Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Microbiol ; 80(7): 231, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37261596

ABSTRACT

Among healthcare-associated infections that can affect a critically ill patient, bloodstream infections are one of the most frequent causes of mortality, especially in hospitalized patients. The objective of this work is to evaluate the performance of the XGEN Multi Sepsis Flow Chip for the rapid diagnosis of bloodstream infections compared with conventional tests. In total, 101 positive blood culture samples were included, and the results obtained by the phenotypic conventional method (culture with susceptibility profile) were compared with results obtained by the XGEN Multi Sepsis Flow Chip. This molecular assay allows the simultaneous detection of the main bloodstream infection pathogens, and their most common antibiotic resistance markers in a short period of time. It was possible to observe substantial agreement between the methods for identifying the genus of pathogens. Considering species, the agreement was excellent. In relation to susceptibility, excellent agreement was noted between the detected resistance genes and susceptibility profile obtained through conventional antibiograms. The evaluated assay presented very early and satisfactory results for identification and detection of resistance genes of the main pathogens involved in bloodstream infections.


Subject(s)
Bacteremia , Cross Infection , Sepsis , Humans , Sepsis/diagnosis , Microbial Sensitivity Tests , Early Diagnosis , Oligonucleotide Array Sequence Analysis , Anti-Bacterial Agents , Bacteremia/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...