Results 1 - 20 de 69
Filter
1.
Acta otorrinolaringol. esp ; 75(1): 23-30, ene.-feb. 2024. tab, graf
Article in Spanish | IBECS | ID: ibc-229268

ABSTRACT

Introducción El umbral de confort máximo o maximum comfort level (MCL), umbral eléctrico o threshold level (THR) e impedancia eléctrica cambian en el postoperatorio del implante coclear durante meses hasta estabilizarse. El objetivo de este artículo es establecer la variación durante cinco años posquirúrgicos de la impedancia, y su relación con MCL en adultos implantados unilateralmente. Métodos Estudio retrospectivo a cinco años, con 78 pacientes adultos implantados con MED-EL en un hospital terciario desde el año 2000 hasta 2015. Se analizó la variación de impedancia, MCL y relación entre ellos, en electrodos basales (9-12), medios (5-8) y apicales (1-4), realizando análisis inferencial ANOVA de medidas repetidas con comparaciones entre tiempos consecutivos, corregidas con criterio Bonferroni. Resultados Treinta y tres hombres (42,3%) y 45 mujeres (57,7%), con edad media 52,7 ± 14,6 años. Se consideró «estabilidad» el momento del seguimiento sin diferencias estadísticamente significativas entre una visita y la siguiente. Los cambios en la impedancia en electrodos medios dejaron de ser estadísticamente significativos a los tres meses, y en apicales a los seis meses, con valores medios de 5,84 y 6,43 kohms. MCL se estabilizó a los dos años en electrodos basales y apicales, y a los tres años en medios, con valores medios de 24,9, 22,7 y 25,6 qu. Hubo correlación entre MCL e impedancia en electrodos medios hasta 3 meses y en apicales hasta un año. Conclusiones La impedancia eléctrica desciende significativamente en electrodos medios y apicales hasta tres y seis meses. El MCL aumenta significativamente hasta dos años. La impedancia se relaciona con MCL hasta seis meses. (AU)


Introduction The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. Methods Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. Results 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7 ± 14.6 years. “Stability” was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43 kohms. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6 qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. Conclusions Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months. (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Electric Impedance , Cochlear Implants/adverse effects , Telemetry , Retrospective Studies
2.
Article in English | MEDLINE | ID: mdl-38224870

ABSTRACT

INTRODUCTION: The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. METHODS: Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. RESULTS: 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7±14.6 years. "Stability" was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43kΩ. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. CONCLUSIONS: Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months.


Subject(s)
Cochlear Implantation , Cochlear Implants , Male , Adult , Humans , Female , Middle Aged , Aged , Electric Impedance , Retrospective Studies , Auditory Threshold
3.
Article in English | MEDLINE | ID: mdl-35397830

ABSTRACT

BACKGROUND AND OBJECTIVE: Osseointegrated auditory devices are hearing gadgets that use the bone conduction of sound to produce hearing improvement. The mechanisms and factors that contribute to this sound transmission have been widely studied, however, there are other aspects that remain unknown, for instance, the influence of the processor power output. The aim of this study was to know if there is any relationship between the power output created by the devices and the hearing improvement that they achieve. MATERIALS Y METHODS: 44 patients were implanted with a percutaneous Baha® 5 model. Hearing thresholds in pure tone audiometry, free-field audiometry, and speech recognition (in quiet and in noise) were measured pre and postoperatively in each patient. The direct bone conduction thresholds and the power output values from the processors were also obtained. RESULTS: The pure tone average threshold in free field was 39.29 dB (SD = 9.15), so that the mean gain was 29.18 dB (SD = 10.13) with the device. This involved an air-bone gap closure in 63.64% of patients. The pure tone average threshold in direct bone conduction was 27.6 dB (SD = 10.91), which was 8.4 dB better than the pure tone average threshold via bone conduction. The mean gain in speech recognition was 39.15% (SD = 23.98) at 40 dB and 36.66% (SD = 26.76) at 60 dB. The mean gain in the signal-to-noise ratio was -5.9 dB (SD = 4.32). On the other hand, the mean power output values were 27.95 dB µN (SD = 6.51) in G40 and 26.22 dB µN (SD = 6.49) in G60. When analysing the relationship between bone conduction thresholds and G40 and G60 values, a correlation from the frequency of 1000 Hz was observed. However, no statistically significant association between power output, functional gain or speech recognition gain was found. CONCLUSIONS: The osseointegrated auditory devices generate hearing improvement in tonal thresholds and speech recognition, even in noise. Most patients closed the air-bone gap with the device. There is a direct relationship between the bone conduction threshold and the power output values from the processor, but only in mid and high frequencies. However, the relationship between power output and gain in speech recognition is weaker. Further investigation of contributing factors is necessary.


