Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Obstet Gynecol Clin North Am ; 47(4): 523-544, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33121643

ABSTRACT

Using a novel in vitro model system combining biochemical/histologic with bioengineering approaches has provided significant insights into the physiology of fetal membrane weakening and rupture along with potential mechanistic reasons for lack of efficacy of currently clinically used agents to prevent preterm premature rupture of the membranes (pPROM) and preterm births. Likewise, the model has also facilitated screening of agents with potential for preventing pPROM and preterm birth.


Subject(s)
Extraembryonic Membranes/metabolism , Fetal Membranes, Premature Rupture/metabolism , Fetal Membranes, Premature Rupture/prevention & control , Extraembryonic Membranes/physiopathology , Female , Fetal Membranes, Premature Rupture/physiopathology , Granulocyte-Macrophage Colony-Stimulating Factor/metabolism , Humans , Infant, Newborn , Models, Biological , Pregnancy , Premature Birth/prevention & control , Progesterone/metabolism , Thioctic Acid/metabolism , Thrombin/metabolism , Tumor Necrosis Factor-alpha/metabolism
2.
Article in English | MEDLINE | ID: mdl-32952604

ABSTRACT

We measured speed of sound in bovine articular cartilage as a function of compressive strain. Using techniques we developed, it was possible to apply strain starting from the unstrained, full height of a sample. Our measurements showed that speed of sound was not a monotonic function of strain as reported in earlier investigations. Speed increased with increasing strain over a range of lower strains. It reached a maximum, and then decreased as the strain increased further. These results were corroborated using a model of wave propagation in deformable porous materials. Using this model, we also established conditions under which a maximum in the speed would exist for samples in compression. Our measurements and analysis resolve the conflicting results reported in previous studies.


Subject(s)
Cartilage, Articular , Animals , Cattle , Compressive Strength , Sound , Stress, Mechanical
3.
J Med Biol Eng ; 40(3): 419-427, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32494235

ABSTRACT

PURPOSE: Articular cartilage is known to be mechanically anisotropic. In this paper, the acoustic anisotropy of bovine articular cartilage and the effects of freeze-thaw cycling on acoustic anisotropy were investigated. METHODS: We developed apparatus and methods that use a magnetic L-shaped sample holder, which allowed minimal handling of a tissue, reduced the number of measurements compared to previous studies, and produced highly reproducible results. RESULTS: SOS was greater in the direction perpendicular to the articular surface compared to the direction parallel to the articular surface (N=17, P = 0.00001). Average SOS was 1,758 ± 107 m/s perpendicular to the surface, and 1,617 ± 55 m/s parallel to it. The average percentage difference in SOS between the perpendicular and parallel directions was 8.2% (95% CI: 5.4% to 11%). Freeze-thaw cycling did not have a significant effect on SOS (P>0.4). CONCLUSION: Acoustic measurement of tissue properties is particularly attractive for work in our laboratory since it has the potential for nondestructive characterization of the properties of developing engineered cartilage. Our approach allowed us to observe acoustic anisotropy of articular cartilage rapidly and reproducibly. This property was not significantly affected by freeze-thawing of the tissue samples, making cryopreservation practical for these assays.

4.
Placenta ; 89: 1-7, 2020 01 01.
Article in English | MEDLINE | ID: mdl-31665659

ABSTRACT

INTRODUCTION: We have previously demonstrated two associations of PPROM, (1) inflammation/infection (modeled by tumor necrosis factor (TNF)) and (2) decidual bleeding (modeled by thrombin), both decrease fetal membrane (FM) rupture strength in-vitro. Furthermore, Granulocyte-Macrophage-Colony-Stimulating-Factor (GM-CSF) induced by both TNF and thrombin is a critical intermediate, necessary and sufficient for weakening by either agent. The amnion is the strength component of FM and must weaken for FM to rupture. It is unclear whether GM-CSF weakens amnion (AM) directly, or initially targets choriodecidua (CD) which secondarily releases agents to act on amnion. METHODS: Full thickness FM fragments were treated with/without GM-CSF. Some were preincubated with alpha-lipoic acid (LA), a known inhibitor of FM weakening. The FM fragments were then strength-tested. Separately, FM fragments were initially separated to AM and CD. AM fragments were cultured with Medium ± GM-CSF and then strength-tested. In other experiments, CD fragments were cultured with Medium, GM-CSF, LA, or LA + GM-CSF. Conditioned medium from each group was then incubated with AM. AM was then strength-tested. Matrix Metalloproteinases (MMPs) and Tissue Inhibitors of Matrix Metalloproteinases (TIMPs) were analyzed by Mutiplex Elisa. RESULTS: GM-CSF weakened intact FM which was blocked by LA. GM-CSF did not weaken isolated AM. However, GM-CSF conditioned CD media weakened AM and this weakening was inhibited by LA. GM-CSF treatment of CD increased MMPs 2, 9, and 10, and decreased TIMPs 1-3. LA reversed these effects. CONCLUSIONS: GM-CSF does not weaken amnion directly; GM-CSF acts on CD to increase proteases and decrease anti-proteases which secondarily weaken the amnion.


