Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
2.
Dis Esophagus ; 31(3)2018 Mar 01.
Article in English | MEDLINE | ID: mdl-29228128

ABSTRACT

Infrared endoscopy (IRE) has been shown to be useful in detecting submucosal (SM) invasion in early gastric cancer. Its role in the endoscopic assessment of Barrett's neoplasia has not been reported to date. We aimed in this study to evaluate the role of IRE in the detection and characterization of early neoplastic lesions within Barrett's esophagus (BE). The secondary aim was to explore its usefulness for the assessment of the presence of submucosal invasion in these early neoplastic Barrett's lesions. We included in the study patients with dysplastic BE who were referred to our institution for endoscopic therapy of a previously diagnosed early Barrett's neoplasia. An examination with white light high resolution endoscopy (HRE) and near IRE after intravenous injection of indocyanine green was performed for all patients using an infrared endoscope prototype. Staining on IRE and correlation with final histological staging by endoscopic mucosal resection/surgery or histological diagnosis on mapping biopsies was analyzed. A total of 23 patients were enrolled in our study: 17 of them with 19 visible lesions and 6 patients with flat BE and no lesions. Staining on IRE was noted in 18 cases: 17 (94%) had at least high grade dysplasia (HGD). No stain was noted in 7 cases: final histology was

Subject(s)
Barrett Esophagus/complications , Early Detection of Cancer/methods , Esophageal Neoplasms/diagnosis , Esophagoscopy/methods , Infrared Rays , Aged , Aged, 80 and over , Barrett Esophagus/pathology , Biopsy/methods , Coloring Agents , Endoscopic Mucosal Resection , Esophageal Neoplasms/etiology , Esophagus/pathology , Female , Humans , Hyperplasia , Indocyanine Green , Male , Middle Aged , Pilot Projects , Prospective Studies
5.
Dis Esophagus ; 28(8): 742-9, 2015.
Article in English | MEDLINE | ID: mdl-25209721

ABSTRACT

High-definition endoscopy systems provide superior image resolution. The aim of this study was to assess the utility of high definition compared with standard definition endoscopy system for detecting dysplastic lesions in patients with Barrett's esophagus. A retrospective cohort study of patients with non-dysplastic Barrett's esophagus undergoing routine surveillance was performed. Data were retrieved from the central hospital electronic database. Procedures performed for non-surveillance indications, Barrett's esophagus Prague C0M1 classification with no specialized intestinal metaplasia on histology, patients diagnosed with any dysplasia or cancer on index endoscopy, and procedures using advanced imaging techniques were excluded. Logistic regression models were constructed to estimate adjusted odds ratios and 95% confidence intervals comparing outcomes with standard definition and high-definition systems. The high definition was superior to standard definition system in targeted detection of all dysplastic lesions (odds ratio 3.27, 95% confidence interval 1.27-8.40) as well as overall dysplasia detected on both random and target biopsies (odds ratio 2.36, 95% confidence interval 1.50-3.72). More non-dysplastic lesions were detected with the high-definition system (odds ratio 1.16, 95% confidence interval 1.01-1.33). There was no difference between high definition and standard definition endoscopy in the overall (random and target) high-grade dysplasia or cancers detected (odds ratio 0.93, 95% confidence interval 0.83-1.04). Trainee endoscopists, number of biopsies taken, and male sex were all significantly associated with a higher yield for dysplastic lesions. The use of the high-definition endoscopy system is associated with better targeted detection of any dysplasia during routine Barrett's esophagus surveillance. However, high-definition endoscopy cannot replace random biopsies at present time.


Subject(s)
Barrett Esophagus/pathology , Early Detection of Cancer/methods , Esophageal Neoplasms/diagnosis , Esophagoscopy/methods , Precancerous Conditions/diagnosis , Aged , Case-Control Studies , Esophagus/pathology , Female , Humans , Logistic Models , Male , Mass Screening/methods , Middle Aged , Population Surveillance/methods , Retrospective Studies , Transillumination/methods
6.
Dig Dis Sci ; 58(2): 465-70, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22961240