Subject(s)
Hearing Aids , Speech Perception , Audiometry, Pure-Tone , Auditory Threshold , Hearing , Humans
6.
Article in English, Spanish | MEDLINE | ID: mdl-34082922

ABSTRACT

BACKGROUND AND OBJECTIVE: Osseointegrated auditory devices are hearing gadgets that use the bone conduction of sound to produce hearing improvement. The mechanisms and factors that contribute to this sound transmission have been widely studied, however, there are other aspects that remain unknown, for instance, the influence of the processor power output. The aim of this study was to know if there is any relationship between the power output created by the devices and the hearing improvement that they achieve. MATERIALS AND METHODS: Forty-four patients were implanted with a percutaneous Baha® 5 model. Hearing thresholds in pure tone audiometry, free-field audiometry, and speech recognition (in quiet and in noise) were measured pre and postoperatively in each patient .The direct bone conduction thresholds and the power output values from the processors were also obtained. RESULTS: The pure tone average threshold in free field was 39.29dB (SD 9.15), so that the mean gain was 29.18dB (SD 10.13) with the device. This involved an air-bone gap closure in 63.64% of patients. The pure tone average threshold in direct bone conduction was 27.6dB (SD 10.91), which was 8.4dB better than the pure tone average threshold via bone conduction. The mean gain in speech recognition was 39.15% (SD 23.98) at 40dB and 36.66% (SD 26.76) at 60dB. The mean gain in the signal-to-noise ratio was -5.9dB (SD 4.32). On the other hand, the mean power output values were 27.95dB µN (SD 6.51) in G40 and 26.22dB µN (SD 6.49) in G60. When analysing the relationship between bone conduction thresholds and G40 and G60 values, a correlation from the frequency of 1,000Hz was observed. However, no statistically significant association between power output, functional gain or speech recognition gain was found. CONCLUSIONS: The osseointegrated auditory devices generate hearing improvement in tonal thresholds and speech recognition, even in noise. Most patients closed the air-bone gap with the device. There is a direct relationship between the bone conduction threshold and the power output values from the processor, but only in mid and high frequencies. However, the relationship between power output and gain in speech recognition is weaker. Further investigation of contributing factors is necessary.

7.
J Oral Rehabil ; 48(8): 927-936, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33977548

ABSTRACT

BACKGROUND: The efficiency of the mandibular advancement device (MAD) in patients with obstructive sleep apnoea syndrome (OSAS) has been demonstrated. Nevertheless, the behaviour of the upper airway once MAD is placed and titrated, and its correlation with the apnoea-hypopnoea index (AHI) is still under discussion. OBJECTIVES: To analyse the morphological changes of the upper airway through a bi- and three-dimensional study and correlate it with the polysomnographic variable, AHI. METHODS: Patients were recruited from two different hospitals for the treatment of OSAS with a custom-made MAD. A cone-beam computer tomography and a polysomnography were performed at baseline and once the MAD was titrated. RESULTS: A total of 41 patients completed the study. Treatment with MAD reduced the AHI from 22.5 ± 16.8 to 9.2 ± 11.6 (p ≤ .05). There was a significant increase of the total airway volume with MAD from 21.83 ± 7.05 cm3 to 24.19 ± 8.19 cm3 , at the expense of the oropharynx. Moreover, the correlation between the improvement of the AHI and the augmentation of the volume of the upper airway was not statistically significant. CONCLUSIONS: The oral device used in this prospective study increased the mean upper pharyngeal airway volume and significantly reduced the AHI. Future studies that measure the muscular tone are needed to completely understand the association between the AHI and the physiological and anatomical response of the upper airway.


