Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-35640134

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the mid-term outcomes after the repair of aortic arch using a standard patch augmentation technique. METHODS: The study included all patients who underwent repair of a hypoplastic/interrupted aortic arch (IAA) in a single institute from June 2012 to December 2019 by a standardized patch augmentation (irrespective of concomitant intra-cardiac lesions). End points evaluated were reintervention for arch obstruction and persistent/new-onset hypertension. RESULTS: The study included 149 patients [hypoplastic aortic arch, n = 92 (62%), IAA, n = 9 (6%), Norwood procedure, n = 48 (32%)]. The patch material used for augmentation of the aortic arch included pulmonary homograft (n = 120, 81%), homograft pericardium (n = 18, 12%), CardioCel® (n = 9, 6%) and glutaraldehyde-treated autologous pericardium (n = 2, 1%). The median age and weight at surgery were 7 days [interquartile range (IQR) 5-17 days] and 3.5 kg (IQR 3-3.9 kg), respectively. The median follow-up was 3.27 years (IQR 1.28, 5.08), range (0.02, 8.76). Freedom from reintervention at 1, 3 and 5 years was 95% [95% confidence interval (CI) = 89%, 98%], 93% (95% CI = 86%, 96%) and 93% (95% CI = 86%, 96%) respectively. One patient (0.6%) had persistent hypertension 8 years after correction for interrupted arch with truncus arteriosus. CONCLUSIONS: Repair of hypoplastic/IAA by transection and excision of all ductal tissue and standardized patch augmentation provide good mid-term durability. The freedom from reintervention at 5 years is >90%. The incidence of persistent systemic hypertension following arch reconstruction is low. The technique is reproducible and applicable irrespective of underlying arch anatomy.


Subject(s)
Aortic Coarctation , Hypertension , Norwood Procedures , Aorta, Thoracic , Follow-Up Studies , Humans , Infant , Retrospective Studies , Treatment Outcome
2.
Ann Thorac Surg ; 110(2): 646-653, 2020 08.
Article in English | MEDLINE | ID: mdl-31891693

ABSTRACT

BACKGROUND: Heterotaxy is considered a risk factor for poor outcomes after the Fontan operation. However, long-term data to support this notion are lacking. The aims of this study were to ascertain the long-term outcomes of patients with heterotaxy after hospital discharge after Fontan completion and to compare these outcomes with those of a contemporary nonheterotaxy cohort. METHODS: A binational Fontan registry (n = 1540) was analyzed to identify patients with heterotaxy and compare them with patients without heterotaxy. The primary composite end point was Fontan failure, encompassing death, heart transplantation, Fontan takedown or conversion, protein-losing enteropathy, plastic bronchitis, or New York Heart Association functional class III or IV. RESULTS: A total of 109 patients with heterotaxy were identified and they were compared with 1431 nonheterotaxy patients after Fontan completion. There was no difference in unadjusted 15-year freedom from Fontan failure (heterotaxy, 78% vs nonheterotaxy, 85%; P = .2). Patients in the heterotaxy group had a significantly higher cumulative incidence of post-Fontan arrhythmias (P < .001). Propensity-score matching for confounders yielded 73 patients with heterotaxy matched with 439 patients without heterotaxy, in whom 15-year freedom from Fontan failure was also not different (heterotaxy, 76% vs nonheterotaxy, 81%; P = .2). There was no difference in 15-year freedom from Fontan failure in patients with right vs left isomerism (right isomerism, 80% vs left isomerism, 76%; P = .7). CONCLUSIONS: Although heterotaxy may complicate the pre-Fontan course, once the Fontan procedure is successfully completed, heterotaxy does not appear to be an important risk factor for Fontan failure. Patients with heterotaxy are at a higher risk of post-Fontan arrhythmias compared with patients without heterotaxy.


Subject(s)
Fontan Procedure/methods , Heart Defects, Congenital/surgery , Heterotaxy Syndrome/complications , Postoperative Complications/epidemiology , Registries , Adolescent , Adult , Australia/epidemiology , Child , Child, Preschool , Female , Follow-Up Studies , Heart Defects, Congenital/complications , Heart Defects, Congenital/mortality , Humans , Incidence , Infant , Infant, Newborn , Male , New Zealand/epidemiology , Propensity Score , Survival Rate/trends , Time Factors , Treatment Outcome , Young Adult
3.
Ann Pediatr Cardiol ; 10(1): 5-10, 2017.
Article in English | MEDLINE | ID: mdl-28163422

ABSTRACT

BACKGROUND: Perforation of pulmonary valve using radiofrequency ablation in pulmonary atresia with intact ventricular septum (PA IVS) is a treatment of choice. However, significant cost of the equipment limits its utility, especially in the developing economies. OBJECTIVE: To assess the feasibility, safety, and efficacy of perforation of pulmonary valve using chronic total occlusion (CTO) wires in patients with PA IVS as an alternative to radiofrequency ablation. METHODS: This is a single-center, nonrandomized, retrospective study conducted during June 2008 to September 2015. Twenty-four patients with PA IVS were selected for the procedure during the study period. The median age and weight of the study population were 8. days and 2.65 kg, respectively. Four patients were excluded after right ventricular angiogram as they showed right ventricular-dependent coronary circulation. The pulmonary valve perforation was attempted using various types of CTO wires based on the tip load with variable penetrating characteristics. RESULTS: The procedure was successful in 16 of twenty patients using CTO wires: Shinobi in nine, Miracle in four, CROSS-IT in two, and Conquest Pro in one. Two patients had perforation of right ventricular outflow tract (RVOT). Pericardiocentesis was required in one patient to relieve cardiac tamponade. Later, the same patient underwent successful hybrid pulmonary valvotomy. The other patient underwent ductus arteriosus (DA) stenting. Balloon atrial septostomy was needed in three cases with systemic venous congestion. Desaturation was persistent in five cases necessitating DA or RVOT stenting to augment pulmonary blood flow. There were two early and two late deaths. The mean follow-up was 22.66 ± 16 months. Three patients underwent one and half ventricle repair and one Blalock-Taussig shunt during follow-up. CONCLUSION: Perforation of the pulmonary valve can be done successfully using CTO wires in selected cases of pulmonary atresia with intact ventricular septum.

SELECTION OF CITATIONS
SEARCH DETAIL
...