Subject(s)
Amnion/drug effects , Chorion/drug effects , Fetal Membranes, Premature Rupture/metabolism , Granulocyte-Macrophage Colony-Stimulating Factor/pharmacology , Matrix Metalloproteinases/metabolism , Tissue Inhibitor of Metalloproteinases/metabolism , Amnion/metabolism , Chorion/metabolism , Culture Media, Conditioned , Female , Humans , Pregnancy , Thioctic Acid/pharmacology
5.
Tissue Eng Part C Methods ; 24(8): 443-456, 2018 08.
Article in English | MEDLINE | ID: mdl-29999475

ABSTRACT

Previous investigations have shown that tissue-engineered articular cartilage can be damaged under a combination of compression and sliding shear. In these cases, damage was identified in histological sections after a test was completed. This approach is limited, in that it does not identify when damage occurred. This especially limits the utility of an assay for evaluating damage when comparing modifications to a tissue-engineering protocol. In this investigation, the feasibility of using ultrasound (US) to detect damage as it occurs was investigated. US signals were acquired before, during, and after sliding shear, as were stereomicroscope images of the cartilage surface. Histology was used as the standard for showing if a sample was damaged. We showed that US reflections from the surface of the cartilage were attenuated due to roughening following sliding shear. Furthermore, it was shown that by scanning the transducer across a sample, surface roughness and erosion following sliding shear could be identified. Internal delamination could be identified by the appearance of new echoes between those from the front and back of the sample. Thus, it is feasible to detect damage in engineered cartilage using US.


Subject(s)
Cartilage, Articular/diagnostic imaging , Cartilage, Articular/pathology , Stress, Mechanical , Tissue Engineering/methods , Ultrasonography , Animals , Cattle , Compressive Strength , Rabbits , Surface Properties , Weight-Bearing
6.
Placenta ; 68: 9-14, 2018 08.
Article in English | MEDLINE | ID: mdl-30055672

ABSTRACT

INTRODUCTION: We established an in-vitro model for the study of human fetal membrane (FM) weakening leading to pPROM. In this model, granulocyte-macrophage colony-stimulating factor (GM-CSF) is a critical intermediate for both tumor necrosis factor-α (TNF; modeling infection/inflammation) and thrombin (modeling decidual bleeding/abruption)-induced weakening. Thus, inhibitors of FM weakening can be categorized as targeting GM-CSF production, GM-CSF downstream action, or both. Most progestogens inhibit both, except 17-α hydroxyprogesterone caproate which inhibits FM weakening at only one point, GM-CSF production. α-lipoic acid (LA), an over-the-counter dietary supplement, has also been previously shown to inhibit TNF and thrombin induced FM weakening. OBJECTIVE: To determine the point of action of LA inhibition of FM weakening. METHODS: FM fragments were mounted in Transwell inserts and preincubated with/without LA/24 h, then with/without addition of TNF, thrombin or GM-CSF. After 48 h, medium was assayed for GM-CSF, and FM fragments were rupture-strength tested. RESULTS: TNF and thrombin both weakened FM and increased GM-CSF levels. GM-CSF also weakened FM. LA inhibited both TNF and thrombin induced FM weakening and concomitantly inhibited the increase in GM-CSF in a concentration-dependent manner. In addition, LA inhibited GM-CSF induced FM weakening in a concentration dependent manner. CONCLUSIONS: LA blocks TNF and thrombin induced FM weakening at two points, inhibiting both GM-CSF production and downstream action. Thus, we speculate that LA may be a potential standalone therapeutic agent, or supplement to current therapy for prevention of pPROM related spontaneous preterm birth, if preclinical studies to examine feasibility and safety during pregnancy are successfully accomplished.


