Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
Add more filters










Publication year range
1.
ACS Omega ; 8(33): 30442-30449, 2023 Aug 22.
Article in English | MEDLINE | ID: mdl-37636904

ABSTRACT

The high thermal conductivity of polycrystalline diamond makes it ideally suited for thermal management solutions for gallium nitride (GaN) devices, with a diamond layer grown on an aluminum nitride (AlN) interlayer atop the GaN stack. However, this application is limited by the thermal barrier at the interface between diamond and substrate, which has been associated with the transition region formed in the initial phases of growth. In this work, in situ spectroscopic ellipsometry (SE) is employed to monitor early-stage microwave plasma-enhanced chemical vapor deposition diamond growth on AlN. An optical model was developed from ex situ spectra and applied to spectra taken in situ during growth. Coalescence of separate islands into a single film was marked by a reduction in bulk void fraction prior to a spike in sp2 fraction due to grain boundary formation. Parameters determined by the SE model were corroborated using Raman spectroscopy and atomic force microscopy.

2.
Small ; 19(48): e2303976, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37530208

ABSTRACT

Micro-hotplate structures are increasingly being investigated for use in a host of applications ranging from broadband infra-red sources within absorption-based gas sensors to in situ heater stages for ultra-high-resolution imaging. With devices usually fabricated from a conductive electrode placed on top of a freestanding radiator element, coefficient of thermal expansion (CTE) mismatches between layers and electro-migration within the heating element typically lead to failure upon exceeding temperatures of 1600 K. In an attempt to mitigate such issues, a series of hotplates of varying geometry have been fabricated from a single layer of mechanically robust, high thermal conductivity, and low CTE boron-doped polycrystalline diamond. Upon testing under high vacuum conditions and characterization of the emission spectra, the resulting devices are shown to exhibit a grey-body like emission response and reach temperatures vastly in excess of conventional geometries of up to 2731 K at applied powers of ⩽100 mW. Characterization of the thermalization time meanwhile demonstrates rapid millisecond response times, while Raman spectroscopy reveals the performance of the devices is dictated by cumulative graphitization at elevated temperatures. As such, both diamond and sp2 carbon are shown to be promising materials for the fabrication of next-generation micro-hotplates.

3.
Nanoscale Adv ; 5(5): 1307-1315, 2023 Feb 28.
Article in English | MEDLINE | ID: mdl-36866268

ABSTRACT

We report on a novel method for porous diamond fabrication, which is based on the synthesis of diamond-germanium composite films followed by etching of the Ge component. The composites were grown by microwave plasma assisted CVD in CH4-H2-GeH4 mixtures on (100) silicon, and microcrystalline- and single-crystal diamond substrates. The structure and the phase composition of the films before and after etching were analyzed with scanning electron microscopy and Raman spectroscopy. The films revealed a bright emission of GeV color centers due to diamond doping with Ge, as evidenced by photoluminescence spectroscopy. The possible applications of the porous diamond films include thermal management, surfaces with superhydrophobic properties, chromatography, supercapacitors, etc.

4.
Ann Maxillofac Surg ; 13(2): 220-223, 2023.
Article in English | MEDLINE | ID: mdl-38405553

ABSTRACT

Rationale: Apart from the usual presentation of herpes zoster (HZ) infection (HZI), reports of spontaneous teeth exfoliation and osteonecrosis are infrequent and sporadic. Patient Concerns: A 51-year-old male patient presented with spontaneous exfoliation of multiple teeth and subsequent pathological fracture on the right side of the lower jaw after three months of HZI. Diagnosis: Biopsy was taken from the alveolar bone of the oedematous region, which revealed the presence of trabeculae of dead bone with empty lacunae. Intervention: Necrosed part of the alveolar bone was excised under local anaesthesia and antibiotic coverage, which was followed by open reduction and internal fixation of the pathological fracture under general anaesthesia. Outcomes: The patient was followed up for one year without any evidence of recurrences. Take-away Lessons: Presentation of osteonecrosis following HZI is unique but rare and should be diagnosed at the earliest.

5.
ACS Appl Bio Mater ; 2022 Aug 26.
Article in English | MEDLINE | ID: mdl-36027582

ABSTRACT

This work efficiently detects uric acid (UA) in a human blood sample using cobalt nanoparticle-immobilized mixed-valent molybdenum sulfide on the copper substrate in a point-of-care (PoC) device. The sensor electrode was fabricated by micromachining of Cu clad boards employing an engraver to generate a three-electrode system consisting of working electrode (WE), reference electrode (RE), and counter electrode (CE). The WE was subjected to physical vapor deposition of mixed-valent MoSx layers by a reaction between Mo(CO)6 and H2S at ∼200 °C using a simple setup following which CoNPs were electrochemically deposited. The RE and CE were covered with Ag/AgCl and Ag paste, respectively. A plasma separation membrane acted as the medium of UA/blood serum delivery to the electrodes. The material and electrochemical characterization confirmed that CoNPs over MoSx provided an enlarged electroactive surface for the direct electron transfer to achieve an enhanced electrocatalytic response. The binary combination of CoNPs and MoSx layers over the Cu electrode reduced the charge-transfer resistance by two times, enhanced the surface adsorption by more than two times, and yielded a high diffusion coefficient of 3.46 × 10-3 cm2/s. These interfacial effects facilitated the UA oxidation, leading to unprecedented mA range current density for UA sensing for the PoC device. The electrochemical detection tests in the PoC device revealed a sensitivity of 64.7 µA/µM cm-2, which is ∼50 times higher compared to the latest reported value (1.23 µA/µM cm-2), a high limit of detection of 5 nM, and shelf life of 6 months, confirming the synergistic effect-mediated high sensitivity under PoC settings. Interference tests confirmed no intervention of similar analytes. Tests on blood samples demonstrated a recovery percentage close to 100% in human serum UA, signifying the suitability of the nanocomposite-based sensor and the PoC device for clinical sensing applications.

6.
IEEE Trans Biomed Eng ; 69(2): 945-954, 2022 02.
Article in English | MEDLINE | ID: mdl-34495824

ABSTRACT

Growing impact of poststroke upper extremity (UE) functional limitations entails newer dimensions in assessment methodologies. This has compelled researchers to think way beyond traditional stroke assessment scales during the out-patient rehabilitation phase. In concurrence with this, sensor-driven quantitative evaluation of poststroke UE functional limitations has become a fertile field of research. Here, we have emphasized an instrumented wearable for systematic monitoring of stroke patients with right-hemiparesis for evaluating their grasp abilities deploying intelligent algorithms. An instrumented glove housing 6 flex sensors, 3 force sensors, and a motion processing unit was developed to administer 19 activities of Action Research Arm Test (ARAT) while experimenting on 20 voluntarily participating subjects. After necessary signal conditioning, meaningful features were extracted, and subsequently the most appropriate ones were selected using the ReliefF algorithm. An optimally tuned support vector classifier was employed to classify patients with different degrees of disability and an accuracy of 92% was achieved supported by a high area under the receiver operating characteristic score. Furthermore, selected features could provide additional information that revealed the causes of grasp limitations. This would assist physicians in planning more effective poststroke rehabilitation strategies. Results of the one-way ANOVA test conducted on actual and predicted ARAT scores of the subjects indicated remarkable prospects of the proposed glove-based method in poststroke grasp ability assessment and rehabilitation.


Subject(s)
Stroke Rehabilitation , Algorithms , Hand Strength , Health Services Research , Humans , Recovery of Function , Stroke Rehabilitation/methods
7.
Opt Lett ; 46(23): 5826-5829, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-34851900

ABSTRACT

We report the experimental evidence of the Imbert-Fedorov (IF) shift in monolayer MoS2 for a fundamental Gaussian beam. Using Jones vector formalism, we have shown a novel, to the best of our knowledge, pathway to apply the quantum weak measurement technique for easy and accurate determination of the IF shift. We have revealed the dependence of IF shift over a large range of angles of incidence along with the mode of polarization of the incident light. Our experimental findings via the weak value amplification scheme are in good agreement with the theoretical analysis. The present method is a general one and can also be implemented for other materials to observe such tiny transverse shifts.

8.
Materials (Basel) ; 14(23)2021 Dec 06.
Article in English | MEDLINE | ID: mdl-34885619

ABSTRACT

Zinc (Zn) coating is being used to protect steel structures from corrosion. There are different processes to deposit the coating onto a steel substrate. Therefore, in the present study, a 100 µm thick Zn coating was deposited by arc and plasma arc thermal spray coating processes, and the corrosion resistance performance was evaluated in artificial seawater. Scanning electron microscopy (SEM) results showed that the arc thermal spray coating exhibited splats and inflight particles, whereas plasma arc spraying showed a uniform and dense morphology. When the exposure periods were extended up to 23 d, the corrosion resistance of the arc as well as the plasma arc thermal spray coating increased considerably. This is attributed to the blocking characteristics of the defects by the stable hydrozincite (Zn5(OH)6(CO3)2).

9.
Materials (Basel) ; 14(19)2021 Sep 30.
Article in English | MEDLINE | ID: mdl-34640090

ABSTRACT

In the present study, 0.115 M L-arginine (LA) has been used as an eco-friendly inhibitor in simulated concrete pore solutions (SP-0) in order to form passive films on a steel rebar-solution interface until 144 h. Hence, 0.51 (SP-1) and 0.85 M NaCl (SP-2) were added in LA containing SP-0 solution to breakdown the passive film and to initiate corrosion reactions. The electrochemical results show that the charge transfer resistance (Rct) of steel rebar exposed to SP-1 and SP-2 solutions increased with respect to immersion periods. The sample exposed to the SP-2 solution initiated the corrosion reaction at the steel rebar-solution interface after 24 h of NaCl addition and formed pits; on the other hand, the sample without NaCl added, i.e., SP-0, showed agglomeration and dense morphology of corrosion products.

10.
Bioelectrochemistry ; 142: 107893, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34343778

ABSTRACT

Herein we report a novel electrochemical sensing chip and a point-of-care device (PoC) for enzyme-free electrochemical detection of urea in human blood. The electrochemical sensing chip was developed by 3-D printing of conductive Ag ink and subsequent electrodeposition of AuNP-rGO nanocomposite. Material characterization of the sensing chip was conducted to find a plausible mechanism for the electrochemical reaction with urea. Subsequently, the response with varying concentrations of urea in solution and human blood samples was tested. High peak response current (~5 times than that of the highest reported value), low impedance, rapid sensor fabrication procedure, high selectivity towards urea, excellent linear response (R2 = 0.99), high sensitivity of 183 µA mM-1 cm-2, the fast response indicated by high diffusion coefficient, the limit of detection of 0.1 µM, tested shelf life of more than 6 months and recovery rate of >99% ensured the application of the developed sensor chip towards PoC urea detection test kit. A PoC device housing an electronic circuitry following the principles of linear sweep voltammetry and compatible with a sensing chip was developed. A maximum percentage error of 4.86% and maximum RSD of 3.63% confirmed the use of the PoC device for rapid urea measurements in human blood.


Subject(s)
Electrochemical Techniques/methods , Graphite/chemistry , Nanocomposites/chemistry , Urea/blood , Humans
11.
ACS Appl Mater Interfaces ; 13(36): 43676-43695, 2021 Sep 15.
Article in English | MEDLINE | ID: mdl-34463095

ABSTRACT

The present study has been focused on the environment-friendly corrosion inhibitor. Conifer cone (Pinus resinosa) has been used as a novel corrosion inhibitor to mitigate the corrosion of steel rebars in simulated concrete pore solutions (SCPS) in the presence and absence of chloride ions. The corrosion inhibitor is extracted by simple chemical methods. The functional groups present in the extracted conifer cone (ECC) powder are characterized as well as the surface morphology of ECC has been examined. The corrosion inhibition performance has been evaluated by the electrochemical and weight loss methods. The experimental results indicate that ECC possesses a corrosion inhibition efficiency of 81.2% at a dosage of 1000 mg·L-1, after 720 h of immersion in chloride-contaminated SCPS. Adsorption isotherm and their standard Gibbs free energy (ΔGads0) values are calculated by Langmuir, Freundlich, and Temkin isotherm methods, and the results indicate that the ECC is initially adsorbed on the steel rebar surface by physisorption and then it turns to chemisorption. The steel rebar surfaces have been characterized after exposure to the ECC containing SCPS, and the results indicate that the ECC containing cationic adsorbate molecules, which interact with steel rebar, leads to retardation of metal dissolution in corrosive chloride medium.

12.
Sci Rep ; 11(1): 15012, 2021 Jul 22.
Article in English | MEDLINE | ID: mdl-34294858

ABSTRACT

Lauric acid (LA) has been recommended as economic, eco-friendly, and commercially viable materials to be used as phase change materials (PCMs). Nevertheless, there is lack of optimized parameters to produce microencapsulated PCMs with good performance. In this study, different amounts of LA have been chosen as core materials while tetraethyl orthosilicate (TEOS) as the precursor solution to form silicon dioxide (SiO2) shell. The pH of precursor solution was kept at 2.5 for all composition of microencapsulated LA. The synthesized microencapsulated LA/SiO2 has been characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), X-Ray photoelectron spectroscopy (XPS), Scanning electron microscopy (SEM), and Transmission electron microscopy (TEM). The SEM and TEM confirm the microencapsulation of LA with SiO2. Thermogravimetric analysis (TGA) revealed better thermal stability of microencapsulated LA/SiO2 compared to pure LA. PCM with 50% LA i.e. LAPC-6 exhibited the highest encapsulation efficiency (96.50%) and encapsulation ratio (96.15%) through Differential scanning calorimetry (DSC) as well as good thermal reliability even after 30th cycle of heating and cooling process.

13.
ACS Biomater Sci Eng ; 7(7): 3446-3458, 2021 07 12.
Article in English | MEDLINE | ID: mdl-34142794

ABSTRACT

Metal nanoparticles have been helpful in creatinine sensing technology under point-of-care (POC) settings because of their excellent electrocatalyst properties. However, the behavior of monometallic nanoparticles as electrochemical creatinine sensors showed limitations concerning the current density in the mA/cm2 range and wide detection window, which are essential parameters for the development of a sensor for POC applications. Herein, we report a new sensor, a reduced graphene oxide stabilized binary copper-iron oxide-based nanocomposite on a 3D printed Ag-electrode (Fe-Cu-rGO@Ag) for detecting a wide range of blood creatinine (0.01 to 1000 µM; detection limit 10 nM) in an electrochemical chip with a current density ranging between 0.185 and 1.371 mA/cm2 and sensitivity limit of 1.1 µA µM-1 cm-2 at physiological pH. Interference studies confirmed that the sensor exhibited no interference from analytes like uric acid, urea, dopamine, and glutathione. The sensor response was also evaluated to detect creatinine in human blood samples with high accuracy in less than a minute. The sensing mechanism suggested that the synergistic effects of Cu and iron oxide nanoparticles played an essential role in the efficient sensing where Fe atoms act as active sites for creatinine oxidation through the secondary amine nitrogen, and Cu nanoparticles acted as an excellent electron-transfer mediator through rGO. The rapid sensor fabrication procedure, mA/cm2 peak current density, a wide range of detection limits, low contact resistance including high selectivity, excellent linear response (R2 = 0.991), and reusability ensured the application of advanced electrochemical sensor toward the POC creatinine detection.


Subject(s)
Metal Nanoparticles , Nanocomposites , Copper , Creatinine , Electrochemical Techniques , Electrodes , Ferric Compounds , Graphite , Humans , Point-of-Care Systems , Printing, Three-Dimensional , Silver
14.
ACS Appl Nano Mater ; 4(3): 3252-3261, 2021 Mar 26.
Article in English | MEDLINE | ID: mdl-33817563

ABSTRACT

Electropositive membranes demonstrating high flux at low pressure differentials show great promise as universal separation platforms for viruses and other charged entities when centralized systems of water and power are scarce. However, the fabrication of a suitably stable membrane with optimal electrostatic characteristics remains a challenge. Here, hydrogenated detonation nanodiamond was loaded onto a quartz microfiber support membrane and coupled to the membrane surface under a high vacuum annealing process. The fabricated membranes display a zeta potential of +45 mV at pH 7 and an isoelectric point around pH 11. We show that the nanodiamond coating is robust to prolonged periods of pressurized water flow by performing extensive zeta potential measurements over time, and water filtration tests demonstrated excellent membrane retention for the electronegative dye molecule acid black 2, and at least a 6.2 log10 reduction in MS2 bacteriophage from feed waters (>99.9999%).

15.
Analyst ; 146(6): 1839-1843, 2021 Mar 21.
Article in English | MEDLINE | ID: mdl-33592079

ABSTRACT

We present a new method for the rapid and cost-effective fabrication of solid electrolyte-based printed potentiometric oxygen sensors working at ambient temperature using Cu-dithiolated diethylene triamine pentaacetic acid complex molecules (Cu-DTDTPA) adsorbed on Grade-1 laboratory filter paper and subsequent 3-D printing of interdigitated electrodes employing silver/silver chloride ink. The decrease in conductivity with time and frequency-dependent impedance response confirms the filter paper adsorbed Cu-DTDTPA as a solid electrolyte. A plausible structure of the Cu-DTDTPA solid electrolyte and its mechanism of reaction with oxygen are presented. A maximum sensitivity of 0.052 mV per %O2, the maximum response time of 1.15 s per %O2, a wide measurement output ranging from 14.55 mV to 17.25 mV for 20%-90% of O2 concentration, a maximum standard deviation of 0.12 mV in output voltage, almost similar trends of the response on temperature, humidity variations and ageing and high selectivity establish the sensor for use in medical ventilator applications, specifically in the COVID19 pandemic.

16.
RSC Adv ; 11(17): 10159-10182, 2021 Mar 05.
Article in English | MEDLINE | ID: mdl-35423515

ABSTRACT

Diamond thin films are known to have properties similar to bulk diamond and have applications in both industry and fundamental studies in academia. The high surface energy of diamond makes it extremely difficult to grow diamond films on foreign substrates. Hence, to grow diamond films on non-diamond substrates, a nucleation step is needed. In this review various techniques used for diamond nucleation/seeding will be discussed. At present electrostatic seeding by diamond nanoparticles is the most commonly used seeding technique for nanocrystalline growth. In this technique the substrate is dipped in a nanodiamond solution to form a mono layer of diamond seeds. These seeds when exposed to appropriate conditions grow to form diamond layers. This technique is suitable for most substrates. For heteroepitaxial growth, bias enhanced nucleation is the primary technique. In this technique the substrate is biased to form diamond nuclei in the initial stages of growth. This technique can be used for any conducting flat surface. For growth on ceramics, polishing by diamond grit or electrostatic seeding can be used. Polishing the ceramics with diamond powder leaves small diamond particles embedded in the substrate. These small particles then act as seeds for subsequent diamond growth. Apart from these techniques, chemical nucleation, interlayer driven nucleation and mixed techniques have been discussed. The advantages and disadvantages of individual techniques have also been discussed.

17.
Molecules ; 25(22)2020 Nov 17.
Article in English | MEDLINE | ID: mdl-33213017

ABSTRACT

Graphene is one of the most favorite materials for materials science research owing to its distinctive chemical and physical properties, such as superior conductivity, extremely larger specific surface area, and good mechanical/chemical stability with the flexible monolayer structure. Graphene is considered as a supreme matrix and electron arbitrator of semiconductor nanoparticles for environmental pollution remediation. The present review looks at the recent progress on the graphene-based metal oxide and ternary composites for photocatalysis application, especially for the application of the environmental remediation. The challenges and perspectives of emerging graphene-based metal oxide nanocomposites for photocatalysis are also discussed.


Subject(s)
Graphite/chemistry , Light , Nanocomposites/chemistry , Semiconductors , Water Pollutants, Chemical/isolation & purification , Catalysis/radiation effects
18.
Nanoscale ; 12(42): 21821-21831, 2020 Nov 05.
Article in English | MEDLINE | ID: mdl-33103692

ABSTRACT

The fluorescent nitrogen-vacancy (NV) defect in diamond has remarkable photophysical properties, including high photostability which allows stable fluorescence emission for hours; as a result, there has been much interest in using nanodiamonds (NDs) for applications in quantum optics and biological imaging. Such applications have been limited by the heterogeneity of NDs and our limited understanding of NV photophysics in NDs, which is partially due to the lack of sensitive and high-throughput methods for photophysical analysis of NDs. Here, we report a systematic analysis of NDs using two-color wide-field epifluorescence imaging coupled to high-throughput single-particle detection of single NVs in NDs with sizes down to 5-10 nm. By using fluorescence intensity ratios, we observe directly the charge conversion of single NV center (NV- or NV0) and measure the lifetimes of different NV charge states in NDs. We also show that we can use changes in pH to control the main NV charge states in a direct and reversible fashion, a discovery that paves the way for performing pH nanosensing with a non-photobleachable probe.

19.
Sci Rep ; 10(1): 15023, 2020 09 14.
Article in English | MEDLINE | ID: mdl-32929104

ABSTRACT

Stearic acid (SA) is being used as phase change material (PCM) in energy storage applications. In the present study, the microencapsulation of SA with SiO2 shell was carried out by sol-gel method. Different amounts of SA (5, 10, 15, 20, 30 and 50 g) were taken against 10 ml of tetraethyl orthosilicate (TEOS) for encapsulation. The synthesized microencapsulated PCM (MEPCM) were characterized by Fourier transform infrared spectroscope (FT-IR), X-Ray diffraction (XRD), X-Ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). The characterization results showed that SA was successfully encapsulated by SiO2. Thermogravimetric analysis (TGA) exhibited better thermal stability of the MEPCM than SA. The enthalpy values of MEPCM were found to be unchanged even after 30 heating-cooling cycles by differential scanning calorimetry (DSC). The latent heats of melting and solidification of 50 g SA containing MEPCM were found to be highest i.e. 182.53 J/g and 160.12 J/g, respectively among all microencapsulated samples. The encapsulation efficiency values were calculated using thermal data and the efficiency was found to be highest i.e. 86.68% in the same sample.

20.
Materials (Basel) ; 13(16)2020 Aug 17.
Article in English | MEDLINE | ID: mdl-32824540

ABSTRACT

In the present study, different contents, i.e., 1-3% of 0.5 M ammonium phosphate mono basic (APMB), were used as corrosion inhibitor to reduce the corrosion of steel rebar. Electrochemical impedance spectroscopy (EIS) results showed that up to 24 h of exposure, polarization resistance (Rp) and passive/oxide film resistance (Ro) gradually decreased in simulated concrete pore (SCP) + 3.5 wt.% NaCl solution owing to the reduction in pH of the solution. The steel rebar exposed in 2% inhibitor containing SCP + 3.5 wt.% NaCl solution exhibited 90% inhibition efficiency after 1 h of exposure. X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy confirmed the formation of thermodynamically very stable and sparingly soluble goethite (α-FeOOH), maghemite (γ-Fe2O3), and iron phosphate (FePO4) as passive/oxide film onto the steel rebar surface exposed to 2% inhibitor containing SCP + 3.5 wt.% NaCl solution.

SELECTION OF CITATIONS
SEARCH DETAIL
...