ABSTRACT

BACKGROUND: Autofluorescence imaging (AFI), which is a "red flag" technique during Barrett's surveillance, is associated with significant false positive results. The aim of this study was to assess the inter-observer agreement (IOA) in identifying AFI-positive lesions and to assess the overall accuracy of AFI. METHODS: Anonymized AFI and high resolution white light (HRE) images were prospectively collected. The AFI images were presented in random order, followed by corresponding AFI + HRE images. Three AFI experts and 3 AFI non-experts scored images after a training presentation. The IOA was calculated using kappa and accuracy was calculated with histology as gold standard. RESULTS: Seventy-four sets of images were prospectively collected from 63 patients (48 males, mean age 69 years). The IOA for number of AF positive lesions was fair when AFI images were presented. This improved to moderate with corresponding AFI and HRE images [experts 0.57 (0.44-0.70), non-experts 0.47 (0.35-0.62)]. The IOA for the site of AF lesion was moderate for experts and fair for non-experts using AF images, which improved to substantial for experts [κ = 0.62 (0.50-0.72)] but remained at fair for non-experts [κ = 0.28 (0.18-0.37)] with AFI + HRE. Among experts, the accuracy of identifying dysplasia was 0.76 (0.7-0.81) using AFI images and 0.85 (0.79-0.89) using AFI + HRE images. The accuracy was 0.69 (0.62-0.74) with AFI images alone and 0.75 (0.70-0.80) using AFI + HRE among non-experts. CONCLUSION: The IOA for AF positive lesions is fair to moderate using AFI images which improved with addition of HRE. The overall accuracy of identifying dysplasia was modest, and was better when AFI and HRE images were combined.


Subject(s)
Barrett Esophagus/diagnosis , Endoscopy, Digestive System/standards , Gastroenterology/standards , Optical Imaging/standards , Precancerous Conditions/diagnosis , Aged , Endoscopy, Digestive System/methods , Endoscopy, Digestive System/statistics & numerical data , Female , Humans , Male , Observer Variation , Optical Imaging/methods , Optical Imaging/statistics & numerical data , Prospective Studies , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
8.
Aliment Pharmacol Ther ; 35(7): 819-27, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22372517

ABSTRACT

BACKGROUND: Diclofenac-potassium (diclofenac--K) 25 mg liquid capsule is absorbed more quickly than the tablet formulation. It offers potential for rapid pain relief, but may alter gastro-duodenal tolerability. AIM: To evaluate the gastro-duodenal tolerance of diclofenac-K 25 mg liquid capsules vs. diclofenac-K 12.5 mg tablets, acetylsalicylic acid (ASA) 500 mg tablets and ibuprofen 200 mg liquid capsules. METHODS: In an endoscopist-blinded, randomised, parallel-group study, volunteers received 15 doses of diclofenac-K 25 mg liquid capsules (n = 36), diclofenac-K 2 × 12.5 mg tablets (n = 36), ibuprofen 2 × 200 mg liquid capsules (n = 24) or ASA 2 × 500 mg tablets (n = 36) over 5 days. The primary outcome was the incidence of erosive gastro-duodenal lesions at Day 6. Secondary outcomes included modified Lanza score and change in gastric mucosal prostaglandin synthesis. RESULTS: The lowest incidence of erosive gastro-duodenal lesions was with diclofenac-K liquid capsules (53%), compared to 61% with diclofenac-K tablets (P = 0.52), 75% with ibuprofen (P = 0.08) and 94% with ASA (P = 0.001). Results were similar for the Lanza scores, although diclofenac-K liquid capsules were significantly superior to ibuprofen liquid capsules (P = 0.04). Diclofenac-K liquid capsules inhibited prostaglandin synthesis by 52% compared to 64% for diclofenac-K tablets (P = 0.10), 50% for ibuprofen (P = 0.85) and 79% for ASA (P = 0.002). With respect to safety, adverse events were most frequent in the ASA group, predominantly gastrointestinal events. CONCLUSIONS: Mucosal injury with diclofenac-K liquid 25 mg liquid capsules was similar to diclofenac-K 25 mg tablets, significantly lower than ASA 1 g tablets and showed some superiority over ibuprofen 400 mg liquid capsules (EudraCT Number 2009-011278-14).


Subject(s)
Analgesics/administration & dosage , Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Aspirin/administration & dosage , Diclofenac/administration & dosage , Ibuprofen/administration & dosage , Adolescent , Adult , Analgesics/adverse effects , Anti-Inflammatory Agents, Non-Steroidal/adverse effects , Aspirin/adverse effects , Capsules , Diclofenac/adverse effects , Drug Tolerance , Duodenum/drug effects , Endoscopy, Gastrointestinal , Female , Gastric Mucosa/drug effects , Humans , Male , Pain Measurement , Tablets , Time Factors , Young Adult
9.
Endoscopy ; 43(6): 499-505, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21360420