Subject(s)
Extraembryonic Membranes/drug effects , Granulocyte-Macrophage Colony-Stimulating Factor/pharmacology , Inflammation/metabolism , Thioctic Acid/pharmacology , Fetal Membranes, Premature Rupture/metabolism , Humans , In Vitro Techniques , Thrombin/pharmacology , Tumor Necrosis Factor-alpha/pharmacology
7.
Tissue Eng Part A ; 24(5-6): 369-381, 2018 03.
Article in English | MEDLINE | ID: mdl-28548569

ABSTRACT

Low collagen accumulation in the extracellular matrix is a pressing problem in cartilage tissue engineering, leading to a low collagen-to-glycosaminoglycan (GAG) ratio and poor mechanical properties in neocartilage. Soluble factors have been shown to increase collagen content, but may result in a more pronounced increase in GAG content. Thyroid hormones have been reported to stimulate collagen and GAG production, but reported outcomes, including which specific collagen types are affected, are variable throughout the literature. Here we investigated the ability of thyroxine (T4) to preferentially stimulate collagen production, as compared with GAG, in articular chondrocyte-derived scaffold-free engineered cartilage. Dose response curves for T4 in pellet cultures showed that 25 ng/mL T4 increased the total collagen content without increasing the GAG content, resulting in a statistically significant increase in the collagen-to-GAG ratio, a fold change of 2.3 ± 1.2, p < 0.05. In contrast, another growth factor, TGFß1, increased the GAG content in excess of threefold more than the increase in collagen. In large scaffold-free neocartilage, T4 also increased the total collagen/DNA at 1 month and at 2 months (fold increases of 2.1 ± 0.8, p < 0.01 and 2.1 ± 0.4, p < 0.001, respectively). Increases in GAG content were not statistically significant. The effect on collagen was largely specific to collagen type II, which showed a 2.8 ± 1.6-fold increase of COL2A1 mRNA expression (p < 0.01). Western blots confirmed a statistically significant increase in type II collagen protein at 1 month (fold increase of 2.2 ± 1.8); at 2 months, the fold increase of 3.7 ± 3.3 approached significance (p = 0.059). Collagen type X protein was less than the 0.1 µg limit of detection. T4 did not affect COL10A1 and COL1A2 gene expression in a statistically significant manner. Biglycan mRNA expression increased 2.6 ± 1.6-fold, p < 0.05. Results of this study show that an optimized dosage of T4 is able to increase collagen type II content, and do so preferential to GAG. Moreover, the upregulation of COL2A1 gene expression and type II collagen protein accumulation, without a concomitant increase in collagens type I or type X, signifies a direct enhancement of chondrogenesis of hyaline articular cartilage without the induction of terminal differentiation.


Subject(s)
Cartilage, Articular/metabolism , Chondrocytes/metabolism , Collagen Type II/biosynthesis , Gene Expression Regulation/drug effects , Thyroxine/pharmacology , Tissue Engineering , Animals , Cartilage, Articular/cytology , Chondrocytes/cytology , Dose-Response Relationship, Drug , Male , Rabbits
8.
Am J Obstet Gynecol ; 217(6): 695.e1-695.e14, 2017 12.
Article in English | MEDLINE | ID: mdl-29031893

ABSTRACT

BACKGROUND: The progestogen 17-α hydroxyprogesterone caproate (17-OHPC) is 1 of only 2 agents recommended for clinical use in the prevention of spontaneous preterm delivery, and studies of its efficacy have been conflicting. We have developed an in-vitro model to study the fetal membrane weakening process that leads to rupture in preterm premature rupture of the fetal membranes (pPROM). Inflammation/infection associated with tumor necrosis factor-α (TNF-α) induction and decidual bleeding/abruption associated thrombin release are leading causes of preterm premature rupture of the fetal membranes. Both agents (TNF-α and thrombin) cause fetal membrane weakening in the model system. Furthermore, granulocyte-macrophage colony-stimulating factor (GM-CSF) is a critical intermediate for both TNF-α and thrombin-induced fetal membrane weakening. In a previous report, we demonstrated that 3 progestogens, progesterone, 17-alpha hydroxyprogesterone (17-OHP), and medroxyprogesterone acetate (MPA), each inhibit both TNF-α- and thrombin-induced fetal membrane weakening at 2 distinct points of the fetal membrane weakening pathway. Each block both the production of and the downstream action of the critical intermediate granulocyte-macrophage colony-stimulating factor. OBJECTIVE: The objective of the study was to characterize the inhibitory effects of 17-OHPC on TNF-α- and thrombin-induced fetal membrane weakening in vitro. STUDY DESIGN: Full-thickness human fetal membrane fragments from uncomplicated term repeat cesarean deliveries were mounted in 2.5 cm Transwell inserts and cultured with/without 17-alpha hydroxyprogesterone caproate (10-9 to 10-7 M). After 24 hours, medium (supernatant) was removed and replaced with/without the addition of tumor necrosis factor-alpha (20 ng/mL) or thrombin (10 U/mL) or granulocyte-macrophage colony-stimulating factor (200 ng/mL). After 48 hours of culture, medium from the maternal side compartment of the model was assayed for granulocyte-macrophage colony-stimulating factor and the fetal membrane fragments were rupture strength tested. RESULTS: Tumor necrosis factor-alpha and thrombin both weakened fetal membranes (43% and 62%, respectively) and increased granulocyte-macrophage colony-stimulating factor levels (3.7- and 5.9-fold, respectively). Pretreatment with 17-alpha hydroxyprogesterone caproate inhibited both tumor necrosis factor-alpha- and thrombin-induced fetal membrane weakening and concomitantly inhibited the induced increase in granulocyte-macrophage colony-stimulating factor in a concentration-dependent manner. However, contrary to our prior reports regarding progesterone and other progestogens, 17-alpha hydroxyprogesterone caproate did not also inhibit granulocyte-macrophage colony-stimulating factor-induced fetal membrane weakening. CONCLUSION: 17-Alpha hydroxyprogesterone caproate blocks tumor necrosis factor-alpha- and thrombin-induced fetal membrane weakening by inhibiting the production of granulocyte-macrophage colony-stimulating factor. However, 17-alpha hydroxyprogesterone caproate did not also inhibit granulocyte-macrophage colony-stimulating factor-induced weakening. We speculate that progestogens other than 17-alpha hydroxyprogesterone caproate may be more efficacious in preventing preterm premature rupture of the fetal membranes-related spontaneous preterm birth.