Subject(s)
Mandibular Advancement , Sleep Apnea, Obstructive , Humans , Occlusal Splints , Polysomnography , Prospective Studies , Sleep Apnea, Obstructive/diagnostic imaging , Sleep Apnea, Obstructive/therapy , Treatment Outcome
8.
Am J Rhinol Allergy ; 35(4): 516-524, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33153272

ABSTRACT

BACKGROUND: Chronic rhinosinusitis with nasal polyps (CRSwNP) is a clinical entity with specific features that impacts significantly on patient quality of life (QoL). CRSwNP is often associated with asthma and is difficult to control and manage despite pharmacological and/or surgical treatment. Omalizumab, a monoclonal anti-IgE antibody, has emerged as a putative therapeutic option. OBJECTIVE: To evaluate the effects of omalizumab on nasal polyp (NP) size and QoL assessed by Sino-Nasal Outcome Test-22 (SNOT-22) in patients with recalcitrant CRSwNP and mild asthma. METHODS: A multicenter retrospective analysis of patient data from the Community of Valencia (Spain) was performed. Adult patients with recalcitrant CRSwNP and comorbid mild asthma receiving compassionate use of omalizumab were included. NP size measured by total nasal endoscopic polyp score (TPS) and QoL evaluated through the SNOT-22 questionnaire were assessed at baseline and monthly over 12 months. An ordinal regression model was built to analyze the results. RESULTS: A total of 23 CRSwNP patients with a mean age (± SD) of 54.78 ± 9.46 years were included. Nineteen suffered from aspirin-exacerbated respiratory disease (AERD). In all patients, a significant and sustained reduction in TPS was observed over time, accompanied by improvements in QoL reflected in lower SNOT-22 scores. In the ordinal regression model, time but not total IgE, age or tissue eosinophilia impacted on NP size and SNOT-22 outcomes. Additionally, improvements in QoL were not explained by reductions in the size of polyps. CONCLUSION: Omalizumab was effective for the treatment of patients with recalcitrant CRSwNP and mild asthma, even when AERD was present, by reducing NP size and improving QoL; treatment time was a key factor. SNOT-22 improvements were not explained by decreases in TPS, indicating that omalizumab may be effective in all patients, regardless of polyp size.


Subject(s)
Asthma , Nasal Polyps , Rhinitis , Adult , Asthma/complications , Asthma/drug therapy , Asthma/epidemiology , Chronic Disease , Humans , Nasal Polyps/drug therapy , Omalizumab/therapeutic use , Quality of Life , Retrospective Studies , Rhinitis/drug therapy , Treatment Outcome
10.
Front Neurol ; 11: 106, 2020.
Article in English | MEDLINE | ID: mdl-32231633

ABSTRACT

Background: It is hypothesized that, for patients with hearing loss, surgically placing an implant/abutment combination whilst leaving the subcutaneous tissues intact will improve cosmetic and clinical results, increase quality of life (QoL) for the patient, and reduce medical costs. Here, incremental costs and consequences associated with soft tissue preservation surgery with a hydroxyapatite (HA)-coated abutment (test) were compared with the conventional approach, soft tissue reduction surgery with an all-titanium abutment (control). Methods: A cost-consequence analysis was performed based on data gathered over a period of 3 years in an open randomized (1:1) controlled trial (RCT) running in four European countries (The Netherlands, Spain, France, and Sweden). Subjects with conductive or mixed hearing loss or single-sided sensorineural deafness were included. Results: During the first year, in the Netherlands (NL), France (FR), and Spain (ES) a net cost saving was achieved in favor of the test intervention because of a lower cost associated with surgery time and adverse event treatments [NL €86 (CI -50.33; 219.20), FR €134 (CI -3.63; 261.30), ES €178 (CI 34.12; 97.48)]. In Sweden (SE), the HA-coated abutment was more expensive than the conventional abutment, which neutralized the cost savings and led to a negative cost (SE €-29 CI -160.27; 97.48) of the new treatment modality. After 3 years, the mean cost saving reduced to €17 (CI -191.80; 213.30) in the Netherlands, in Spain to €84.50 (CI -117.90; 289.50), and in France to €80 (CI -99.40; 248.50). The mean additional cost in Sweden increased to €-116 (CI -326.90; 68.10). The consequences in terms of the subjective audiological benefit and Health-related quality of life (HRQoL) were comparable between treatments. A trend was identified for favorable results in the test group for some consequences and statistical significance is achieved for the cosmetic outcome as assessed by the clinician. Conclusions: From this multinational cost-consequence analysis it can be discerned that health care systems can achieve a cost saving during the first year that regresses after 3 years, by implementing soft tissue preservation surgery with a HA-coated abutment in comparison to the conventional treatment. The cosmetic results are better. (sponsored by Cochlear Bone Anchored Solutions AB; Clinical and health economic evaluation with a new Baha® abutment design combined with a minimally invasive surgical technique, ClinicalTrials.gov NCT01796236).

