencephalitis is a potentially fatal clinical condition that causes inflammation of the central nervous system secondary to the installation of different microorganisms. The FilmArray meningitis/encephalitis panel allows the simultaneous detection of 14 pathogens with results in about one hour. OBJECTIVE: This study is based on retrospectively evaluating the implementation of the FilmArray meningitis/encephalitis panel in a hospital environment, highlighting the general results and, especially, analyzing the consistency of the test results against the clinical and laboratory conditions of the patients. METHODS: Data were collected through the results reported by the BioFire FilmArray system software from the meningitis/encephalitis panel. The correlated laboratory tests used in our analysis, when available, included biochemical, cytological, direct and indirect microbiological tests. RESULTS: In the analyzed period, there were 496 samples with released results. Of the total of 496 samples analyzed, 88 (17.75%) were considered positive, and 90 pathogens were detected, and in 2 of these (2.27%) there was co-detection of pathogens. Viruses were the agents most frequently found within the total number of pathogens detected. Of the 496 proven samples, 20 (4.03%) were repeated, 5 of which were repeated due to invalid results, 6 due to the detection of multiple pathogens and 9 due to disagreement between the panel results and the other laboratory tests and/or divergence of the clinical-epidemiological picture. Of these 20 repeated samples, only 4 of them (20%) maintained the original result after repeating the test, with 16 (80%) being non-reproducible. The main factor related to the disagreement of these 16 samples during retesting was the detection of bacterial agents without any relationship with other laboratory tests or with the patients' clinical condition. CONCLUSION: In our study, simply reproducing tests with atypical results from the FilmArray meningitis/encephalitis panel proved, in most cases, effective and sufficient for interpreting these results.


ANTECEDENTES: A meningoencefalite infecciosa é uma condição clínica potencialmente fatal que causa inflamação do sistema nervoso central secundária à instalação de diversos microrganismos. O painel de meningite/encefalite FilmArray permite a detecção simultânea de 14 patógenos, com resultados em cerca de uma hora. OBJETIVO: Este estudo baseia-se em avaliar retrospectivamente a implementação do painel de meningite/encefalite FilmArray em ambiente hospitalar, destacando os resultados gerais e, principalmente, analisando a consistência dos resultados do teste frente às condições clínicas e laboratoriais dos pacientes. MéTODOS: Os dados foram coletados por meio dos resultados relatados pelo software do sistema BioFire FilmArray do painel de meningite/encefalite. Os exames laboratoriais correlacionados utilizados em nossa análise, quando disponíveis, incluíram exames bioquímicos, citológicos, microbiológicos diretos e indiretos. RESULTADOS: No período analisado, foram 496 amostras com resultados divulgados. Do total de 496 amostras analisadas, 88 (17,75%) foram consideradas positivas e 90 patógenos foram detectados, sendo que em duas destas (2,27%) houve codetecção de patógenos. Os vírus foram os agentes mais frequentemente encontrados dentro do total de patógenos detectados. Das 496 amostras analisadas, 20 (4,03%) foram repetidas, sendo 5 repetidas por resultado inválido, 6 pela detecção de múltiplos patógenos e 9 por discordância dos resultados do painel com os demais exames laboratoriais e/ou divergência do quadro clínico-epidemiológico. Destas 20 amostras repetidas, apenas 4 delas (20%) mantiveram o resultado original após a repetição do teste, sendo 16 (80%) não reprodutíveis. O principal fator relacionado à discordância destas 16 amostras na retestagem foi a detecção de agentes bacterianos sem qualquer relação com os demais exames laboratoriais ou com o quadro clínico dos pacientes. CONCLUSãO: Em nosso estudo, a simples repetição dos testes com resultados atípicos do painel de meningite/encefalite FilmArray mostrou-se, na maior dos casos, efetiva e suficiente para a interpretação destes achados.


Subject(s)
Encephalitis , Meningitis , Viruses , Humans , Meningitis/diagnosis , Meningitis/complications , Encephalitis/diagnosis , Encephalitis/etiology , Retrospective Studies , Inflammation
2.
Arq. neuropsiquiatr ; Arq. neuropsiquiatr;82(1): s00441779035, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533830