Subject(s)
Extraembryonic Membranes/drug effects , Fetal Membranes, Premature Rupture/prevention & control , Hydroxyprogesterones/pharmacology , Progestins/pharmacology , 17 alpha-Hydroxyprogesterone Caproate , Female , Granulocyte-Macrophage Colony-Stimulating Factor/pharmacology , Hemostatics/pharmacology , Humans , In Vitro Techniques , Models, Biological , Pregnancy , Premature Birth/prevention & control , Thrombin/pharmacology , Tumor Necrosis Factor-alpha/pharmacology
9.
Acta Biomater ; 60: 210-219, 2017 09 15.
Article in English | MEDLINE | ID: mdl-28709984

ABSTRACT

Current clinical methods to treat articular cartilage lesions provide temporary relief of the symptoms but fail to permanently restore the damaged tissue. Tissue engineering, using mesenchymal stem cells (MSCs) combined with scaffolds and bioactive factors, is viewed as a promising method for repairing cartilage injuries. However, current tissue engineered constructs display inferior mechanical properties compared to native articular cartilage, which could be attributed to the lack of structural organization of the extracellular matrix (ECM) of these engineered constructs in comparison to the highly oriented structure of articular cartilage ECM. We previously showed that we can guide MSCs undergoing chondrogenesis to align using microscale guidance channels on the surface of a two-dimensional (2-D) collagen scaffold, which resulted in the deposition of aligned ECM within the channels and enhanced mechanical properties of the constructs. In this study, we developed a technique to roll 2-D collagen scaffolds containing MSCs within guidance channels in order to produce a large-scale, three-dimensional (3-D) tissue engineered cartilage constructs with enhanced mechanical properties compared to current constructs. After rolling the MSC-scaffold constructs into a 3-D cylindrical structure, the constructs were cultured for 21days under chondrogenic culture conditions. The microstructure architecture and mechanical properties of the constructs were evaluated using imaging and compressive testing. Histology and immunohistochemistry of the constructs showed extensive glycosaminoglycan (GAG) and collagen type II deposition. Second harmonic generation imaging and Picrosirius red staining indicated alignment of neo-collagen fibers within the guidance channels of the constructs. Mechanical testing indicated that constructs containing the guidance channels displayed enhanced compressive properties compared to control constructs without these channels. In conclusion, using a novel roll-up method, we have developed large scale MSC based tissue-engineered cartilage that shows microscale structural organization and enhanced compressive properties compared to current tissue engineered constructs. STATEMENT OF SIGNIFICANCE: Tissue engineered cartilage constructs made with human mesenchymal stem cells (hMSCs), scaffolds and bioactive factors are a promising solution to treat cartilage defects. A major disadvantage of these constructs is their inferior mechanical properties compared to the native tissue, which is likely due to the lack of structural organization of the extracellular matrix of the engineered constructs. In this study, we developed three-dimensional (3-D) cartilage constructs from rectangular scaffold sheets containing hMSCs in micro-guidance channels and characterized their mechanical properties and metabolic requirements. The work led to a novel roll-up method to embed 2-D microscale structures in 3-D constructs. Further, micro-guidance channels incorporated within the 3-D cartilage constructs led to the production of aligned cell-produced matrix and enhanced mechanical function.


