Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Vascular ; 13(5): 268-74, 2005.
Article in English | MEDLINE | ID: mdl-16288701

ABSTRACT

Autologous arteriovenous access is the key to long-term success with hemodialysis and is strongly supported by the National Kidney Foundation's Dialysis Outcomes Quality Initiative guidelines. Basilic vein transposition (BVT) fulfills the need for a durable conduit with high patency and maturation rates. This retrospective review examines a single group's experience with this procedure. All patients undergoing BVT for hemodialysis with available follow-up data were reviewed. Telephone interviews were used to supplement clinical data where needed. Functional assisted patency was used as the end point for this procedure, and if the access was never used for dialysis, then the patency was considered zero. Secondary interventions performed while the access remained patent and in use were not considered detrimental to the patency reported. One hundred seventy BVTs in 162 patients were performed between November 1992 and October 2001. There were 87 women (53.7%) and 112 black patients (69.1%); hypertension was present in 138 patients (85.2%) and diabetes in 89 patients (54.9%). Each year, an increasing incidence of BVT was performed in our dialysis population. The BVT was performed as the first access in that extremity in 73 of the procedures (42.9%). Functional patency (primary assisted) was achieved in 40.0% at 2 years and 15.2% at 5 years. The mean assisted patency was 14.6 months. To maintain BVT patency, 40 percutaneous secondary interventions (69.0%) and 18 surgical revisions (31.0%) occurred in 32 patients (19.0%). Ligation for swelling was necessary in 4 patients (2.5%), and steal syndrome occurred in 3 patients (1.9%). BVT is a useful autologous procedure for hemodialysis and the preferred access alternative in patients without an adequate cephalic vein. Although patencies remain poor relative to other conventional arterial vascular procedures, BVT is our most durable hemodialysis access procedure and is often the only available autologous conduit for hemodialysis.


Subject(s)
Arteriovenous Shunt, Surgical/methods , Forearm/blood supply , Renal Dialysis/methods , Brachial Artery/surgery , Catheterization, Central Venous/methods , Diabetic Nephropathies/complications , Female , Humans , Hypertension/complications , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/therapy , Male , Middle Aged , Postoperative Complications , Reoperation , Retrospective Studies , Treatment Outcome , Vascular Patency/physiology , Veins , Venous Thrombosis/surgery
2.
Vasc Endovascular Surg ; 39(2): 143-51, 2005.
Article in English | MEDLINE | ID: mdl-15806275

ABSTRACT

Clinical management of carotid disease is primarily based on results of national trials (ACAS and NASCET) that used the distal internal carotid artery diameter as a reference. However, commonly accepted ultrasound (US) criteria for carotid stenosis were derived from the correlation of velocity measurements with angiographic bulb diameter reductions (BDR). This study was undertaken to compare the degree of carotid stenosis determined by conventional velocity criteria to the degree of stenosis measured by B-mode (gray scale) diameter at both the carotid bulb and at the distal internal carotid artery, and, second, to evaluate US imaging to derive distal diameter reductions (DDR) noninvasively. During a 3-month period patients referred for carotid US were prospectively analyzed for standard velocity criteria and plaque morphology. Minimum carotid diameter was measured by longitudinal and transverse B-mode measurements and compared to carotid bulb diameter and internal carotid diameter distal to all disease. B-mode diameter reductions were compared to the degree of stenosis determined by velocity criteria and to patient symptoms and the decision for carotid endarterectomy. In total, 131 carotid arteries in 74 patients were evaluated. Based on the University of Washington velocity criteria, lesions were classified as grade I (n = 61, 46%), IIA (n = 58, 44%), IIB (n = 7, 5%), or III (n = 5, 4%). BDR measured by B-mode predicted the grade of disease based on velocity criteria (p < 0.001) with an overall accuracy of 95%. With use of the B-mode for DDR (NASCET style), 18 patients exceeded the 60% threshold for surgical intervention. Of these, only 3 patients were symptomatic and were operated on. An additional 3 operated-on patients had an asymptomatic grade III stenosis, our usual threshold for intervention. Twelve additional patients were appropriate for surgical intervention by B-mode but were not treated based on conventional velocity criteria alone. Bulb diameter reduction by B-mode imaging correlates strongly with diameter reduction determined by velocity criteria, and independently predicts the grade of carotid disease. With this in mind, the accuracy of B-mode imaging may be extended to the measurement of carotid stenosis based on DDR. By B-mode criteria, many patients appropriate for intervention were not offered treatment based on conventional velocity criteria. Modern B-mode imaging provides a noninvasive method to obtain 'arteriographic equivalent'' measurements and should be added as a routine to carotid ultrasound interrogation.