13.
Radiol Med ; 125(3): 272-279, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31784927

ABSTRACT

OBJECTIVE: The purpose of this study is to investigate the role of cervical radiography in the study of patients with vertigo and dizziness. PATIENTS: This is a retrospective single-institution case series study of 493 patients suffering from vertigo and dizziness who were referred (from January 2011 to December 2012) to the hospital to study those symptoms. METHODS: We studied cervical radiographies, CT and MRI of the cervical spine made in the sample and the radiological findings. We analyzed demographic characteristics, presence of psychiatric pathology and emergency assistance due to vertigo in patients who have undergone cervical study. RESULTS: A total of 57% of patients had cervical radiography made; this was more frequent in women, Spanish people, with psychiatric pathology and who have gone to the emergency department for vertigo (p < 0.05). Degenerative changes were found in 74.1% of the patients with radiography made, more frequently at an older age, osteophytes in 49.5% and abnormal cervical lordosis in 37.1%. CONCLUSIONS: There are sociodemographic factors that influence in the request for cervical radiographs in patients with vertigo and dizziness. Given the suspicion of cervical vertigo, we do not consider that the findings in the radiographs help in the diagnosis. In our opinion, an excessive use of cervical radiography is made in patients with vertigo and dizziness.


Subject(s)
Cervical Vertebrae/diagnostic imaging , Dizziness , Magnetic Resonance Imaging/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Vertigo , Analysis of Variance , Chi-Square Distribution , Dizziness/epidemiology , Emergencies , Emergency Service, Hospital/statistics & numerical data , Female , Humans , Male , Medical Overuse/statistics & numerical data , Middle Aged , Retrospective Studies , Sex Distribution , Spain/epidemiology , Vertigo/epidemiology
14.
Acta otorrinolaringol. esp ; 70(6): 358-363, nov.-dic. 2019. tab, graf
Article in Spanish | IBECS | ID: ibc-184881

ABSTRACT

Los dispositivos auditivos osteointegrados (DAO) Power y SuperPower presentan indicaciones para umbrales en vía ósea de 55 y 65dB, respectivamente. Realizamos un estudio observacional prospectivo de una serie de 6 casos con hipoacusia mixta en los que se realizó implantación del DAO Ponto(TM) SuperPower. Se realizaron previo a la implantación y 6 meses tras la adaptación valoraciones tonales y verbales sin y con ruido de fondo (HINTS). Todos los participantes mostraron mejoría en los resultados tonales y verbales, variando según el grado de hipoacusia contralateral. Cabe destacar los resultados verbales con ruido de fondo donde la mayoría de los pacientes obtuvieron una relación señal ruido entre 2 y 4 dB. Los resultados en los cuestionarios APHAB y GBI mostraron una reducción de la percepción del problema y una mejoría en la calidad de vida, respectivamente. Los resultados presentados reflejan la posibilidad de tratamiento de hipoacusias mixtas con el dispositivo DAO Ponto(TM) SuperPower


Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto(TM) Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. The results in the APHAB and GBI questionnaires showed a reduction in the perception of the problem and an improvement in quality of life respectively. The results presented reflect the possibility of treatment of mixed hearing loss with the Ponto(TM) SuperPower device


Subject(s)
Humans , Male , Female , Middle Aged , Bone-Anchored Prosthesis/trends , Hearing Loss, Mixed Conductive-Sensorineural/diagnosis , Hearing Loss, Mixed Conductive-Sensorineural/therapy , Quality of Life , Hearing Aids , Prospective Studies , Osseointegration , Audiometry
15.
Rev. neurol. (Ed. impr.) ; 68(8): 326-332, 16 abr., 2019. tab
Article in Spanish | IBECS | ID: ibc-180666

