Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Acta Radiol ; 58(10): 1189-1197, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28132531

ABSTRACT

Background Breast elastography is a non-invasive and widely accessible method used in the differential diagnostic procedure in addition to B-mode imaging. Purpose To assess the role of elastographic features in the differentiation of breast lesions and to evaluate the importance of depth in the choice of reference fat tissue for the calculation of strain ratio. Material and Methods From January to August 2015, 242 breast lesions were evaluated using elastographic assessment based on qualitative and semi-quantitative parameters (color map, strain ratio, length ratio) as well as elastographic analysis. Histological findings were considered as gold-standard. Results Sensitivity and specificity of B-mode ultrasound imaging were 90% and 60%, respectively. Color map sensitivity was 98% and specificity 46%; strain ratio sensitivity 81% and specificity 70%; length ratio sensitivity 64% and specificity 76%. Combined analysis of these three elastographic features improved the overall diagnostic performance of any of the three parameters alone, yielded sensitivity similar to that of color map (95%) and specificity comparable to strain ratio and length ratio (70%). There was no significant difference in strain ratio obtained from the reference fat tissue at the same depth as the lesion and at a different depth (sensitivity 77% versus 84%; specificity 70% versus 68%; P < 0.001). Conclusion In our experience, elastography can improve ultrasound characterization of the lesion, particularly if elastographic analysis is performed.


Subject(s)
Breast Neoplasms/diagnostic imaging , Elasticity Imaging Techniques/methods , Ultrasonography, Mammary/methods , Adult , Aged , Aged, 80 and over , Breast/diagnostic imaging , Diagnosis, Differential , Female , Humans , Middle Aged , ROC Curve , Reproducibility of Results , Sensitivity and Specificity , Young Adult
2.
Eur J Radiol ; 83(3): 420-8, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23763859

ABSTRACT

Thyroid pathology including thyroid nodules and diffuse thyroid diseases represents often a diagnosing challenge for clinicians. US, although highly accurate in identifying thyroid nodules and diffuse thyroid diseases, is still not sufficiently accurate to evaluate them. US-elastography has been introduced in order to further increase US accuracy in many fields and eventually for thyroid disease. The aim of the present paper it to provide an update of the literature on different available techniques and the results reported both for thyroid nodules differentiation and for diffuse thyroid disease evaluation. Advantages and limitations of elastography are also discussed.


Subject(s)
Elasticity Imaging Techniques/methods , Image Enhancement/methods , Thyroid Diseases/diagnostic imaging , Thyroid Diseases/physiopathology , Thyroid Gland/diagnostic imaging , Thyroid Gland/physiopathology , Elastic Modulus , Humans
3.
Eur J Radiol ; 83(3): 429-37, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23787274

ABSTRACT

Breast elastography is a new sonographic imaging technique for the characterization of focal breast lesions in addition to conventional ultrasonography (US) and mammography. Elastography provides a non-invasive evaluation of the stiffness of a lesion. Two different technical approaches are available for clinical use: free-hand elastography (USE) and shear wave elastography (SWE). Initial results of these techniques in clinical trials suggest that elastography substantially improves the US capability in differentiating benign from malignant breast lesions, thus reducing the number of breast biopsies in benign nodules. This review paper, based on an extensive literature search, highlights the basics of breast elastography, including main technical features, how to do suggestions, limit and pitfalls, and presents the results of major clinical studies.


Subject(s)
Breast Diseases/diagnostic imaging , Breast Diseases/physiopathology , Breast/physiopathology , Image Enhancement/methods , Ultrasonography, Mammary/methods , Elastic Modulus , Female , Humans
4.
Tumori ; 99(3): e84-7, 2013.
Article in English | MEDLINE | ID: mdl-24158087

ABSTRACT

Metastatic carcinomas to the thyroid are rare in daily clinical practice. However, when encountered they represent a diagnostic challenge, since it is difficult to distinguish them from primary thyroid lesions, especially when occurring in patients with occult malignant history. Nevertheless, it is critical to differentiate a metastatic tumor from primary thyroid lesions, as the clinical management and the prognosis are different for the two entities. More recently, elastosonography opened new possibilities to ultrasound in different fields, such as thyroid nodule differentiation. Herein, we report a case of metastatic signet ring cell carcinoma to the thyroid studied with quantitative elastography and acoustic radiation force impulse imaging.