Subject(s)
Carotid Arteries/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/physiopathology , Blood Flow Velocity/physiology , Carotid Arteries/surgery , Carotid Stenosis/classification , Carotid Stenosis/surgery , Endarterectomy, Carotid , Humans , Prospective Studies , Reference Values , Sensitivity and Specificity , Ultrasonography, Doppler, Color , Ultrasonography, Doppler, Duplex
3.
J Vasc Surg ; 40(3): 443-7, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15337871

ABSTRACT

OBJECTIVES: The endovascular management of abdominal aortic aneurysm (AAA) relies on accurate preoperative imaging for proper patient selection and operative planning. Three-dimensional (3-D) computed tomography (CT) with reformatted images perpendicular to blood flow has gained popularity as a method of AAA assessment and image-based planning before endovascular aneurysm repair (EVAR). The current study was undertaken to determine the interobserver agreement of AAA measurements obtained with axial CT and reformatted 3-D CT and to compare the consistency of the 2 methods in selecting patients for EVAR. METHODS: Eight observers assessed the axial CT and reformatted 3-D CT scans for 5 patients with AAAs to determine whether the patients were candidates for EVAR. 3-D CT with multiplanar reformatted images was performed by Medical Media Systems (MMS). Each observer measured the length and diameter of the proximal neck, maximal AAA, aortic bifurcation, common iliac diameter, and aortic angulation. The proximal neck and common iliac arteries were also assessed for thrombus, calcification, and tortuosity. Agreement of the measurements on axial CT scans was compared with those on MMS CT scans by calculating the kappa statistic. Complete agreement was defined as kappa = 1.0. The limits of agreement between observers were also calculated. RESULTS: The cumulative interobserver agreement of MMS CT scans (kappa =.81) was greater than for axial CT scans (kappa =.59). The kappa value for each of the diameter measurements was greater with the MMS CT scans. In 79% of cases the observers' measurements were less than 2 mm from the mean with MMS CT, compared with 59% for axial CT. The kappa value for deciding whether a patient was an endograft candidate on the basis of aortic neck was greater with the MMS CT (0.92 vs 0.63). The limits of agreement between observers were also better with the MMS CT. CONCLUSIONS: The interobserver agreement in planning EVAR is significantly better with MMS CT compared with traditional axial CT. The routine use of MMS CT appears justified before EVAR to improve the accuracy and consistency of patient selection.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/statistics & numerical data , Angioplasty , Aortic Aneurysm, Abdominal/surgery , Humans , Observer Variation , Patient Selection , Preoperative Care
4.
J Vasc Surg ; 36(6): 1154-60, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12469046

ABSTRACT

PURPOSE: Temporal arteritis (TA) is frequently diagnosed with nonspecific clinical characteristics, followed by a temporal artery biopsy to confirm the presence of vasculitis. Consequently, numerous screening surgical biopsies are performed with a high negative-biopsy rate. A prospective study was performed evaluating color duplex ultrasound scan (CDU) as the preferred method for the diagnosis of vasculitis in the evaluation of suspected TA. METHODS: Thirty-two patients with suspected TA on the basis of clinical criteria were evaluated with CDU before a temporal artery biopsy. The presence of a hypoechoic "halo," suggesting edema of the inflamed vessel, and inflammatory stenoses were noted. Histologic examinations of standard temporal artery biopsies then were performed, and the results were compared with the CDU findings. In addition, a metaanalysis was performed to identify articles related to the use of ultrasound scan in the detection of TA. RESULTS: All patients completed a bilateral CDU examination of the temporal arteries, and in 75% of patients biopsied, no evidence of vasculitis was found at histologic examination. When CDU examined for halo alone as the determinant for disease, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), compared with histologic confirmation of TA, were 85.7%, 92.0%, 75.0%, and 95.8%, respectively. With the criteria for a halo sign present, an inflammatory stenosis present, or both present on CDU, the sensitivity, specificity, positive predictive value, and NPV were 100%, 80.0%, 58.3%, and 100%, respectively. CONCLUSION: CDU is a superior noninvasive method of determining the presence of vasculitis when compared with routine surgical biopsy. Examination of the temporal artery with CDU can effectively predict which patient will need surgical biopsy. The utility of CDU in the diagnosis of TA is maintained by a high sensitivity in detecting patients with the disease and also by a high NPV that can eliminate patients who would not benefit from biopsy.