ABSTRACT

Abstract Background Infectious meningoencephalitis is a potentially fatal clinical condition that causes inflammation of the central nervous system secondary to the installation of different microorganisms. The FilmArray meningitis/encephalitis panel allows the simultaneous detection of 14 pathogens with results in about one hour. Objective This study is based on retrospectively evaluating the implementation of the FilmArray meningitis/encephalitis panel in a hospital environment, highlighting the general results and, especially, analyzing the consistency of the test results against the clinical and laboratory conditions of the patients. Methods Data were collected through the results reported by the BioFire FilmArray system software from the meningitis/encephalitis panel. The correlated laboratory tests used in our analysis, when available, included biochemical, cytological, direct and indirect microbiological tests. Results In the analyzed period, there were 496 samples with released results. Of the total of 496 samples analyzed, 88 (17.75%) were considered positive, and 90 pathogens were detected, and in 2 of these (2.27%) there was co-detection of pathogens. Viruses were the agents most frequently found within the total number of pathogens detected. Of the 496 proven samples, 20 (4.03%) were repeated, 5 of which were repeated due to invalid results, 6 due to the detection of multiple pathogens and 9 due to disagreement between the panel results and the other laboratory tests and/or divergence of the clinical-epidemiological picture. Of these 20 repeated samples, only 4 of them (20%) maintained the original result after repeating the test, with 16 (80%) being non-reproducible. The main factor related to the disagreement of these 16 samples during retesting was the detection of bacterial agents without any relationship with other laboratory tests or with the patients' clinical condition. Conclusion In our study, simply reproducing tests with atypical results from the FilmArray meningitis/encephalitis panel proved, in most cases, effective and sufficient for interpreting these results.


Resumo Antecedentes A meningoencefalite infecciosa é uma condição clínica potencialmente fatal que causa inflamação do sistema nervoso central secundária à instalação de diversos microrganismos. O painel de meningite/encefalite FilmArray permite a detecção simultânea de 14 patógenos, com resultados em cerca de uma hora. Objetivo Este estudo baseia-se em avaliar retrospectivamente a implementação do painel de meningite/encefalite FilmArray em ambiente hospitalar, destacando os resultados gerais e, principalmente, analisando a consistência dos resultados do teste frente às condições clínicas e laboratoriais dos pacientes. Métodos Os dados foram coletados por meio dos resultados relatados pelo software do sistema BioFire FilmArray do painel de meningite/encefalite. Os exames laboratoriais correlacionados utilizados em nossa análise, quando disponíveis, incluíram exames bioquímicos, citológicos, microbiológicos diretos e indiretos. Resultados No período analisado, foram 496 amostras com resultados divulgados. Do total de 496 amostras analisadas, 88 (17,75%) foram consideradas positivas e 90 patógenos foram detectados, sendo que em duas destas (2,27%) houve codetecção de patógenos. Os vírus foram os agentes mais frequentemente encontrados dentro do total de patógenos detectados. Das 496 amostras analisadas, 20 (4,03%) foram repetidas, sendo 5 repetidas por resultado inválido, 6 pela detecção de múltiplos patógenos e 9 por discordância dos resultados do painel com os demais exames laboratoriais e/ou divergência do quadro clínico-epidemiológico. Destas 20 amostras repetidas, apenas 4 delas (20%) mantiveram o resultado original após a repetição do teste, sendo 16 (80%) não reprodutíveis. O principal fator relacionado à discordância destas 16 amostras na retestagem foi a detecção de agentes bacterianos sem qualquer relação com os demais exames laboratoriais ou com o quadro clínico dos pacientes. Conclusão Em nosso estudo, a simples repetição dos testes com resultados atípicos do painel de meningite/encefalite FilmArray mostrou-se, na maior dos casos, efetiva e suficiente para a interpretação destes achados.

3.
Curr Microbiol ; 80(7): 231, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37261596

ABSTRACT

Among healthcare-associated infections that can affect a critically ill patient, bloodstream infections are one of the most frequent causes of mortality, especially in hospitalized patients. The objective of this work is to evaluate the performance of the XGEN Multi Sepsis Flow Chip for the rapid diagnosis of bloodstream infections compared with conventional tests. In total, 101 positive blood culture samples were included, and the results obtained by the phenotypic conventional method (culture with susceptibility profile) were compared with results obtained by the XGEN Multi Sepsis Flow Chip. This molecular assay allows the simultaneous detection of the main bloodstream infection pathogens, and their most common antibiotic resistance markers in a short period of time. It was possible to observe substantial agreement between the methods for identifying the genus of pathogens. Considering species, the agreement was excellent. In relation to susceptibility, excellent agreement was noted between the detected resistance genes and susceptibility profile obtained through conventional antibiograms. The evaluated assay presented very early and satisfactory results for identification and detection of resistance genes of the main pathogens involved in bloodstream infections.