ABSTRACT

Introducción. Vértigo y mareo son síntomas que suponen una carga significativa en el hospital e involucran a varias especialidades. Existen pocas guías sobre la solicitud de pruebas radiológicas ante estos síntomas. Objetivos. Conocer qué perfil de pacientes con vértigo y mareo tiene realizadas pruebas de neuroimagen, cuantificar y describir los hallazgos radiológicos, y analizar el coste-utilidad de la tomografía computarizada (TC) y la resonancia magnética (RM) en pacientes con estos síntomas. Pacientes y métodos. Estudio descriptivo en el que se seleccionan pacientes remitidos al hospital por vértigo y mareo. Se analizan características demográficas y clínicas y se cuantifican las pruebas de neuroimagen solicitadas. Se describen los hallazgos radiológicos, se valora su relevancia en el diagnóstico y se detalla el coste. Resultados. Se identifica a 493 pacientes, el 60% tiene realizada una prueba de neuroimagen; son pacientes de más edad, depresivos y que han acudido a urgencias por vértigo. La prueba más realizada fue la TC de cráneo sin contraste (el 5% identifica la causa del síntoma). La que presentó más hallazgos significativos fue la RM de la base del cráneo (17,7%). Las 286 pruebas de imagen solicitadas por vértigo costaron 56.741 euros. El gasto para obtener un diagnóstico radiológico fue de 1.576 euros. Conclusiones. Se realiza un gran número de TC y RM de cabeza en pacientes con vértigo y mareo. Es recomendable tener un diagnóstico de sospecha previo a partir de la anamnesis y la exploración para hacer una buena selección de las pruebas que hay que solicitar. En más del 90% de los casos no se muestran hallazgos radiológicos en relación con el vértigo


Introduction. Vertigo and dizziness are symptoms with a significant burden in the hospital and involve several specialties. There are few guidelines of radiological tests for these symptoms. Aims. To know which profile of patients with vertigo and dizziness has neuroimaging tests, quantify and describe the radiological findings. To analyze the cost-utility of CT and MRI in the study of these patients Patients and methods. Descriptive study, we selected patients referred to the hospital for vertigo and dizziness. We analyze demographic and clinical characteristics and quantify the neuroimaging tests requested. We describe the radiological findings, assess their relevance in the diagnosis and detail the cost-benefit. Results. We identified 493 patients, those with neuroimaging test (60%) are older, depressed and frequented the emergency department because of vertigo. The most requested test was the cranial CT scan (5% identifies the cause of the symptom). MRI of the inner ear and cerebellopontine angle was the test that presented the most significant findings (17.7%). The 286 image tests requested for vertigo cost 56,741 euros. The cost for a positive test was 1,576 euros. Conclusions. A large number of head CT and MRI are made in patients with vertigo and dizziness. A clinical suspicion is recommended from the anamnesis and exploration to make a good selection of test to request. In more than 90% of cases, radiological findings are not shown in relation to vertigo


Subject(s)
Humans , Male , Female , Middle Aged , Vertigo/diagnostic imaging , Dizziness/diagnostic imaging , Cost-Benefit Analysis , Nervous System Diseases/diagnostic imaging , Nervous System Diseases/economics , Tomography, X-Ray Computed/economics , Magnetic Resonance Imaging/economics , Retrospective Studies , Cohort Studies
16.
Article in English, Spanish | MEDLINE | ID: mdl-30573155

ABSTRACT

Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto™ Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. The results in the APHAB and GBI questionnaires showed a reduction in the perception of the problem and an improvement in quality of life respectively. The results presented reflect the possibility of treatment of mixed hearing loss with the Ponto™ SuperPower device.


Subject(s)
Bone Conduction , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural/therapy , Osseointegration , Prostheses and Implants , Auditory Threshold , Equipment Design , Female , Humans , Male , Middle Aged , Patient Satisfaction , Prospective Studies , Quality of Life , Signal-To-Noise Ratio , Surveys and Questionnaires , Treatment Outcome
17.
Acta otorrinolaringol. esp ; 69(4): 219-225, jul.-ago. 2018. tab, graf
Article in Spanish | IBECS | ID: ibc-180487