ABSTRACT

BACKGROUND AND STUDY AIMS: High definition colonoscopy may improve adenoma detection rates but studies report conflicting results. The aim of this meta-analysis was to compare the diagnostic yield of colonic polyps between high definition colonoscopy and standard video endoscopy (SVE). METHODS: Various electronic databases were searched for articles reporting on high definition colonoscopy. The pooled incremental yield and pooled weighted mean difference of high definition colonoscopy over SVE for polyp detection was determined. RESULTS: Five studies involving 4422 patients provided data on the total number of polyps detected. The incremental yield of high definition colonoscopy for the detection of any polyp was 3.8 % (95 % confidence interval [CI] 1 % - 6.7 %) with a number needed to treat (NNT) of 26. For the detection of adenomatous polyps the incremental yield was 3.5 % (95 %CI 0.9 % - 6.1 %) with an NNT of 28. There were no differences between high definition and SVE in the detection of high risk adenomas, with an incremental yield of -0.1 % (95 %CI -1.7 % to 1.6 %). When grouped according to the overall adenoma detection rate of the studies (> 50 % or < 50 %) the pooled weighted mean difference in small adenoma detection was better with high definition colonoscopy ( P = 0.035). CONCLUSIONS: There were marginal differences between high definition colonoscopy and SVE for the detection of colonic polyps/adenomas. High definition colonoscopy did not improve the detection of high risk adenomas. Due to differences in the adenoma detection rate between the studies and the nonrandomized study design of three of the five studies, these results need to be interpreted with caution. Prospective randomized trials looking at long term outcomes such as rates of interval or missed cancers are needed to clarify the clinical implications.


Subject(s)
Adenomatous Polyps/diagnosis , Colonic Neoplasms/diagnosis , Colonic Polyps/diagnosis , Colonoscopy/methods , Adenomatous Polyps/pathology , Colonic Neoplasms/pathology , Colonoscopes , Humans
10.
Endoscopy ; 43(5): 386-93, 2011 May.
Article in English | MEDLINE | ID: mdl-21437850

ABSTRACT

BACKGROUND AND AIMS: Fully covered self-expanding removable stents (SERS) have been considered a viable alternative to serial bougienage. The primary aim of this meta-analysis was to determine the efficacy of SERS for refractory esophageal strictures. METHODS: Medline, Embase, and PubMed databases were searched using the keywords "esophageal stricture," "esophageal stents," "benign stricture," "dysphagia," "caustic," "peptic stricture," "anastomotic," "radiation," and "dysphagia" for the period from January 1965 to June 2010. Articles were selected for review independently by two authors (T. T. and J. M.) on the basis of predefined inclusion criteria, and the data collected. A meta-analysis using a random effects model was done. RESULTS: Eight studies with a total of 199 patients were included in the final analysis (104-males, average age 56 years, range: 49 - 68 years). Overall, 46.2 % of patients (95 %CI: 38.3 % - 54.1 %) had dysphagia improvement at an average follow up of 74 weeks. There was a significant difference ( P = 0.019) in dysphagia improvement for patients with Polyflex stents (55.3 %; 95 %CI: 44.4 % - 65.9 %) versus nitinol stents (21.8 %; 95 %CI: 13.7 % - 33.7 %). On meta-regression, patient sex ( P = 0.80), patient age ( P = 0.725), corrosive etiology ( P = 0.30), stricture location ( P = 0.273), stricture length ( P = 0.32), time of removal ( P = 0.056), and duration of follow-up (0.35) had no significance influence on the outcome. The migration rate was 26.4 % (95 %CI: 25.3 % - 39.3 %). CONCLUSIONS: Although the efficacy of SERS placement in benign refractory strictures is 46.2 %, it is associated with migration rate of 26.4 %. Nevertheless, the use of these temporary stents, which can be successfully removed in 87 % of patients, is an alluring prospect for treating patients with this difficult condition.


Subject(s)
Esophageal Stenosis/therapy , Stents , Aged , Deglutition Disorders/etiology , Deglutition Disorders/therapy , Esophageal Stenosis/complications , Female , Humans , Male , Middle Aged , Stents/adverse effects
11.
Dig Dis Sci ; 56(8): 2389-95, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21327705

ABSTRACT

BACKGROUND: Endoscopic mucosal resection (EMR) is used for treatment of sessile and flat colonic adenomas. There is limited data comparing polyp recurrence between piecemeal and en-bloc resections. AIM: The purpose of this study was to evaluate the incidence density and predictive factors for polyp recurrence after piecemeal and en-bloc resections. METHODS: Patients undergoing EMR of flat or sessile adenomas≥10 mm were included. Incidence density (ID) and incidence rate ratio (IRR) of polyp recurrence were calculated. Predictive factors for recurrence were assessed by multivariate analysis using logistic regression. RESULTS: A total of 105 patients (males 54, mean age 68) with 121 polyps were included. Sixty-seven polyps (mean size±SD, 23.3±9.2 mm) were resected piecemeal and 54 polyps (mean size 14.7±5.1 mm) were resected en-bloc. There were 12 recurrences in the piecemeal group and two in the en-bloc group. The ID of polyp recurrence in the piecemeal group was 13.1 (95% CI 7.43-23.03) and in the en-bloc group was 2.7 (95% CI 0.67-10.78) per 100 person-years of follow-up. Piecemeal resections were 5.5 (95% CI 1.1-30.48, P=0.045) times and flat polyps were 6.6 (95% CI 1.22-35.53, P=0.028) times more likely to result in recurrence compared to en-bloc resections and sessile polyps, respectively. In the piecemeal group, additional use of argon plasma coagulation (APC) did not affect the recurrence (OR 0.46, P=0.29). CONCLUSIONS: Piecemeal resections and flat polyps are associated with higher recurrence following EMR. Additional use of APC did not affect the recurrence rates after piecemeal resection.


