Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(9)2022 Apr 21.
Article in English | MEDLINE | ID: mdl-35590883

ABSTRACT

We exploited the potential of radiation-induced emissions (RIEs) in the visible domain of a nitrogen-doped, silica-based, multimode optical fiber to monitor the very high dose rates associated with experiments at different pulsed X-ray facilities. We also tested this sensor at lower dose rates associated with steady-state X-ray irradiation machines (up to 100 keV photon energy, mean energy of 40 keV). For transient exposures, dedicated experimental campaigns were performed at ELSA (Electron et Laser, Source X et Applications) and ASTERIX facilities from CEA (Commissariat à l'Energie Atomique-France) to characterize the RIE of this fiber when exposed to X-ray pulses with durations of a few µs or ns. These facilities provide very large dose rates: in the order of MGy(SiO2)/s for the ELSA facility (up to 19 MeV photon energy) and GGy(SiO2)/s for the ASTERIX facility (up to 1 MeV). In both cases, the RIE intensities, mostly explained by the fiber radioluminescence (RIL) around 550 nm, with a contribution from Cerenkov at higher fluxes, linearly depend on the dose rates normalized to the pulse duration delivered by the facilities. By comparing these high dose rate results and those acquired under low-dose rate steady-state X-rays (only RIL was present), we showed that the RIE of this multimode optical fiber linearly depends on the dose rate over an ultra-wide dose rate range from 10-2 Gy(SiO2)/s to a few 109 Gy(SiO2)/s and photons with energy in the range from 40 keV to 19 MeV. These results demonstrate the high potential of this class of radiation monitors for beam monitoring at very high dose rates in a very large variety of facilities as future FLASH therapy facilities.


Subject(s)
Optical Fibers , Radiometry , Nitrogen , Radiometry/methods , Silicon Dioxide , X-Rays
2.
Sensors (Basel) ; 17(2)2017 Feb 17.
Article in English | MEDLINE | ID: mdl-28218652

ABSTRACT

We investigated the evolution of the performances of Pulse Pre Pump-Brillouin Time Domain Analysis (PPP-BOTDA) and Tunable Wavelength Coherent Optical Time Domain Reflectometry (TW-COTDR) fiber-based temperature and strain sensors when the sensing optical fiber is exposed to two γ-ray irradiation conditions: (i) at room temperature and a dose rate of 370 Gy(SiO2)/h up to a total ionizing dose (TID) of 56 kGy; (ii) at room temperature and a dose rate of 25 kGy(SiO2)/h up to a TID of 10 MGy. Two main different classes of single-mode optical fibers have been tested in situ, radiation-tolerant ones: fluorine-doped or nitrogen-doped core fibers, as well as Telecom-grade germanosilicate ones. Brillouin and Rayleigh Sensitivities of N-Doped fibers were not reported yet, and these characterizations pave the way for a novel and alternative sensing scheme. Moreover, in these harsh conditions, our results showed that the main parameter affecting the sensor sensitivity remains the Radiation Induced Attenuation (RIA) at its operation wavelength of 1550 nm. RIA limits the maximal sensing range but does not influence the measurement uncertainty. F-doped fiber is the most tolerant against RIA with induced losses below 8 dB/km after a 56 kGy accumulated dose whereas the excess losses of other fibers exceed 22 dB/km. Both Rayleigh and Brillouin signatures that are exploited by the PPP-BOTDA and the TW-COTDR remain unchanged (within our experimental uncertainties). The strain and temperature coefficients of the various fibers under test are not modified by radiations, at these dose/dose rate levels. Consequently, this enables the design of a robust strain and temperature sensing architecture for the monitoring of radioactive waste disposals.

3.
Opt Express ; 23(7): 8659-69, 2015 Apr 06.
Article in English | MEDLINE | ID: mdl-25968704

ABSTRACT

We compared the sensitivity to X-rays of several fiber Bragg gratings (FBGs) written in the standard telecommunication fiber Corning SMF28 with different techniques. Standard gratings were manufactured with phase-mask and UV lasers, continuum wave (cw) at 244 nm or pulsed in the nanosecond domain at 248 nm, in a pre-hydrogenated fiber. Others gratings were written by exposures to a femtosecond IR-laser (800 nm), with both phase-mask and point by point techniques. The response of these FBGs was studied under X-rays at room temperature and 100°C, by highlighting their similarities and differences. Independently of the inscription technique, the two types of fs-FBGs have showed no big difference up to 1 MGy(SiO(2)) dose. A discussion on the causes of the radiation-induced peak change is also reported.

4.
Opt Express ; 20(8): 8457-65, 2012 Apr 09.
Article in English | MEDLINE | ID: mdl-22513553

ABSTRACT

We investigated the efficiencies of two different approaches to increase the radiation hardness of optical amplifiers through development of improved rare-earth (RE) doped optical fibers. We demonstrated the efficiency of codoping with Cerium the core of Erbium/Ytterbium doped optical fibers to improve their radiation tolerance. We compared the γ-rays induced degradation of two amplifiers with comparable pre-irradiation characteristics (~19 dB gain for an input power of ~10 dBm): first one is made with the standard core composition whereas the second one is Ce codoped. The radiation tolerance of the Ce-codoped fiber based amplifier is strongly enhanced. Its output gain decrease is limited to ~1.5 dB after a dose of ~900 Gy, independently of the pump power used, which authorizes the use of such fiber-based systems for challenging space missions associated with high total doses. We also showed that the responses of the two amplifiers with or without Ce-codoping can be further improved by another technique: the pre-loading of these fibers with hydrogen. In this case, the gain degradation is limited to 0.4 dB for the amplifier designed with the standard composition fiber whereas 0.2 dB are reported for the one made with Ce-codoped fiber after a cumulated dose of ~900 Gy. The mechanisms explaining the positive influences of these two treatments are discussed.

SELECTION OF CITATIONS
SEARCH DETAIL
...