Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Radiat Oncol Biol Phys ; 21(3): 683-93, 1991 Aug.
Article in English | MEDLINE | ID: mdl-1907960

ABSTRACT

Stereotactic radiosurgery of intra-cranial lesions is a treatment modality where a well defined target volume receives a high radiation dose in a single treatment. Our technique delivers this dose using a set of non-coplanar arcs and small circular collimators. We use a standard linear accelerator in our treatments, and the adjustable treatment parameters are: isocenter location, gantry arc rotation interval, couch angle, collimator field size, and dose. The treatment planning phase of the treatment determines these parameters such that the target volume is sufficiently irradiated, and dose to surrounding healthy tissue and critical, dose-limiting structures is minimized. The attachment of a BRW localizing frame to the patient's cranium combined with CT imaging (and optionally MRI or angiography) provides the required accuracy for localizing individual structures in the treatment volume. The treatment is fundamentally 3-dimensional and requires a volumetric assessment of the treatment plan. The selection of treatment arcs relies primarily on geometric constraints and the beam's eye view concept to avoid irradiating critical structures. The assessment of a treatment plan involves isodose distributions throughout the volume and integral dose-volume histograms. We present the essential concepts of our treatment planning approach, and illustrate these in three clinical cases.


Subject(s)
Brain Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Stereotaxic Techniques , Adolescent , Adult , Child, Preschool , Female , Humans , Male , Particle Accelerators , Radiotherapy, High-Energy
2.
Int J Radiat Oncol Biol Phys ; 21(3): 737-48, 1991 Aug.
Article in English | MEDLINE | ID: mdl-1869467

ABSTRACT

Methods have recently been developed for using standard linear accelerators to perform stereotactic radiosurgery. The accuracy necessary to perform this procedure requires an intensive quality assurance program to encompass all aspects of dose calibration and mechanical integrity of the treatment unit, the treatment planning process, and treatment delivery. The programs developed at the Joint Center for Radiation Therapy (JCRT) include testing of the linear accelerator and the stereotactic system, cross checking of the treatment planning process, and a quality assurance check list of the treatment delivery procedure. This report outlines in detail the quality assurance program currently in use at the JCRT.


Subject(s)
Particle Accelerators/standards , Quality Assurance, Health Care , Radiotherapy/standards , Stereotaxic Techniques/standards , Humans , Radiotherapy Planning, Computer-Assisted/standards
3.
J Clin Oncol ; 8(4): 576-82, 1990 Apr.
Article in English | MEDLINE | ID: mdl-2179476

ABSTRACT

Between May 1986 and August 1989, we treated 18 patients with 21 recurrent or persistent brain metastases with stereotactic radiosurgery using a modified linear accelerator. To be eligible for radiosurgery, patients had to have a performance status of greater than or equal to 70% and have no evidence of (or stable) systemic disease. All but one patient had received prior radiotherapy, and were treated with stereotactic radiosurgery at the time of recurrence. Polar lesions were treated only if the patient had undergone and failed previous complete surgical resection (10 patients). Single doses of radiation (900 to 2,500 cGy) were delivered to limited volumes (less than 27 cm3) using a modified 6MV linear accelerator. The most common histology of the metastatic lesion was carcinoma of the lung (seven patients), followed by carcinoma of the breast (four patients), and melanoma (four patients). With median follow-up of 9 months (range, 1 to 39), all tumors have been controlled in the radiosurgery field. Two patients failed in the immediate margin of the treated volume and were subsequently treated with surgery and implantation of 125I to control the disease. Radiographic response was dramatic and rapid in the patients with adenocarcinoma, while slight reduction and stabilization occurred in those patients with melanoma, renal cell carcinoma, and sarcoma. The majority of patients improved neurologically following treatment, and were able to be withdrawn from corticosteroid therapy. Complications were limited and transient in nature and no cases of symptomatic radiation necrosis occurred in any patient despite previous exposure to radiotherapy. Stereotactic radiosurgery is an effective and relatively safe treatment for recurrent solitary metastases and is an appealing technique for the initial management of deep-seated lesions as a boost to whole brain radiotherapy.


Subject(s)
Brain Neoplasms/radiotherapy , Neoplasm Recurrence, Local/radiotherapy , Adenocarcinoma/radiotherapy , Adult , Aged , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/secondary , Carcinoma/radiotherapy , Follow-Up Studies , Humans , Incidence , Melanoma/radiotherapy , Middle Aged , Radiation Injuries/epidemiology , Remission Induction , Sarcoma/radiotherapy , Stereotaxic Techniques , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...