Subject(s)
Giant Cell Arteritis/diagnostic imaging , Ultrasonography, Doppler, Color , Aged , Aged, 80 and over , Cohort Studies , Female , Giant Cell Arteritis/pathology , Giant Cell Arteritis/surgery , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
5.
J Vasc Surg ; 35(3): 474-81, 2002 Mar.
Article in English | MEDLINE | ID: mdl-11877694

ABSTRACT

PURPOSE: The purpose of this study was the demonstration of the value of color duplex ultrasound (CDU) scanning in the detection of type I endoleak (T1EL) and type II endoleak (T2EL), the correlation of Doppler scan waveform pattern to endoleak persistence or seal, and the description of the natural history of endoleak. METHODS: The study was a retrospective review of 83 patients who underwent periodic CDU scan and computed tomographic (CT) scan surveillance of the endograft and aneurysm sac after insertion of an aortic endograft for abdominal aortic aneurysm (AAA). Forty-one patients (49%) with an endoleak at anytime in the follow-up period form the basis of this report. RESULTS: T1EL was detected in all five patients with CDU and CT scans. T2EL was detected in 36 patients with CDU scan as compared with 18 patients with CT scan. With CT scan, endoleak was not detected when CDU scan showed no endoleak. Conversely, all CT scan--detected endoleaks were found with CDU scanning. The T2EL source artery was identified with CT scan in seven patients, whereas the source was identified in all 36 patients with CDU scan. Endoleak source did not correlate with outcome (seal or persistence). However, a to/fro Doppler scan waveform pattern was associated with spontaneous T2EL seal in seven of 12 patients, and a monophasic or biphasic waveform was associated with endoleak persistence in 14 of 17 patients (P =.023, with chi(2) test). Thirteen of 36 T2ELs underwent spontaneous seal by 6.2 +/- 2.8 months. T2ELs without increasing AAA diameter were observed. Eight patients with persistent T2EL present for more than 12 months did not undergo treatment. However, two patients underwent T2EL obliteration with coils because of AAA sac enlargement. T1EL of the distal attachment site was the initial endoleak identified in five patients, but seven patients harboring T2ELs had subsequent T1ELs develop. For the entire 83 patients, the combined T1EL and T2EL prevalence rate was 20% of patients at a 6-month follow-up period, but this rate increased to 50% after 24 months. The incidence rate of newly detected endoleaks and of spontaneous sealing was 24.4% at 12 months and 12.5% in longer-term follow-up period. CONCLUSION: CDU scan is effective in the identification of the type of endoleak, the delineation of the vessel involved, and the hemodynamic information not available with any other testing method. Endoleaks have a dynamic natural history characterized by a variable onset with changing branch vessel involvement and spectral flow patterns. Periodic long-term endograft surveillance with CDU scanning is necessary for following existing endoleaks and for detecting new ones. Corroboration of these findings in larger multicenter prospective trials will be needed to determine whether CDU scan analysis of endoleaks would be predictive of long-term success in endovascular AAA repair.


Subject(s)
Aortic Aneurysm, Abdominal/diagnosis , Blood Vessel Prosthesis Implantation/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/surgery , Follow-Up Studies , Humans , Incidence , Postoperative Complications/diagnosis , Retrospective Studies , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Ultrasonography, Doppler, Color , Vascular Surgical Procedures
SELECTION OF CITATIONS