Subject(s)
Cartilage/metabolism , Chondrogenesis , Collagen/chemistry , Mesenchymal Stem Cells/metabolism , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Animals , Cartilage/cytology , Cattle , Cells, Cultured , Humans , Mesenchymal Stem Cells/cytology
10.
J Tissue Eng Regen Med ; 11(2): 412-424, 2017 02.
Article in English | MEDLINE | ID: mdl-24965503

ABSTRACT

Scaffold-free engineered cartilage is being explored as a treatment for osteoarthritis. In this study, frictional shear stress was applied to determine the friction and damage behaviour of scaffold-free engineered cartilage, and tissue composition was investigated as it related to damage. Scaffold-free engineered cartilage frictional shear stress was found to exhibit a time-varying response similar to that of native cartilage. However, damage occurred that was not seen in native cartilage, manifesting primarily as tearing through the central plane of the constructs. In engineered cartilage, cells occupied a significantly larger portion of the tissue in the central region where damage was most prominent (18 ± 3% of tissue was comprised of cells in the central region vs 5 ± 1% in the peripheral region; p < 0.0001). In native cartilage, cells comprised 1-4% of tissue for all regions. Average bulk cellularity of engineered cartilage was also greater (68 × 103 ± 4 × 103 vs 52 × 103 ± 22 × 103 cells/mg), although this difference was not significant. Bulk tissue comparisons showed significant differences between engineered and native cartilage in hydroxyproline content (8 ± 2 vs 45 ± 3 µg HYP/mg dry weight), solid content (12.5 ± 0.4% vs 17.9 ± 1.2%), shear modulus (0.06 ± 0.02 vs 0.15 ± 0.07 MPa) and aggregate modulus (0.12 ± 0.03 vs 0.32 ± 0.14 MPa), respectively. These data indicate that enhanced collagen content and more uniform extracellular matrix distribution are necessary to reduce damage susceptibility. Copyright © 2014 John Wiley & Sons, Ltd.


Subject(s)
Cartilage, Articular/pathology , Osteoarthritis/therapy , Stress, Mechanical , Tissue Engineering/methods , Animals , Bioreactors , Cells, Cultured , Chondrocytes/cytology , Collagen/chemistry , Extracellular Matrix/chemistry , Friction , Hydroxyproline/chemistry , Pressure , Rabbits , Surface Properties
11.
Placenta ; 42: 59-73, 2016 06.
Article in English | MEDLINE | ID: mdl-27238715

ABSTRACT

Rupture of the fetal membranes (FM) is precipitated by stretch forces acting upon biochemically mediated, pre-weakened tissue. Term FM develop a para-cervical weak zone, characterized by collagen remodeling and apoptosis, within which FM rupture is thought to initiate. Preterm FM also have a weak region but are stronger overall than term FM. Inflammation/infection and decidual bleeding/abruption are strongly associated with preterm premature FM rupture (pPROM), but the specific mechanisms causing FM weakening-rupture in pPROM are unknown. There are no animal models for study of FM weakening and rupture. Over a decade ago we developed equipment and methodology to test human FM strength and incorporated it into a FM explant system to create an in-vitro human FM weakening model system. Within this model TNF (modeling inflammation) and Thrombin (modeling bleeding) both weaken human FM with concomitant up regulation of MMP9 and cellular apoptosis, mimicking the characteristics of the spontaneous FM rupture site. The model has been enhanced so that test agents can be applied directionally to the choriodecidual side of the FM explant consistent with the in-vivo situation. With this enhanced system we have demonstrated that the pathways involving inflammation/TNF and bleeding/Thrombin induced FM weakening overlap. Furthermore GM-CSF production was demonstrated to be a critical common intermediate step in both the TNF and the Thrombin induced FM weakening pathways. This model system has also been used to test potential inhibitors of FM weakening and therefore pPROM. The dietary supplement α-lipoic acid and progestogens (P4, MPA and 17α-hydroxyprogesterone) have been shown to inhibit both TNF and Thrombin induced FM weakening. The progestogens act at multiple points by inhibiting both GM-CSF production and GM-CSF action. The use of a combined biomechanical/biochemical in-vitro human FM weakening model system has allowed the pathways of fetal membrane weakening to be delineated, and agents that may be of clinical use in inhibiting these pathways to be tested.