Subject(s)
Bacteremia , Cross Infection , Sepsis , Humans , Sepsis/diagnosis , Microbial Sensitivity Tests , Early Diagnosis , Oligonucleotide Array Sequence Analysis , Anti-Bacterial Agents , Bacteremia/diagnosis
4.
Microbiol Spectr ; 10(5): e0019022, 2022 10 26.
Article in English | MEDLINE | ID: mdl-36036635

ABSTRACT

This study evaluated the BD Veritor system for rapid detection of SARS-CoV-2, an immunochromatographic point-of-care test, by comparing it with a standard reverse transcription-PCR (RT-PCR) methodology using samples from symptomatic patients. Samples from 146 symptomatic and 2 asymptomatic patients between the 1st and the 40th day of infection were evaluated. The nasopharyngeal and/or oropharyngeal swabs were inserted in a tube containing 0.9% saline solution and stored at refrigerator temperature until the moment of use. The samples were first tested with the Xpert Xpress SARS-CoV-2 (GeneXpert) kit (RT-PCR method), and the cycle thresholds (CTs) for the E and N2 genes encoding the SARS-CoV-2 envelope and nucleoprotein, respectively, were established. Subsequently, the same samples were tested using the Veritor rapid test. We analyzed the CTs of the N2 gene, which is detected in both methodologies, and observed sensitivities of 100%, 98.8%, 89.6%, and 82.7% for the CTs of <25, <27, and <30 and all the CTs, respectively. The greatest sensitivity was observed when we performed the test on patients within 5 days of symptom onset. The BD Veritor system's workflow is simple and fast, taking approximately 16 min from sample preparation to obtaining the test result. In addition to its satisfactory sensitivity, with results that correlate with those of the RT-PCR, the BD Veritor analyzer instrument reduces the subjectivity of unaided visual readings and consequent potential variation in result interpretation. Therefore, our results showed that the BD Veritor diagnostic test can provide a rapid and accurate diagnosis for SARS-CoV-2. IMPORTANCE This study provides important and useful information, especially for diagnostic laboratories, since the results show that the BD Veritor system can provide a fast and safe point-of-care antigen diagnostic test for rapid detection of COVID-19 that has high sensitivity, reproducibility, and accuracy.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Reverse Transcription , Reproducibility of Results , Saline Solution , Sensitivity and Specificity , Polymerase Chain Reaction , Nucleoproteins/genetics
5.
Mycoses ; 65(4): 449-457, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35174567

ABSTRACT

BACKGROUND: COVID-19 patients on mechanical ventilation are at risk to develop invasive aspergillosis. To provide additional data regarding this intriguing entity, we conducted a retrospective study describing risk factors, radiology and prognosis of this emerging entity in a Brazilian referral centre. METHODS: This retrospective study included intubated (≥18 years) patients with COVID-19 admitted from April 2020 until July 2021 that had bronchoscopy to investigate pulmonary co-infections. COVID-19-associated aspergillosis (CAPA) was defined according to the 2020 European Confederation of Medical Mycology/International Society of Human and Animal Mycosis consensus criteria. The performance of tracheal aspirate (TA) cultures to diagnose CAPA were described, as well as the radiological findings, risk factors and outcomes. RESULTS: Fourteen patients (14/87, 16%) had probable CAPA (0.9 cases per 100 ICU admissions). The sensitivity, specificity, positive predictive value and negative predictive value of TA for the diagnosis of CAPA were 85.7%, 73.1%, 46.2% and 95% respectively. Most of the radiological findings of CAPA were classified as typical of invasive pulmonary aspergillosis (64.3%). The overall mortality rate of probable CAPA was 71.4%. Age was the only independent risk factor for CAPA [p = .03; odds ratio (OR) 1.072]. CAPA patients under renal replacement therapy (RRT) may have a higher risk for a fatal outcome (p = .053, hazard ratio 8.047). CONCLUSIONS: CAPA was a prevalent co-infection in our cohort of patients under mechanical ventilation. Older patients had a higher risk to develop CAPA, and a poor prognosis may be associated with RRT.


Subject(s)
COVID-19 , Invasive Pulmonary Aspergillosis , Animals , Brazil/epidemiology , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/microbiology , COVID-19/therapy , Humans , Intubation , Invasive Pulmonary Aspergillosis/diagnosis , Invasive Pulmonary Aspergillosis/epidemiology , Invasive Pulmonary Aspergillosis/therapy , Invasive Pulmonary Aspergillosis/virology , Referral and Consultation , Retrospective Studies , Risk Factors , SARS-CoV-2/isolation & purification
6.
Einstein (Sao Paulo) ; 19: eRC6369, 2021.
Article in English, Portuguese | MEDLINE | ID: mdl-34909977

ABSTRACT

During the COVID-19 pandemic, a case of a long-term persistence of SARS-CoV-2 infection (from March 26 to May 20, 2020) was identified at a private hospital in São Paulo, SP, Brazil. The long-term positivity for SARS-CoV-2 in reverse transcriptase polymerase chain reaction tests of a patient diagnosed with COVID-19 suggests, at least part of patients who recovered, may still carry and transmit the SARS-CoV-2 virus. This fact emphasizes the importance of having at least two negative reverse transcriptase polymerase chain reaction test results for SARS-CoV-2. Serological assays were not particularly helpful in the case described, since the patient had very low antibodies titers at the end of the follow-up period. Low viral loads may not be detected by current molecular methods, leading to wrong conclusions regarding viral clearance.