Subject(s)
Carcinoma, Signet Ring Cell/diagnostic imaging , Carcinoma, Signet Ring Cell/secondary , Elasticity Imaging Techniques/methods , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Biopsy, Fine-Needle , Diagnosis, Differential , Fatal Outcome , Humans , Male , Middle Aged , Tomography, X-Ray Computed
5.
Radiol Med ; 118(6): 995-1010, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23801388

ABSTRACT

PURPOSE: The aim of our study was to assess the diagnostic accuracy of acoustic structure quantification (ASQ) ultrasound software in estimating the degree of hepatic fibrosis compared to Fibroscan and liver biopsy. MATERIALS AND METHODS: Seventy-seven patients with chronic viral hepatitis B and C underwent standard ultrasound examination, ASQ, Fibroscan and liver biopsy. ASQ analysis was conducted by placing a single region of interest (ROI) on each image captured, and calculating mode, average and standard deviation. The sonographic technique was developed through a preliminary evaluation of 20 healthy volunteers. RESULTS: The area under the receiver operating characteristic (AUROC) curve for the diagnosis of cirrhosis (F≥4) with ASQ was 0.77, whereas for the diagnosis of any degree of fibrosis (F≥1) it was 0.71. The AUROC for the diagnosis of cirrhosis (F≥4) with Fibroscan was 0.98, while for the diagnosis of any degree of fibrosis (F≥1) it was 0.94. The difference between the AUROC was statistically significant (p<0.05). CONCLUSIONS: ASQ is a promising new ultrasound software programme which offers encouraging results in the diagnosis of both liver cirrhosis (F=4) and fibrosis (F≥1). However, to date it has not attained the same level of diagnostic performance as Fibroscan.


Subject(s)
Elasticity Imaging Techniques/methods , Hepatitis B, Chronic/diagnostic imaging , Hepatitis C, Chronic/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Liver Cirrhosis/diagnostic imaging , Software , Adult , Aged , Biopsy , Female , Hepatitis B, Chronic/pathology , Hepatitis C, Chronic/pathology , Humans , Liver Cirrhosis/virology , Liver Function Tests , Male , Middle Aged , Sensitivity and Specificity
6.
Radiol Med ; 118(6): 1011-21, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23807669

ABSTRACT

PURPOSE: This study was done to compare quantitative elastosonography and ultrasound analysis in the characterisation of thyroid nodules. MATERIALS AND METHODS: From July 2009 to September 2011, 123 patients with 147 thyroid nodules were included in our study. All patients enrolled had to undergo thyroidectomy because of nodular thyroid disease (goitre or nodules). After preliminary examination with conventional ultrasound (US) and colour Doppler US, the patients were examined with elastosonography, using high-level equipment (Toshiba Aplio XG) and quantitative software (Elasto-Q). Each lesion was characterised using an US score (echogenicity, borders, microcalcifications and colour Doppler pattern), and then by elastosonographic strain ratio. Each patient subsequently underwent thyroidectomy. Histological results were used as the gold standard. RESULTS: Histological examination demonstrated 89 benign and 58 malignant lesions. On average, the strain ratio value was 2.84±2.69 (range, 0.05-14.5; p=0.001). Sensitivity and specificity of the US score were about 56% and 72%, respectively, whereas those of the strain ratio were 93% and 89%, using a cut-off of 2 obtained with receiver operating characteristic (ROC) curve analysis. Elastosonography was more accurate than US and colour Doppler US in characterising thyroid nodules (p=0.002). CONCLUSIONS: Quantitative elastosonography is a useful diagnostic tool in the evaluation of thyroid lesions, and can be used to limit fine-needle aspiration cytology and improve the selection of patients for thyroidectomy.


Subject(s)
Elasticity Imaging Techniques/methods , Thyroid Nodule/diagnostic imaging , Adolescent , Adult , Aged , Biopsy, Fine-Needle , Female , Humans , Male , Middle Aged , Patient Selection , Prospective Studies , Sensitivity and Specificity , Thyroid Nodule/pathology , Thyroid Nodule/surgery , Thyroidectomy , Ultrasonography, Doppler, Color
SELECTION OF CITATIONS
SEARCH DETAIL