Subject(s)
Extraembryonic Membranes/metabolism , Fetal Membranes, Premature Rupture/metabolism , Extraembryonic Membranes/physiopathology , Female , Fetal Membranes, Premature Rupture/physiopathology , Humans , Inflammation/metabolism , Inflammation/physiopathology , Matrix Metalloproteinase 9/metabolism , Pregnancy , Thrombin/metabolism , Tumor Necrosis Factor-alpha/metabolism
12.
Ann Biomed Eng ; 44(3): 733-49, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26817458

ABSTRACT

In this review, methods for evaluating the properties of tissue engineered (TE) cartilage are described. Many of these have been developed for evaluating properties of native and osteoarthritic articular cartilage. However, with the increasing interest in engineering cartilage, specialized methods are needed for nondestructive evaluation of tissue while it is developing and after it is implanted. Such methods are needed, in part, due to the large inter- and intra-donor variability in the performance of the cellular component of the tissue, which remains a barrier to delivering reliable TE cartilage for implantation. Using conventional destructive tests, such variability makes it near-impossible to predict the timing and outcome of the tissue engineering process at the level of a specific piece of engineered tissue and also makes it difficult to assess the impact of changing tissue engineering regimens. While it is clear that the true test of engineered cartilage is its performance after it is implanted, correlation of pre and post implantation properties determined non-destructively in vitro and/or in vivo with performance should lead to predictive methods to improve quality-control and to minimize the chances of implanting inferior tissue.


Subject(s)
Cartilage/cytology , Cartilage/metabolism , Diagnostic Imaging/methods , Tissue Engineering , Animals , Humans
13.
Ann Biomed Eng ; 44(5): 1515-23, 2016 May.
Article in English | MEDLINE | ID: mdl-26369634

ABSTRACT

Ultrasound elastography (UE) has been widely used as a "digital palpation" tool to characterize tissue mechanical properties in the clinic. UE benefits from the capability of noninvasively generating 2-D elasticity encoded maps. This spatial distribution of elasticity can be especially useful in the in vivo assessment of tissue engineering scaffolds and implantable drug delivery platforms. However, the detection limitations have not been fully characterized and thus its true potential has not been completely discovered. Characterization studies have focused primarily on the range of moduli corresponding to soft tissues, 20-600 kPa. However, polymeric biomaterials used in biomedical applications such as tissue scaffolds, stents, and implantable drug delivery devices can be much stiffer. In order to explore UE's potential to assess mechanical properties of biomaterials in a broader range of applications, this work investigated the detection limit of UE strain imaging beyond soft tissue range. To determine the detection limit, measurements using standard mechanical testing and UE on the same polydimethylsiloxane samples were compared and statistically evaluated. The broadest detection range found based on the current optimized setup is between 47 kPa and 4 MPa which exceeds the modulus of normal soft tissue suggesting the possibility of using this technique for stiffer materials' mechanical characterization. The detectable difference was found to be as low as 157 kPa depending on sample stiffness and experimental setup.


Subject(s)
Dimethylpolysiloxanes , Elasticity Imaging Techniques/instrumentation , Elasticity Imaging Techniques/methods , Nylons , Phantoms, Imaging , Silicone Elastomers
14.
Ann Biomed Eng ; 43(12): 2991-3003, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26077987

ABSTRACT

Tissue-engineered (TE) cartilage constructs tend to develop inhomogeneously, thus, to predict the mechanical performance of the tissue, conventional biomechanical testing, which yields average material properties, is of limited value. Rather, techniques for evaluating regional and depth-dependent properties of TE cartilage, preferably non-destructively, are required. The purpose of this study was to build upon our previous results and to investigate the feasibility of using ultrasound elastography to non-destructively assess the depth-dependent biomechanical characteristics of TE cartilage while in a sterile bioreactor. As a proof-of-concept, and to standardize an assessment protocol, a well-characterized three-layered hydrogel construct was used as a surrogate for TE cartilage, and was studied under controlled incremental compressions. The strain field of the construct predicted by elastography was then validated by comparison with a poroelastic finite-element analysis (FEA). On average, the differences between the strains predicted by elastography and the FEA were within 10%. Subsequently engineered cartilage tissue was evaluated in the same test fixture. Results from these examinations showed internal regions where the local strain was 1-2 orders of magnitude greater than that near the surface. These studies document the feasibility of using ultrasound to evaluate the mechanical behaviors of maturing TE constructs in a sterile environment.


