Adv Ren Replace Ther ; 9(1): 31-41, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11927905

ABSTRACT

Tricyclic overdose can be a medical emergency, and therapy with intravenous bicarbonate is not always successful in preventing cardiac toxicity or coma. Mortality in patients developing these complications is from 1% to 15%. Extracorporeal detoxification with sorbents has been used in treatment of patients with very high drug levels and declining clinical condition. Ten patients with serious drug overdose caused by tricyclics failed to respond quickly to standard therapy and were in stage 3-4 encephalopathy. Nine of these patients were on respirator support, 5 had hypotension, and 6 had QRS widening. Average level was 1,423 microg/L at presentation. Enteral activated charcoal and intravenous (IV) bicarbonate were initiated in the emergency room. The patients were treated for 3 to 4 hours with the Liver Dialysis Unit, a hemodiabsorption device using a cellulosic plate dialyzer and sorbent suspension as dialysate. Inflow and outflow blood levels indicated that the hemodetoxifier removed modest amounts of the tricyclics, metabolites, and other consumed drugs. The clinical improvement of the patients was dramatic, with patients reaching stage 0 or 1 encephalopathy during the treatment. Ventilator support was removed at the end of treatment for 3 patients who had not already developed pneumonia, and for others was prolonged up to 48 hours because of pneumonia, rather than mental status. Average length of stay in the intensive care unit (ICU) was 4.8 days (range 1 to 7 days). None of the patients died despite their high risk for ventricular arrhythmias, seizures, and death. Clinical improvement may have been attributable to removal of free drug from the blood or to removal of drug metabolites.


Subject(s)
Antidepressive Agents, Tricyclic/poisoning , Hemoperfusion/methods , Sorption Detoxification/methods , Charcoal , Drug Overdose , Humans
2.
Hemodial Int ; 4(1): 22-31, 2000 Jan.
Article in English | MEDLINE | ID: mdl-28455911

ABSTRACT

For chronic central venous dialysis catheters, the standard method for maintaining catheter patency between treatments is to instill (lock) catheters with 5000 - 10 000 units of heparin in each lumen. Sodium citrate (citrate) is an anticoagulant with intrinsic antibacterial activity (at 20% concentration or higher). Citrate has only transient anticoagulant effects if accidentally infused to the patient. Prior studies of citrate as a catheter lock solution have utilized citrate concentrations of 1% in combination with 27 mg/mL gentamicin. We changed clinical protocols for catheter locks using various solutions, including concentrated citrate, in a dialysis unit with 50% of patients having chronic central venous catheters [40 catheters total, mostly Ash Split Cath (Medcomp, Harleysville, PA, U.S.A.) but some Tesio (Medcomp) and Hickman (BARD, Salt Lake City, UT, U.S.A.) catheters]. At 3- to 4-month intervals, the standard catheter lock solution for the unit was varied on the following schedule: heparin; 10% citrate with 3 mg/mL gentamicin; 20% citrate with 3 mg/mL gentamicin; heparin; and 23% citrate. Catheters were not routinely removed during treatment of bacteremia. Incidence of bacteremia in patients with catheters using heparin as catheter lock was 4.32 episodes per 3000 patient-days (equivalent to percent of patients with catheters having bacteremia per month). The incidence of bacteremia decreased to 1.68 using 20% citrate/gentamicin as catheter lock (p < 0.05) and to 0% with 47% citrate (p < 0.05). Incidence of bacteremia increased on return to heparin and decreased again with use of 23% citrate to 1.79 (p < 0.05). Use of urokinase for occluded catheters also significantly decreased with citrate during the time that it was available (p = 0.02). Life table analysis indicated an 83% survival of Ash Split Cath catheters at 1 year, in this unit. Concentrated citrate is an effective catheter lock solution that may provide prolonged central venous catheter use with a diminution in catheter-related infections and occlusion.

SELECTION OF CITATIONS
SEARCH DETAIL
...