ABSTRACT

INTRODUCCIÓN Y OBJETIVOS: Los síntomas de vértigo y mareo son frecuentes en la población, se presentan como manifestación de un amplio abanico de enfermedades y habitualmente es difícil realizar un diagnóstico de certeza. El objetivo general de este estudio es obtener la información para evaluar estos síntomas en el entorno hospitalario. Los objetivos específicos son: estimar el peso global que representan estos síntomas en las derivaciones al hospital; conocer las características de los pacientes derivados y detallar el flujo de las consultas. MÉTODOS: Estudio descriptivo observacional. Se buscaron las propuestas de consulta realizadas en 2011 y 2012 al hospital por el síntoma de vértigo. Se analizaron características demográficas y clínicas de los pacientes, y administrativas de las derivaciones. RESULTADOS: Se analizaron un total de 558 propuestas correspondientes a 494 pacientes. El vértigo supuso el 0,5% del total de las derivaciones realizadas desde Atención Primaria al hospital. El 63% de la muestra han sido mujeres, con una edad media de 58 años. El 88% de los pacientes fue valorado por Otorrinolaringología y el 24% por Neurología. Un 30,8% consultó en 3 o más ocasiones por el síntoma. El 16% fue valorado por enfermedad psiquiátrica en el hospital. CONCLUSIONES: El vértigo como síntoma supone una carga significativa en el ámbito hospitalario. Los pacientes que lo presentan consultan en múltiples ocasiones y son valorados en distintas especialidades. En ciertos casos, el flujo de pacientes puede resultar excesivamente dinámico e ineficaz. En nuestro entorno, Otorrinolaringología es el principal receptor de pacientes con síntomas de vértigo y mareo


INTRODUCTION AND OBJECTIVES: Vertigo and dizziness as symptoms are frequent in the population. They are present in a wide range of pathologies and it is usually difficult to make an accurate diagnosis. The general objective of this study is to obtain the information to evaluate vertigo and dizziness in the hospital setting. The specific objectives are: to estimate the burden of these symptoms at the hospital; to study patients' conditions and to detail the flow of these patients inside the hospital. METHODS: Observational descriptive study. We made a search of the referral proposals made in 2011 and 2012 to the hospital because of vertigo symptoms. The patients' demographic and clinical characteristics, and the administrative details of the referrals were analysed. RESULTS: A total of 558 proposals were analysed corresponding to 494 patients. Vertigo accounted for 0.5% of all referrals made from Primary Care to the hospital. Sixty-three percent of the sample were women; the average age was 58 years. Eighty-eight percent of the patients were evaluated by Otorhinolaryngology, 24% by Neurology. Thirty point eight percent consulted on 3 or more occasions for the symptom. Sixteen percent were assessed for psychiatric conditions in the hospital. CONCLUSIONS: Vertigo as a symptom is a significant burden in the hospital setting. The patients who suffer it consult on several occasions and are assessed by different specialties. This implies in some cases an excessive and ineffective flow of patients. In our setting, otorhinolaryngology is the main department to treat vertigo and dizziness patients


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Adult , Middle Aged , Aged , Vertigo/diagnosis , Vertigo/epidemiology , Vertigo/therapy , Dizziness/diagnosis , Dizziness/epidemiology , Dizziness/therapy , Observational Study , Cross-Sectional Studies , Referral and Consultation/statistics & numerical data , Retrospective Studies
18.
Eur Arch Otorhinolaryngol ; 275(7): 1903-1911, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29679154

ABSTRACT

PURPOSE: This study aimed to determine the effectiveness of a mandibular advancement device in a sample of obstructive sleep apnea syndrome patients by the evaluation of respiratory and neurophysiologic parameters and clinical symptoms. Second, the influence of certain predictor factors related with the patient and the intraoral device, were considered in the final response with this treatment option. METHODS: Forty-one patients constituted the final sample. Outcomes were measured using polysomnography, Epworth sleepiness scale and an analogue visual snoring scale, before treatment and once the device was properly titrated. RESULTS: Mean apnea-hypopnea index decreased from 22.5 ± 16.8 to 9.1 ± 11.6 (p ≤ 0.05), influencing only gender and Fujita index as predictor factors. The oxygen saturation, arousal index, percentages of sleep stages and sleep efficiency significantly improved with the mandibular advancement device (MAD) placement. The snoring index improved in absolute terms in 6.1 units and the excessive daytime sleepiness was reduced from 12.2 ± 4.7 to 8.5 ± 3.8 (p ≤ 0.00). CONCLUSIONS: The successful treatment rate with the MAD was 65.8%. The placement and posterior regulation of the intraoral appliance efficiently reduced the apnea-hypopnea index, improved the sleep quality and the clinical symptomatology associated. Obstructive sleep apnea syndrome is a highly prevalent disease. and dentists should be aware of the benefits enhanced by this prosthetic device, considered the first treatment option by certain physicians.


Subject(s)
Mandibular Advancement/instrumentation , Sleep Apnea, Obstructive/surgery , Adult , Aged , Female , Humans , Male , Middle Aged , Polysomnography , Prospective Studies , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/physiopathology , Sleep Stages , Snoring/etiology , Snoring/therapy , Treatment Outcome