Subject(s)
Cartilage, Articular/diagnostic imaging , Bioreactors , Cartilage, Articular/physiopathology , Cells, Cultured , Elasticity Imaging Techniques , Finite Element Analysis , Humans , Hydrogels , Mesenchymal Stem Cells , Reproducibility of Results , Stress, Mechanical , Tissue Engineering
15.
Am J Obstet Gynecol ; 213(4): 520.e1-9, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26070709

ABSTRACT

OBJECTIVE: Inflammation/infection and abruption are leading causes of preterm premature rupture of the membranes. Recently, we identified granulocyte-macrophage colony-stimulating factor (GM-CSF) as a critical mediator of both tumor necrosis factor-α- (TNF; modeling inflammation) and thrombin-induced (modeling abruption) weakening of the fetal membranes. We found that (1) TNF and thrombin both induced GM-CSF in the choriodecidua, (2) blockade of GM-CSF action with neutralizing antibodies inhibited both TNF- and thrombin-induced fetal membrane weakening, and (3) GM-CSF alone induced fetal membrane weakening. GM-CSF is thus part of an overlap of the inflammation and abruption-induced fetal membrane weakening pathways. The effects of progesterone analogs on the pathways by which fetal membranes are weakened have not been investigated. We examined the effects of progesterone, medroxyprogesterone acetate (MPA) and 17α-hydroxyprogesterone (HP) on TNF- and thrombin-induced fetal membrane weakening. STUDY DESIGN: Full-thickness fetal membranes from uncomplicated term repeat cesarean deliveries were mounted in Transwell inserts in Minimum Essential Medium alpha and incubated at 37°C in 5% CO2. The choriodecidua side of the fetal membrane fragments were preincubated with progesterone, MPA, HP, or vehicle for 24 hours. Fetal membranes were then exposed to TNF, thrombin, or GM-CSF on the choriodecidua side for an additional 48 hours. The fetal membrane tissues were then strength tested, and medium from the choriodecidua and amnion compartments was assayed for GM-CSF content. RESULTS: TNF and thrombin both weakened fetal membranes and elevated media GM-CSF levels on the choriodecidua side of the fetal membrane. Pretreatment with progesterone, MPA, or HP inhibited both TNF- and thrombin-induced fetal membrane weakening and also inhibited the induced increase in GM-CSF. GM-CSF decreased fetal membrane rupture strength by 68%, which was inhibited by progestogen pretreatment with a potency order: progesterone

Subject(s)
Chorion/drug effects , Decidua/drug effects , Granulocyte-Macrophage Colony-Stimulating Factor/pharmacology , Hemostatics/pharmacology , Progesterone/pharmacology , Progestins/pharmacology , Thrombin/pharmacology , Tumor Necrosis Factor-alpha/pharmacology , 17-alpha-Hydroxyprogesterone/pharmacology , Extraembryonic Membranes/drug effects , Female , Fetal Membranes, Premature Rupture , Humans , In Vitro Techniques , Medroxyprogesterone Acetate/pharmacology , Pregnancy
16.
J Mech Behav Biomed Mater ; 42: 10-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25460921

ABSTRACT

The feasibility of determining biphasic material properties using a finite element model of stress relaxation coupled with two types of constrained optimization to match measured data was investigated. Comparison of these two approaches, a zero-order method and a gradient-based algorithm, validated the predicted material properties. Optimizations were started from multiple different initial guesses of material properties (design variables) to establish the robustness of the optimization. Overall, the optimal values are close to those found by Cohen et al. (1998) but these small differences produced a marked improvement in the fit to the measured stress relaxation. Despite the greater deviation in the optimized values obtained from the zero-order method, both optimization procedures produced material properties that gave equally good overall fits to the measured data. Furthermore, optimized values were all within the expected range of material properties. Modeling stress relaxation using the optimized material properties showed an excellent fit to the entire time history of the measured data.


Subject(s)
Cartilage, Articular , Elasticity , Finite Element Analysis , Materials Testing , Feasibility Studies , Porosity , Stress, Mechanical
17.
J Anat ; 225(5): 519-26, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25146377

ABSTRACT

The mechanical behavior of bovine articular cartilage in shear was measured and related to its structure through the depth of the tissue. To make these measurements, we designed an apparatus that could apply controlled shear displacement and measure the resulting shear force on cartilage specimens. Shear displacement and shear strain were obtained from confocal images of photobleached lines on fluorescently stained deformed samples. Depth-dependent collagen structure was obtained using compensated polarized light microscopy. Depth-dependent shear behavior and structure of samples from two animals were measured (group A and B). Both animals were 18-24 months old, which is the range in which they are expected reach skeletal maturity. In mature samples (group A), the stiffest region was located beneath the superficial zone, and the most compliant region was found in the radial zone. In contrast, in samples that were in the process of maturing (group B) the most compliant region was located in the superficial zone. Compensated polarized light microscopy suggested that the animal from which the group A samples were obtained was skeletally mature, whereas the animal yielding the group B samples was in the process of maturing. Compensated polarized light microscopy was an important adjunct to the mechanical shear behavior in that it provided a means to reconcile differences in observed shear behavior in mature and immature cartilage. Although samples were harvested from two animals, there were clear differences in structure and shear mechanical behavior. Differences in the depth-dependent shear strain were consistent with previous studies on mature and immature samples and, based on the structural variation between mature and immature articular cartilage, their mechanical behavior differences can be tenable. These results suggest that age, as well as species and anatomic location, need to be considered when reporting mechanical behavior results.