Subject(s)
COVID-19 , Brazil , Humans , Pandemics , SARS-CoV-2 , Serologic Tests
7.
BMJ Open ; 11(7): e045852, 2021 07 09.
Article in English | MEDLINE | ID: mdl-34244259

ABSTRACT

INTRODUCTION: Acute viral hepatitis is a disease of great clinical importance. This study proposes actions to better characterise cases of acute hepatitis in Brazil and to provide relevant information to institutionalised health policies within the Unified Health System. Available data on acute hepatitis in Brazil need to be re-evaluated regarding the different hepatotropic agent (hepatitis A to E virus) frequencies, as well as other agents that can cause similar clinical conditions, such as Herpes Simplex Virus 1 and 2(HSV1, HSV2), Varicella Zoster Virus (VZV), Cytomegalovirus (CMV), Epstein Barr Virus (EBV), Human Herpes Virus 6 and 7 (HHV6, HHV7), arbovirus (yellow fever, dengue, chikungunya, Zika), parvovirus B19, adenovirus, parechovirus, enterovirus, HIV, leptospirosis, toxoplasmosis and syphilis, in addition to autoimmune hepatitis. In this context, the primary aim of this study is the clinical-epidemiological and molecular characterisation of acute viral hepatitis in Brazilian health services from all geographical regions of the country. The present article describes the study protocol. METHODS AND ANALYSIS: This study will evaluate 2280 patients with symptoms and/or signs suggestive of acute liver disease in Brazilian health institutions in all five geographic Brazilian regions. Demographic, epidemiological and clinical data will be collected, as well as blood samples to be analysed at Hospital Israelita Albert Einstein Clinical Laboratory. ETHICS AND DISSEMINATION: Ethics approval was obtained at the national research ethics committee (Conselho Nacional de Ética em Pesquisa- CONEP-CAAE 00952818.4.1001.0071) and at all participating sites. Results will be published in journals and presented at scientific meetings.


Subject(s)
Epstein-Barr Virus Infections , Hepatitis, Viral, Human , Zika Virus Infection , Zika Virus , Brazil/epidemiology , Health Services , Hepatitis, Viral, Human/epidemiology , Herpesvirus 4, Human , Humans
8.
Einstein (São Paulo, Online) ; 19: eRC6369, 2021. tab, graf
Article in English | LILACS | ID: biblio-1350703

ABSTRACT

ABSTRACT During the COVID-19 pandemic, a case of a long-term persistence of SARS-CoV-2 infection (from March 26 to May 20, 2020) was identified at a private hospital in São Paulo, SP, Brazil. The long-term positivity for SARS-CoV-2 in reverse transcriptase polymerase chain reaction tests of a patient diagnosed with COVID-19 suggests, at least part of patients who recovered, may still carry and transmit the SARS-CoV-2 virus. This fact emphasizes the importance of having at least two negative reverse transcriptase polymerase chain reaction test results for SARS-CoV-2. Serological assays were not particularly helpful in the case described, since the patient had very low antibodies titers at the end of the follow-up period. Low viral loads may not be detected by current molecular methods, leading to wrong conclusions regarding viral clearance.


RESUMO Durante a pandemia da COVID-19, um caso de persistência de longo prazo de infecção por SARS-CoV-2, de 26 de março a 20 de maio de 2020, foi identificado em um hospital privado localizado em São Paulo, SP, Brasil. A positividade de longo prazo para SARS-CoV-2 nos exames de reação em cadeia da polimerase via transcriptase reversa de uma paciente diagnosticada com COVID-19 sugere que parte dos pacientes que se recuperaram podem ser portadores e transmitir o SARS-CoV-2. Esse fato enfatiza a importância da obtenção de pelo menos dois resultados negativos para SARS-CoV-2 no exame de reação em cadeia da polimerase via transcriptase reversa. Os ensaios sorológicos não foram de grande utilidade no caso descrito, uma vez que a paciente apresentava baixos títulos de anticorpos no final do período de acompanhamento. Baixas cargas virais podem não ser detectadas pelos métodos moleculares vigentes, levando a conclusões equivocadas a respeito da eliminação do vírus.


Subject(s)
Humans , COVID-19 , Brazil , Serologic Tests , Pandemics , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL