Struct Heart ; 8(3): 100277, 2024 May.
Article in English | MEDLINE | ID: mdl-38799801

ABSTRACT

Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.

2.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

4.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38538170

ABSTRACT

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Heart Valve Prosthesis , Lacerations , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Lacerations/complications , Lacerations/surgery , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Coronary Occlusion/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Prosthesis Design
5.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Article in English | MEDLINE | ID: mdl-38506737

ABSTRACT

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Subject(s)
Aortic Valve Insufficiency , Bioprosthesis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Catheters , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Heart Valves , Registries , Transcatheter Aortic Valve Replacement/adverse effects
6.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38479966

ABSTRACT

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Ischemic Stroke , Stroke , Transcatheter Aortic Valve Replacement , Humans , Ischemic Stroke/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Stroke/diagnostic imaging , Stroke/etiology , Stroke/prevention & control , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
9.
JACC Case Rep ; 29(3): 102191, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38361557

ABSTRACT

An 81-year-old woman presented with acute pulmonary edema. Echocardiography revealed severe functional mitral regurgitation, the mechanism of which was unusual. An atypical bileaflet tethering caused by disharmonic annular remodeling, concomitant aortic dilatation, and reduced aorto-mitral angle without left ventricular dysfunction or dilatation was found. A transcatheter edge-to-edge repair was nonetheless successfully performed.

10.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Article in English | MEDLINE | ID: mdl-38310281

ABSTRACT

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Subject(s)
Coronary Artery Disease , Coronary Restenosis , Diabetes Mellitus , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Sirolimus/adverse effects , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Myocardial Infarction/epidemiology , Myocardial Infarction/etiology , Diabetes Mellitus/diagnosis , Diabetes Mellitus/epidemiology , Diabetes Mellitus/chemically induced , Registries , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology
11.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Article in English | MEDLINE | ID: mdl-38276659

ABSTRACT

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

13.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37138103

ABSTRACT

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Treatment Outcome , Aortic Valve/surgery , Registries , Prosthesis Design
14.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Article in English | MEDLINE | ID: mdl-37957842

ABSTRACT

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Dilatation , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prosthesis Design
17.
Article in English, Spanish | MEDLINE | ID: mdl-38056772

ABSTRACT

INTRODUCTION AND OBJECTIVES: The PEACE study (Performance of a sirolimus-eluting balloon strategy in acute and chronic coronary syndromes) investigated for the first time whether a sirolimus-coated balloon (SCB) (Magic Touch, Concept Medical, India) is associated with different outcomes depending on whether it is used in acute coronary syndromes (ACS) or chronic coronary syndromes (CCS). METHODS: This was a post-hoc analysis from the all-comers EASTBOURNE Registry (NCT03085823). Out of 2083 patients enrolled, an SCB was used to treat 968 (46.5%) ACS and 1115 (53.5%) CCS patients. The primary endpoint was target lesion revascularization at 12 months, while secondary endpoints were angiographic success and major adverse cardiovascular events. RESULTS: Baseline demographics, mean reference vessel diameter and mean lesion length were comparable between ACS and CCS. Predilatation was more commonly performed in ACS (P=.007). SCB was inflated at a standard pressure in both groups with a slight trend toward longer inflation time in ACS. Angiographic success was high in both groups (ACS 97.4% vs CCS 97.7%, P=.820) with limited bailout stenting. Similarly, at 12 months the cumulative incidence of target lesion revascularization (ACS 6.6% vs CCS 5.2%, P=.258) was comparable between ACS and CCS. Conversely, a higher rate of major adverse cardiovascular events in acute presenters was mainly driven by myocardial infarction recurrencies (ACS 10.4% vs CCS 8.3%, P=.009). In-stent restenosis showed a higher proportion of target lesion revascularization and major adverse cardiovascular events than de novo lesions, independently of the type of presentation at the index procedure. CONCLUSIONS: This SCB shows good performance in terms of acute and 1-year outcomes independently of the clinical presentation.

20.
Article in English | MEDLINE | ID: mdl-37931791

ABSTRACT

Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.