Subject(s)
Adenoma/surgery , Colonic Neoplasms/surgery , Colonic Polyps/surgery , Colonoscopy/methods , Intestinal Mucosa/surgery , Adenoma/pathology , Adenoma/therapy , Aged , Aged, 80 and over , Argon Plasma Coagulation , Colonic Neoplasms/pathology , Colonic Neoplasms/therapy , Colonic Polyps/pathology , Colonic Polyps/therapy , Female , Follow-Up Studies , Humans , Intestinal Mucosa/pathology , Male , Middle Aged , Prospective Studies , Recurrence , Treatment Outcome
12.
Aliment Pharmacol Ther ; 33(3): 304-12, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21128987

ABSTRACT

BACKGROUND: Dysplasia in inflammatory bowel disease (IBD) is often multifocal and flat. Dye spraying is believed to enhance visualisation of subtle mucosal abnormalities. AIM: To perform a meta-analysis of the published studies to compare the diagnostic yield of dysplastic lesions in patients with IBD undergoing surveillance colonoscopy between chromoendoscopy and standard white light endoscopy. METHODS: We searched electronic databases for full journal articles reporting on chromoendoscopy in patients with IBD. Pooled incremental yield of chromoendoscopy over white light endoscopy for dysplasia detection was determined. A fixed effects model was used unless there was significant heterogeneity. Publication bias was assessed using Funnel plots or Egger's test. RESULTS: Six studies involving 1277 patients provided data on a number of dysplastic lesions detected. The difference in yield of dysplasia between chromoendoscopy and white light endoscopy was 7% (95% CI 3.2-11.3) on a per patient analysis with an NNT of 14.3. The difference in proportion of lesions detected by targeted biopsies was 44% (95% CI 28.6-59.1) and flat lesions was 27% (95% CI 11.2-41.9) in favour of chromoendoscopy. CONCLUSIONS: Chromoendoscopy is significantly better than white light endoscopy in detecting dysplasia in patients with colonic IBD. This holds true for all dysplastic lesions, proportion of targeted lesions and proportion of flat lesions detected.


Subject(s)
Colonoscopy/methods , Coloring Agents , Inflammatory Bowel Diseases/pathology , Precancerous Conditions/diagnosis , Biopsy , Humans
14.
Endoscopy ; 42(5): 351-9, 2010 May.
Article in English | MEDLINE | ID: mdl-20200809

ABSTRACT

BACKGROUND AND STUDY AIM: Narrow band imaging (NBI), a novel endoscopic technique that highlights mucosal surface structures and microvasculature is increasingly advocated as a tool to detect and characterize neoplasia and intestinal metaplasia in patients with Barrett's esophagus. We aimed to assess the diagnostic accuracy of NBI with magnification for the diagnosis of high grade dysplasia (HGD) and specialized intestinal metaplasia (SIM) in patients with Barrett's esophagus. METHODS: We performed a meta-analysis of studies which compared NBI-based diagnosis of HGD and SIM with histopathology as the gold standard. RESULTS: Eight studies including 446 patients with 2194 lesions met the inclusion criteria. For diagnosing HGD, the pooled sensitivity, specificity, diagnostic odds ratio (DOR), and area under the curve (AUC) were 0.96 (95 % confidence interval [CI] 0.93-0.99), 0.94 (95 %CI 0.84-1.0), 342.49 (95 %CI 40.49 - 2896.89) and 0.99 (SE 0.01) on a per-lesion analysis with similar results on per-patient analysis.. For the characterization of SIM, the pooled sensitivity, specificity, DOR, and AUC were 0.95 (95 %CI 0.87-1.0), 0.65 (95 %CI 0.52-0.78), 37.53 (95 %CI 6.50-217.62) and 0.88 (SE 0.08) on a per-lesion analysis. CONCLUSION: NBI with magnification is accurate with high diagnostic precision for diagnosis of HGD in Barrett's esophagus on the basis of irregular mucosal pit patterns and/or irregular microvasculature. NBI has high sensitivity but poor specificity for characterizing SIM.


Subject(s)
Barrett Esophagus/pathology , Endoscopy, Gastrointestinal/methods , Image Enhancement/methods , Intestinal Mucosa/pathology , Precancerous Conditions/pathology , Esophagoscopy/methods , Humans , Metaplasia , Observer Variation , Reproducibility of Results , Sensitivity and Specificity
15.
Endoscopy ; 42(1): 34-7, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19856247
SELECTION OF CITATIONS
SEARCH DETAIL
...