Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biosensors (Basel) ; 11(12)2021 Dec 03.
Article in English | MEDLINE | ID: mdl-34940251

ABSTRACT

Diabetes has become a major health problem in society. Invasive glucometers, although precise, only provide discrete measurements at specific times and are unsuitable for long-term monitoring due to the injuries caused on skin and the prohibitive cost of disposables. Remote, continuous, self-monitoring of blood sugar levels allows for active and better management of diabetics. In this work, we present a radio frequency (RF) sensor based on a stepped impedance resonator for remote blood glucose monitoring. When placed on top of a human hand, this RF interdigital sensor allows detection of variation in blood sugar levels by monitoring the changes in the dielectric constant of the material underneath. The designed stepped impedance resonator operates at 3.528 GHz with a Q factor of 1455. A microfluidic device structure that imitates the blood veins in the human hand was fabricated in PDMS to validate that the sensor can measure changes in glucose concentrations. To test the RF sensor, glucose solutions with concentrations ranging from 0 to 240 mg/dL were injected into the fluidic channels and placed underneath the RF sensor. The shifts in the resonance frequencies of the RF sensor were measured using a network analyzer via its S11 parameters. Based on the change in resonance frequencies, the sensitivity of the biosensor was found to be 264.2 kHz/mg·dL-1 and its LOD was calculated to be 29.89 mg/dL.


Subject(s)
Biosensing Techniques , Blood Glucose , Microfluidics , Blood Glucose Self-Monitoring , Humans , Radio Waves
2.
Biosensors (Basel) ; 11(10)2021 Oct 13.
Article in English | MEDLINE | ID: mdl-34677344

ABSTRACT

Glioblastoma (GBM) is one of the most aggressive solid tumors, particularly due to the presence of cancer stem cells (CSCs). Nowadays, the characterization of this cell type with an efficient, fast and low-cost method remains an issue. Hence, we have developed a microfluidic lab-on-a-chip based on dielectrophoresis (DEP) single cell electro-manipulation to measure the two crossover frequencies: fx01 in the low-frequency range (below 500 kHz) and fx02 in the ultra-high-frequency range (UHF, above 50 MHz). First, in vitro conditions were investigated. An U87-MG cell line was cultured in different conditions in order to induce an undifferentiated phenotype. Then, ex vivo GBM cells from patients' primary cell culture were passed through the developed microfluidic system and characterized in order to reflect clinical conditions. This article demonstrates that the usual exploitation of low-frequency range DEP does not allow the discrimination of the undifferentiated GBM cells from the differentiated one. However, the presented study highlights the use of UHF-DEP as a relevant discriminant parameter. The proposed microfluidic lab-on-a-chip is able to follow the kinetics of U87-MG phenotype transformation in a CSC enrichment medium and the cancer stem cells phenotype acquirement.


Subject(s)
Electrophoresis , Glioblastoma , Lab-On-A-Chip Devices , Cell Differentiation , Humans , Phenotype
3.
Anal Chem ; 93(37): 12664-12671, 2021 09 21.
Article in English | MEDLINE | ID: mdl-34491042

ABSTRACT

Cancer stem cells (CSCs) appear to be an essential target for cancer therapies, in particular, in brain tumors such as Glioblastoma. Nevertheless, their isolation is made difficult by their low content in culture or tumors (<5% of the tumor mass) and is essentially based on the use of fluorescent or magnetic labeling techniques, increasing the risk of differentiation induction. The use of label-free separation methods such as sedimentation field-flow fractionation (SdFFF) is promising, but it becomes necessary to consider a coupling with a detection and characterization method for future identification and purification of CSCs from patient-derived tumors. In this study, we demonstrate for the first time the capability of using an ultrahigh-frequency range dielectrophoresis fluidic biosensor as a detector. This implies an important methodological adaptation of SdFFF cell sorting by the use of a new compatible carrier liquid DEP buffer (DEP-B). After SdFFF sorting, subpopulations derived from U87-MG and LN18 cell lines undergo biological characterization, demonstrating that using DEP-B as a carrier liquid, we sorted by SdFFF subpopulations with specific differentiation characteristics: F1 = differentiated cells/F2 = CSCs. These subpopulations presented high-frequency crossover (HFC) values similar to those measured for standard differentiated (around 110 MHz) and CSC (around 80 MHz) populations. This coupling appeared as a promising solution for the development of an online integration of these two complementary label-free separation/detection technologies.


Subject(s)
Biosensing Techniques , Fractionation, Field Flow , Glioblastoma , Cell Movement , Cell Separation , Humans , Neoplastic Stem Cells
4.
Cancers (Basel) ; 12(1)2020 Jan 17.
Article in English | MEDLINE | ID: mdl-31963405

ABSTRACT

Medulloblastoma (MB) is the most common malignant pediatric brain tumor. Despite the progress of new treatments, the risk of recurrence, morbidity, and death remains significant and the long-term adverse effects in survivors are substantial. The fraction of cancer stem-like cells (CSCs) because of their self-renewal ability and multi-lineage differentiation potential is critical for tumor initiation, growth, and resistance to therapies. For the development of new CSC-targeted therapies, further in-depth studies are needed using enriched and stable MB-CSCs populations. This work, aimed at identifying the amount of CSCs in three available human cell lines (DAOY, D341, and D283), describes different approaches based on the expression of stemness markers. First, we explored potential differences in gene and protein expression patterns of specific stem cell markers. Then, in order to identify and discriminate undifferentiated from differentiated cells, MB cells were characterized using a physical characterization method based on a high-frequency dielectrophoresis approach. Finally, we compared their tumorigenic potential in vivo, through engrafting in nude mice. Concordantly, our findings identified the D283 human cell line as an ideal model of CSCs, providing important evidence on the use of a commercial human MB cell line for the development of new strategic CSC-targeting therapies.

5.
Biosens Bioelectron ; 49: 305-11, 2013 Nov 15.
Article in English | MEDLINE | ID: mdl-23792623

ABSTRACT

Circulating blood monocytes belong to the first line of defense against pathogens and inflammation. Monocytes can be divided into three populations defined by the expression of the cell surface molecules, CD 14 and CD 16. The CD 14(++) CD 16(-) cells, called "classical" monocytes, represent 85% to 95% of the total monocytes in a healthy person whereas CD 14(-) CD 16(+), called "proinflammatory" monocytes, are found in greater numbers in the blood of patients with acute inflammation and infectious diseases. This increase in the concentration of proinflammatory monocytes can be a good indicator of an infectious state. This study presents an immunosensor based on impedance detection for specific cell trapping of classical and proinflammatory monocytes. The grafting of specific antibodies (CD 14 or CD 16) was based on the use of mixed SAM associated with protein G. Each step of the functionalization was characterized by electrochemical methods, quartz crystal microbalance and atomic force microscopy. Faradaic electrochemical impedance spectroscopy and voltametric analysis confirmed the success of the modification process with a surface coverage reaching 92% for the antibody layer. The increase in the deposited mass at each step of the modification process confirmed this results revealing that one protein G in two was bound to an antibody. The cell trapping capacity, evaluated by the variation in the film resistance using non-faradaic impedance spectroscopy revealed that the cell trapping is selective, depending on the specific antibody grafted and quantitative with the range of detection being 1000 to 30,000 infected cells. This range of detection is consistent with the application targeted.


Subject(s)
CD18 Antigens/analysis , Dielectric Spectroscopy/methods , Monocytes/immunology , Receptors, IgG/analysis , Biosensing Techniques/methods , Cells, Cultured , Humans , Immunoassay/methods , Inflammation/blood , Inflammation/diagnosis , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...