Subject(s)
Cartilage, Articular/physiology , Shear Strength , Animals , Cartilage, Articular/anatomy & histology , Cattle
18.
Ann Biomed Eng ; 42(10): 2190-202, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25092421

ABSTRACT

Our ultimate goal is to non-destructively evaluate mechanical properties of tissue-engineered (TE) cartilage using ultrasound (US). We used agarose gels as surrogates for TE cartilage. Previously, we showed that mechanical properties measured using conventional methods were related to those measured using US, which suggested a way to non-destructively predict mechanical properties of samples with known volume fractions. In this study, we sought to determine whether the mechanical properties of samples, with unknown volume fractions could be predicted by US. Aggregate moduli were calculated for hydrogels as a function of SOS, based on concentration and density using a poroelastic model. The data were used to train a statistical model, which we then used to predict volume fractions and mechanical properties of unknown samples. Young's and storage moduli were measured mechanically. The statistical model generally predicted the Young's moduli in compression to within <10% of their mechanically measured value. We defined positive linear correlations between the aggregate modulus predicted from US and both the storage and Young's moduli determined from mechanical tests. Mechanical properties of hydrogels with unknown volume fractions can be predicted successfully from US measurements. This method has the potential to predict mechanical properties of TE cartilage non-destructively in a bioreactor.


Subject(s)
Bioreactors , Cartilage, Articular/physiology , Ultrasonics/methods , Elastic Modulus , Hydrogels , Models, Statistical , Sepharose , Stress, Mechanical , Tissue Engineering
19.
J Mech Behav Biomed Mater ; 28: 62-70, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23973614

ABSTRACT

A previously developed novel imaging technique for determining the depth dependent properties of cartilage in simple shear is implemented. Shear displacement is determined from images of deformed lines photobleached on a sample, and shear strain is obtained from the derivative of the displacement. We investigated the feasibility of an alternative systematic approach to numerical differentiation for computing the shear strain that is based on fitting a continuous function to the shear displacement. Three models for a continuous shear displacement function are evaluated: polynomials, cubic splines, and non-parametric locally weighted scatter plot curves. Four independent approaches are then applied to identify the best-fit model and the accuracy of the first derivative. One approach is based on the Akaiki Information Criteria, and the Bayesian Information Criteria. The second is based on a method developed to smooth and differentiate digitized data from human motion. The third method is based on photobleaching a predefined circular area with a specific radius. Finally, we integrate the shear strain and compare it with the total shear deflection of the sample measured experimentally. Results show that 6th and 7th order polynomials are the best models for the shear displacement and its first derivative. In addition, failure of tissue-engineered cartilage, consistent with previous results, demonstrates the qualitative value of this imaging approach.


Subject(s)
Cartilage, Articular/cytology , Materials Testing , Shear Strength , Stress, Mechanical , Tissue Engineering , Animals , Cattle , Feasibility Studies , Humans
20.
J Biomech ; 46(11): 1921-7, 2013 Jul 26.
Article in English | MEDLINE | ID: mdl-23796400

ABSTRACT

The feasibility of determining biphasic material properties using regression models was investigated. A transversely isotropic poroelastic finite element model of stress relaxation was developed and validated against known results. This model was then used to simulate load intensity for a wide range of material properties. Linear regression equations for load intensity as a function of the five independent material properties were then developed for nine time points (131, 205, 304, 390, 500, 619, 700, 800, and 1000s) during relaxation. These equations illustrate the effect of individual material property on the stress in the time history. The equations at the first four time points, as well as one at a later time (five equations) could be solved for the five unknown material properties given computed values of the load intensity. Results showed that four of the five material properties could be estimated from the regression equations to within 9% of the values used in simulation if time points up to 1000s are included in the set of equations. However, reasonable estimates of the out of plane Poisson's ratio could not be found. Although all regression equations depended on permeability, suggesting that true equilibrium was not realized at 1000s of simulation, it was possible to estimate material properties to within 10% of the expected values using equations that included data up to 800s. This suggests that credible estimates of most material properties can be obtained from tests that are not run to equilibrium, which is typically several thousand seconds.


Subject(s)
Cartilage, Articular/physiology , Models, Biological , Biomechanical Phenomena , Computer Simulation , Elasticity/physiology , Finite Element Analysis , Humans , Linear Models , Porosity , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...